Loading...
HomeMy WebLinkAbout20010550 Ver 1_14-107-SWM-REPORT-2017-06-01_20170814STORMWATER MANAGEMENT CALCULATIONS FOR: WAKE FOREST DEVELOPMENT WAKE FOREST, NC WAKE COUNTY, NC Project # 14-107 Prepared for: MOSELEY REA 'I'100 Kenilworth Ave, STE 210 Charlotte, NC 28204 Pre ared B : p Y - �*' u e� `•�� J 'w �� , ''r • „ ?t . � T, ';� �;y. .' 7� y, ; �„' t.l�. �'},.`r ' �y 'C. "'4. :�' � . , .p• . .' � � • ��.�t... .::M � " -� �.. ti'. `2��, i. •r . �i�. � "..y f '�,, ` H+ tc� ,r y ' �n ' . � ' a ��tii�5 �- � . � i:��, � y ;/ 4` , " , ei �,� ¢ �,) 4 �.: ;t `'�7�.r�, `1 . ■�m f^.'. -�`� t+y: i 'x•� � � . . _. �. � �.i �:' : T, � iJ �. .:..+ '� � � � � f ��y �' � �►w -7 ��y � � � � <;:'�b o'i � � �, � '�",�' +�' .i� °�.`'ts �� � ������ � � � a� ���� � � � ���� �� ��� �� � v ��� ��� ���; � �a � `, �. ,�, �� � � r� • � J6�1 N. TRADE STREET, SUITE 200 WINSTt�N-SALEM, NC 27101 www.stimmelpa.com 336.723.1067 LANDSCAPE ARCHITECTURE CIVIL ENGINEERING LAND PLANNING June 'I, 2017 TABLE OF CONTENTS STORMWATER MANAGEMENT NARRATIVE SOILS MAP COMPOSITE RUNOFF CURVE NUMBERS RAINFALL DATA PRE-DEVELOPED HYDROGRAPH POST DEVELOPED HYDROGRAPH POND REPORTS ROUTED HYDROGRAPHS SAND FILTER CHAMBER CALCULATIONS DRAINAGE AREA EXHIBIT SITE PLAN AND SWM DETAILS WAKE FOREST DEVELOPMENT WAKE FOREST, NC WAKE COUNTY, NC Project # 14-107 STORMWATER MANAGEMENT NARRATIVE INTRODUCTION This site is a lot which is being purchased from excess Right of Way from NCDOT located in Wake Forest, NC at the intersection of Retail Drive and NC Highway 98. The site is currently comprised of undeveloped land bound by public roads. The proposed lot is approximately 3.19 Acres in total size. The site currently has a high point eastern side which conveys stormwater in multiple directions by overland flow to existing underground conveyances maintained by NCDOT Right of Way, and ultimately to Richland Creek. The proposed site will convey on-site stormwater by overland flow and/or curb and gutter to the stormwater management system located at the West side of the property. The stormwater management system overflow will be conveyed to an underground conveyance system and ultimately discharge to the existing 24" Culvert corner flowing under Retail Drive to the West. The stormwater management system will receive approximately 5.18 Acres of drainage area during ultimate build out conditions. The drainage area consists of the new 3.19 acre site development as well as additional runoff from the existing public roads currently draining to the existing ditches located at the north side of N.C. Highway 9 and the east side of Retail Drive. Drainage from these ditches is gathered and conveyed by an underground conveyance system leading to the stormwater management system. Runoff from this site is not currently being managed for quality or quantity. The site is located in Richland Creek Water Supply Watershed (WS-IV) under the jurisdiction of the Town of Wake Forest. The increase of impervious cover must be managed for quality under The Town of Wake Forest Stormwater Management Program. The proposed stormwater management system consists of one device containing a sand filter and a detention chamber. The sand filter will provide quality treatment of runoff for the first one inch of rainfall and is designed to remove 85% of TSS. Additional storage needed to attenuate the Town of Wake Forest Required 2-year and 10-year stormwater requirements will also be provided within the detention chamber of the stormwater management system. METHODOLOGY Existing and proposed hydrologic computations were perFormed using the Soil Conservation Service's Technical Release No. 55 (TR-55)'. Time of concentration and runoff curve numbers (CN) were developed by the methodology in TR-55. The time of concentration for the pre-developed and proposed stormwater conveyance that directs the site's runoff to the sand filter is 6 minutes based on the small water shed area and TR-55 minimum time of concentration'. The USDA Soil Conservation Service's website (Soil Survey) 2 was used to determine the existing soil group classifications. Soils present on this site have a hydrologic soils group classification of `B' and `D". The entire site is comprised of the following soil type and a brief description: Soil Name and Map Svmbol Hvdrologic Soil Group Appling sandy loam — ApC2, (6 to 10 % slopes) "B" Appling sandy loam — ApD, (10 to 15 % slopes) Cecil sandy loam — CeC2, (6 to 10 % slopes) � fY� Wake-Wateree complex - WkE, (10 to 25 % slopes) "D" The existing site is comprised of undeveloped land mixed with some existing roadways. Open, Fair Conditions were used to classify pervious areas in determining the Composite Curve Numbers for both the Pre and Post Developed Site. Composite curve number calculations with references of the drainage areas are included in the appendices. Rainfall data used in the hydrologic analysis for the project was taken from Point Precipitation Frequency Estimates From NOAA ATLAS 14 4, provided by the NOAA website. Hydrographs follow the SCS Unit Hydrograph Method as outlined in National Engineering Handbook3, (NEH-4). Hydrographs were calculated based on a shape factor of 484, using the computer modeling system in the software Hydraflow Hydrographs produced by Autodesk. Pipe flow out of the stormwater management system was calculated under both inlet and outlet control, and the lesser of the two outflows taken as the control. A weir coefficient of 3.0 was used for the open throat outlet structure in the Bioretention-cell. Storm hydrograph routing through the stormwater management system was performed using the Storage Indication Method as outlined in NEH-4. A brief summary of the routing results are included at the end of this narrative. Detailed routing calculations are included in the appendices. DESIGN PARAMETERS This project is located within the Town of Wake Forest jurisdiction which is subject to Phase II rules. The North Carolina Division of Water Quality recognizes the Town of Wake ForesYs Stormwater ordinance as meeting the requirements of Phase II rules. The Town's Phase II requirements are as follows: The stormwater management system shall be designed to reduce the post-development runoff rate to the predeveloped runoff rate for the 1-year, 2-year, and 10-year, 24hr. storm events 5. A minimum of 85% Total Suspended Solids (TSS) must be removed from the first one inch of runoff. General Engineering Criteria shall be in accordance with 15A NCAC 2H .1008(c) 5. The stormwater management system is designed to meet the Quantity and Quality Specifications. The NCDENR BMP manual was used for overall design standards of Stormwater BMP's. Refer to appendices for Sand Filter Calculations for design in accordance to the NCDENR BMP manual6. SYSTEM CONFIGURATION The stormwater management system proposed for this site is comprised of one device containing a sand filter and a detention Chamber to address both water quality and water quantity requirements. The Sand Filter chamber of the STWM Device provides a total of 10,710 cubic feet of storage volume to meet the adjusted water quality volume requirement per the manual. Stormwater enters the Sand