HomeMy WebLinkAboutWQCS00352_Renewal (Application)_20180221RECEtVED/DENROWR
FEB Z 12018
Water Resources
Permitting Section
HOKE COUNTY - NORTH CAROLINA
WASTEWATER COLLECTION SYSTEM PERMIT
(PERMIT No. WQCS00352)
APPLICATION FOR PERMIT RENEWAL
OVA
4*
FEBRUARY 2018
Letitia Edens
County Manager
February 6, 2018
Deborah Gore, PERCS Unit Supervisor
NCDEQ-DWR — Water Quality Permitting Section
512 N. Salisbury St., Suite 925
Raleigh, NC 27604
Subject: Hoke County
Wastewater Collection System — Permit No: WQCS00352
Application for Permit Renewal
Dear Ms. Gore,
Phone: (910) 875-8751
Fax: (910) 875-7651
ledens@liokecountv.ore
RECEIVED/DENR/DWR
FEB 21 2018
Water Resources
Permitting Section
Hoke County is submitting the enclosed application to the PERCS Unit for renewal of the Wastewater
Collection System Permit (DEQ Permit No.: WQC500352). Attached are the following items related to the
permit renewal:
1. Application for permit renewal
2. Delegation Letter
3. Pump Station List
4. High Priority Lines List
5. Annual Budget for Collection System
6. Updated Capital Improvement Plan
7. Response Action Plan
8. Contingency Plan
9. Comprehensive Collection System Map
If you have any questions regarding the attached application, please do not hesitate to contact me at
910-875-8751 or ledens@hokecounty.org.
Sincer
6
, L6f��
Letitia Edens, Co ty Manager
227 N. Main Street
Raeford, NC 28376
HOKE COUNTY
Pratt Building - P.O. Box 1585 -227 N. Main St. - Raeford, NC 28376 - (910) 875-8751 - Fax (910) 875-7651
� - r
Division of Water Resources
State of North Carolina
Department of Environmental Quality
Division of Water Resources
15A NCAC 02T.0400 — SYSTEM -WIDE WASTERWATER COLLECTION SYSTEMS
INSTRUCTIONS FOR FORM CSA 04-16 & SUPPORTING DOCUMENTATION
Documents shall be prepared in accordance with 15A NCAC 02T .01009 15A NCAC 02T .0400, and all relevant
Division Policies. Failure to submit all required items will necessitate additional processing and review time.
For more information, visit the System -vide Collection System Permitting website
General — When submitting an application to the Pretreatment, Emergency Response, & Collection Systems (PERCS) Unit,
please use the following instructions as a checklist in order to ensure all required items are submitted Adherence to these
instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested
additional information
The Applicant shall submit one original and one copy of the application and supporting documentation.
A. Cover Letter
E Submit a cover letter listing all items and attachments included in the permit application package
B. No Application Fee Required
➢ No application fee is necessary The permittee will be billed an annual fee upon issuance of the permit
➢ The appropriate annual fee for systemwide wastewater collection system permits may be found at
➢ Annual Non -Discharge Fees
C. System -Wide Wastewater Collection System (FORM: CSA 04-16) Application:
E Submit the completed and appropriately executed System -wide Wastewater Collection System (FORM- CSA 04-
16) application Any unauthorized content changes to this form shall result in the application package being
returned If necessary for clarity or due to space restrictions, attachments to the application may be made, as long
as the attachments are numbered to correspond to the section and item to which they refer
❑ If the Applicant Type in Section I.3 is a Privately -Owned Public Utility, provide the Certificate of Public
Convenience and Necessity (CPCN) from the North Carolina Utilities Commission demonstrating the Applicant is
authorized to hold the utility franchise for the area to be served by the wastewater collection system, or
❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewei Division Public Staff stating an
application for a franchise has been received and that the service area is contiguous to an existing franchised area
or that franchise approval is expected.
