HomeMy WebLinkAbout19980426 Ver 2_401 Application_20170815ATLANTIC ENVIRONMENTAL CONSULTANTS, LLC
P.O. Box 3266, Kitty Hawk, NC 27949
(252) 261-7707 fax (252) 261-2965
August 7, 2017FK9 ou
1
NC DWR, 401 & Buffer Permitting Unit
AUG 15- 2017
512 North Salisbury Street
Raleigh, NC 27604 of euF ER E M TTIN
RE: John O'Brien — PCN - Nationwide 914
Buxton, Dare County
To whom it may Concern:
Enclosed is a Preconstruction Notification (PCN) Form for a Nationwide# 14 permit to develop a
lot located on Flowers Ridge Road in Buxton, Dare County, North Carolina.
The proposed impact include wetland fill in Section 404 wetlands to construct a single family
residence and driveway. The proposed impacts area associated with a driveway to access an
upland area located on parcel B which is out of the flood zone. As described in the attached PCN
Form several alternatives were explored to reduce wetland impacts as well as minimize impacts
in the Special Environmental District (SED -1) for Dare County Planning. Below are the results
of the two alternatives that were reviewed.
Alternative #1
• Section 404 Wetland Impacts= 1,576 square feet
• Dare Counties SED -1 = 13,841 square feet
Alternative #2
• Section 404 Wetland impacts = 1,356 square feet
• Dare Counties SED -1 = 8,100 square feet
As a result of the above review alternative #2 was chosen. We request that you initiate the
application process and if have questions or need additional information please contact me at 252-
261-7707 or 252-599-2603.
Sincerely,
O �—
g Orman
Atlantic Environmental Consultants, LLC
cc: Josh Pelletier, USACOE
0F W A r�9pG
f
Office Use Only:
Corps action ID no.
DWQ project no.
Form Version 1.3 Dec 10 2008
Pre -Construction Notification PCN Form
A. Applicant Information
1. Processing
1 a. Type(s) of approval sought from the
Corps:
® Section 404 Permit ❑Section 10 Permit
1 b. Specify Nationwide Permit (NWP) number: 14 or General Permit (GP) number:
1 c. Has the NWP or GP number been verified by the Corps?
❑ Yes
® No
1 d. Type(s) of approval sought from the DWQ (check all that apply):
® 401 Water Quality Certification — Regular ❑ Non -404 Jurisdictional General Permit
❑ 401 Water Quality Certification — Express ❑ Riparian Buffer Authorization
1 e. Is this notification solely for the record
because written approval is not required?
For the record only for DWQ 401
Certification:
❑ Yes ® No
For the record only for Corps Permit:
❑ Yes ® No
1f. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation
of impacts? If so, attach the acceptance letter from mitigation bank or in -lieu
fee_p_rograen._
® Yes
❑ No
1 g. Is the project located in any of NC's twenty coastal counties. If yes, answer 1 h
below.
® Yes
❑ No
1h. Is the project located within a NC DCM Area of Environmental Concern (AEC)?
❑ Yes
® No
2. Project Information
2a. Name of project:
O'Brien Property
2b. County:
Dare
2c. Nearest municipality / town:
Buxton
2d. Subdivision name:
Flowers Ridge
2e. NCDOT only, T.I.P. or state
project no:
N/A
3. Owner Information
3a. Name(s) on Recorded Deed:
John O'Brien
3b. Deed Book and Page No.
0597/0843
0528/0567
3c. Responsible Party (for LLC if
applicable):
none
3d. Stree# address:
448 Sooy Place Road
3e. City, state, zip:
Vincentown, NJ 08088
3f. Telephone no.:
609-894-1391
3g. Fax no.:
N/A
3h. Email address:
erinboxers@aol.com
Page 1 of 11
PCN Form — Version 1.3 December 10, 2008 Version
4. Applicant Information (if different from owner)
4a. Applicant is:
® Agent ❑ Other, specify:
4b. Name:
4c. Business name
(if applicable):
4d. Street address:
4e. City, state, zip:
4f. Telephone no.:
4g. Fax no.:
4h. Email address:
S. Agent/Consultant Information (if applicable)
5a. Name:
Doug Dorman
5b. Business name
(if applicable):
Atlantic Environmental Consultants, LLC
5c. Street address:
PO Box 3266
5d. City, state, zip:
Kitty Hawk, NC 27949
5e. Telephone no.:
252-261-7707
5f. Fax no.:
252-261-7707
5g. Email address:
dougdaec@gmaii.com
Page 2 of 11
PCN Form — Version 1.3 December 10, 2008 Version
B. Project Information and Prior Project History
1. Property Identification
1 a. Property identification no. (tax PIN or parcel ID):
053610376061, 053610364937
Latitude: 35.258479 Longitude: - 75.53729
1 b. Site coordinates (in decimal degrees):
(DD.DDDDDD) (-DD.DDDDDD)
1 c. Property size:
Parcel A -1.73 & Parcel B -1.01 acres
2. Surface Waters
2a. Name of nearest body of water (stream, river, etc.) to
Pamlico Sound
proposed project:
2b. Water Quality Classification of nearest receiving water:
SA
2c. River basin:
Pamlico Sound
3. Project Description
3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this
application:
Undeveloped residential lots. Property located in developed residential area of Buxton Woods.
3b. List the total estimated acreage of all existing wetlands on the property:
Parcel A 0.81 acres. Parcel B 0.39 acres
3c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property:
None
3d. Explain the purpose of the proposed project:
A home is to be constructed on the vacant lot and some wetlands need to be crossed to access usuable highground in
flood zone X which would not require flood insurance.
3e. Describe the overall project in detail, including the type of equipment to be used:
Project includes: Fill in two (2) areas of Section 404 wetlands (0.03 ac.). Equipment utilized for this project to include an
excavator or backhoe, a dump truck will bring in fill material. Prior to construction silt fence will be placed at the wetland
interface to prevent intrusion of fill material into wetlands not permitted for fill.
4. Jurisdictional Determinations
4a. Have jurisdictional wetland or stream determinations by the
Corps or State been requested or obtained for this property /
❑Yes ®No El Unknown
project (including all prior phases) in the past?
.
Comments:
4b. If the Corps made the jurisdictional determination, what type
❑Preliminary ®Final
of determination was made?
4c. If yes, who delineated the jurisdictional areas?
Agency/Consultant Company: Atlantic Environmental
Consultants, LLC
Name (if known): Doug Dorman
Other:
4d. If yes, list the dates of the Corps jurisdictional determinations or State determinations and attach documentation.
Kyle Barnes/Krysta Stygar - Metting set to confirm on 4/26/16
5. Project History
5a. Have permits or certifications been requested or obtained for
❑ Yes ® No ❑ Unknown
this project (including all prior phases) in the past?
5b. If yes, explain in detail according to "help file" instructions.
Page 3 of 11
PCN Form — Version 1.3 December 10, 2008 Version
6. Future Project Plans
6a Is this a phased project? ❑Yes ® No
6b. If yes, explain.
Page 4 of 11
. PCN Form — Version 1.3 December 10, 2008 Version
C. Proposed Impacts Inventory
1. Impacts Summary
1 a. Which sections were completed below for your project (check all that apply):
® Wetlands ❑ Streams - tributaries ❑ Buffers
❑ Open Waters ❑ Pond Construction
2. Wetland Impacts
If there are wetland impacts proposed on the site, then complete this question for each wetland area impacted.