Filter chamber by way of underground storm drainage pipes as wells as by overland flow for portions of the open areas within the drainage area. The sand filter chamber contains a sand filter, a sedimentation chamber, and provides additional storage to accommodate the adjusted water quality volume. The sand filter is designed to infiltrate 1.75 inches/hour (3.5'/day) to address water quality requirements. The Sand Filter underdrains will be 4 inch smooth wall perforated PVC pipe and flow to the Detention Chamber of the STWM Device. The detention chamber of the STWM device is designed to hold the runoff from the 2 year and 10 year storm events and release them at a rate less than that of the pre-developed runoff. PRE / POST COMPARISON The following chart shows the SCS 24 Hr Storm flows for the pre, post, and routed conditions of the drainage area contributing to the STWM device. Please refer to the appendices for pond data and routing information. There is a decrease in flow in the post development conditions from the pre development conditions for the 1-year, 2-year, and 10-year, 24 Hour SCS Storm and as a result complies with the Town of Wake Forest Phase II requirements. STORM PRE- POST- ROUTED DIFFERENCE ELEVATION DEVELOPED DEVELOPED FLOW FLOW FLOW ear cfs cfs cfs cfs 1 10.49 17.31 9.23 -1.26 272.56 2 14.74 22.11 12.55 -2.19 272.60 10 26.71 34.76 25.47 -1.24 272.73 REFERENCES (1) Technical Re/ease No. 55, USDA Soil Conservation Service, December 1993 (2) http://websoilsurvev.nres.usda.qov/app/, 2016 (3) National Engineering Handbook Section 4-Hydrology, USDA Soil Conservation Service, 1972 (4) http://hdsc.nws.noaa.pov/hdsc/pfds/,2016 (5) The Town of Wake ForesYs Phase ll Stormwater Ordinance, Town of Wake Forest, July 16, 2013 (6) Stormwater Best Management Practices Manual, NCDENR, July 2007 SOILS MAP M,�Z�ZE o8L � C O N U L � O Z � C 3 O U N N Q 7 O i.� 'o � U .� O O � � 2 M �ST �£E o8L Z Z a � M 005£86£ OOb£86£ 00££I86£ OOZ£86£ OOT£86£ 000£86£ 006Z86£ 008Z86£ OOLZ86£ 009Z86£ OOSZ86£ M ��' _ _-�+ ,� � - �. 1{ � � - � M„Z,Z£ o8L O O = w � �'-��I . A r "� - # � : N � o - ' Y k;ti •� ,y, �� r' . -. �.�" _ � o' � � _ _ - "�-`� +.� � - (h (D � "M�s - �^ o d ^N— Y�� -�:r'�. t . ' ��� � > . _ 'F . . �^ . _ O �,� � �� c _ � _ � t o - -" - �' . , � • N _ � -: � t� � ��� � O � � ..�,, � ' � � � N .� ." , � � �. � � . - �_ � � .���°1 �e' � R ... � ^ 00 - �� f. w��� I� .� � - , � y., N � � � �x_- `�'# ' r , � o ^ � '^ ` �M1 "k,` , �� _ � t���R. � ���,�i' ��s� � o �_ � � 'w -.:- _ • f� F �.. � -.1 I O_ ��. .�+q-y�p.� � �_ ' � � iR � fi r�; . � , � .. o ^ � _�T►Y� �.��FF ���:-���@`�25d, ��� � -1 -`� =+� �F'_ rC � �'� ,�� .r � -'`- � . I�- , . , u .'�t` o yyy ilF " O � � �:..�- y� . � :� ° �� �,� ,:, K .. � I� O ` � � �" . � �� v, . � �� . � .f� Y? �� T�' � � k q ^ e _ .qt 1 "4 �..� § �. Y J � i �'s� -._1 O ���r � ��� k fi `P� � . a �.` ��� � 4,,'�q f ,q - ^ �� � � p, o ��;. � 4.;tF . r, '� ' '�¢ �.. � � —. y+�_ � � t i � � � ^ r , _ T � !L . '� � O � . .... _ _ . « . , .. . ��� __ A� � � sit;;-_�_ � _ W ~f N .� i� � � � :+�. Y . . . - f• _- -�E. `> �} . �' � .,: h . � � -T' i -` �s_ � y�..11 }�/Eti' O 'yr.�y_y '�� - J • � �� 1� y � ���3_ '-�� N— _ . ._s.� _ .. n .�- � . � � � - _ � �-�—.y� � o O � �' 4 .• . . _ ` . � .�� :-`�'__. - _ � .-. . � "t_a �� � ^ L 1�� r , � � _: = : y �, ,;; �t � � ' ! �°a�. `:}7� ¢ e- -� - �� o (n I _ ,� t 2 � � �- o h + � * R �. 4 . : �,.p S'F?�. . � _ _ � � : � N � O O ,+��T' - -�' I M1���� , : �'rt .? . I� 3 � o—� � � �I� x s�Y �. �M1 y� '�g �'!�' � '(0 n - _ - f' ,�,. � ��i -- _ c er.-� �� �';� -- o � a) '�, .�at+»�+�- � � � � . �` c -ti � — �- � �` # � aN r � ^ � N O L' +� #,�'� _ e� � �4M' u . t �, � U N_ j�+' �� �`�' �1.�£i--.,C ��� �: � ? •.Y'F �h p �O � � � � �,r- +�`�. ��� . �• •. � l' �, '. � � � ay,�i � � O F '� z , � � ,.; �` � _ _ 3 - � ,�� , � � � � o a, �m '' * �-F. ' � _ � � { _.-�"n _ '�� � o Z � -� o �_ r� � �.,'� ' r� �„� _ •�_�..�� � _ .� _' ::_ . �;`: N � A .� -�; � + =.s�.. ..� ��"� .f" r � .�#e:4 � ' � � .�� ... .'r . 14���a��.., � �". .. � � :� - _�.¢ _ L i� �� t�J4 0 g.. �e . , �,ti .f. 3 '�t f •�' t � � �T �� � � # .r � � �' +�^� � �, � �, �r- � . .�- � �� �= � n �` ��-: E ,. � ^� �',� • ,4: r+� '� a`�:� st' ; . '..� o� o . ' �_ `��-, � .� s �• ,,,�t. ��f �, �, . p a;� � . � ,,� .,u, t,.r*�C"�� ' o � `�P' ^ . x� . � �� _ t ����}�3 '•�h � �' �`� J . & � } �`4 �"' � � L i I fi - . .�" �� �� . _ � ^ o � ' r�r F �- �- t � ' � ,� . � r 'y� J � �� r �- � ��� S - n in op � C7 .,�.� r fi �"j O d �. �_ .., _i��f � i'-. ��:� � .� a 4"-,� 9,� ,�7� '� S � - �� � � � }� ; r � �. � F - ut N—. ���'„��+� . '�; "�� �a j .`'F._ ��''. tl.=.�,,� ��� ���'.i 5 �` i'+., g � � ^ F� F � A3a • �;� .�. t : - - k '� � � -s # ��+'" � � ���-_ _� � _ � � Q N .. � �1i,� . -� y a �. h _. y� - �� '` �.-.�' � tS �•a .P =� " �. �.i'�l� _ i 1� j� �:.��n'y� � 0 '�T - i � .i. � • �, �4�k'. K�%�� � OJ �—y�� � �° . � � '� � '�r.. t0 E t y�� ��,y �^ � - �,� (� �`� o a 8 N � ^ ,�,���°�'"� �- U ��r ���F. ...*r�� �' 4 �. �� ,�t� �; �� �; - � ~ � �1_'. '4 � N O OO i U `�- y�* J�•... -.� � � � � '`.-�1 � ,�/`" �,� ,�+s� e.:- .�t�' ��-� ' � � o � � F_ �R'- ' �'� 4� _ . '4 � ��,� � C N o� �s'Af +� d' _ _ i,� �:, . : . r �s ' �`z`-" #�" � g 0' � o y .ee - : . � � ." ' • o ,� v V r� �� �� ,� ` ` �� �" - '� '�'�� '`'�• °, e� � -� " °�' o N `�` �'�� * r� r C��k� � �T � k � ��� °r4 . � � � ri � � y � � � cs�. �i ?A ^�1� �r _ � � _,a ��.���� � g � O . `'%*�# �'. !c !`,+' �. , �4° ;� . 4 �,-' �i ='�� � M � � �, � � � . � �� �"%,. � ��� . ' �. ,�,,,��-- � "-.w �'� v;q � _ � 1}F� oN i Q_ ,..ac� ,k,,� F� �;: � � �2} �, t � -� �f �� �., �..,'� �. �� o lh a y O f � ��'� i,� r �;'�P � };ts. c..- ' ,� � � - y � � � �=.pSR . - .. � � m � � '�-`�� � ; .• �j_ �� �.�� ^ M � o o � 0 1L�'�r ,*� � �: �y . � / � �, � 'r 'M' "�+l�w� �'� � � C o—`� '��+y. �'„�� f a :. > m. � .� i''� - '�`' � �".. -� { 1 �_ o � �, ,�„ <O O . +7F Q+c - • .^ � J. �. �E � �r '�'� �� �� �-"„. c� � — o z Z U I� •' ��" r- t ,•'�' �. �r� ,� � �+5� n d�..�-._� ... .:��-�.e�`��....�_u'.�.-�,a�a. �' �..����'t.s� S�- . . ..Lr'ti� . � �,' ..� M,�TT�££o8L Q � � I � � � � � � � � � ��� 005£86£ OOb£86£ 00££86£ OOZ£86£ OOT£86£ 000£86£ 006Z86£ OOSZ86£ OOLZ86£ 009Z86£ OOSZ86£ ��� z z � � � � � O m U L � O Z � c � 0 U � Y >N i Q � � 'o � U .� O 0 � � 2 Z 0 � � LJ.. Z a � Z w t� w J a Q � � o O � � � (d N U �p � � � � � � � V m � � L N � � � � ��/7 7 � N � � � � � � � � 7 O 0 ` � � � � � V � N � C W +s-' N� u7 (� - � o"� °- � � U o � N � � N� fn 'O N Z� N Z Ci O � U.`� W ��� o o- p � c"�i L � O �� Q L � (n z d � �� O � � tn � a� (D � 3 V T� �, ��p � C V � � c �� a� � c � m 3 � � a� Q � � � -° a� �' � o � � � � � � � �'o � ° � U o U (` _ >� UJ � � Q O 'O � Y ` > — � O � � � �� � �Q�o � �° N �� N Z � � >� �' N � i/� � r/7 �p ..L. � � > V � � 'O � � � (E O C (D � � � -C (6 (D 0 [� � Q Q �' � � �%% � 3 � � C 7 � �' � � � � � � Q O -O .� N � � O C �� U�� � i � T N(/7 ��_6 f/7 U C� �- N (n N N � p � O (6 O U7 � U � � — � a E cn�U � a�Q c`°i �� cncn � M m i C � � � ! � N -6 � 3 � o � � � � G � � O � f N � � � 1 = •1 � 1 t � O � O � � N : � � � � � � ..-r � L � N 1 � L p � � L 3` m � 1 � � � a � i � O- � �j > { O @ Q � i � � T @ � r �� �� ' � � � � : � m a � m i � � Q � � ! 