Loading...
HomeMy WebLinkAboutNC0038997_Authorization to Construct_20021025Michael F Easley, Governor State of North Carolina William G Ross, Jr., Secretary Department of Environment and Natural Resources Alan W Klimek, P E , Director Division of Water Quality October 25, 2002 Mr. Jay Manner Roaring Gap Club Inc P 0. Bok 129 Roaring Gap, North Carolina 28668 Subject Authorization to Construct ATC No. 038997AOI NPDES Permit No NCO038997 Alleghany County Dear Mr Manner The Division of Water Quality's NPDES Unit has reviewed your request for an Authorization to Construct at the Roaring Gap Club WWTP The Division finds the proposed improvements to be satisfactory and hereby grants authorization for the following • Ultraviolet disinfection unit rated for 40 gpm, uv dosage of 32,000 micro -watt sec/cm' and automatic dialer. This Authorization to Construct is issued in accordance with NPDES Permit No NC0038997, issued April 26, 1999, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the terms and conditions of the permit. The Permttee shall notify the Water Quality Supervisor of the Winston Salem Regional Office, telephone number 336/771-4600, at least forty-eight (48) hours prior to operation of the installed facilities, so that an in -place inspection can be made Notification shall be made during the normal office hours of 8 00 a.m. uintil 5 00 p m , Monday through Friday Engineer's Certification Upon completion of construction and prior to operation of the modified facility, the Permittee shall provide the Division with a certification (copy enclosed) from a professional engineer registered in North Carolina certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct, and the approved plans and specifications The Certification should be subrrm-tted to NCDENR / DWQ, NPDES Unit, 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Requirements for Certified Operator The Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission The Permittee must also employ a certified back-up operator of the appropriatte type and grade to comply with the conditions of Title 15A, Chapter 8G, 0200 The ORC of the facility must visit each Class I facility at least weekly and each Class II, III, and IV facility at least daily, excluding,, weekends and holidays; and must properly manage and document daily operation and maintenance of the facility and comply with all other conditions of Title I5A, Chapter 8G, .0200. Additional Requirements The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and is a condition of this Permit Noncompliance with the terms of the 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone (919) 733-5083 FAX (919) 733-0719 An Equal Opportunity Affirmative Action Employer Internet http Hh2o enr state nc us/ Roaring Gap Club WWTP NPDES Perrmt No NCO038997 ATC No. 038997A01 Page 2 Operational Agreement shall subject the Pernuttee to all sanctions provided by G S 143-215 6 for violation of or failure to act in accordance with the terms and conditions of this Pernut Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division of Water Quality in accordance with North Carolina General Statute 143-215 6A to 143-215.6C The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction The Permittee shall maintain a copy of the approved plans and specifications on file for the life of the facility One (1) copy of the approved plans and specifications is enclosed for your records If you have any questions about this Authorization to Construct, please contact Teresa Rodriguez, at (919) 733-5083, extension 595 Sincerely, Alan W Klimek, P E. Director Enclosures Project Plans (approved) Engineer's Certification Form cc Winston Salem Regional Office, Water Quality Technical Assistance and Certification Unit Central Files NPDES Unit Files Mr John F Phillips, P E — Diehl & Phillips 219 East Chatham St Cary, NC 27511 ATC NOTES ATC No. 038997A01 PERMIT NO NCO038997 FACILITY Roaring ap WWTP COUNTY Alle han RECEIVING STREAM UT to Mitchell River BASIN Yadkin -Pee Dee River CLASS B-Tr FLOW 0.013 MGD APPLICATION/PLANS PREPARED BY: Diehl & Phillips, P. A 219 East Chatham St Cary, NC 27511 SCOPE: Installation of a UV disinfection system. SUMMARY: Roaring Gap Club wants to change the disinfection system from chlorination to UV in response to the new requirement to measure TRC to a level of 17 pg/I They will keep the existing tablet chlorinator, dechlonnator and contact chamber as a backup during power failures. SUBMISSIONS: • Engineering drawings PROJECT EQUIPMENT DESCRIPTION: • Two lamp UV unit rated for 40 gpm, 32,000 micro -watt seconds/cm. • Autodialer to be activated in the event of loss of intensity or lamp failure RECOMMENDATIONS: The proposed system meets the UV guidelines as specified by the Division. Approval of the AtC is recommended Backup is provided with the existing chlorination-dechIon nation system and an autodialer will call the maintenance staff when the lamps loose intensity or fail. NPDES Unit contact: Teresa Rodriguez DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY August 7, 2002 M E M O R A N D U M TO: Ms. Teresa Rodriguez NPDES Unit THROUGH: Steve Mauney - WSRO Acting Supervisor FROM: George Smith - WSRO 146 SUBJECT: ATC Number 038997AO1 Roaring Gap Club Alleghany County AUG N,, 'R - V,"ffR PIALI Y - f CAT :1 "T ! This office reviewed the ultraviolet disinfection (UV) system for reliability with the following comments: It was noted that the tablet chlorinator and dechlorination units to be abandoned in place by removing the tablets. Per 15A NCAC 2H .0124, there must be a continued treatment and disinfection where the interruption of such treatment would render the waters unsafe for their best intended uses. Therefore, this office would suggest an alternative back-up method to meet the minimum reliability conditions. (i.e., back-up power, dual train, etc.) The UV system does not appear to have an automatic cleaning device to insure maximum radiation for proper disinfection. Also, during the time the system is down for cleaning there must not be an interruption in the disinfection process. cc: WSRO DIEHL & PHILLIPS, P.A. CONSULTING ENGINEERS 219 East Chatham Street Cary, North Carolina 27511 Telephone (919) 467-9972 • Fax (919) 467-5327 October 1, 2002 Ms Teresa Rodriguez NPDES Unit-DWQ NC DENR 1617 Mail Service Unit Raleigh, NC 27699-1617 Re Roaring Gap Club NPDES Permit NC 0038997 ATC Number 038997A01 Dear Ms Rodriguez: WILLIAM C. DIEHL, P.E. JOHN F. PHILLIPS, P.E. ALAN R. KEITH, P.E. We offer the following information in response to your review comments on the referenced project. The design has been modified to use the existing tablet chlorinator and dechlorinator as a backup disinfection system in the event of a power outage. The switchover to the backup disinfection system will be automatic during a power outage, due to the recirculation pump station overflowing (no power for the pumps) to the backup system In the event of a lamp failure or loss of intensity, the specified U.V. intensity monitor will cause the autodialer to call the Club's maintenance staff. The staff will then either clean or replace bulbs, or operate two valves to divert the effluent through the backup chlorination/dechlorination system. Enclosed are two sets of revised plans (specifications are on the plans) for your review Please call if you have any further questions. OCT e 2 2002 DENR - WAIER QUALITY PONT SOUPCE [1�AJVCH Yours Very Truly, Diehl & Phillips, P.A. �J- 7. f� � John F. Phillips, P E DIEHL & PHILLIPS, P.A. CONSULTING ENGINEERS 219 East Chatham Street Cary, North Carolina 27511 Telephone (919) 467-9972 • Fax (919) 467-5327 2"r2 DIEHL, P.E. PHILLIPS, RE Z KEITH, RE June 25, 2002 UENR - WATER QUALITY NPDES UNIT -DWQ POINT -SOURCE BRANCH NCDENR-�- 1617 Mail Service Unit Raleigh, NC 27699-1617 T Re Addition of Ultra -Violet Disinfection Unit for Roaring Gap Club NPDES Permit No. NC0038997 _ ; 20� Dear Reviewer ,4 n1SC ARGE PEM , � y'"�`'+ Please find enclosed three sets of plans (with equipment specifications e�plar�s}-fetyt` addition of a U V disinfection unit at the wastewater treatment system for the Roaring Gap Club The U.V unit is