2a.
2b.
2c.
2d.
2e.
2f.
Wetland impact
Type of jurisdiction
number -
Type of impact
Type of wetland
Forested
(Corps - 404, 10
Area of impact
Permanent (P) or
(if known)
DWQ - non -404, other)
(acres)
Temporary T
❑Yes
® Corps
0.03
W1 ®P ❑ T
404 wetland fill
Scrub shrub
® No
®DWQ
El Yes
El Corps
W2 ❑ P ❑ T
❑ No
❑ DWQ
El Yes
El Corps
W3 E] P ❑ T
❑ No
❑ DWQ
El Yes
[:1 Corps
W4 ❑ P F-1 T
❑ No
❑ DWQ
El Yes
El Corps
W5 E] P ❑ T
❑ No
❑ DWQ
- -
- - - --
-- - - --
--❑ Yes-- ---
❑-Corps
-E]-Corps-
W6 ❑P❑T
W6
El No
El DWQ
2g. Total wetland impacts
0.03
2h. Comments:
3. Stream Impacts
If there are perennial or intermittent stream impacts (including temporary impacts) proposed on the site, then complete this
question for all stream sites impacted.
3a.
3b.
3c.
3d.
3e.
3f.
3g•
Stream impact
Type of impact
Stream name
Perennial
Type of jurisdiction
Average
Impact
length
number -
(PER) or
(Corps - 404, 10
stream
Permanent (P) or
intermittent
DWQ - non -404,
width
(linear
feet)
Temporary (T)
(INT)?
other)
(feet)
F] PER
❑ Corps
S1 ❑ P ❑ T
❑ INT
❑ DWQ
❑ PER
❑ Corps
S2 ❑ P ❑ T
❑ INT
❑ DWQ
❑ PER
❑ Corps
S3 ❑ P ❑ T
❑ INT
❑ DWQ
-1T
❑ PER
❑Corps
S4 EJP F
❑ INT
❑ DWQ
F1 PER
[:1 Corps
S5 r-1 P ❑ T
❑ INT
❑ DWQ
❑ PER
❑ Corps
S6 ❑ P ❑ T
❑ INT
❑ DWQ
3h. Total stream and tributary impacts
3i. Comments:
Page 5 of 11
PCN Form - Version 1.3 December 10, 2008 Version
4. Open Water Impacts
If there are proposed impacts to lakes, ponds, estuaries, tributaries, sounds, the Atlantic Ocean, or any other open water of
the U.S. then individually list all open water impacts below.
4a.
4b.
4c.
4d.
4e.
Open water
impact number —
Name of waterbody
(if applicable)
Type of impact
Waterbody type
Area of impact (acres)
Permanent (P) or
Temporary T
01 ❑P[IT
02 ❑P❑T
03 ❑P❑T
04 ❑P❑T
4L Total open water impacts
4g. Comments:
S. Pond or Lake Construction
If pond or lake construction proposed, the complete the chart below.
5a.
5b.
5c.
5d.
5e.
Wetland Impacts (acres)
Stream Impacts (feet)
Upland
Pond ID
Proposed use or purpose
(acres)
Flooded
Filled
Excavated
Flooded
Filled
Excavated
Flooded
number
of pond
P1
P2
X Total
5g. Comments:
5h. Is a dam high hazard permit required?
❑ Yes ❑ No If yes, permit ID no:
5i. Expected pond surface area (acres):
5j. Size of pond watershed (acres):
5k. Method of construction:
6. Buffer Impacts (for DWQ)
If project will impact a protected riparian buffer, then complete the chart below. If yes, then individually list all buffer impacts
below. If any impacts require mitigation, then you MUST fill out Section D of this form.
6a.
❑ Neuse ❑ Tar -Pamlico El Other:
Project is in which protected basin?
❑ Catawba ❑ Randleman
6b.
6c.
6d.
6e.
6f.
6g.
Buffer impact
number —
Reason
Buffer
Zone 1 impact
Zone 2 impact
Permanent (P) or
for
Stream name
mitigation
(square feet)
(square feet)
Temporary T
impact
required?
El Yes
B1 ❑P❑T
❑ No
El Yes
B2 ❑P❑T
❑ No
El Yes
B3 ❑P❑T
❑ No
6h. Total buffer impacts
6i. Comments:
Page 6of11
PCN Form — Version 1.3 December 10, 2008 Version
D. Impact Justification and Mitigation
1. Avoidance and Minimization
1 a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing project.
The wetland crossings are located at the narrowest portion of the wetlands that will provide access to the upland area. In
accordance with Dare County Ordinance Section 22-27.3 (e) (1) Special Environmental District (SED -1) standards state that
trees shall not be removed except as necessary for construction (see attached ordinances).The upland area located on Parcel
A directly adjacant to Flowers Ridge Road was previously cleared for a septic system installation and future house
construction. The proposed driveway will provide access for both parcels and utilize an area that has already been cleared.
Having one driveway for both parcels will reduce impacts in the SED -1 zonning. In addition two alternatives were evaluated.
Alternative 1 driveway would go through parcel b and impact 1,576 sf of wetlands. Alternative 2 would impact 1,356 sf of
wetlands. In addition, building in flood zone X will not require flood insurance which will both save a significant amount of
money as well as provide safer location for the residence during storm events.
1 b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques.
Minimum Dare County driveway standards were used to provide access to the upland area which reduced the impacts.
Culverts will be installed to provide connectivity of the existing wetlands. The driveway constrction in alternative 2 will have
less impacts in the wetlands and SED -1 zonning district.
2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State
2a. Does the project require Compensatory Mitigation for
Yes ❑ No
impacts to Waters of the U.S. or Waters of the State?
2b. If yes, mitigation is required by (check all that apply):
® DWQ ® Corps
❑ Mitigation bank
2c. If yes, which mitigation option will be used for this
El to m -lieu fee program
-project? •- --- -- - - - -
_Payment
® Permittee Responsible Mitigation
3. Complete if Using a Mitigation Bank
3a. Name of Mitigation Bank:
3b. Credits Purchased (attach receipt and letter)
Type
Quantity
3c. Comments:
4. Complete if Making a Payment to In -lieu Fee Program
4a. Approval letter from in -lieu fee program is attached.
❑ Yes
4b. Stream mitigation requested:
linear feet
4c. If using stream mitigation, stream temperature:
❑ warm ❑ cool ❑cold
4d. Buffer mitigation requested (DWQ only):
square feet
4e. Riparian wetland mitigation requested:
acres
4f. Non -riparian wetland mitigation requested:
acres
4g. Coastal (tidal) wetland mitigation requested:
acres
4h. Comments:
5. Complete if Using a Permittee Responsible Mitigation Plan
5a. If using a permittee responsible mitigation plan, provide a description of the proposed mitigation plan.
The proposed mitigation will be a 13,600 square foot conservation easement area located on Parcel A. The attached
drawing shows the proposed location.
Page 7 of 11
PCN Form — Version 1.3 December 10, 2008 Version
6. Buffer Mitigation (State Regulated Riparian Buffer Rules) — required by DWQ
6a. Will the project result in an impact within a protected riparian buffer that requires
❑ Yes ® No
buffer mitigation?