3 a� w w ; rn -� � c .� � � O N O . N 1 � O 'O %'O � � O (6 � � d � ' Q � � «� � ' � L �6 � 7 � � � � � i d � � � � � N � 1 O ��N H�U .� O m m T f6 C N L N �- o V L � � °' o � � � .°o m � � m � o � � m o 2�' � d � c6 tn � �' p cp N � — N U U U � Z 3 i� g� � � � � � Q � �m c 0000 � �-� � �,� � � � � � � m O Q N N N = C � w Q � (6 N � d Q `m _ O N Q � � � � m m m m 'm m 0 0 C C y O O C O 'o 'o N � d N � � �p N �p C C p�, 0 ❑ � � ;J � � 0 p p�, 0 � c, Q '¢ m m c� c� � z c, ¢ a m 'm c.> U o z c, a a m m c c c � o❑❑❑❑❑❑❑❑ o � � � � � � �' z ao o ■ ■ •p y N y N �v �w 0 0 N N � � N � M a T N � � � � 'o � � � � � �� = N O � (� Q � U (� 0 .� Z m � y � G1 3 N O � y O � � l`E y 7 y C i0 O Z U O i� � Hydrologic Soil Group—Wake County, North Carolina Hydrologic Soil Group Hydrologic Soil Group— Summary by Map Unit — Wake County, North Carolina (NC183) Map unit symbol Map unit name Rating Acres in AOI Percent of AOI ApC2 Appling sandy loam, 6 to B 1.6 28.4% 10 percent slopes, moderately eroded ApD Appling sandy loam, 10 B 3.4 60.3% to 15 percent slopes CeC2 Cecil sandy loam, 6 to 10 B 0.2 2.7% percent slopes, moderately eroded WkE Wake-Wateree complex, D 0.5 8.6% 10 to 25 percent slopes, very rocky Totals for Area of Interest 5.6 100.0% U��a Natural Resources Web Soil Survey 3/28/2016 � Conservation Service National Cooperative Soil Survey Page 3 of 4 Hydrologic Soil Group—Wake County, North Carolina Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long-duration storms. The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink-swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. Rating Options Aggregation Method: Dominant Condition Component Percent Cutoff.• None Specified Tie-break Rule: Higher U��a Natural Resources Web Soil Survey 3/28/2016 � Conservation Service National Cooperative Soil Survey Page 4 of 4 COMPOSITE RUNOFF CURVE NUMBERS Project : 981 Crossing - Wake Forest Development Sheet : 1 Project No.: 14-107 Date : 5/17/2017 Designed by: KAB Revised: 5/17/2017 Checked by: KAB Pre and Post Developed drainage area SCS RUNOFF CURVE NUMBERS PRE-DEVELOPED CONDITIONS BASIN LAND USE SOIL HYDROL. AREA AREA CURVE NO CN x NAME GROUP (AC.) ( % ) (CN) AREA Open, Fair Condition ApD, ApC2, CeC2 B 3.28 63.30% 69 226 Impervious ApD, ApC2, CeC2 B 1.06 20.39% 98 103 Open, Fair Condition WkE D 0.27 5.14% 84 22 Impervious WkE D 0.58 11.17% 98 57 TOTALS 5.18 100.0% 408 WEIGHTED CN (PRE-DEVELOPED) = 79 POST-DEVELOPED CONDITIONS BASIN LAND USE SOIL HYDROL. AREA AREA CURVE NO CN x NAME GROUP (AC.) ( % ) (CN) AREA Open, Fair Condition ApD, ApC2, CeC2 B 1.29 24.87% 69 89 Impervious ApD, ApC2, CeC2 B 3.05 58.86% 98 299 Open, Fair Condition WkE D 0.27 5.14% 84 22 Impervious WkE D 0.58 11.13% 98 56 TOTALS 5.18 100.0% 466 WEIGHTED CN (POST-DEVELOPED) = 90 RAINFALL DATA Precipitation Frequency Data Server Page 1 of 4 ._ NOAA Atlas 14, Volume 2, Version 3 �,..�,� �� �. Location name: Wake Forest, North Carolina, US* }� � Latitude: 35.9675°, Longitude: -78.5437° €'� � Elevation: 278 ft* �' � ,.�a * source: Google Maps ^w.,,; „.9'^ POINT PRECIPITATION FREQUENGY ESTIMATES G.M. Bonnin, D. Martin, B. Lin, T. Parzybok, M.Yekta, and D. Riley NOAA, National Weather Service, Silver Spring, Maryland PF tabular � PF qraphical � Maps & aerials PF tabular PDS-based point precipitation frequency estimates with 90% confidence intervals (in inches)' I Average recurrence interval (years) )uration 0000000000 1 2 5 10 25 50 100 200 500 1000 5-min 0.402 0.468 0.535 0.599 0.663 0.713 0.757 0.796 0.835 0.875 (0369-0.440) (0.430-0.51 1) (0.491-0.584) (0.548-0.653) (0.604-0.722) (0.646-0.776) (0.683-0.824) (0.713-0.868) (0.745-0.915) (0.771-0.957) 10-min 0.643 0.749 0.857 0.958 1.06 1.14 1.20 1.26 1.33 1.38 (0.590-0.702) (0.687-0.818) (0.786-0.935) (0.876-1.04) (0.963-1.15) (1.03-1.24) (1.09-131) (1.13-138) (1.18-1.45) (1.22-1.51) 75-min O.S03 0.942 1.08 1.21 1.34 1.44 1.52 1.59 1.67 1.73 (0737-0.878) (0.864-1.03) (0.994-1.18) (1.11-1.32) (L22-1.46) (1.30-1.57) (1.37-1.66) (1.43-1J4) (1.48-1.82) (1.53-1.89) 30-min �•70 130 1.54 1.76 1.98 2.17 2.33 2.48 2.66 2.80 (1.01-1.20) (1.79-1.42) (1.41-1.68) (1.61-1.97) (7.81-2.16) (1.96-2.36) (2.10-2.54) (2.22-2J0) (236-2.90) (2.47-3.06) 60-min �•37 1.63 1.95 219 2.64 2.93 3.21 3.47 3.81 4.09 (1.26-1.50) (1.50-7J8) (1.81-2.75) (2.09-2.49) (2.47-2.88) (2.66-3.20) (2.89-3.49) (3.71-3J9) (339-4J6) (3.67-4.47) 2-hr �•61 1.91 234 2.74 3.21 3.61 3.99 4.39 4.89 533 (1.46-1.77) (1J5-2.10) (2.73-2.57) (2.48-3.00) (2.89-3.50) (3.24-3.94) (3.57-437) (3.89-4J9) (430-535) (4.64-5.84) 3-hr �•�0 2.03 2.49 2.93 3.47 3.94 4.41 4.89 5.53 6.10 (1.55-1.88) (1.86-2.24) (2.27-2J5) (2.66-3.22) (3.13-3.81) (3.53-433) (3.92-4.83) (432-536) (4.83-6.06) (5.27-6J0) 6-hr Z•04 2.44 3.00 3.53 4.20 4.79 5.38 5.99 6.82 7.57 (1.57-2.26) (2.23-2.69) (273-3.29) (3.21-3.87) (3.80-4.59) (430-5.23) (4J9-5.87) (5.28-6.53) (5.94-7.43) (6.50-8.26) 12-hr Z'41 2.88 3.55 4.21 5.04 5.79 6.55 7.35 8.46 9.47 (2.21-2.65) (2.65-3.16) (3.26-3.89) (3.85-4.67) (4.58-5.50) (5.21-6.29) (5.83-7.11) (6.48-7.97) (734-9.77) (8.09-103) 24-hr Z•$6 3.45 432 5.01 5.93 6.67 7.42 8.19 9.24 10.1 (2.67-3.07) (3.23-3.71) (4.04-4.64) (4.67-537) (5.52-636) (6.15-7.15) (6.86-7.96) (7.54-8.79) (8.48-9.92) (9.20-10.8) 2-ddy 332 3.99 4.96 5.72 6.74 7.55 8.36 9.20 103 11.2 (3.10-3.56) (3.74-4.29) (4.63-533) (533-6.14) (6.26-7.24) (7.00-8.10) (7.73-8.98) (8.48-9.89) (9.48-11.1) (70.3-12.1) 3-ddy 3.52 4.22 5.22 6.01 7.07 7.92 8.77 9.65 10.8 11.8 (329-3J6) (3.96-4.52) (4.89-5.59) (5.61-6.43) (6.58-7.57) (7.35-8.47) (8.12-9.40) (8.90-10.3) (9.95-11.6) (10.8-12.7) 4-day 3.71 4.45 5.48 630 7.41 8.29 9.18 10.1 11.3 123 (3.48-3.97) (4.17-475) (5.74-5.85) (5.89-6.72) (6.90-7.90) (770-8.85) (8.50-9.81) (933-10.8) (t0A-12.2) (71.3-13.2) 7-day 430 5.13 6.24 7.13 833 9.28 103 113 12.6 13.7 (4.04-4.59) (4.52-5.47) (5.86-6.65) (6.67-7.59) (7.77-8.SS) (8.64-9.90) (9.52-10.9) (10.4-72.0) (11.6-13.5) (72.5-14.7) 10-day 4•89 5.82 6.99 7.91 9.15 10.1 11.1 12.1 13.4 14.5 (4.60-5.21) (5.47-6.19) (6.56-7.44) (7.42-5.42) (8.56-974) (9.45-10.8) (103-11.9) (11.2-12.9) (12.4-74.4) (73.4-15.5) 20-day 6.56 7.74 9.14 103 11.8 12.9 14.1 15.3 17.0 18.2 (6.18-6.97) (7.29-8.23) (8.61-9J7) (9.64-70.9) (17.0-12.5) (12.1-13.8) (13.2-75.1) (143-16.4) (75J-18.2) (76.8-19.6) 30-ddy $'�4 9.57 11.1 12.3 13.9 15.2 16.4 17.6 19.2 20.4 (7.69-8.64) (9.04-70.2) (10.5-71.5) (11.6-13.7) (13.1-14.8) (14.2-16.1) (153-77.4) (16.4-78.7) (779-20.5) (759-27.8) 45-day �0.4 12.1 13.9 15.2 17.0 18.3 19.7 20.9 22.6 23.9 (9.86-10.9) (11.5-72.8) (13.2-14.6) (14.5-76.7) (16.7-17.9) (173-193) (18.5-20.7) (19.7-22.1) (21.2-24.0) (22.3-253) 60-day 12.4 14.5 16.4 17.9 19.7 21.1 22.5 23.8 25.5 26.8 (11.9-13.1) (13.8-153) (15.6-772) (17.0-78.8) (187-20.7) (20.0-222) (21.3-23.7) (22.5-25.1) (24.0-26.9) (252-283) Precipitation frequency (PF) estimates in this table are based on frequency analysis of partial duration series (PDS). lumbers in parenthesis are PF estimates at lower and upper bounds of the 90%confidence interval. The probability that precipitation frequency estimates �or a given duration and average recurrence interval) will be greater than the upper bound (or less than the lower bound) is S%. Estimates at upper bounds re not checked against probable maximum precipitation (PMP) estimates and may be higher than currently valid PMP values. lease refer to NOAA Atlas 74 document for more information. Back to Top PF graphical http://hdsc.nws.noaa.gov/hdsc/pfds/pfds_printpage.html?lat=35.9675&lon=-78.543... 