Loading...
HomeMy WebLinkAboutNC0038831_Authorization to Construct_20071126t� A ��� Michael F Easley, Governor �Qi�Lrr William G Ross Jr, Secietary North Carolma Department of Environment and Natural Resources '-i Coleen H Sullins, Director Q C Division of Water Quality November 26, 2007 Mr. Richard Durham Carolina Trace Utilities P® Box 240908 Charlotte, North Carolina 28224 SUBJECT: Authorization to Construct A to C No. 038831A02 Carolina Trace Utilities a � Carolina Trace WWTP ss u'4 Lee County Dear Mr. Durham: A letter of request for Authorization to Construct was received September 5, 2007, by the Division, and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of modifications to the existing 0.3125 MGD Wastewater Treatment Plant, with discharge of treated wastewater into the Upper Little River in the Cape Fear River Basin. This authorization results in an increase in design and permitted capacity to 0 675 MGD, and is awarded for the construction of the following specific mod>fications- Installation of a mechanical bar screen with a bypass to an existing bar screen, one 0.350 MGD circular package plant consisting of a 364,326 gallon aeration basin, two 1,510 cfin blowers, a 36 foot diameter clarifier and a 78,419 gallon aerobic digester, two 124 sqare foot traveling bridge filters, a UV disinfection system consisting of two banks capable of disinfecting 1.75 MGD, and an 18 inch discharge line, in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No. NCO038831 issued June 15, 2007, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NCO038831. The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the North Carolina Division of Water Quality. In the event that the facilities fall to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may N�otttliCaiolma North Carolina Division of Water Quality 1617 Marl Service Center Raleigh, NC 27699-1617 Phone (919) 733-7015 Customer Service c� aturalllf Internet www ncwaterguality orq 512 N Salisbury St Raleigh, NC 27604 FAX (919) 733-2496 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper Mr. Richard Durham November 26, 2007 Page 2 be required by this Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Raleigh Regional Office, telephone number (919) 791-4200, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an on site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5.00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct and the approved plans and specifications. Mail the Certification to Cecil G. Madden, Jr, P.E., Construction Grants & Loans, DWQ / DENR, 1633 Mail Service Center, Raleigh, NC 27699- 1633. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of T15A:8G.0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, I1I and IV facility at least daily, excluding weekends and holidays, must properly manage the facility, must document daily operation and maintenance of the facility, and must comply with all other conditions of T15A:8G.0202. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. During the construction of the proposed additions/modifications, the permittee shall continue to properly maintain and operate the existing wastewater treatment facilities at all times, and in such a manner, as necessary to comply with the effluent limits specified in the NPDES Permit. You are reminded that it is mandatory for the project to be constructed in accordance with the North Carolina Sedimentation Pollution Control Act, and when applicable, the North Carolina Dam Safety Act. In addition, the specifications must clearly state what the contractor's responsibilities shall be in complying with these Acts. Prior to entering into any contract(s) for construction, the recipient must have obtained all applicable permits from the State. Mr. Richard Durham November 26, 2007 Page 3 Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division of Water Quality in accordance with North Carolina General Statute 143-215.6A to 143-215 6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. One (1) set of approved plans and specifications is being forwarded to you. If you have any questions or need additional information, please contact Cecil G Madden, Jr., P.E. at telephone number (919) 715-6203. Sincerely, rVe- Coleen H. Sulli s MM.kp cc: Michael Crowley, P.E. — Crowley & Associates, Inc., Wake Forest Lee County Health Department DWQ Raleigh Regional Office, Surface Water Protection Technical Assistance and Certification Unit Daniel Blaisdell, P.E Point Source Branch, NPDES Program Cecil G. Madden, Jr., P.E Michelle McKay, E.I. ATC File Carolina Trace Utilities A To C No. 03883IA02 November 26, 2007 Engineer's Certification I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the modifications and improvements to the Carolina Trace WWTP, located on NCSR 1221 in Lee County for the Carolina Trace Utilities, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the following construction. Installation of a mechanical bar screen with a bypass to an existing bar screen, one 0.350 MGD circular package plant consisting of a 364,326 gallon aeration basin, two 1,510 cfm blowers, a 36 foot diameter clarifier and a 78,419 gallon aerobic digester, two 124 sqare foot traveling bridge filters, a UV disinfection system consisting of two banks capable of disinfecting 1.75 MGD, and an 18 inch discharge line, in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. I certify that the construction of the above referenced project was observed to be built within substantial compliance and intent of the approved plans and specifications. We understand that the new limits associated with the modifications to expand to .675 MGD now apply. Signature Date Registration No. Send to: Construction Grants & Loans DENR/DWQ 1633 Mail Service Center Raleigh, NC 27699-1633