6b. If yes, then identify the square feet of impact to each zone of the riparian buffer that requires mitigation. Calculate the
amount of mitigation required.
6c.
6d.
6e.
Zone
Reason for impact
Total impact
Multiplier
Required mitigation
(square feet)
(square feet)
Zone 1
3 (2 for Catawba)
Zone 2
1
1
1.5
6f. Total buffer mitigation required:
6g. If buffer mitigation is required, discuss what type of mitigation is proposed (e.g., payment to private mitigation bank,
permittee responsible riparian buffer restoration, payment into an approved in -lieu fee fund).
6h. Comments:
Page 8of11
PCN Form — Version 1.3 December 10, 2008 Version
E.
Stormwater Management and Diffuse Flow Plan (required by DWQ)
1.
Diffuse Flow Plan
1 a.
Does the project include or is it adjacent to protected riparian buffers identified
❑ Yes ® No
within one of the NC Riparian Buffer Protection Rules?
1 b.
If yes, then is a diffuse flow plan included? If no, explain why.
❑ Yes ❑ No
Comments:
2.
Stormwater Management Plan
2a.
What is the overall percent imperviousness of this project?
3.5%
2b.
Does this project require a Stormwater Management Plan?
❑ Yes ® No
2c.
If this project DOES NOT require a Stormwater Management Plan, explain why: Exisitng residential lot. Stormwater rules
do not apply.
2d.
If this project DOES require a Stormwater Management Plan, then provide a brief, narrative description of the plan:
❑ Certified Local Government
2e.
Who will be responsible for the review of the Stormwater Management Plan?
❑ DWQ Stormwater Program
- - - - - - -
-[-]-DWQ 401 -Unit -
3.
Certified Local Government Stormwater Review
3a.
In which local governments jurisdiction is this project?
Dare County
❑ Phase II
3b.
Which of the following locally -implemented stormwater management programs
❑ NSW
❑ USMP
apply (check all that apply):
❑ Water Supply Watershed
® Other: County Standards
3c. Has the approved Stormwater Management Plan with proof of approval been
❑ Yes ® No
attached?
4.
DWQ Stormwater Program Review
❑ Coastal counties
❑ HQW
4a.
Which of the following state -implemented stormwater management programs apply
❑ ORW
(check all that apply):
❑ Session Law 2006-246
❑ Other:
4b.
Has the approved Stormwater Management Plan with proof of approval been
❑ Yes ❑ No
attached?
5. DWQ 401 Unit Stormwater Review
5a.
Does the Stormwater Management Plan meet the appropriate requirements?
® Yes ❑ No
5b.
Have all of the 401 Unit submittal requirements been met?
® Yes ❑ No
Page 9 of 11
PCN Form - Version 1.3 December 10, 2008 Version
F.
Supplementary Information
1.
Environmental Documentation (DWQ Requirement)
1 a.
Does the project involve an expenditure of public (federal/state/local) funds or the
❑ Yes
® No
use of public (federal/state) land?
1 b. If you answered "yes" to the above, does the project require preparation of an
® No
environmental document pursuant to the requirements of the National or State
❑ Yes
(North Carolina) Environmental Policy Act (NEPA/SEPA)?
1 c.
If you answered "yes" to the above, has the document review been finalized by the
State Clearing House? (If so, attach a copy of the NEPA or SEPA final approval
El Yes
®No
letter.)
Comments:
2.
Violations (DWQ Requirement)
2a.
Is the site in violation of DWQ Wetland Rules (15A NCAC 2H .0500), Isolated
Wetland Rules (15A NCAC 2H .1300), DWQ Surface Water or Wetland Standards,
❑ Yes
® No
or Riparian Buffer Rules (15A NCAC 2B .0200)?
2b.
Is this an after -the -fact permit application?
❑ Yes
® No
2c.
If you answered "yes" to one or both of the above questions, provide an explanation of the violation(s):
3.
Cumulative Impacts (DWQ Requirement)
3a.
Will this project (based on past and reasonably anticipated future impacts) result in
❑ Yes
® No
additional development, which could impact nearby downstream water quality?
3b.
If you answered "yes" to the above, submit a qualitative or quantitative cumulative impact analysis in accordance with the
most recent DWQ policy. If you answered "no," provide a short narrative description.
4.
Sewage Disposal (DWQ Requirement)
4a.
Clearly detail the ultimate treatment methods and disposition (non -discharge or discharge) of wastewater generated from
the proposed project, or available capacity of the subject facility.
Conventional septic sytem.
Page 10 of 11
PCN Form — Version 1.3 December 10, 2008 Version
S. Endangered Species and Designated Critical Habitat (Corps Requirement)
5a. Will this project occur in or near an area with federally protected species or
❑ Yes ® No
habitat?
5b. Have you checked with the USFWS concerning Endangered Species Act
® Yes ❑ No
impacts?
® Raleigh
5c. If yes, indicate the USFWS Field Office you have contacted.
❑ Asheville
5d. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical
Habitat?
Contacted Raleigh USFWS office.
6. Essential Fish Habitat (Corps Requirement)
6a. Will this project occur in or near an area designated as essential fish habitat?
❑ Yes ® No
6b. What data sources did you use to determine whether your site would impact Essential Fish Habitat?
The wetland area would not support Essential Fish Habitat.
7. Historic or Prehistoric Cultural Resources (Corps Requirement)
7a. Will this project occur in or near an area that the state, federal or tribal
governments have designated as having historic or cultural preservation
❑ Yes ® No
status (e.g., National Historic Trust designation or properties significant in
North Carolina history and archaeology)?
7b. What data sources did you use to determine whether your site would impact historic or archeological resources?
Contacted State Archeologist for an Environmental Review determation.
8. Flood Zone Designation (Corps Requirement)
8a. Will this project occur in a FEMA -designated 100 -year floodplain?
❑ Yes ® No
8b. If yes, explain how project meets FEMA requirements:
8c. What source(s) did you use to make the floodplain determination? Dare County flooplain maps and recent elevation
survey.
Doug Dorman
8/1/17
Applicant/Agent's Printed Name
Date
v pplicant/Agent's Signature
(Agent's signature is valid only if an authorization letter from the applicant
isprovided.)
Page 11 of 11
PCN Form — Version 1.3 December 10, 2008 Version
7/10/2017
American Legal Publishing - Online Library
SECTION 22-27.3 - SED - 1 SPECIAL ENVIRONMENTAL DISTRICT'`
(a) Intent. The specifications and standards of the SED -1 Zoning District are established in order to protect
public health and welfare, to preserve the quality of the fresh water supply aquifer which lies beneath the Buxton
Woods Forest, to provide an environmentally compatible setting for low density residential housing, and to
preserve the economic, aesthetic, and unique and irreplaceable natural resource assets of the land, vegetation,
surface waters, and underground waters of this district.
(b) Permitted uses. The following uses shall be permitted by right:
(1) Detached single-family residential structures.
(2) Duplex (2 family) structures.
(3) Customary accessory buildings.
(4) Publicly owned nature preserves or parks.
(5) County owned or leased facilities.
(6) Publicly and/or privately owned water distribution systems and all associated underground fixtures
including production wells.
(8-19-91)
(7) Mobile homes located on individual parcels or lots provided the mobile home meets the wind zone III
standards (constructed after July 13, 1994) as defined in Chapter 156of the Dare County Code of Ordinances.