3/31 /2016 Precipitation Frequency Data Server 25 - ' -- =- - ' -- '-- ' - �- --�'- - � --- -- -- - - -- . . . . . . , . , . . . c � 24 - - ---- --- - -- - --- -- ---- --- -- -- -- -- -- --- � . . `� o�� . ... ...- •-- -.. .- •-. -.. -- � Y � �a 1{) ... . . ... ... ... . ... , ... - - ..+jV. v v a , . , . . ,r _ , , , 5 , ���: . , ...............,... .- .. - µ�� � -��= — � - � � c c e � � � � � �. a. � a, �. a. T�. �, t s t t r ra ra rg rt rp +a rrs ro ra � E E � E ,;� r'� u?+ �., v � a a �s a �-a -c � � 0 � p p .-I I'V N l�"I '7 M1 6 (7 4 u1 O '-f r-I fft la .-� N f/'1 � lp [?u ra6i�n zs e s 24 a v v � 15 JY � 1.+ .� 'V lfl cv �. a 5 Page 2 of 4 i,.erage recurrence mEenal i:yearsj �� 2 � � — 1Q — 25 — 5D — 1D0 — �90 5D❑ — 1600 C7urati,��i 5-m�n — 2-day — 14-min — 3-day 15-mm — 4�iay � 30-m�n — 7-day — 6i1-min — 1cY-6ay - z�r — z�-aay — 3-hr — 3v-�ay — '6�'lI — dJ-f;�z]'y — 4 �-hf — �)l)-C18Y ra-�3r � F-- - c _ �_ � i i i i � a z s iQ zs so ior� zoa soo boQa Backto To Average recurrenee interval years Maps & aerials NOAA Atlas 14, Valume 2. Version 3 Created (GMTI: Thv Mar 31 13:52:49 201fi Small scale terrain ��'r Hichmannd �` " �'� -.�� � `f ' � �� � 'tK �,."1 �., sr�l � "` '%��oaPce . . . . xh'�illi�m5h��r� �, � �-Black.sburg .. �Nrw�c�r4 Neuam �f ;,l�''� Nod�f[alt �Virr�ini� €3e2 �' - - v j � -.- ,r-�t�`r . .:.- _ —�fy._ . � . . _ . . . e� ior�^�s['" ` . � goo�,e Greens6vr� ,.., � ,_ �„ Wirtstan-Sa1em� a � Dueham ! �i i r.e4•i �i rr � o � f�ock �MounE � h� [1 F',' T �i Ralrijh Hickory-• i� Greenville �� �,t',f�C�L�Pd � � Charlatte +p � New Rern �ayetzeville @ , T�' 8 Cpprtanburg oRock Mill Jaekson�itlle G ivi0 f P�}i4 elS'� 'L'liy _ '��, — � V �C � iiaz "o,':�,n�,d Yaungsville . ' 1&73 1137 i ars ^�T Nill Ridge Farms `i� = Nev�,� Lit�ht ' �---� ���, � � _ � � �. http://hdsc.nws.noaa.gov/hdsc/pfds/pfds_printpage.html?lat=35.9675&lon=-78.543... 3/31 /2016 Precipitation Frequency Data Server .1°" , — 1�37 � I . � �_�: � :� $ ' • 9� � 1=}r� . }: r� � � �, � 11; , ' , , ' ' 1 Y.+ll � Y � ��. 1'$71 SR .' I I j ' #. ``:� :�rnny I lill ;. w�ke rnee.;t C ;� :�a, ` �, r.�'r ;� � l��i � , � . - ' _ �Qf�°SiL�IIIP. 1�. � �_�ti� c �, �4 rtK17 5 `�� . ���.u;a� iid -� � � 4.n�4`� ^� � Falls -' `" ,.a :� ,, F-`�9 � Large scale map ��,�. �i3}r - - �t: rga� ` i�ri � i � y Hill � Wake For��t � [ �� I - 4 �'' I^ r nres[ville � ' ,� -�_ �v02 bt�A,- J ... � ,;:� . � ty?.u:=i, iid � @ Falls #�`��`l m r m :�, � i �O �IQ 2km MapcF���e���etcgd� Large scale aerial Back to Top US Department of Commerce National Oceanic and Atmospheric Administration National Weather Service National WaterCenter 1325 East West Highway Silver Spring, MD 20910 Questions?: HDSC.Questions@noaa.qov Page 3 of 4 I �_rl � r . ���� d n c�i 19A5 4C51 2057 http://hdsc.nws.noaa.gov/hdsc/pfds/pfds_printpage.html?lat=35.9675&lon=-78.543... 3/31 /2016 Precipitation Frequency Data Server Disclaimer Page 4 of 4 http://hdsc.nws.noaa.gov/hdsc/pfds/pfds_printpage.html?lat=35.9675&lon=-78.543... 3/31 /2016 PRE-DEVELOPED HYDROGRAPH Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D0 2016 by Autodesk, Inc. v10.5 Hyd. No. 1 Pre-Development Hydrograph type = SCS Runoff Peak discharge Storm frequency = 1 yrs Time to peak Time interval = 1 min Hyd. volume Drainage area = 5.180 ac Curve number Basin Slope = 0.0 % Hydraulic length Tc method = User Time of conc. (Tc) Total precip. = 2.86 in Distribution Storm duration = 24 hrs Shape factor Q (cfs) 12.00 10.00 : �� . �� 4.00 2.00 Pre-Development Hyd. No. 1-- 1 Year Thursday, 06 / 1 / 2017 = 10.49 cfs = 718 min = 21,081 cuft = 79 = 0 ft = 6.00 min = Type II = 484 � � � �_. � � �� Q (cfs) 12.00 10.00 : �� . �� 4.00 2.00 r.na 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D0 2016 by Autodesk, Inc. v10.5 Hyd. No. 1 Pre-Development Hydrograph type = SCS Runoff Peak discharge Storm frequency = 2 yrs Time to peak Time interval = 1 min Hyd. volume Drainage area = 5.180 ac Curve number Basin Slope = 0.0 % Hydraulic length Tc method = User Time of conc. (Tc) Total precip. = 3.45 in Distribution Storm duration = 24 hrs Shape factor Q (cfs) 15.00 12.00 • �� . �� 3.00 Pre-Development Hyd. No. 1-- 2 Year Thursday, 06 / 1 / 2017 = 14.74 cfs = 718 min = 29,615 cuft = 79 = 0 ft = 6.00 min = Type II = 484 1 11 ��� � � �� Q (cfs) 15.00 12.00 • �� . �� 3.00 �iTiTi1 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D0 2016 by Autodesk, Inc. v10.5 Hyd. No. 1 Pre-Development Hydrograph type = SCS Runoff Peak discharge Storm frequency = 10 yrs Time to peak Time interval = 1 min Hyd. volume Drainage area = 5.180 ac Curve number Basin Slope = 0.0 % Hydraulic length Tc method = User Time of conc. (Tc) Total precip. = 5.01 in Distribution Storm duration = 24 hrs Shape factor Q (cfs) 28.00 24.00 20.00 16.00 12.00 : �� 4.00 Pre-Development Hyd. No. 1-- 10 Year Thursday, 06 / 1 / 2017 = 26.71 cfs = 718 min = 54,494 cuft = 79 = 0 ft = 6.00 min = Type II = 484 Q (cfs) 28.00 24.00 20.00 16.00 12.00 : �� 4.00 0.00 0.00 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 Hyd No. 1 Time (min) POST-DEVELOPED HYDROGRAPH Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D0 2016 by Autodesk, Inc. v10.5 Hyd. No. 2 Post-Development Hydrograph type = SCS Runoff Peak discharge Storm frequency = 1 yrs Time to peak Time interval = 1 min Hyd. volume Drainage area = 5.180 ac Curve number Basin Slope = 0.0 % Hydraulic length Tc method = User Time of conc. (Tc) Total precip. = 2.86 in Distribution Storm duration = 24 hrs Shape factor Q (cfs) 18.00 15.00 12.00 • �� . �� 3.00 .rn.� Post-Development Hyd. No. 2-- 1 Year Thursday, 06 / 1 / 2017 = 17.31 cfs = 717 min = 35,989 cuft = 90 = 0 ft = 6.00 min = Type II = 484 Q (cfs) 18.00 15.00 12.00 • �� . �� 3.00 r.na 0 120 240 360 480 600 720 840 960 1080 1200 1320 Hyd No. 2 Time (min) Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D0 2016 by Autodesk, Inc. v10.5 Hyd. No. 2 Post-Development Hydrograph type = SCS Runoff Peak discharge Storm frequency = 2 yrs Time to peak Time interval = 1 min Hyd. volume Drainage area = 5.180 ac Curve number Basin Slope = 0.0 % Hydraulic length Tc method = User Time of conc. (Tc) Total precip. = 3.45 in Distribution Storm duration = 24 hrs Shape factor Q (cfs) 24.00 20.00 16.00 12.00 : �� 4.00 .rn.� Post-Development Hyd. No. 2-- 2 Year Thursday, 06 / 1 / 2017 = 22.11 cfs = 717 min = 46,562 cuft = 90 = 0 ft = 6.00 min = Type II = 484 Q (cfs) 24.00 20.00 16.00 12.00 : �� 4.00 r.na 0 120 240 360 480 600 720 840 960 1080 1200 1320 Hyd No. 2 Time (min) Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D0 2016 by Autodesk, Inc. v10.` Hyd. No. 2 Post-Development Hydrograph type = SCS Runoff Storm frequency = 10 yrs Time interval = 1 min Drainage area = 5.180 ac Basin Slope = 0.0 % Tc method = User Total precip. = 5.01 in Storm duration = 24 hrs Q (cfs) 35.00 30.00 25.00 �� �� 15.00 10.00 5.00 .rn.