❑ If the Applicant Type in Section 13 is a corporation or company, provide documentation if it is registered for
business with the North Carolina Secretary of State
D. General Information:
➢ The Authorized signing official listed in Section I.4 should match with that of the Applicant certification page in
accordance with 15A NCAC 02T .0106(b) Per 15A NCAC 02T .0106(c), an alternate person maybe designated
as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T
.0106(b).
➢ NOTE - Public Works Director's are not authorized to sign this permit application according to the rule
unless they are delegated.
INSTRUCTIONS FOR APPLICATION CSA 04-16 & SUPPORTING DOCUMENTATION Page 1 of 5
E. Summary of Attachments Required:
® Instruction A: Cover Letter
® Instruction C: Application
❑ Instruction C: Ownership Documentation (i.e. CPCN) (If necessary)
® Instruction D: Delegation Letter (If necessary for signing official)
® Section IV.3 Pump Station List
® Section IVA High Priority Lines List
® Section VA
Annual Budget for Collection System (Updated and Approved)
® Section V.6
Capital Improvement Plan (Updated and Approved)
® Section VI.2
Response Action Plan
® Section VIA
Contingency Plan
® Section VI.6
Comprehensive Collection System Map
❑ Section VII
Note Any Potential Compliance Issues
THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND
MATERIALS, SHOULD BE SENT TO:
NCDEQ-DWR
Water Quality Permitting Section
PERCS UNIT
By U.S. Postal Service:
Attn: PERCS Unit Supervisor
1617 MAIL SERVICE CENTER
RALEIGH, NORTH CAROLINA 27699-1617
TELEPHONE NUMBER: (919) 807-6300
By Courier/Special Delivery:
512 N. SALISBURY ST. Suite 925
RALEIGH, NORTH CAROLINA 27604
INSTRUCTIONS FOR APPLICATION CSA 04-16 & SUPPORTING DOCUMENTATION Page 2 of 5
I. APPLICANT INFORMATION
1 Applicant's name (Municipality, Public Utility, etc) Hoke County
2 Facility Information Name Hoke County Collection System Permit No WQCS00352
3 Applicant type ® Municipal ❑ State ❑ Privately -Owned Public Utility
❑ County ❑ Other
4 Signature authority's name Letitia Edens per 15A NCAC 02T 0106(b)
Title County Manager
5 Applicant's mailing address 227 N Main Street
City Raeford State NC Zip 28376-
6 Applicant's contact information
Phone number (910) 875-8751 Fax number (_) _- Email address ledens(@hokecounty org
II. CONTACT/CONSULTANT INFORMATION:
1 Contact Name Hilton Villmes
2 Title/Affiliation Public Utilities Director, Hoke County
3 Contact's mailing address PO BOX 240
4 City Raeford State NC Zip 28376-
5 Contact's information
Phone number (910) 848-038 Fax number (910) 875-2590 Email address hvillines(a_hokecounty org
III. GENERAL REQUIREMENTS:
1 New Permit or Premit Renewal? ❑ New ® Renewal
2 County System is located in Hoke County
3 Owner & Name of Wastewater Treatment Facility(ies) receiving wastewater from this collection system
Owner(s) & Name(s) Hoke County WWTF
4 WWTF Permit Number(s) NCO089176
5 What is the wastewater type? 100 % Domestic Ior % Industrial (See 15A NCAC 02T 0103(20))
y Is there a Pretreatment Program in effect? ❑ Yes or ❑ No
6 Wastewater flow 0 333 MGD (Current average flow of wastewater generated by collection system)
7 Combined permitted flow of all treatment plants 15 MGD
8 Explain how the wastewater flow was determined ® 15A NCAC 02T 0114 or ❑ Representative Data
9 Population served by the collection system
IV. COLLECTION SYSTEM INFORMATION:
1 Line Lengths for Collection System
Sewer Line Description
Length
Gravity Sewer
30
miles
Force Main
15
miles
Vacuum Sewer
0
miles
Pressure Sewer
0
miles
APPLICATION CSA 04-16 Page 3 of 5
Pump Stations for Collection System
Pump Station Type
Certification Number 23252
Number
Simplex Pump Stations(Serving Single Building)
Simplex Pump Stations(Serving Multiple Buildings)
Duplex Pump Stations