(This use added on February 20, 2006)
(c) Conditional uses: The following uses may be permitted subject to the requirements of this district and
additional regulations and requirements imposed by the Board of Commissioners as provided in Article X:
(1) Wastewater treatment facilities.
(2) Publicly and or privately owned water production facilities and all associated improvements that are
located above ground, including elevated and/or ground level storage tanks.
(8-19-91)
(3) Family child care homes as defined in Section 22-2 and subject to the provisions of Section 22-29.1.
(Adopted 11-5-90; amended 5- 16-11)
(4) Residential child care centers.
(d) Dimensional Requirements:
(1) Minimum lot size:
a. Single-family detached residence: 40,000 square feet.
b. Duplex lot: 80,000 square feet.
c. Cluster lot: 160,000 or greater square feet, which may be developed at a dwelling density of one unit
per 40,000 square feet of land area (or 4 single family structures per cluster lot) provided that the structures are
located on the lot in such a manner that development and land clearing activities are remote from any wetland,
swale, or pond, and that any associated clearing does not exceed 20% of the lot if the total lot area. Cluster lots
may be recorded at the prescribed minimum or may be the result of a recombination of previously recorded lots,
that, when combined, equal a total of 160,000 or greater square feet.
http://library.amlegal.com/nxVgateway.dl[/North%2OCarolina/dareco_nc/darecountynorthcarolinaeodeafordinances?f=templates$fn=default.htm$3.0$vid... 1/4
7/10/1017 American Legal Publishing - Online Library
(2) Minimum lot width: Measured at the building line.
a. 40,000 - 59,999 square foot lots = 100 feet.
b. 60,000 - 79,999 square foot lots = 150 feet.
c. 80,000 or greater square foot lots = 200 feet.
(3) Setbacks
a. Front yard
(1) lots with 100 feet of depth - 25 feet.
(2) lots with 101-150 feet of depth - 35 feet.
(3) lots with 151 or more feet of depth - 50 feet.
b. Side Yard
(1) lots with 100-149 feet of width - 20 feet.
(2) lots with 150 - 199 feet of width - 30 feet.
(3) lots with 200 or more feet of width - 50 feet.
(4) Cluster lots - 40 feet between clustered structures or 20 feet of side yard for each structure.
c. Rear yard
(1) lots with 100 feet of depth - 25 feet.
(2) lots with 101-150 feet of depth 35 feet.
(3) lots with 151 or more feet of depth - 50 feet.
(4) Building Height Limit - Rooflines, measured at the peak, shall not extend more than 35 feet above the
average grade within a 50 -foot perimeter around the structure.
(5) Maximum lot coverage by principal use structure and any accessory use structures or improvements
combined.
a. Lots with a total area of 40,000 - 59,999 square feet - 35%.
b. Lots with a total area of 60,000 - 79,999 square feet - 30%.
c. Lots with a total area of 80,000 or more square feet - 25%.
d. Lots used as cluster sites - 20%.
(e) Special SED -1 Standards.
mite alteration shall not occur prior to the issuance of a building permit unless otherwise authorized.
Trees shall not be removed except as necessary for the construction of the principal structure, accessory use,
parking area, driveway access and septic tank/nitrification field system. Land disturbing activities and site
alteration shall not exceed the minimum necessary to provide for the location of the principal use structure, any
accessory use improvements, driveway access, and utility service improvements, such as nitrification fields.
(2) Off-street parking, driveways, and carports: All off-street parking improvements, drive -ways, and
carports shall be designated to minimize impervious lot coverage and shall be constructed of only the following
materials, clay, stone, marl, gravel, river -rock, or semi -porous paving block. Each principal use structure shall be
allowed to install 1,000 square feet of concrete or asphalt parking or accessory use area.
http://library.amlegal.com/nxtlgateway.dll/North%20Carolina/dareco_nc/darecountynorthcarolinacodeofordinances?f=templates$fn=default. htm$3.0$vid... 2/4
7/10/2017
American Legal Publishing - Online Library
(3) Wetland buffer. Existing natural wetlands, ponds, and wetland swales shall not be dredged, filled or
otherwise altered from their natural state. No structure, paved area, or any part of a ground absorption
wastewater treatment system shall be located within 50 feet of any marsh, stream, pond, or wetland. Minor road
crossing fill for property access shall be allowed only as authorized under the jurisdiction of the Army Corps of
Engineers specifications for access roads.
a. Inter -connecting roads exempt. Subdivision roads that follow the alignment of existing inter-
connecting roads along any ridge-swale formation shall not be located within 10' of any wetland, pond, or
wetland swale provided such roads do not exceed 20' in pavement width.
(4) Right-of-way and pavement width specifications: Right-of-way and pavement width specifications.
Right-of-way widths shall not exceed 45 feet including land cleared for shoulders and drainage, pavement width
shall not exceed 30 feet. Curb and gutter drainage systems shall not be installed in the SED -1 zoning district.
(f) Site Plan Review Requirements: All development projects and land disturbing activities in the SED -1
zoning district shall submit, in conjunction with the building permit application, a site plan prepared and sealed
by a North Carolina registered land surveyor or engineer, which shall include the following information:
(1) Subdivision plats of greater than 20 lots shall indicate the location of a groundwater monitoring well
location site on the subdivision plat.
(2) Present recorded owner and map book reference and subdivision title of the site property.
(3) Boundary of the entire lot by course and distance.
(4) Width and location of the existing rights-of-way.
(5) Nature or purpose, location and size of existing easements.
(6) Iron pins, three-eighths inches in diameter and thirty-six inches in length shall be shown and installed at
all lot corners, points of tangents and any angle point along a given course of the lot.
(7) Plan drawn to at least one inch equals one- hundred -foot scale showing north arrow.
(8) Site zoning.
(9) Streets showing the width of pavement within the boundaries of the project site.
(10) All other underground utilities and facilities.
(11) Proposed building type (brick or frame), number of floors and dimensions.
(12) Proposed front elevation and first floor elevation.
(13) Location and type of all sidewalks and driveways within the site.
(14) Percentage of land disturbing activity.
(15) Location of sanitary sewer facilities with connection to sewer system or septic tank.
(16) Finished grades shall be shown for the entire site.
(17) An inventory of all trees of a caliper greater than 4", those existing and those to be removed.
(18) Dimensions and square footage of lot or lots to be developed.
The site plan for all proposed development projects to be located in the SED -1 Zoning District shall be
submitted to the office of the Building Inspector not less than five working days prior to the date site preparation
and/or construction is to begin. The building inspector and/or zoning administrator shall visit each site prior to
the authorization of any construction or land disturbing activity. At the discretion of the building inspector
and/or zoning administrator, an additional five working day review period may be required in order for
http://library.amlegal.com/nxtlgateway.dll/North%20Carolina/dareco_nc/darecountynorthearolinacodeofordinances?f=templates$fn=default. htm$3.0$vid... 3/4
7/19/2017
American Legal Publishing - Online Library
additional information to be gathered or for independent review to occur. Upon the expiration of the seconded
optional review period, the building inspector shall either authorize the construction or deny authorization for
the same.
(g) Non -conforming lots. Lots recorded or approved preliminarily by the Board of Commissioners prior to
February 8, 1988 shall be considered pre-existing, non -conforming lots and shall be subject to the following
guidelines:
(1) Setbacks
a. Lots with 99 or less feet of width:
(1) Front - 30 feet.