� Thursday, 06 / 1 / 2017 Peak discharge = 34.76 cfs Time to peak = 717 min Hyd. volume = 75,353 cuft Curve number = 90 Hydraulic length = 0 ft Time of conc. (Tc) = 6.00 min Distribution = Type II Shape factor = 484 Post-Development Hyd. No. 2-- 10 Year Q (cfs) 35.00 30.00 25.00 20.00 15.00 10.00 5.00 r.na 0 120 240 360 480 600 720 840 960 1080 1200 Hyd No. 2 Time (min) POND REPORTS Pond Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D0 2016 by Autodesk, Inc. v10.5 Thursday, 06 / 1/ 2017 Pond No. 2 - Sandfilter Pond Data Contours -User-defined contour areas. Conic method used for volume calculation. Begining Elevation = 266.25 ft Stage / Storage Table Stage (ft) Elevation (ft) Contour area (sqft) Incr. Storage (cuft) Total storage (cuft) 0.00 266.25 1, 785 0 0 0.50 266.75 1, 785 892 892 1.00 267.25 1, 785 892 1, 785 1.50 267.75 1,785 892 2,677 2.00 268.25 1, 785 892 3, 570 2.50 268.75 1, 785 892 4,462 3.00 269.25 1,785 892 5,354 3.50 269.75 1,785 892 6,247 4.00 270.25 1, 785 892 7,139 4.50 270.75 1,785 892 8,032 5.00 271.25 1,785 892 8,924 5.50 271.75 1,785 892 9,817 6.00 272.25 1,785 892 10,709 6.50 272.75 1,785 892 11,601 7.00 273.25 1,785 892 12,494 7.50 273.75 1,785 892 13,386 8.00 274.25 1,785 892 14,279 Culvert / Orifice Structures Weir Structures [A] [B] [C] [PrfRsr] [A] [B] [C] [D] Rise (in) Inactive 0.00 0.00 0.00 Crest Len (ft) = 35.00 0.00 0.00 0.00 Span (in) = 0.00 0.00 0.00 0.00 Crest EI. (ft) = 272.25 0.00 0.00 0.00 No. Barrels = 1 0 0 0 Weir Coeff. = 3.00 3.33 3.33 3.33 Invert EI. (ft) = 0.00 0.00 0.00 0.00 Weir Type = Broad --- --- --- Length (ft) = 0.00 0.00 0.00 0.00 Multi-Stage = No No No No Slope (%) = 0.00 0.00 0.00 n/a N-Value = .013 .013 .013 n/a Orifice Coeff. = 0.60 0.60 0.60 0.60 Exfil.(in/hr) = 0.880 (by Contour) Multi-Stage = n/a No No No TW Elev. (ft) = 0.00 Note: Culvert/Orifice outflows are analyzed under inlet (ic) and outlet (oc) control. Weir risers checked for orifice conditions (ic) and submergence (s). Stage (ft) 8.00 6.00 4.00 2.00 0.00 0.0 30.0 Total Q Stage / Discharge 60.0 90.0 120.0 150.0 180.0 210.0 240.0 270.0 Elev (ft) 274.25 272.25 270.25 268.25 266.25 300.0 Discharge (cfs) Pond Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D0 2016 by Autodesk, Inc. v10.5 Pond No. 1 - Vault Pond Data Contours -User-defined contour areas. Conic method used for volume calculation. Begining Elevation = 264.00 ft Stage / Storage Table Stage (ft) Elevation (ft) Contour area (sqft) Incr. Storage (cuft) Total storage (cuft) 0.00 264.00 1, 335 0 0 0.50 264.50 1,335 667 667 1.00 265.00 1, 335 667 1, 335 1.50 265.50 1,335 667 2,002 2.00 266.00 1,335 667 2,670 2.50 266.50 1, 335 667 3, 337 3.00 267.00 1,335 667 4,005 3.50 267.50 1,335 667 4,672 4.00 268.00 1, 335 667 5, 339 4.50 268.50 1,335 667 6,007 5.00 269.00 1,335 667 6,674 5.50 269.50 1,335 667 7,342 6.00 270.00 1,335 667 8,009 6.50 270.50 1,335 667 8,677 7.00 271.00 1,335 667 9,344 7.50 271.50 1,335 667 10,011 8.00 272.00 1,335 667 10,679 8.50 272.50 1,335 667 11,346 9.00 273.00 1,335 667 12,014 9.50 273.50 1,335 667 12,681 10.00 274.00 1,335 667 13,349 Culvert / Orifice Structures Weir Structures Thursday, 06 / 1 / 2017 [A] [B] [C] [PrfRsr] [A] [B] [C] [D] Rise (in) = 24.00 14.00 6.00 Inactive Crest Len (ft) = 20.00 Inactive 0.00 0.00 Span (in) = 24.00 15.00 29.00 0.00 Crest EI. (ft) = 272.75 273.20 0.00 0.00 No. Barrels = 1 1 1 0 Weir Coeff. = 3.00 2.54 3.33 3.33 Invert EI. (ft) = 264.00 264.00 269.50 0.00 Weir Type = Broad 90 degV --- --- Length (ft) = 30.00 0.50 0.50 0.00 Multi-Stage = Yes Yes No No Slope (%) = 1.50 0.50 0.50 n/a N-Value = .013 .013 .013 n/a Orifice Coeff. = 0.60 0.60 0.60 0.60 Exfil.(in/hr) = 0.000 (by Contour) Multi-Stage = n/a Yes Yes No TW Elev. (ft) = 0.00 Note: Culvert/Orifice outflows are analyzed under inlet (ic) and outlet (oc) control. Weir risers checked for orifice conditions (ic) and submergence (s). Stage (ft) 10.00 8.00 6.00 4.00 2.00 0.00 0.00 5.00 Total Q Stage / Discharge 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 Elev (ft) 274.00 272.00 270.00 268.00 266.00 264.00 50.00 Discharge (cfs) ROUTED HYDROGRAPHS Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D0 2016 by Autodesk, Inc. v10.5 Hyd. No. 3 STWM DEVICE Hydrograph type = Reservoir Peak discharge Storm frequency = 1 yrs Time to peak Time interval = 1 min Hyd. volume Inflow hyd. No. = 2- Post-Development Max. Elevation Reservoir name = Sandfilter Max. Storage Storage Indication method used. Exfiltration extracted from Outflow. Q (cfs) 18.00 15.00 12.00 • �� . �� 3.00 STWM DEVICE Hyd. No. 3-- 1 Year 0.00 - 0 120 240 360 480 600 720 840 960 1080 Hyd No. 3 Hyd No. 2 1111117�1 Total storage used = 11,246 cuft Thursday, 06 / 1 / 2017 = 17.30 cfs = 718 min = 23,262 cuft = 272.56 ft = 11,246 cuft Q (cfs) 18.00 15.00 12.00 • �� . �� 3.00 0.00 1200 Time (min) Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D0 2016 by Autodesk, Inc. v10.5 Hyd. No. 4 ROUTED FLOW Hydrograph type = Reservoir Peak discharge Storm frequency = 1 yrs Time to peak Time interval = 1 min Hyd. volume Inflow hyd. No. = 3- STWM DEVICE Max. Elevation Reservoir name = Vault Max. Storage Storage Indication method used. Q (cfs) 18.00 15.00 12.00 • �� . �� 3.00 ROUTED FLOW Hyd. No. 4-- 1 Year Thursday, 06 / 1 / 2017 = 9.231 cfs = 723 min = 23,257 cuft = 267.10 ft = 4,136 cuft � � � �— � � �� Q (cfs) 18.00 15.00 12.00 • �� . �� 3.00 r.na 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) Hyd No. 3 1111117� Total storage used = 4,136 cuft Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D0 2016 by Autodesk, Inc. v10.5 Hyd. No. 3 STWM DEVICE Hydrograph type = Reservoir Peak discharge Storm frequency = 2 yrs Time to peak Time interval = 1 min Hyd. volume Inflow hyd. No. = 2- Post-Development Max. Elevation Reservoir name = Sandfilter Max. Storage Storage Indication method used. Exfiltration extracted from Outflow. Q (cfs) 24.00 20.00 16.00 12.00 : �� 4.00 STWM DEVICE Hyd. No. 3-- 2 Year 0.00 - 0 120 240 360 480 600 720 840 960 1080 Hyd No. 3 Hyd No. 2 1111117�1 Total storage used = 11,339 cuft Thursday, 06 / 1 / 2017 = 22.05 cfs = 718 min = 33,712 cuft = 272.60 ft = 11,339 cuft Q (cfs) 24.00 20.00 16.00 12.00 : �� 4.00 0.00 1200 Time (min) Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D0 2016 by Autodesk, Inc. v10.5 Hyd. No. 4 ROUTED FLOW Hydrograph type = Reservoir Peak discharge Storm frequency = 2 yrs Time to peak Time interval = 1 min Hyd. volume Inflow hyd. No. = 3- STWM DEVICE Max. Elevation Reservoir name = Vault Max. Storage Storage Indication method used. Q (cfs) 24.00 20.00 16.00 12.00 : �� 4.00 ROUTED FLOW Hyd. No. 4-- 2 Year Thursday, 06 / 1 / 2017 = 12.55 cfs = 723 min = 33,708 cuft = 269.23 ft = 6,954 cuft � �� � � � �� Q (cfs) 24.00 20.00 16.00 12.00 : �� 4.00 r.na 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) Hyd No. 3 1111117� Total storage used = 6,954 cuft Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D0 2016 by Autodesk, Inc. v10.5 Hyd. No. 3 STWM DEVICE Hydrograph type = Reservoir Peak discharge Storm frequency = 10 yrs Time to peak Time interval = 1 min Hyd. volume Inflow hyd. No. = 2- Post-Development Max. Elevation Reservoir name = Sandfilter Max. Storage Storage Indication method used. Exfiltration extracted from Outflow. Q (cfs) 35.00 30.00 25.00 �� �� 15.00 10.00 5.00 .rn.