11
3 Submit a list of all mayor (i e not simplex pump station serving a single family home) pump stations Include the following
information
➢ Pump Station Name
➢ Physical Location
➢ Alarm Type (i a audible, visual, telemetry, SCADA)
➢ Pump Reliability (Can convey peak hourly wastewater flow with largest single pump out of service)
➢ Reliability Source (permanent/portable generator, portable pumps)
➢ Capacity of Station (Pump Station Capacity in GPM)
-4 Submit a list of all high priority lines according per 15A NCAC 02T 0402 (2) known to exist in the collection system Head
the list with "Attachment A for Condition V(4)" and include the system name
➢ Use the same line identification regularly used by the applicant
➢ Indicate type of high priority line (i a aerial), material and general location
V. COLLECTION SYSTEM ADMINISTRATION:
1 Provide a brief description of the organizational structure that is responsible for management, operation and maintenance of
the collection system
2 Indicate the current designated collection system operators for the collection system per 15A NCAC 08G 0201
Main ORC Name Philli M O' uinn
Certification Number 23252
Back -Up ORC Name Michael E Dean
Certification Number 1001021
Seethe "WQCS Contacts and ORC Report' for a current listing of the ORC(s) the Division has on file for WQCS permit
3 Approximate annual budget for collection system only $ 1,298,554 00
4 Submit a copy of your current annual budget.
5 Approximate capital improvement budget for the collection system only: $ 149,856 00
6 Submit a copy of your current capital improvement plan.
7 Is this collection system currently a satellite system ❑ Yes or ® No
8 Do any satellite systems discharge to this collection system ❑ Yes or ® No (If yes complete table below)
Satellite System Contact Information(Name, Address, Phone Number
Complete for Satellite Systems that have a flow or capacity greater than 200,000 GPD (Average daily flow)
9 List any agreements or ordinances currently in place to address flows from satellite systems
N/A
APPLICATION CSA 04-16 Page 4 of 5
VI. COLLECTION SYSTEM COMPLIANCE:
1. Is a Response Action Plan currently in place ® Yes or ❑ No
2. If Yes, submit a copy of the Response Action Plan or see table 6 below.
3. Is a pump station contingency plan currently in place? ® Yes or ❑ No
4. If Yes, submit a copy of the pump station contingency plan or see table 6 below.
5. Is a comprehensive collection system map currently in place? ® Yes or ❑ No
6. Submit a submit a copy of the collection system map (CD or hardcopy) or indicate a schedule for completion
7. Thoroughly read and _review the System -Wide Collection System Permit Conditions. Typically compliance schedules
are only offered to NEW permit applicants and NOT permit renewals. Any compliance dates must be included within
the permit prior to issuance or the permit holder will be found in violation upon inspection.
Permit Condition
Current
Compliance?
If no, Indicate a
Compliance
Date
Typical
Compliance
Schedule
I(4) — Grease ordinance with legal authority to inspect/enforce
® Yes ❑ No
12 — 18 mo.
I(5) — Grease inspection and enforcement program
® Yes ❑ No
12 — 18 mo.
I(6) — Three to five year current Capital Improvement Plan.
® Yes ❑ No
12 — 18 mo.
I(8) — Pump station contingency plan
® Yes ❑ No
3 mo.
I(9) — Pump station identification signs.
® Yes ❑ No
3 mo.
I(1 f) — Functional and conspicuous audible and visual alarms.
® Yes ❑ No
3 — 6 mo.
II(5) — Spare pumps for any station where one pump cannot
handle peak flows alone (in a duplex station, the 211 pump is
the spare if pump reliability is met).
® Yes ❑ No
6 — 9 mo.
II(7) — Accessible right-of-ways and easements.
® Yes ❑ No
6 — 12 mo.
II(9) — Response action plan with Items 9 (a — h).