(2) Side - 10 feet.
(3) Rear - 20% of total depth or 20 feet whichever is less.
b. Lots with 100 feet or more of width:
(1) Front - 30 feet.
(2) Side - 12 feet.
(3) Rear - 20% of total depth or 20 feet, whichever is less.
(2) Maximum lot coverage by principal use structure and any accessory use or structure.
a. Lots with 39,999 - 30,0000 square feet - 30%.
b. Lots with 29,999 - 20,000 square feet - 35%.
c. Lots with 19,999 square feet or less - 35%.
(3) Site alteration and vegetation removal - same as section e, (1).
(4) Off-street parking, driveways, and carports: Same as section e, (2) including the 1,000 square foot
asphalt and concrete exemption.
(5) Site plan review: Same as section f, (1) - (7)
(Adopted March 21, 1988 by the Dare County Board of Commissioners.)
ZONING AMENDMENT - BUXTON WOODS
This zoning amendment was adopted by the Dare County Board of Commissioners on September 19, 1988.
All land located between the center line of the intersection of NC 12 and Billy Mitchell Airport Road, and the
center line of the intersection of NC 12 and Cape Hatteras Lighthouse Road, for a distance of 1/2 mile north
(meg. 1988) from an SED -1 District shall be subject to the following additional requirements:
Dwelling density within the zone of influence of the SED Ordinance: No multi -family development,
townhouses, or condominium project located with 1/2 mile of any SED -1 zoning district shall exceed a
dwelling density of three single family units (whether contained under one or more roofs) per acre or usable
land area. Usable land shall be that land defined as "suitable" for septic tank/nitrification field wastewater
disposal by the U.S. Department of Agriculture/Soil Conservation Service Soil Survey for Dare County and the
Dare County Board of Health.
Vegetation Removal: All subdivision, and all development projects within 1/2 mile of an SED -1 zoning district
which are subject to site plan review, shall conform to the land clearing provisions of the SED Zoning District,
Section 22-27.3(e) (1) - Site Alteration.
http://I ibrary.amlegal.com/nxVgateway.dil/North%2OCarolina/dareco_nc/darecountynorthcarolinacodeofordinances?f=templates$fn=default. htm$3.0$vid... 4/4
U.S. ARMY CORPS OF ENGINEERS
WILMINGTON DISTRICT
Action Id. SAW -2016-00851 County: Dare U.S.G.S. Quad: NC -BUXTON
NOTIFICATION OF JURISDICTIONAL DETERIMIINATION
Property Owner: John J. O'Brien
Address: 448 Soov Place Road
Vincentown, NJ, 08088
Telephone Number: (609) 894-1391
Size (acres) 2.96
Nearest Waterway Pamlico Sound
USGS HUC 03020105
Nearest Town Buxton
River Basin Pamlico
Coordinates Latitude: 35.258421
Longitude: -75.537389
Location description: Property is a residential 2.96 acre lot subdivided into Parcel A (1.86 acres) and Parcel B (1.1 acre)
located at 46657 Flowers Ridge Road, Buxton, Dare County, North Carolina.
Indicate Which of the Following Apply:
A. Preliminary Determination
There are waters, including wetlands, on the above described project area, that may be subject to Section 404 of the
Clean Water Act (CWA)(33 USC § 1344) and/or Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403). The
waters, including wetlands, have been delineated, and the delineation has been verified by the Corps to be sufficiently
accurate and reliable. Therefore this preliminary jurisdiction determination may be used in the permit evaluation process,
including determining compensatory mitigation. For purposes of computation of impacts, compensatory mitigation
requirements, and other resource protection measures, a permit decision made on the basis of a preliminary JD will treat all
waters and wetlands that would be affected in any way by the permitted activity on the site as if they are jurisdictional
waters of the U. S. This preliminary determination is not an appealable action under the Regulatory Program
Administrative Appeal Process (Reference 33 CFR Part 331). However, you may request an approved JD, which is an
appealable action, by contacting the Corps district for further instruction.
There are wetlands on the above described property, that may be subject to Section 404 of the Clean Water Act
(CWA)(33 USC § 1344) and/or Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403). However, since the
waters, including wetlands, have not been properly delineated, this preliminary jurisdiction determination may not be
used in the permit evaluation process. Without a verified wetland delineation, this preliminary determination is merely an
effective presumption of CWA/RHA jurisdiction overall of the waters, including wetlands, at the project area, which is
not sufficiently accurate and reliable to support an enforceable permit decision. We recommend that you have the
waters of the U.S. on your property delineated. As the Corps may not be able to accomplish this wetland delineation in a
timely manner, you may wish to obtain a consultant to conduct a delineation that can be verified by the Corps.
B. Approved Determination
_ There are Navigable Waters of the United States within the above described property subject to the permit requirements of
Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403) and Section 404 of the Clean Water Act (CWA)(33 USC
§ 1344). Unless there is a change in law or our published regulations, this determination may be relied upon for a period
not to exceed five years from the date of this notification.
X There are wetlands on the above described property subject to the permit requirements of Section 404 of the Clean Water
Act (C WA) (33 USC § 1344). Unless there is a change in the law or our published regulations, this determination may be
relied upon for a period not to exceed five years from the date of this notification.
_ We recommend you have the waters of the U.S. on your property delineated. As the Corps may not be able to
accomplish this wetland delineation in a timely manner, you may wish to obtain a consultant to conduct a delineation that
can be verified by the Corps.
Page 1 of 2
_ The waters of the U.S., including wetlands, on your project area have been delineated and the delineation has been
verified by the Corps. If you wish to have the delineation surveyed, the Corps can review and verify the survey upon
completion. Once verified, this survey will provide an accurate depiction of all areas subject to CWA and/or RHA
jurisdiction on your property which, provided there is no change in the law or our published regulations, may be relied
upon for a period not to exceed five years.
X The wetlands have been delineated and surveyed and are accurately depicted on the plat signed by the Corps
Regulatory Official identified below on October 26, 2016. Unless there is a change in the law or our published
regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification.
_ There are no waters of the U.S., to include wetlands, present on the above described project area which are subject to the
permit requirements of Section 404 of the Clean Water Act (33 USC 1344). Unless there is a change in the law or our
published regulations, this determination may be relied upon for a period not to exceed five years from the date of this
notification.
X The property is located in one of the 20 Coastal Counties subject to regulation under the Coastal Area Management Act
(LAMA). You should contact the Division of Coastal Management in Morehead City, NC, at (252) 808-2808 to determine
their requirements.
Placement of dredged or fill material within waters of the US, including wetlands, without a Department of the Army permit
may constitute a violation of Section 301 of the Clean Water Act (33 USC § 1311). Placement of dredged or fill material,
construction or placement of structures, or work within navigable waters of the United States without a Department of the
Army permit may constitute a violation of Sections 9 and/or 10 of the Rivers and Harbors Act (33 USC § 401 and/or 403). If
you have any questions regarding this determination and/or the Corps regulatory program, please contact
Krystvnka.b.styagrnu,usace.armv.mil or (910)251-4619.
C. Basis for Determination: This site exhibits wetland criteria as described in the 1987 Corns Wetland
Delineation Manual and Atlantic and Gulf Coast Supplement and is part of a broad continuum of wetlands
connected to the Pamlico Sound a Traditional Navigable Water.