� STWM DEVICE Hyd. No. 3-- 10 Year Thursday, 06 / 1 / 2017 = 34.59 cfs = 718 min = 62,266 cuft = 272.73 ft = 11,560 cuft � 0 120 240 360 480 600 720 840 960 1080 Hyd No. 3 Hyd No. 2 1111117�1 Total storage used = 11,560 cuft Q (cfs) 35.00 30.00 25.00 20.00 15.00 10.00 5.00 1200 Time (min) Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 3D0 2016 by Autodesk, Inc. v10.5 Hyd. No. 4 ROUTED FLOW Hydrograph type = Reservoir Peak discharge Storm frequency = 10 yrs Time to peak Time interval = 1 min Hyd. volume Inflow hyd. No. = 3- STWM DEVICE Max. Elevation Reservoir name = Vault Max. Storage Storage Indication method used. Q (cfs) 35.00 30.00 25.00 �� �� 15.00 10.00 5.00 .rn.� ROUTED FLOW Hyd. No. 4-- 10 Year Thursday, 06 / 1 / 2017 = 25.47 cfs = 721 min = 62,261 cuft = 272.72 ft = 11,611 cuft Q (cfs) 35.00 30.00 25.00 20.00 15.00 10.00 5.00 r.na 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 Time (min) Hyd No. 4 Hyd No. 3 1111117� Total storage used = 11,611 cuft SAND FILTER CALCULATIONS PRo�ECT: 981 Crossing PROJECT NO.: "I4-'I O7 SHEET: 'I DESIGNED BY: RBR DATE: O5/ZF)/'I7 CHECKED BY: KAB �ocaTiorv: Sand Filter 1 Sand Filter Desi n Drainage Area: 5.18 ac Proposed Sedimentation Chamber & Filter Chamber Dimensions Impervious Area: 3.62 ac Sedimentation: Filter: Hmax:' 6.00 ft Width: 17.3 17.3 Depth of Sand (Df):Z 1.5 ft Length: 51.0 51.0 Sedimentation Surface Area (As): 880 sf Height: 3 8.0 8.0 Filter Surface Area (Af): 880 sf Single Vault: y Volume Calculations Rv 0.68 Hmax As + Af WQV:4 12,786 cf 2.0 4,795.0 WQV(adj): 9,590 cf 3.0 3,196.7 Minimum As + Af: 1,598.3 sf TRUE 4.0 2,397.5 Minimum As: 845.4 sf TRUE 5.0 1,918.0 Minimum Af: 733.6 sf TRUE 6.0 1,598.3 Proposed WQV:S 10,710 cf TRUE Underdrain Calculations Notes K of inedia:s 3.5 ft/da 1. Hmax between 2& 6 Safety Factor:' 10 2. Minimum depth of sand is 1.5' n of underdrain 0.013 3. An assumed height of 0.5' is included to account for the underdrains Slope: 0.00 % 4. Calculated using Schueler's Simple Method as described in chapter Underdrain pipe diameter: 4.0 in 3 of NCDENR BMP Manual Number of underdrain pipes: 3 pipe 5. The weir wall between the two chambers is assumed to be 0.5'. The area above the weir wall is included in the volume calculations. Q(peak):$ 0.178 cfs 6. K value of 3.5 ft/day taken from chapter 9 of NCDENR BMP Manual Q(Average): 0.089 cfs 7. Safety factor should vary between 2 and 10 per section 5.7 for the Q(Underdrain): 1.78 cfs NCDENR BMP Manual Min. Diameter (single pipe) 21.9 in 8. Q peak calculated using Darcy's equation. Min. Area (single pipe) 2.618 sf Proposed Area (underdrains) 0.262 sf STIMMEL ASSOCIATES, P.A. 601 NORTH TRADE STREET, SUITE 200 WINSTON-SALEM, NC 27101 (336) 723-1067 DRAINAGE AREA EXHIBITS �� �� I���� 6p1 N. TRA�E ST�tEET, SUITE 2{)0 n'" � WIIUSTON-SALEl111, NC 271 al www.stimmelpa.cosn 336.72�.1467 LAkOSCAPE ARCFfITECTLIftE CIVIL E�[tiIWEERING LAND PLAND111+EG PRE-DEVELOPED CONDITIONS �� NOTE: SOIL TYPES PER �` USDA WEB SOIL SURVEY MAP DRAINAGE AREA BOUNDARY dat2: 05-16-2017 jOb #: 14-107 project: g81 CROSSING scale: 1�� = 120° sheet i of i d2SCClptlOn: SITE COVERAGE PRE-DEVELOPED CONDITIONS � � � � i� � �, � � � `� � . � ��.�' � � �� a�: - �•� � ������ WKE 1 --, �� �� � � _ �-- �- SOIL CLASS — BOUNDARY, CeC2 TYPICAL � \ SOIL CLASS � \ o BOUNDARY, TYPICAL � � ��-��� ♦� ,,�� � �-�' � � � � � � � / � � � ApC2 ApD� � � � , � � �� � � PROPERTY ` BOUNDARY , _ � �. � - - _ - -_ _ - -- - NC HIGHWAY 98 C�RAI�IAC�E AREA = 5.175± �cres Pre Dev Open Areas ApD: 107,736 sf = 2.473 Ac. ApD: 4,205 sf = 0.097 Ac. WKE: 11,582 sf = 0.266 Ac. ApC2: 30,739 sf = 0.706 Ac. — `� \ � SCALE: 1" = 120' Pre Dev �20 0 �Zo I m pv. Areas ApD: 30,739 sf = 0.706 Ac. ApD: 2,842 sf = 0.066 Ac. WKE: 25,098 sf = 0.578 Ac. ApC2: 12,304 sf = 0.283 Ac. i,,�""� ��� i���� 6p1 N. TRADE STitEET, SUITE 2{)0 date: 05-1 s-2o 1 � j Ob #: 14-107 WIIUSTON-SALEl111, NC 271 al ro ect: g81 CROSSING - www.stimmelpa.cosn 336.72�.1467 p J LAkOSCAPE ARCFfITECTLIftE CIVIL E�[riIWEERING LAND PLANNIkC, SCale: 1�� = 12�° sheet 1 �f 1 d2SCClptlOn: SITECOVERAGE POST DEVELOPED CONDITIONS POST-DEVELOPED � � � CONDITIONS �� � � � � �. % NOTE: SOIL TYPES PER �� �, � �:�� _ � o� Bou DARY, USDA WEB SOIL SURVEY MAP O � s' 1'-' � � � TYPICAL � � � � P � .� � �� 7 �������� s� � a � ��, �:��- _, � � DRAINAGE AREA �� �j'� � ��.. � � � � ` BOUNDARY � .r;'�' ��- � �'� � , � � .w, � ,�` � / �� 1. -,.� , � / ,��`yX V . .:vr 5 If ' , � a � '� � � �� � � � � �� � � .s%r����� -, � � �� � � �p� Ap�2�� ��� ApD � � ��`� i � . .��. � � � � � � € , ���� � �,�� � � � f f � ': >n; j�. � � � � ,�.e. ��'s�' -x: ` a. " _ � � � � WKE � � PROPERTY / 1 BOUNDARY � � �r ,�, — — a��_ _ . _ _ �� -- -- --- --- - -- .� �� - -- _ NC HIGHWAY 98 1 BOUNDARY, CeC \ \\ � TYPICAL � �� � �� IDRAINAGE AREA = 5.175± acres 120' 120 SWM PLAN AND DETAILS GRADING, AND DEMOLITION NOTES: ,, � �,� �� � � � � , �� � , , , 1. PRIOR TO ANY CONSTRUCTION GENERAL CONTRACTOR TO VERIFY THAT ALL REQUIRED PERMITS ARE ON / 1, - � / o ° , O\\ �° � �� � °4 I I � I FILE WITH THE APPROPRIATE AGENCIES. / //// / �� II � CI45 _ � S Q Q��\\� g1� �/ � J I I I I I I I I 2. CONTRACTOR TO MAINTAIN STREETS TO BE FREE OF SEDIMENT DURING ALL PHASES OF CONSTRUCTION. � EL 28622 GRATE - 28575 �/ � I a / � /// ( I I I I I I � / EL 286.22 � � INV OUT = 282.10 ° \� �� I 3. GC IS RESPONSIBLE FOR VISITING THE SITE IMMEDIATELY AFTER EACH RAIN TO INSPECT FOR EROSION �// �/ �/ ��� I � � � / p �\ \\ I I I \ I I I ENTERING THE STREAM RESTORATION AREA AND FIXING IMMEDIATELY. � � a � 6, �� � � I��g / \\ I I I I 4. THE EXISTING UTILITIES AND OBSTRUCTIONS SHOWN HEREON ARE FROM THE BEST AVAILABLE RECORDS � � � �F -a � �� � �� I �� / � �' � I I AND SHALL BE VERIFIED BY THE CONTRACTOR TO HIS SATISFACTION PRIOR TO CONSTRUCTION. NEITHER �� � - � � N � \ � ° � � , �� � � � \ � � � I I THE OWNER NOR THE LANDSCAPE ARCHITECT OR THE ENGINEER WARRANT OR GUARANTEE THE �/� � � � Zgg � �P� \ ��� � - � � � o � �� � � � � I �� � � � COMPLETENESS OR THE CORRECTNESS OF THE INFORMATION GIVEN. NECESSARY PRECAUTIONS SHALL BE � / / � _ _ 1 �// � � I TAKEN BY THE CONTRACTOR TO PROTECT EXISTWG SERVICES AND MAINS, AND ANY DAMAGE TO THEM DUE � � � a N� \ � � __ 7� °3 �� q�� � � � � �� / �/ O a I I I I I I TO HIS NEGLIGENCE SHALL BE REPAIRED IMMEDIATELY AT THE CONTRACTOR'S EXPENSE. � Ex- �- � % ��' � CI 44 9� C� � � �\ � � � I � �� � � �1, � co 1 l � � � GRATE = 285.73 � - - _ _ _ � 5 RCP� �� � 289- � � � �� �� � � J � �� � � � � � � 5. GENERAL CONTRACTOR TO VERIFY PROPER COVER OVER ALL EXISTING UTILITIES WITH PROPOSED GRADES. ��� _ CI 43 W� �� -� N � � � 2�p� INV IN = 282.30 (CI 45) -�� _ �� �� / �� / � �� � I � I I i 6. PRIOR TO PLACING FILL ALL FILL AREAS SHALL BE STRIPPED CLEARED AND GRUBBED TO REMOVE TOPSOIL � / GRATE - 284.25 '�' J � INV OUT - 282.00 - � �� \J/// �� / ,� 7 � � \ � GRATE = 286.25 � _ - - \ I � I � �' ` g2 I I I I I I STUMPS, ROOTS, ORGANICS AND OTHER UNSUITABLE MATERIALS. STRIPPINGS SHALL BE STOCKPILED OR � INV OUT = 281.00 ' � � �� �� I I I REMOVED AS DIRECTED BY THE OWNER. / /�// / / i �° EL 286.61' .