® Yes ❑ No
3 mo.
III(3) — Comprehensive collection system map
® Yes ❑ No
10% per year
For conditions not listed, compliance dates are not typically offered. List any permit conditions that may be difficult for the
applicant to meet (attach clarification if needed):
VII. APPLICANT'S CERTIFICATION per 15A NCAC 02T .0106(b):
I, Letitia Edens, County Manager attest that this application for Hoke County
(Signature Authority's Name & Title from Item IA) (Facility name from Item I.1)
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this
application are not completed and that if all required supporting information and attachments are not included, this application package
will be returned to me as incomplete.
Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement,
representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed
$10,000 as well as,, vil penalties u to $2 00 er violation.
iignatu J Date: (�C/,
APPLICATION CSA 04-16 Page 5 of 5
Letitia Edens
County Manager
February 6, 2018
Deborah Gore, PERCS Unit Supervisor
NCDEQ-DWR — Water Quality Permitting Section
512 N. Salisbury St., Suite 925
Raleigh, NC 27604
Subject: Hoke County
Wastewater Collection System — Permit No: WQCS00352
Signature Authority Delegation Letter
Dear Ms. Gore,
Phone: (910) 875-8751
Fax: (910) 875-7651
ledens@hokecounty.org
As an appropriate signing official for the Hoke County as designated by 15A NCAC 2T .0106, 1 hereby
delegate authority to sign and certify all permit applications, reports, or other permit related documents
for the Hoke County Wastewater Collection System (Permit No. WQCS00352), to the following staff
member listed below:
Position
Director of Public Utilities
Person Currently
Mr. Hilton Villines
in Position
Mailing Address
PO Box 240
Raeford, NC 28376
Physical Address
663 East Palmer Street
Raeford, NC 28376
Office Phone
(910) 848-0385
Fax
(910) 875-2590
Email
hvillines@hokecounty.org
This delegated authority is valid only for the above referenced permit and person currently in the position
as listed above. In the event of a personal change, this delegation is no longer valid.
If you have any questions, please do not hesitate to contact me.
Since
Letitia dens, Cougty Manager
l 227 Main Street
Raeford, NC 28376
HOKE COUNTY
Pratt Building - P.O. Box 1585.227 N. Main St. - Raeford, NC 28376 - (910) 875-8751- Fax (910) 875-7651
Section IV.3 - Pump Station List
Hoke County Wastewater Collection System
Pump Station
Count
Pump Station Name
Physical Location
Alarm Type
Pump Reliability
Reliability Source
Capacity (gpm)
3977 Phillipi Church Road,
SCADA Monitored with Audible &
Yes, equipped with in place
Permanent Generator
1
Phillipi Regional
pump redundancy sized to
2,604
Raeford, NC 28376
Visual Local Alarms
with ATS
handle peak flow
6882 Arabia Road,
SCADA Monitored with Audible &
Yes, equipped with in place
Permanent Generator
2
Sandy Grove
pump redundancy sized to
190
Lumber Bridge, NC 28357
Visual Local Alarms
with ATS
handle peak flow
132 Tuxford Court,
SCADA Monitored with Audible &
Yes, equipped with in place
Permanent Generator
3
Westgate
pump redundancy sized to
694
Raeford, NC 28376
Visual Local Alarms