D. Remarks: Please see attached Plats
E. Attention USDA Program Participants
This delineation/determination has been conducted to identify the limits of Corps' Clean Water Act jurisdiction for the
particular site identified in this request. The delineation/determination may not be valid for the wetland conservation
provisions of the Food Security Act of 1985. If you or your tenant are USDA Program participants, or anticipate participation
in USDA programs, you should request a certified wetland determination from the local office of the Natural Resources
Conservation Service, prior to starting work.
F. Appeals Information (This information applies only to approved jurisdictional determinations as indicated in
B. above)
This correspondence constitutes an approved jurisdictional determination for the above described site. If you object to this
determination, you may request an administrative appeal under Corps regulations at 33 CFR Part 331. Enclosed you will find a
Notification of Appeal Process (NAP) fact sheet and request for appeal (RFA) form. If you request to appeal this
determination you must submit a completed RFA form to the following address:
US Army Corps of Engineers
South Atlantic Division
Attn: Jason Steele, Review Officer
60 Forsyth Street SW, Room IOM15
Atlanta, Georgia 30303-8801
In order for an RFA to be accepted by the Corps, the Corps must determine that it is complete, that it meets the criteria for
appeal under 33 CFR part 331.5, and that it has been received by the Division Office within 60 days of the date of the NAP.
Should you decide to subrnit an RFA form, it must be received at the above address by December 26, 2016.
**It is not necessary to submit an RFA form to the Division Office if you do not object to the determination in this
correspondence. **
Ngttaly slgwd by
STYGAR.KRSTYNKA.B W; C^US a=U.$.K"GoVenvne t, �DoD,o -0K1,
Corps Regulatory Official: ETHANIE.1408680430 c=STYGAR.KRSTYNKA.SETHANIE.1409680430
Date: October 26, 2016 'Expiration Date: October 26.2021
The Wilmington District is committed to providing the highest level of support to the public. To help us ensure we
continue to do so, please complete our Customer Satisfaction Survey, located online at
http:Hcorl2smapu.usace.army.mil/cm apex/f?2=136:4:0.
Copy Furnished:
Doug Dorman
PO Box 3266
Kitty Hawk. NC 27949
WETLAND SURVEY FOR
JOHN J. O'BRIEN
PARCELA
46657 FLOWERS RIDGE ROAD
BUXTON, NC 27920
wnship County State
I,TTERAS DARE N.C.
ite File Number Scale
/25/2016 5171-WSX 1" = 60'
ircel Number I Average Ground Elev
?corded Reference
3 528, Pg 567
ming Pin Number
-E NOTE 2 102 0536 10 <
IRM ZONE DATA F.I.R.M.
_
A E & X
se Flood Elevation I Communil
FB/Pg
LEGEND
i, rreoay u. nanKm, I'La, canny met ims survey is or
an existing parcel or existing parcels of land and does
❑ EXISTING CONCRETE MONUMENT
I not create a new street or change an existing street.
O EXISTING IRON STAKE
r
* FIRE HYDRANT
CIO
® UTILITY POLE
Freddy Rankin, PLS, L-2958
O PED -LOCK
-�
404 POINT
'
-
,,.- --- UNIMPROVED ROAD N �r,
............ e -'
--N 88°9 3 5Y" € =3- 1-34.72'
'
1B � pE'LYddO "` 38
based upon recorded bearing S 3°02'33'
E for line A -B per DB 597, Pg 843.
_
�93?,.51 sl ft / {ptf1ELD
NOTES:
5B
1. This survey is subject to any facts
flood hazard area as designated on
that may be disclosed by a Rill and
N
accurate tide search.
CIO
2. This lot is a nonconforming SED -1 lot
o u?
of record platted prior to February 8,
cQ
1988.
46
3. Survey based upon physical evidence
(1%) or greater chance of being flooded
found as shown. Meridian for survey
' °H9
based upon recorded bearing S 3°02'33'
E for line A -B per DB 597, Pg 843.
26A X25,
4 This lot is located in the Wind -Rome
Debris Re i
required by lending institutions
Nmo BRP \
� AREA
60 5040 30 010 0 60
A I R (per
17s.as'
i60 2 �� Np9367 -~`
N �-
PARCEL B
iC WETLAND CERTIFICATION
X SAMPLING % This certifies that this copy of this plat accuratelynoir 2C depicts the boundary of the jurisdiction of the section i
HIGHLAND WETLAND C
14- g 404 of the clean water ad under the p
25,073.35 sq ft 3,157.86 sq R resent law and
4C regulations as determined by the undersigned on this
_ '11C w date. Unless there is a change in the law or our I
�.
7RMZpNE 5C 6C
23A�, 19A �7Rlvj2pAiE�_ _- 7C
-� 18A 4E6'
24A 22A�'
21A"-, /
,120A 17A�`-_.._�_
16A 15A`-.�
' 14A
g on
5
5. Some portions of some lots in tl s .T H14 H13� PARCEL A
NAD83 subdivision are located in Areas 1
Environmental Concern. Individual H17 H15 -- H12 1.73 acres
permits may be required beforeZ H1s 75,142.96 sq ft
H11
development may take place in these N A, - x s MPL°ac
areas
i �
CT PON -
Freddy D. Rankin, Professional Land
Surveyor, certify that this plat was drawn
rom an actual field land survey and that the
,rror of closure as calculated by latitudes
ind departures is at least 1:10,000.
Nitness my hand and seal this 25th day of
July , A.D. 2016 .
�__,�_ .
=reddy . Rankin, P.L.S., L-2958
6. This properly, or portions of this
property, are located within special
cn
HIGHLAND H WETLAND y.
31,62048 sq R
flood hazard area as designated on
`L
10,236.70 sq ft
Flood Insurance Rate Maps for Dare
I s
FF7R/Kp NY-
R4/IO
in a special
m`�o�
' H70 �qF
haCounzard a area retion
presents esents percent
46
BC
(1%) or greater chance of being flooded
11A
' °H9
in any given year. Flood insurance may
be for
o m
H5 - H4
HB, - --- 17D
required by lending institutions
�m
N25°51'40'W
structures constructed on property
~
H7 ,/ -H6
• �
located in special flood hazard areas.