� 2g� , INV OUT = 280.74 \ � -- __ � \ 2 �� I I I I 7. ANY BORROW WILL COME FROM A SITE OR SPOIL WILL BE PLACED ON A SITE APPROVED BY THE PROPER � / CI 43 a _\ r\��� � , \ ��^ �\ � � � STMH 15 29� � / � g2 I I I I JURISDICTION HAVING APPROVAL AUTHORITY OVER THE SITE. A SITE SPECIFIC SEDIMENTATION & EROSION / �/ � GRATE = 284.25 TC 287.05 2g LF 15" RCP @ 1.00% TC 287.24 � � GRATE = 292.73 � 292 2 �'�9 -- -- 2 I I I I CONTROL PLAN MUST BE APPROVED FOR ANY BORROW OR WASTE SITES. GC IS REQUIRED TO OBTAIN p' • �/ �/ � � TC 290.74 o INV IN = 287.02 (CI 16) APPLICABLE PERMITS BEFORE PRE-CONSTRUCTION MEETING. / / INV OUT = 281.00 i!� J I��83 LF 15" RCP @ 3.87% �\ 287 \ � G� INV IN = 285.97 (CO 21) TC 293.89 � / a , I I I I I I �j / / 2 4.84 � TC 286.87 � 288 � 289 INV OUT = 287.02 TC 294.29 � � I I I I 8. ALL STOCKPILE AREAS ARE INTENDED TO DRAIN TO AN APPROVED SEDIMENT TRAPPING DEVICE AND SHALL � / � � 284•93 � TC 287.74 � 290 � = EL 294.50 - 2g TC 293.62 w I I I I I I BE WITHIN THE LIMITS OF THE DISTURBED AREA SHOWN. � � TC 284.56 � co TC 286.16 �� _� � /_ �- 4 z � ��� � � � CI 1'G `b `�2� � TC 288.33 � � o � N � � EL 294.50� a � � � � � 9. THE DISPOSAL OF DEMOLITION AND/OR CONSTRUCTION DEBRIS IS NOT ALLOWED ON SITE. ALL SUCH DEBRIS � � GRATE = 286.09 ��� , r'cp c' / - _ � __ � _ � TC 294.14 � N I I � � TC 286.54 -� ' a� � TC 294.59 � � o� � SHALL BE DISPOSED OF OFFSITE AT AN APPROVED DISPOSAL SITE GC IS REQUIRED TO OBTAIN APPLICABLE � / INV IN = 278.80 (CI 13) �� ' �� O� TC 293.69 ��- o I 6, � �a 286.99 � � c� TC 29428 c� a� c� PERMITS BEFORE PRE-CONSTRUCTION MEETING. INV IN = 278.80 (CI 44) � ' TC 290.88 51 LF 18" RCP @ 1.18% TC 294.76 � � o� N I I I � I I I 10. SEE SHEETS C-2.1 AND C-3.0 FOR STORM DRAINAGE AND GRADWG PLAN. / INV IN = 278.80 (CI 43) a i ' � / I l c� � T29q4 � �� �� N li I I I I I I I I I� I / INV OUT = 278.70 I I � � %_� � TC 287.96 �� ��� 0 61 LF 18" RCP @ 1.00% 6> CI 16 � � �� � 66 LF 15" RCP @ 4.26 /o co , � o 11. CONTRACTOR TO MAINTAIN POSITIVE DRAINAGE AWAY FROM BUILDINGS AT ALL TIMES. 284.77 `L 102 LF 18" RCP 0.91 /o I TC 287.97 @ � > � � � � 284.97 � � � CI 13 �b � � N GRATE = 293.39 / � � � � � I 12. NCDOT DRIVEWAY PERMITS ARE REQUIRED FOR EACH CONSTRUCTION ENTRANCE PRIOR TO // i � 284.75 � � `�a' � �� GRATE = 287.46 � CI 14 � INV IN = 287.73 (CI 17) �� �� II PRE-CONSTRUCTION MEETING. GC SHALL ENSURE ALL DRIVEWAY PERMITS HAVE BEEN OBTAINED PRIOR TO / TC 284.74 � � � INV IN = 283.35 (CI 14) GRATE = 290.24 INV OUT = 287.63 � �� I I I I I PRE-CONSTRUCTION MEETWG. ' / 284:87 � �\ 52 LF 15" RCP @ 3.00% \ INV IN = 280.45 (YI 46) / INV IN = 286.41 (STMH 15) I �� ` EL 29378 , \r -� I I I I I I I � � � � � � INV OUT = 280.35 � INV OUT = 286.19 � 294.60 � � � � � � �� FLUSH 284.28 � `28 � � p� � 294.60 w \��/ / FLUSH 284.37 TC 285.88 ' L o � � ` �Y �� � , , � I ���o ( N I' I I I TC 287.84 � � °� TC 295.40 I I / / TC 285.17 TC 286.01 �- TC 287.99 \� N N I ry I QjN \ a' a a� � o o° � � a.� a°� a' , %g M � I I � I I � � �� I �I � � � �0 -- TC 287.21 � A � � � TC 295.40 � � � `� � � ` � � rn N � �� 285.71 �' � � � � � �=a �TC 295.28 � � � C117 � � � � / / � l TC 287_97 - - 67 LF 8" HDPE @8.07% ° I I I �, 42 LF 18" RCP @ 1.00% � � TC 294.72 0 � a � GRATE = 292.68 I I I TC 288.25 - - � TC 295.40; � � \ TC 293.18 INV IN = 288.75 (CI 18) I � /� � � � CI 11 - _ � � � � � �Y % �' / � --0' ' � INV OUT = 288.66 � � I CI 5 �g�` � \ , GRATE = 284.91 - - - � - ; y % / ° � a / � I � I I I I I � � GRATE = 284.13 �� 284.80 INV IN = 278.28 (CI 12) _ -� - -_ _ � ! TC 294.49 � o� � - � � INV IN = 277.96 (CI 11) / �- - - � INV OUT = 278.18 - - TC 290.64 -- / I � INV IN = 280.00 (CI 6) �'� � i � 290 _ TC 291.04 � � _ \ TC 294.71 / � N / / � � \ I I / \ / / INV OUT = 278.08 � � \� \ � \ i 287.04 / � - � � - - - � / � - TC 295.24 - o � \ , w I I I Q I ` � 284.73 � y oo � _ � _ x/ - a rn � z � � 283.51 � � � � � � � % � � � � � � o � � I 286.03 � o � / , � � � ��� � � 283.61 '� , , ` N � �i _ ��° a� / F�E 295./50 =� � � l \ � 285.97 % i / _ - a \ �'� 1 I I 1 1 I � � � � , 287.18 � � � � _ � TC 294.97 / / � � ' � I % � � FLUSH283.21 � / � IIIIIIII��� V � � ���,� �, � �- -� / � � � o a ' � �� 35 LF 18" RrP <<-- °� TC 295.37 TC 293.89 � 283.69, o � � 22 LF 18" RCP @ 1.00% � ' � - _�' - _ � N o � � PAVE 294.87 a `� TOP � 294.615 � � � � a � ° FLUSH 294.74 � � � � � � � � � � FLUSH 283.09 � <. � . ° � A I o _ _ � N N � _ INV OUT = 290.89 � � � � � � TC284.01 ��, o � e.., �. -_� rn / i � � � � A � �� � TC 2 .�47 68 LF 18" RCP @ 2.46 /o � 287.15 � c� � � �� � ; - j ' � � � � � � � TC 283.47 / � . � � � � � °� � / i � TC 295.24 0� � `3 � I 42 �� � � � � ° r � PAVE 294.87 p � ' TOP 295.37 � � �% � � � � � � � � �� C �,� � � TC 287.42 TC 288.38 , � 294.50 � �� GRATE = 282.96 � � � � ° ° � � � �o � � � � � � � TOP 295.37 295.50 �� � ' � � � INVOUT=278.00 � � ����� ��� � �4 � � � � TC288.58 � / � � v /1 � � � � 283.57 / ; N N- TC 293.53 295.50 TC 294.47 16 LF 18" RCP � 2.00%�f- ` � � � � � `� �" � 286.64 ,� r � ,' TC 288.74 PAVE 294.87 � � , � � � N TC 287.26 "� TC 293.36 � � � � � � � � TC 294�59 � � � � � � STM H 4 TC 283.20 / / 285.42 � � o � I ° c�� � i � � � ` �� � � RIM = 283.45 � � � �� � � �� I � � I _ � , FLUSH 294.87 295.00 � � � �T�� � o � � � '"� INV IN = 277.68 (CI 42) � � � 285.38 � � FLUSH 285.45 � � TC 293.70 ��2 � � � ° � �� � � � � � a � � � � � � �� � � INV IN = 277.73 (CI 5) , � � � FLUSH 285.53 � � � INV OUT = 277.58 � �� � i� � � . � � � � TC 287.21 � � 6� � ' ' '�' � 294.50 FLUSH 294.87 � g � ,n � N I � � ��� �� �' 15 LF 18" RCP @ 9.54% � � gy�/ 285.50 � , � TC 287.10 TC 288.49 � PAVE 2g4.87 295.00 � � �� � 1 � �� �' '� V / TW 282.81 �, � ��� � � � CI 6 �� 295.50 I � TC 295.08 � � �� � I � � � � �� _ CI 3 � � � � � i' � � � ::, 286.49 TC 287.30 i GRATE = 28671 �� � a � TOP 295.37 � � � ° TC 294.85 � � � � 132 LF 18" RCP @ 0.8% � � ,� GRATE - 284.68 � �� � � � � � TC 287.67 INV IN = 281.77 (STMH7) TC 292.86 � � �� � � � I / � �, INV IN = 276.14 (STMH 4) � � I � TC 285.54 �� TC 285.70 � � 286 57 � � INV OUT = 281.67 ' � 0 a� � � \ � � � � � � � � � � / ii / � � �� � " TC 293.61 F F = 29�. 'rJ� °'a a- _ cfl � � � INV OUT = 267.54 �� i I I TC 285.68 � � � / � � � ' � i �� � � � �' I � �9 293 0� � � w ;/� V N Zag TC 287.2 I N o I I I I I I �� 12 LF 18" RCP 10.56°// i� I , I ' �X �,��, �, TC 287.48' I I I� � TC 29322 1 � � a� a , I �'',� @ , / � ;,'� , I _ ,-k � � � , � � i � � � I ti w �2/ ! � / o�. ; �;�,,� �, .� 2�� �� o � ��� I o i I I I � I /2 a aa � I , y / ; i � ,, 66 LF 18" HDPE @ 1.00% � \ I I I I ,� / STMH 35 / , I I�� � TC 288.27 STMH7 TC 289.76 � 93 LF 8" HDPE @ 1.00% 1 I I RIM = 280.50 / � i I I I��'2 TTC 288 02 TOP = 288.755 TC 289.81 � � � \ � � a �,��` I I I I I � INV IN = 268.00 (YI 36) o" TC 290.05 TC 293.34 a � i 1' I I I � I N V O U T = 2 6 6. 7 7 / c y� b j TC 288.26 INV OUT = 282.4 �o� C O 2 2 PAVE 2 94. 87 � I I I � / � T C 2 8 9. 8 0 \ � TOP = 294.586 TOP 295.37 �I \ � `� T C 2 9 4. 2 2 ' � I I I I I I I 4� A P P R O X I M A T E �/ � j� I ��� \ T C 2 9 3. 1 7 c� i �a'' I W A T E R M A I N� I / _� � 4 I �, I' I � � � p I N V O U T = 2 9 1. 9 2 0 � a� � N � I I / LOCATION PER GIS �/ / N � ` a\ � J � � '- \��. ,; � ' N N `� T C 2 9 3. 