with ATS
handle peak flow
164 Newport Court,
SCADA Monitored with Audible &
Yes, equipped with in place
Permanent Generator
4
Bridgeport
pump redundancy sized to
276
Raeford, NC 28376
Visual Local Alarms
with ATS
handle peak flow
931 Johnson Mill Road
SCADA Monitored with Audible &
Yes, equipped with in place
Permanent Generator
5
Johnson Mill
pump redundancy sized to
1,000
Raeford, NC 28376
Visual Local Alarms
with ATS
handle peak flow
2023 Rockfish Road, Raeford,
SCADA Monitored with Audible &
Yes, equipped with in place
Permanent Generator
6
Beaver Creek
pump redundancy sized to
500
NC 28376
Visual Local Alarms
with ATS
handle peak flow
8493 Fayetteville Road,
SCADA Monitored with Audible &
Yes, equipped with in place
Permanent Generator
7
Highway 401
pump redundancy sized to
720
Raeford, NC 28376
Visual Local Alarms
with ATS
handle peak flow
466 Fayetteville Road, Raeford,
SCADA Monitored with Audible &
Yes, equipped with in place
Permanent Generator
8
Hoke Landing
pump redundancy sized to
417
NC 28376
Visual Local Alarms
with ATS
handle peak flow
715 Rockfish Road,
SCADA Monitored with Audible &
Yes, equipped with in place
Permanent Generator
9
Scurlock
pump redundancy sized to
580
Raeford, NC 28376
Visual Local Alarms
with ATS
handle peak flow
Bedford Drive
SCADA Monitored with Audible &
Yes, equipped with in place
Permanent Generator
10
Bedford
pump redundancy sized to
400
Raeford, NC 28376
Visual Local Alarms
with ATS
handle peak flow
800 Phillip Church Road,
SCADA Monitored with Audible &
Yes, equipped with in place
Permanent Generator
11
Don Steed
pump redundancy sized to
88
Raeford, NC 28376
Visual Local Alarms
with ATS
handle peak flow
Section IVA - High Priority Lines List
Hoke County Wastewater Collection System
Count
Identification
Type of High Priority Line
Line Size & Material
General Location
24 -inch, DIP
Along the south side of Rockfish Rd
1
Rockfish Rd
Aerial Crossing - Gravity Flow
on Steel H -Piles
at the Black Branch Creek crossing
Along gravity outfall between
24 -inch, DIP
Rockfish Rd and Phillipi Church Rd
2
Hendrix Property
Aerial Crossing - Gravity Flow
Downstream of Beaver Creek and
on Steel H -Piles
Black Branch Creek merger at
Hendrix Pond
12 -inch, DIP
Along gravity outfall between Hwy
3
Johnson Mill
Aerial Crossing - Gravity Flow
401 and Johnson Mill Rd crossing
on Steel H -Piles
over Black Branch Creek
18 -inch DIP
Along gravity outfall between Hwy
4
Beaver Creek
Aerial Crossing - Gravity Flow
401 and Rockfish Rd crossing over
on Steel H -Piles
Beaver Creek
06/30/2017 15:21 COUNTY OF HOKE
9698gfer NEXT, YEAR BUDGET LEVELS REPORT
PROJECTION: 2018 2018 BUDGET PROJECTION
SEWER
60 WATER & SEWER FUND
2016 2017 2018
'REVISED BUD REVISED BUD DEPARTMENT
607140
512100
S/W REG
68,666
00
99,776
00
103,795
00
607140
512200
S/W OT
2,000
00
4,500
00
4,500
00
607140
518100
FICA
5,407
00
7,974
00
8,285,00
1'35
607.140
518102
FICA MEDC,
25,000
,00
17,300
00
1,7,300
00
607140
518200
RET CONT
4,994
00
7,.301
00
8,198
00
607140
518300
HOSP INS
14,136
00
21,204
00
24,288
00
607140
518900
OTH FRINGE
90,00
135
00
1,35
00
607140
519000
PROFSERV
25,000
00
25,000
00
25,000
00
607140
520000
SUP/MAT