19A
\ 1'
148.60' H3 66.7t'
------� -'-"--
DEER $
b
293.08' S 88°17'08" W
BUXTON,NC
Freddy D. Rankin, PLS MI 212UGE1
0232 S. Buccaneer Dr., PO Box 121
Frisco, NC 27936-0121
(252)995-4405 Fax(252)995-5580 LOCATION
o
i CK ROAa
Nounu.n,,
,(N CAR "o„
O O�j
11A
12A
13A
12A
13A
14A
S72°20'25'W
S 61°23'40" W
S69°51'38 W
13.09'
30.68
2434'
a - z
I s
FESS/
�,QQP
14A
15A
15A
16A
N62°09'03'W
S85°4813'W
24.13'
3269
46
BC
16A
11A
N75°2fr0W
30.66'
IIAm
-
SEAL
11A
IIIA
N25°51'40'W
26.53'
°
L 2958 c
18A
19A
S 86°4To7' W
16.47'
DEER $
b
'C1 r O:
"=
19A
20A
S34°3820'W
30.04'
RUN
G'RGLE z
�ij�pSURJ�°` �\,r
„ �
20A
21A
21A
22A
N56°1922 W
N74°35'09'W
26.36'
30.77
ER
4G
3G_ __ _ _
22A
23A
N41°11'06'W
1843'
SITE
S46°15'49 E
23A
24A
S 52°2759" W
2367'
16.10
9C
24A
25A
S 22°20'09' W
3834'
9C
From
published regulations, this determination of section
z
From
9D
a - z
404 jurisdiction maybe relied upon for a period not to �
23.1810D
1oC w
W o
exceed five years from this date. This determination
z I
46
BC
-
was made utilizing the 1987 Corps of Engineers
m
S69°15'33'W
IIAm
-
o o
W
Wetland Delineation Manual
c3
18D
12A
m
Name: STYGAR.KRSTYN
26.45'
OG
Gi
z
KA.BETHANIE14 (;,,..
oI
awl
13A
G2
Title'. nssfiaoaRnm
_
I
rn
a
9D
G2
Date: SAW -2016651
I
23.20'
4G
3G_ __ _ _
7C
S 81°44'53' E
16.18'
m
i o
r
S46°15'49 E
23.55'
8C
i
2G�' 2,092.48sgIt
cp
HWIILANUGJ,,
From
To Beano
Distance
From
9D
10D
N 64°2827'W
23.1810D
3B
S 89.3852' E
IIID
S19°3T31'W18.74'
46
S19*311TW
1G
16D
ND
S69°15'33'W
40.86
58
66
17D
18D
S 6°44'03 W
177
S66°1806'W
26.45'
OG
Gi
N60°27'15°W
30.6G1
3C
4C
S 52°5833 W
G2
N42°16'55°W
3516'16D;
S37°15'44`W
9D
G2
G3
N28°26'10"E
23.20'
6C
7C
S 81°44'53' E
16.18'
7C
8C
S46°15'49 E
HIGHLAND D G,
2,369.57 sq R PARK SERVICE 1
77.77' B 81.73MONUMENT___ 93.34--
NIF
175.07' -°� S 89°09'34" W TIE LINE o --
U.S. GOVERNMENT
Dg "A", Pg 261
From
WETLAND
&C'DATA
Distance
From
ToBearin
S88°55'18"W
Distance
2B
3B
S 89.3852' E
26.39
3B
46
S19*311TW
16.49
48
513
S 79°5437 W
24.94
58
66
N66°11'52 W
6.77'
iC
2C
S66°1806'W
26.45'
2C
3C
S 87'01'40"W
33.04
3C
4C
S 52°5833 W
26.89
4C
5C
S37°15'44`W
20.39'
5C
6C
N 87°17'51" E
17.54
6C
7C
S 81°44'53' E
16.18'
7C
8C
S46°15'49 E
23.55'
8C
9C
N 25.0847" E
16.10
9C
10CS
77°5835` E
25.88
From
To
Bearing
Distance
H4
H5
S88°55'18"W
51,45'
H5
H6
S64.34'l2'W
29.99
H6
H7
S85.55'20'W
37,58
Hl
HB
N49'05'1I'E
1934.
H8
H9
N63'0013'E
27.24
H9
H10
N 392n8" E
28.38
H10
H11
N37°3T58'E
49.2T
Hll
H12
N26°03'41"W
11.34
H12
H13
N76°5929'W
21.15'
H13
H14
S84°4849'W
25.59
H14
H15
S77.0933'W
19.01'
H15
Hill
S83.3844'W
25.91'
WETLAND / SURVEY FOR
JOHN J. O'BRIEN
PARCELB
46611 FLOWERS RIDGE ROAD
BUXTON, NC 27920
)wnship County State
%TTERAS DARE N.C.
ate File Number Scale
725/2016 5172-WSX 1" = 60'
arcel Number I Average Ground Elev.
ecorded Reference FB/Pg
3 597, P9 843 173/55
ming Pin Number NAD83
EE NOTE 3 02 0536 10 37 6061
'IRM ZONE DATA F.I.R.M. Zone
AE&X
ise Flood Elevation ICommunity/Panel/Suffix
(AE) & N/A (X) 1 375348 0536 J
I, Freddy D. Rankin, Professional Land
Surveyor, certify that this plat was drawn
from an actual field land survey and that the
error of closure as calculated by latitudes
and departures is at least 1:10,000.
Witness my hand and seal this 25th day of
,may _, A.D. 2016 .
Freddy . Rankin, P.L.S., L-2958
Freddy D. Rankin, PLS
0232 S. Buccaneer Dr., PO Box 121
Frisco, NC 27936-0121
(252) 995-4405 Fax (252) 995-5580
LEGEND
O EX STING CONCRETE MONUMENT
O EXISTING IRON STAKE
® FIRE HYDRANT _ 16 '
�a�� 22 ! A 179.48'�\R W (Per
® UTILITY POLE DB 28-��
160 • � 5, P9.567}
CA PFrI-IOCK - v �a v " ��_N80-
2 07
" , _ _— „ E -- v ° _ v
404 POINT
_ U_NIMPROVED ROAD , � N 16`55�9 `v
1C HIGHLAND
1 NT v —N 88°'13'52 " _iii- 14.72OC A 15,56385sgR 2
12C x sa�uNc L
4 NOTES 03549D R _ _ _ POINT _ _ 3/WE5T2LAAND�
1. This survey is subject to any facts that maybe a — r
disclosed by a full and accurate the search.C/o Nx 11 C 6A 4
2. Minimum Building Lines (MBL) shown hereon w 7A I,
WETLAND CERTIFICATION I roust be verified. The surveyor makes no certification eX o 1oC
This certifies that this copy of this plat r as to zoning and/or restrictive covenant setbacks.pIR E AE W w
R
accurately depicts the boundary of the
3. This lot Is a nonconforming SED -1 lot of record
EI
w *
1L 5A ----_ / 3A
jurisdiction of the section 404 of the
platted prior to February 8,1988.
based found
SEAL
M 1
?2? l IA
1 aA ,I
J -
2A "
clean water act under the present law 1
4 Survey upon physical evidence as
<
shown. Meridian for survey based upon recorded _
<
�'',p ,"�`�•`���+
� �O yrDrrrr"`"'
`
'1rATK)N.CKFTrN NOTTn c I C
8A
1
and regulations as determined by the
bearing S 3°02'33' E for line per Pg 843.
o ?
o
! -
`10A - 9A
__
PARCEL B
undersigned on this date. Unless
9 I
a Debris
5. This lot is located in the Wind Borne Debris
ind
l
N z
1.06 acres
there is a change in the law or our , N
Region j
°' `-
-� 'L
46,123.80 scl ft
published regulations, this N
7. Some portions of some lots in This subdiv s on are 1 !
o o
X
determination of section 404 0
located in Areas of Environmental Concern.
aG
-'
jurisdiction may be relied Upon fora I T;,
Individual pennitsmay be required before
z
3G 5G
=
period not to exceed five years from
this date. This determination was
development may take place in these areas. a
8. This property, or portions of this property, are
HIGHLAND G 7
N 1,65516 s R 7
g
L. - " WETLAND AD =I-
—
1 15,037.35 sqR
z� o
made utilizing the 1987 Corps of I
ocated within a special Good hazard area as
designated on Flood Insurance Rafe Maps for Dare mo
PARCEL A
/
� o
_ _-_ - 3D
'" 5D 4D
iF
Engineers Wetland Delineation
County Location in a special flood hazard area
CD T 8C�
6D
Manual represents a one percent (1%) or greater chance of /..