being installed to replace the existing chlorination/dechlormation system This change is being made in response to the Division's notification to Permrttees that beginning July 1, 2002, Permittees must measure TRC with an instrument capable of analysis in the 10 to 15- microgram per liter range Rather than purchasing the equipment necessary for the low level TRC measurement, the Club has decided to install ultra -violet disinfection. As an authorized agent for the Club, I hereby request Authorization to Construct the improvements indicated on the plans Although these improvements will not be operational by July 1, the maintenance staff for the Club should have the system operational within 60 to 90 days of receipt of the ATC We request you allow the ORC to continue the current field testing procedures until these improvements can be installed If it is necessary to request an SOC to prevent enforcement actions and penalties, we can make such a request, however, we hope to have the improvements installed in a shorter time period than that usually required to obtain an SOC Please advise if you require any further information Cc Winston-Salem Regional Office, DWQ Mr Jay Manner Mr Hal Transou Yours Very Truly, Diehl & Phillips, P.A. k �D - John F. Phillips, P E. 2002 CISCPARGE PEH,'. Roaring Gap Glub I N C . P.O. BOX 129 ROARING GAP, N.C. 28668 (336) 363-2211 July 16, 2002 Mr. David A. Goodrich Supervisor, NPDES Unit DWQ NCDE1 TR 1617 Mail Service Unit Raleigh, NC 27699-1617 Re Designation of Authorized Representative Dear Mr Goodrich. ly 200,02 D DEP,R - WATER QUALITY POINT SOURCE BRANCH The Roaring Gap Club, Inc , hereby designates John F. Phillips, P E. of Diehl & Phillips, P.A to act as our duly authorized representative for all matters pertaining to the ultraviolet disinfection system addition to our treatment facility (ATC No 038997A01) Please call if you have any questions in this matter Yours Very Truly, Ja ner, =anager Roaring Gap Club, Inc. o�0� WAT�9Q� Michael F Easley, Governor rWrlltam G Ross Jr ,Secretary —i North Carolina Department of Environment and Natural Resources o -c Alan W Khmek, P E , August 19, 2002 John F. Phillips, P E. 219 East Chatham Street Cary, North Carolina 27511 Subject Request for Additional Information Roaring Gap Club NPDES Permit NCO038997 ATC Number 038997A01 Dear Mr. Phillips: The initial review of the plans and specifications for the proposed LTV system for Roaring Gap Club Wastewater Treatment Plant has been completed. The Division issued guidelines for Ultraviolet disinfection systems in November of 2001 The following are part of the requirements of the new guidelines and need to be addressed before we proceed with the issuance of the Authorization to 'Construct - IN Since the discharge is to a class B stream, standby power or a chlorination/dechlormation back up system must be in place unless the perrmttee can demonstrate to the Director's satisfaction that, in the event of a power outage or lamp/unit failure, no untreated water will reach waters of the state Please provide information as to how this requirement is being met. The system shall have an autodialer and audible/visual alarms or a way to alert the operator in responsible charge in the event of a system failure or malfunction. For specific information regarding the UV Guidelines go to our website at http://h2o.enr.state.ne.us/NPDES/NPDESweb.html. Please respond to the questions and provide the requested information prior to September 19, 2002 Thank you in advance for your efforts in responding to this information request. This information will greatly aid the Division in its review of the plans and specifications for the proposed project If you have any questions, please call me at (919) 733-5093, extension 595. Sincerely, Teresa Rodriguez, NPDES Unit 1617 MAIL SERVICE CENTER, RALEIGH, NORTH CAROLINA 27699-1617 - TELEPHONE 919-733-5083/FAX 919-733-0719 AN EQUAL OPPORTUNITY AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLED/ 1 0% POST -CONSUMER PAPER VISIT US ON THE INTERNET @ http //h2o enr.state nc.us/NPDES