11„300
00
'15,000
00
17,300
00
607,140
521200
UNIFORMS
2,000
00
2,600
00
6,000
00
607,140
525100
MOTR FULS
4,000
00
5,000
00
10,500
00
607140
531100
TRAVEL
2,1,00
00
2,100
00
5,500
00
607140
532100
TELEPHONE
2,500
00
5,500
00
7,000
00
607140
533000
UT'ILIT,IES
1 5, 000
00
18,000
00
42,000
00
607140
535000
REP/MAINT
00
00
00
00
00
607140
53,5200
M/R EQT3IP
15,000
00
35,000
00
45,700
00
607140
5'35'300
M/R VEH,ICL
1,000
00
2,000
00
4,000
00
6071,40
535900
M/R SEWER
1,2, 000
00
15,000
00
15,000
00
607,140
543000
RENT OTHER
1,000
00
1,000
00
1,000
00
607,14,0
544000
S/M CONTRT
125,000
00
60,000
00
67,000
00
607140
544003
IMPACT FEE
30,000
00
30,000
00
30,000
00
607140
548055
TNDCOSTEXP
00
00
00
607140
549000
SEWER CHG
205,000
00
24,000
00
28,999
00
60'7140
54,9100
DUES/SUBS
1, 000
00
1, 000
00
1, 000
00
607140
5.49900
TAP FEES
00
00
00
6071,40
550000
CAP OUTLAY
90,000
00
186,000
00
149,856
00
607140
559001
CONST DINE
00
00
00
607140
57,1000
D/S BOND P
1,00,946
00
104,278
00
104,278
00
607140
57100,9
401 SEWER
00
00
00
607140
572000
D/S BOND I
10,327
00
6,997
00
6,997
00
6071,40
598048
WW1B
00
00
00
607140
598049
WW1A
00
00
00
607140
598053
SANDXGRFS
583,858
00
00
583,858
00
TOTAL
SEWER
1,332;324
00
679,365
00
1,,300,189
00
2018 2018
'MANAGER APPROVAL
103,795
00
102,271
00
4,500
00
4,500
00
8,285
00
8,22,9
00
00
00
8,198
00
8,143
00
24,288
00
247288
00
135
00
1'35
00
25,000
00
25,000
00
17,300
00
1,7,300
00
6,000
00
6,000
00
10,500
00
10,500
00
5,500
00
5,500
00
7,000
00
7,000
00
42,000
00
42,000
00
00
00
45,700
00
45,700
00
4,000
00
4,000
00
15,000
00
1,5, 000
00
1,000
00
1,000
00
67,000
00
67,000
00
30,000
00
30,000
00
00
00
28,999
00
28,999
00
1,000
00
1,000
00
00
00
149,856
00
149,856
00
00
00
104„278
00
104,278
00
00
00
6,997
00
6,997
00
00
00
00
00
583,858
00
583,858
00
1,300,18,9 00 1,298,554 00
P 7
bgnyrpts
FOR PERIOD 99
HOKE COUNTY
COLLECTION SYSTEM
Section V.6 - Capital Improvement Plan
Hoke County Wastewater Collection System
5 -YEAR CAPITAL IMPROVEMENT PROJECTS LIST
NO.
PROJECT
COST ESTIMATE
DESCRIPTION
PLANNED YEAR
1
Vac Truck Dump Station at
$105,000 00
Installation of a new vac truck dump station at the Regional
FY19
Regional Pump Station
Pump Station
Replacement of an existing above ground pump station to a
2
Westgate Pump Station
$590,000.00
submersible pump station; reuse of existing wet well with
FY20
Replacement
replacement of all above ground equipment and installation
of two (2) new submersible pumps
3
Portable By -Pass Pump
$20,000.00
Purchase of a portable by-pass pump that can be used during
FY20
repairs.
4
Combination Vacuum /Jet
$260,000.00
Purchase of a combination vacuum/Jet truck to assist with
FY21
Sewer Cleaning Truck
repairs.
Replacement of an existing above ground pump station to a
5
Bridgeport Pump Station
$555,000.00
submersible pump station, reuse of existing wet well with
FY22
Replacement
replacement of all above ground equipment and installation
of two (2) new submersible pumps
Influent Grinders in Concrete
6
Manhole at Hwy 401 PS &
$130,000 00
Installation of a in-line grinder for the gravity outfall at the
FY22
Bedford PS
Hwy 401 Pump Station and the Bedford Pump Station.
