Loading...
HomeMy WebLinkAboutWQ0032855_AR Review_20171221 State of North Carolina | Environmental Quality | Water Resources 2090 U.S. 70 Highway, Swannanoa, NC 28778 828-296-4500 December 21, 2017 Doug Barrick Town of Rutherfordton 129 N Main St Rutherfordton, NC 28139 SUBJECT: Compliance Inspection Report Annual Report (2016) Review Town of Rutherfordton RLAP Non-discharge Permit No. WQ0032855 Rutherford County Dear Permittee: The North Carolina Division of Water Resources has completed a review of the 2016 Annual Report and additional information received on July 12, 2017. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non-discharge Permit No. WQ0032855. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact me at 828-296-4500 or via email at bev.price@ncdenr.gov. Sincerely, Beverly Price Environmental Senior Specialist ATTACHMENT: Inspection Report 20171221_WQ0032855_CEIARR.rtf Compliance Inspection Report Permit:WQ0032855 Effective:01/01/17 Expiration:12/31/21 Owner :Town of Rutherfordton SOC: Contact Person: Region: County: Directions to Facility: Rutherford Asheville Doug Barrick Effective:Expiration:Facility:Town of Rutherfordton RLAP 1021 S Main St Rutherfordton NC 28139 Title:Phone:828-287-3520Town Manager From I-40E, take exit 85, stay on Hwy. 221 through the Town of Rutherfordton. Approximately 0.5 mi outside city limits, turn left on gravel road to WWTP (just before intersection of 221&Thunder Rd.) Secondary ORC(s): 336-957-8909Phone:15704Certification:Dennis KeyPrimary ORC: LA,System Classifications: 24 hour contact name Dennis Key 336-957-8909 On-Site Representative(s): Related Permits: NC0025909 Town of Rutherfordton - Rutherfordton WWTP Secondary Inspector(s): Primary Inspector: Inspection Date:Exit Time:Entry Time: Phone: 06/27/2017 11:00AM 12:30PM Beverly Price 828-296-4500 Facility Status: Permit Inspection Type: Reason for Inspection:Inspection Type: Not CompliantCompliant Routine Land Application of Residual Solids (503) Annual Report Review Question Areas: Miscellaneous Questions Record Keeping Pathogen and Vector Attraction (See attachment summary) Page:1 Inspection Date: Permit: Inspection Type : Owner - Facility: Reason for Visit: WQ0032855 06/27/2017 Annual Report Review Town of Rutherfordton Routine Inspection Summary: The Annual Report review was conducted by Beverly Price of the Asheville Regional Office. 35.48 dry tons of residuals were land applied to permitted fields in Rutherford County in 2016. The soils analysis was done in November 2016. Three fields had pH's below 6. Field #6 had a pH 5.8 and the soils report recommended the addition of lime; lime was added in October 2016. Two fields had pH's=5.9; no recommendations of lime were given. All Exchangeable Sodium Percentages (ESP) were 1. All Zinc & Copper Indices were below 2000. Nutrients/metals/TCLP analyses were conducted as required by the permit. The pH for the residuals sample was 7.25. Heavy metals and TCLP results appeared to be within permit limits. PAN and and heavy metal cumulative pollutant rates appeared to be within permit limits. Pathogen Reduction was accomplished using Alternative 1 (Fecal Coliform Density). The geometric mean appeared to be calculated correctly. The samples (7) were all collected on the same day. The EPA Manual, Environmental Regulations and Technology, Control of Pathogens and Vector Attraction in Sewage Sludge (the Whitehouse Manual) recommends collecting fecal coliform samples over a two-week period. Vector Attraction Reduction (VAR) was accomplished using Alternative 3 (30-day Bench Scale). The calculation was done on volatile solids and the calculation appeared to be done correctly with a reduction of 9.05%. However, the full documentation required for the test was not submitted. Documentation of the temperature at time of analysis and the laboratory bench sheets should be provided. Additional information submitted to the Asheville Regional Office: 30-Day Bench Scale analysis:Temperature at which the test was run and laboratory bench sheets. Page:2 Inspection Date: Permit: Inspection Type : Owner - Facility: Reason for Visit: WQ0032855 06/27/2017 Annual Report Review Town of Rutherfordton Routine Type Yes No NA NE Distribution and Marketing Land Application Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? Are GW samples from all MWs sampled for all required parameters? Are there any GW quality violations? Is GW-59A certification form completed for facility? Is a copy of current permit on-site? Are current metals and nutrient analysis available? Are nutrient and metal loading calculating most limiting parameters? a. TCLP analysis? b. SSFA (Standard Soil Fertility Analysis)? Are PAN balances being maintained? Are PAN balances within permit limits? Has land application equipment been calibrated? Are there pH records for alkaline stabilization? Are there pH records for the land application site? Are nutrient/crop removal practices in place? Do lab sheets support data reported on Residual Analysis Summary? Are hauling records available? Are hauling records maintained and up-to-date? # Has permittee been free of public complaints in last 12 months? Has application occurred during Seasonal Restriction window? The metals and nutrient analyses provided are for 2016; 2017 analyses have not been reviewed.Comment: Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E (Class A or B) Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram Fecal coliform SM 9222 D (Class B only) Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram b. pH records for alkaline stabilization (Class A) c. pH records for alkaline stabilization (Class B) Temperature corrected d. Salmonella (Class A, all test must be < 3MPN/4 gram day) Page:3 Inspection Date: Permit: Inspection Type : Owner - Facility: Reason for Visit: WQ0032855 06/27/2017 Annual Report Review Town of Rutherfordton Routine e. Time/Temp on: Digester (MCRT) Compost Class A lime stabilization f. Volatile Solids Calculations g. Bench-top Aerobic/Anaerobic digestion results 30-Day Bench Scale Test -The temperature at time of analysis was not included in documentation. The bench sheets were not included in the documentation. Comment: Page:4