N being flooded in any given year. Flood insurance
Name: ST GAR KRSTw° :^ff,ww<,w I oAo may be required by lending institutions for structures
9G % 7G
YNKA.BETHAN °�° constructed on propertylocated in special Rood 1 90 `84L
Title: ""°" """° "" I hazard areas. p tJ
°° I F�PM�tiO �80
Date:
I "' 158.63' - B
I 134.45'
293.08'
N/F I, Freddy D. Rankin, PLS, certify that this
CAPE HATTERAS NG,z U.S. GOVERNMENT
rcuryIs of an existing arca/ or existing
_� SCHOOL o q 261 9 p 9
6*DB "A" P
b parce �s of land and does not create a new
T ACK ROAD skeet or change an existing street.
!2F �.
HIGHLAND DF 3F
11, 718.41 sq R
PARK
N 89°09'34" E 175.07'
60 50 40 30 2010 0 60
rreoay D.ttanKin, rLJ, L [YJ0 -21� 3F 2F S 61°3224' E 15.64'
2A 3A N 69°2700' W 25.54' 2F 1F S 40.46'09' W 30.34
rom To Bearing Distance 3A 4A S 83.3851' W 19.50 1F ID N 5°41'11' E 11.95
a 4A 5A N 18°2704' W 34.18 10 2D N 79°25'15' W 21.37
2 3 S 69°08'03, W 32.24' 5A 6A N 8°01'56 W 27.58' 20 3D S 55°2('51" W 21.79'
3 4 S 46.14'55' E 24.79' 6A 7A S 81°10'25' W 9.13' 3D 4D S 78°55'43' W 31.67
4 5 N 79°00'56" E 34.97 7A 8A S 6'53'28'W 35.65' 4D 5D S 87'1725" W 23.98'
10C I Ic N 50°2608' E 16.15' 8A 9A S 55°25'41' W 26.57' 5D 6D S 74°2616" W 19.49'
i1C 12C N65°10'1TE 34.41' 9A 10A S80°04'08'YU 23.21' 6D 7D S45'00'42"W 24.69'
12 CIC N61°3Y34'W 46AIT 10A 11A N38°1509'W 17.54 iD BD S24°41'16'W 36.10
NRO
BUXTON, NC
��CA
CROOKED RIDGE TRAIL
SEAL
)DUE RIDGE TRAIL rr5EER
RUN
L-2958
J CIRCLE m
'�$UR`t�"""
FLOWER
RIDGE SITE)
<
�'',p ,"�`�•`���+
� �O yrDrrrr"`"'
`
'1rATK)N.CKFTrN NOTTn c I C
" ,
!2F �.
HIGHLAND DF 3F
11, 718.41 sq R
PARK
N 89°09'34" E 175.07'
60 50 40 30 2010 0 60
rreoay D.ttanKin, rLJ, L [YJ0 -21� 3F 2F S 61°3224' E 15.64'
2A 3A N 69°2700' W 25.54' 2F 1F S 40.46'09' W 30.34
rom To Bearing Distance 3A 4A S 83.3851' W 19.50 1F ID N 5°41'11' E 11.95
a 4A 5A N 18°2704' W 34.18 10 2D N 79°25'15' W 21.37
2 3 S 69°08'03, W 32.24' 5A 6A N 8°01'56 W 27.58' 20 3D S 55°2('51" W 21.79'
3 4 S 46.14'55' E 24.79' 6A 7A S 81°10'25' W 9.13' 3D 4D S 78°55'43' W 31.67
4 5 N 79°00'56" E 34.97 7A 8A S 6'53'28'W 35.65' 4D 5D S 87'1725" W 23.98'
10C I Ic N 50°2608' E 16.15' 8A 9A S 55°25'41' W 26.57' 5D 6D S 74°2616" W 19.49'
i1C 12C N65°10'1TE 34.41' 9A 10A S80°04'08'YU 23.21' 6D 7D S45'00'42"W 24.69'
12 CIC N61°3Y34'W 46AIT 10A 11A N38°1509'W 17.54 iD BD S24°41'16'W 36.10
NOTE:
UPLAND PORTION OF PARCEL A
HAS BEEN CLEARED
IEX/ST/NG DRAINFIELD AREA
UPLANDS
��e' :f � �vi���.'.� � ...: •:. �i rig _
PROPOSED 15'
/DRIVEWAY
/
EASEMENT,_,_._.�'
I1D. a
PARCEL , � �'� � y a
WEAAND
1.73 ACRES (75,143 SF) `• y
0.92 ACRES UPLANDS - • . a
0.81 ACRES WETLANDS
a PROPOSED WETLAND FILL
0.024 AC. (1,045 SF)
a
WETLAND
a
a PROPOSED WETLAND FILLti
y a 0.007 AC. (311 SF) a
a a
a ,9
I
' UPLANDS
1 a
<7 AND •
y
Imo''. ,,, �.-•—' �'
it f i
1•� l y 1.06 ACRRES`(46,123 SF) ` a
a ------0.67 ACRES UPLANDS
�2OPOSED CULVERT 0.39 ACRES WETLANDSA
1124" HDPI ® 30'
a ly
ya y
a y
l
--t., , a fz y
I I •
I''; WETLAND a
UPLANDS! `
I-' PROPOSED / l
1 a �. 40' RESIDENCE /
l ii y i ri;' PP ct <
y,J i PP v j
yi t'i't' PROPOSED DRAINFIELD I
y <•: 5 36' LINES 3' ON CENTER20
I
e?• .rit �s.•.. ial
LEGEND:
BUXTON, NC
am
WETLAND FILL AREA 0.031 ACRES
C!, PROPOSED PROPOSED DRIVEWAY LOCATION
PROPOSED CONSERVATION EASMENT
AREA 13,600 SQUARE FEET.
-•-•-•-•-•-•-•-•- EXISTING 404 WETLAND LINE
ROADWAY RIGHT-OF-WAY
PROPERTY BOUNDARY
N/F
U.S GO RNMENT
DB A; Pg 261
WETLAND WIDTH VARIES 35'-44' SITE PLAN FOR NATIONWIDE #14
PROPOSED FINISH SGRADE
{'- :.._ ...F . }�; -..... JOHN 0' B R I E N
PARCELS A & B
BUXTON — DARE COUNTY — NORTH CAROLINA
I I I L I l I r'' 30' 0' 60' 120' 180'
ArZANT/C ENV/RONA1ENTAL CONSULTANTS, ZZC
WETLAND FILL CROSS SECTION GRAPHIC SCALE 1"= 60' P.O. 80X ,3266, K/TTY 11.4!!'x, N.C. 27949
(252)261-7707, a moi/ dougdoec®gmoi/.com
FILE: O'BREIN 2017 DATE 7/10/17 REVISED:
John O'Brien
448 Sooy Place Road
Vincentown, NJ 08088
I, authorize Doug Donnan of Atlantic Environmental Consultants, LLC (AEC)
to act on my behalf as my agent in the processing of applications and to
furnish, upon request, supplemental information in support of the permit
application.
DATE