COUNTY OF IHOKE
Public Utilities Hilton Villines, Director
Post Office Box 240 / 663 E. Palmer Street
Raeford, North Carolina 28376
(910) 848-0385
Response Action Plan
In the event of an emergency related to the Hoke County Wastewater Collection
System, the following document serves as the standard Response Action Plan.
a. Contact phone numbers for 24-hour response, including weekends and holiday
Primary Contact: Phil O'Quinn Phone: (910) 751-6072
Secondary Contact(s): Kelvin Hampton Phone: (910) 709-3540
Travis Eatmon Phone: (910) 751-6076
On -Call Public Utilities Staff Member Phone: (910) 624-5413
b. Response time:
General response time to the scene of an emergency call is between 30 — 45
minutes, depending on the location of the call within the County.
c. Equipment list and spare parts inventory:
Available Equipment that is Owned by Hoke County Public Utilities Department:
• Service Truck
• Back hoe
• Skid Steer
• Mini -Excavator
• Trailer Mounted Jetter
• Portable Sewer Camera
d. Access to cleaning equipment:
The Public Utilities Department has a SERCO trailer mounter fetter that is used to
for routine maintenance and cleaning as well as emergency call. Also available is a
portable sewer camera for investigation and inspection of the collection system.
e. Access to construction crews, contractors and/or engineers:
The County maintains a service contract with two local contractors to provide on-
call services for emergency and non -emergency repairs to the collections systems
and associated pump stations.
Pump Station Repairs:
Collections System Repairs:
Charles R. Underwood, Inc
2000 Boone Trail Road
Sanford, NC 27330
Phone: (919) 775-2463
McArthur Construction Co.
780 S. Roberts Avenue
Lumberton, NC 28358
Phone: (910) 618-1400
The County utilizes the following contractors for pumping services during
emergency and non -emergency situations depending on their availability:
• Pembroke Waste Collections Inc. — (910) 521-2846
• Total Eviro & Septic, Inc — (919) 770-0028
f. Source(s) of emergency funds:
The sewer collections system budget includes a line item for emergency repairs.
g. Site restoration and clean up materials:
When emergency situations require site restoration and clean up beyond the
available equipment within the Department, the Contractors listed above are
contacted to assist the complete all cleanup and restorations.
h. Post-SSO assessment
The County staff will remain on-site until the emergency situation is under control
and the collection system is functioning properly. When necessary, the Department
staff will make return trips to the incident site, depending on each situation and the
likely hood of a reoccurrence.
COUNTY OF HOKE
Public Utilities Hilton Villines, Director
Post Office Box 240 / 663 E. Palmer Street
Raeford, North Carolina 28376
(910) 848-0385
Pump Station Contingency Plan
Hoke County owns and operates eleven (11) wastewater pump stations as part of
the Hoke County Collection System. Each pump station is equipped with a
Supervisory Control And Data Acquisition (SCADA) which monitors the stations
24n. The SCADA system is set to notify the Collection System ORC and other
appropriate staff when an alarm occurs.
All County owned pump stations were design and constructed with pump
redundancy and capacity necessary to handle the peak tributary flow. Also, each
pump station is outfitted with an stand-by diesel power generator and automatic
transfer switch which is capable of providing auxiliary power in the event the
primary power fails.
Below is a list of the Hoke County pump stations:
Count
Pump Station Name
Physical Location
1
Phillipa Regional
3977 Phillipi Church Road, Raeford, NC 28376
2
Sandy Grove
6882 Arabia Road, Lumber Bridge, NC 28357
3
Westgate
132 Tuxford Court, Raeford, NC 28376
4
Bridgeport
164 Newport Court, Raeford, NC 28376
5
Johnson Mill
931 Johnson Mill Road, Raeford, NC 28376
6
Beaver Creek
2023 Rockfish Road, Raeford, NC 28376
7
Highway 401
8493 Fayetteville Road, Raeford, NC 28376
8
Hoke Landing
466 Fayetteville Road, Raeford, NC 28376
9
Scurlock
715 Rockfish Road, Raeford, NC 28376
10
Bedford
Bedford Drive, Raeford, NC 28376
11
Don Steed