7 1 I 1 � ( a I I I I I I I I �� / / / �` f � � , � I �. TC 290.35 TC 293.19 � � \ � = I w 74 LF 18" RCP @ 1.00% / / I � � �. li � TC 288.36 TC 290.11 / / /, / ��S ' I I TC 290.43 � I � 1 � e. / % i i I � I I I I � ��/ � °� I ' � Tc2so.2o � / FFE N295.5�0 \ T C 2 9 3. 9 8, � c i � s _ I I I I I� / �� � �' L� � 2 8 8 I � I C I 9 �, � _ � a •�,� T C 2 9 4. 2 5 G R A T E 2 9 3. 1 8 � '� cb � , � �� � i , � �� TOP = 288.400 � \ j INV IN = 289.91 (STMH 19) I I I I I I C� 20 LF 15" EXIST RCP @ 11.10% � BW ��9.00 � �N �S� � � I ��� j � � INV OUT = 285.30 � TC 288.32 � � � � �� TC 294.20 INV OUT = 289.81 � � � � Z L � � � � � TW 289.75 ryQ>O ^ / / � I I i i I i i �,i � � 18 LF I 46 LF CI 10 TC 292.82 TC 293.72 � a i 1 ---_ / TC 294.25 % /// / I I I (n �' , CI 40 � � � 15" RCP TOP = 290.058 TC 293.51 � / / - i DOGHOUSE STRUCTURE �' TC 289.35 i TC 289.63 i I � II @ 2 23% 15" RCP / I ;� � i ",�- I I °@ 1.00% � INV OUT = 282.99 52 LF 8" HDPE 1.00% N � I I � � W TOP = 27970 / � � ! � I � � 288.93 � � TC 289.43 � � � TC 290.45 �� � � ' � a � o � �� � � � � INV OUT = 273.14 � /� � �' 2892gg.06 �, j� `' 289•02 �` �� � g�-� TC 289.38 � TC 290.69 TC 292.84 _ CO 23 � o° � 56 LF 15" RCP @ 0.81 /o i o� � � � �� � � 28 a TOP - 294.540 � � N � o� o � � YI 36 ^ ^ M I I I I � TC 289.52 � 50 LF 15" RCP @ 1.79 /o TC 290.91 \ TC 292.91 - _ � N i �b N I INV OUT = 292.54 cv � NCDOT STD. 840.04 � � � I �� ��� I � .� �I I � i� � � 37 LF 12" HDPE @ 1.08% TC 290.86 N � ��� _ �g� � �� � � � � � � �c� � � ( � � � i � � i� � � THROAT = 274.61 co II 56 LF 24" RCP 1.50% N � 0 ___ `u � °' I � INV IN = 268.84 STMH 37 �N � � � � � � � -� � � � s' CO 28 � � � @ 3.00 /o � °' � TC 294.75 � � � � � � N � � � 28 LF 12" HDPE ° / STMH 25 � � TC 295.23 �� � T_'I I� I I ��� � � I � FLUSH 289.50 ' TOP = 290.101 � � INV IN = 270.87 (CI 40) r TC 289.98 vf INV OUT = 285.00 � 29� STMH 24 TOP = 291.851 TC 294.90 �� o STMH 19 °�� � � �� INV OUT = 268.74 AD 33 I FLUSH 289.97 I I INV OUT = 287.05 i TC 292.! 294.14 295.50 - / TC 294.74 GRATE = 294.30 I � TOP = 289.881 ' � I I I I � I 290.00 290.00 TOP = 290.871 / I 292.09 292.91 295.48 / I I/' /I / // I INV OUT = 286.00 ' � � I ' 290.00 ' � INV OUT = 285.40 291.50 291.50 TC 292.53 � TC 295.37 TC 295.35 INV IN = 290.47 (CI 20) ' TC 294.96 I I I / � C� 29 �� �I ' 78 LF 12" HDPE 2.00% ` 295.00 INV OUT = 290.37 � �' �� N � / � � I � ( � � � � � � I TOP = 290.126 290.00 � � � � � � 26 LF 8" HDPE 1.52% , i 45 LF 12" HDPE @ 1.00% ��� 295.50 � - I INV OUT - 285.50 MODULAR RETAINING WALL O BE o � / � � I TC 294.75 a TC 295.38 a _ aP I �� 63 LF 15" RCP @ 1.00 /o I I TC 290.37 \ � TOP 290.87' / U U TC 29323 �" � a / I I I I I I D IGNED BY A PRpFESSIONAL ENGINEER, I i I a � U �_ � o � � TC 294.73 ° � � 0� I�// I/ I I I PLANS TO BE PROVIDED AS PART FLUSH 291.87 c9 � I I I � o PAVE 289.87 'I PAVE 289.87 � PAVE 290.87 PAVE 290.87 FLUSH 291.87 TC 292.37 cP EL 292.68 �' � / �� ONSTRUCTION OCUMENTS AT TIf�IE OF �^ ^ ^ co rn ' PAVE 291.87 PAVE 291.87 FLUSH 294.67 TC 295.38 ' FLUSH 292.85 ) I I r� � N' , TOP 290.37 TOP 290.37 � PAVE 290.37 TOP 291.37 o PAVE 291.87 PAVE 291.87 I / FINAL PLAN A�ROVAL BY THE TOWN. %�N <v N c� I I' � I �, ` �, o� �, w o o ' � � � � � I �� � � I R ��4 j � � � � � � � STMH 2 I � � 290.37 ° i � � � � ` ° TOP 290.87 � _ a TOP 292.37 � FLUSH 292.98 �� � � o � � � . TOP 290.87 � �, a �' � TOP 292.37 � � \ � I TC 289.95 � I � i 1 I ' � ��` TOP 291.37 A� I��I o I D TC 29� TC 294.86 TC 294.60 � / / / I I RIM = 289.47 � j� � 290.50 ` 290.50 291.00 N- 291.50 � 291.81 � � a , � TOP 292.37 "✓ �` 292.50 ao EL 293.29 � / / / I I I I INV IN = 263.16 Q i 292.00 �-292.37 f� , EL 293.27 , 33 LF 15" RCP 0.85% � 1 \ 290.50 291.11 � 292.50 292.50 �°�° CI20 i @ \ \ � INV OUT = 263.15 I , I I I PAVE 290.37 � 290.50 z91.00 C � � TC 293.36 0 1 0 0 2y� _, _ TC 294.03 � I I _ RATE - 2 . � I G 93 33 I � \ � � 291.00 � 291.50 STM H 8 � � � �� � � � � � � � � tH-��-���-� ---��=�fE-�f -H � - N I � � ' '� � �a r , � � '� � EL 293.98 INV OUT = 290.75 / � I � � � �� � FLUSH 290.37 � � FLUSH 290.37 RIM = 290.55 � � 0 � EL 292.68 �� � � � N I i � A o TC 293.83 � � I I I 1 I I I � �D / STMH 1 °� � � - INV IN 284.55 CO 28 I � � � � � � 46 LF 12" HDPE @ 1.01% INV IN = 284.55 (STMH 24) �p o � TC 293.43 � � � � ��� � � � � � � � RIM = 279.69 � N ' � � � � � � � 36 LF 12" HDPE 2.95/0 �� � i INV IN = 262.46 STMH 2 � � � \ � � , TC 292.89 ° EL 293.59 � � p � ° � � � INV OUT = 262.36 TW 290.55 � � I '' � � � � � AD 30 � � � , �� � INV OUT = 284.45 AD 26 c� -- � � � �/ � � � � � � � � � � ��/ � � � � � I I I Tc z8s.as GRAT�2�D•� Z9O � FFE � 2..0 ' F E- 291.50 � _ � GRATE = 292.25 EL 294. � , / / I �, BW 282.50 0 1 - p p EL 293.50 D \ I 46 LF 24" CLASS IV RCP @ 1.50% � � � I � � � � ' „ � INV IN = 286.16 (CI-31) � � � \ � FFE - `�9`�.�0 INV IN - 288.13 (CI 27) �° _ �/ / � �� � � � � I I N N I I STMH 37 N �`� RIM = 277.27 � ' � c� �� I INV IN = 269.57 (STMH 38) � INV OUT = 269.47 � � � o 62LF15"RCP@1.00% � � I N \ ��� � � � ;,� I � �� � � � � � � �� � � M � I N 1 � 62 LF 15" RCP @ 1.00% � \ �, � TW 290.22 �30 LF 15" RCP @ 11.10% � � � � n � BW 284.50 � �\ � �\ \ \ TC 290.61 \ � \ EX CI 41 � � � � � � GRATE = 284.51 � �� � INV OUT = 280.30 � �� � � °�°, STMH 38 � � � � A � RIM = 279.53 INV IN = 270.29 (YI 39) � � INV IN = 276.98 (EX CI 41) I `JcP�, � INV OUT = 270.19 � � � \ \ �� .� � � � � � �28�_ - _ - � ( � � � ���� � . , \ V � � ��� � � � � V�1 LF 15" RCP @ 1.00%�� �t � \ � _ � � � � � � �� YI 39 - NCDOT S' -288 � � � � � � 840.18 & 840 GRATE = 274 \ INV OUT = 271 \ \ \ \ \ V� ,`.� . � .� .. k i INV OUT = 286.06 / \ \ \ �\ \ � INV OUT = 288.13 0 � D / / //// / � / I I I I / � o 12' HDPE � I � �� �� � � 30 LF 12" HDPE @ 1.08/0 � / � ���'�� � � � � � I \ � � - � I v , � � �� @ 1.03% I I I / �� \ � N � � / / / � I I I � \ \ � , / / / / / � I � CI-31 _ AD 47 _ � � �� � � �� �` ,.�� `Z93 / / j � , GRATE - 288.99 � GRATE - 290.27 � � V ` � \ � TC 289.81 INV OUT = 286.23 � / \ INV OUT = 285.00 \ \ \ \ \ \ 292.30 O' TC 292.98 `L�1 / //� / / / / � / / / a i � � � � � CI 34 � �� � � \ �� � �g j ���/� � � � GRATE = 289.69 � FLUSH 292.39 29�•50 � 0 � � 13 LF 8" HDPE (c� 1.46% j INV IN = 284.81 (AD 47) \ \ �'�9 � FLUSH 292.39 N � TC 292.19 � / � / / / � / � � v_ _ a �NV �UT 276.23 \ \ � ? � � \ TC 292.1� \ TC 292.64 / / �/� / � ° TC 291.81 � � 290.50 � 290.75 � � 291.25 � 291.50 � � � • � TC 292J9 TC 292.28 � � � �� j % � � � � � � � 291 � � � TC 291.33 292 � � � � �/� / � \ \ TC 291.07 TC 291.71 290 � �_ � � // � / / / / � � � � TC 289.89 � � � " 29 i I � � TC 290.57 � 2 �9 � A � � � �-• � ` � � � � 85 � , � � � / � �/ ��i�� � � � � � TC 290.99 V � V � � / �� � �� ��� 3 � ' 290.50 �-TC290.40 290 � � . � � � � � � � � � � �� � ��� �� � V 290.50 289 � � � � A � � � �� �" �Q �'N � 288 � 287 � � � � � A � � � _ _ _� --i�, 5, �`'�°,o�N�� /� ) SEE SHEET C-3.0 FOR OVERALL GRADING PLAN � \ �� 285 286 �� � 285 \ � � A _ /� � SLOPE p CLASS "A" RIPRAP '� ������A 284 a \ \ \ \ \ _ _ / � �� GRAD//�G P R 6" MIN. THICK LINING / �/��/�� � zaz zas � � � � � _ � � j �� i � ( � � � j � j��� / , � � 2sa � o � � _ � � \ � � � , � i � � j%/� �o ��// � � 280 51 LF 10" HDPE @ 10.00 /o � � � � � � � � i �. ' '�"�� �' � � � � � � � � i � � / / i � i i `�i��/%�/j a o � � �/// � � zo o zo 4o so 279 ' � � � �" � � � >�. � _ � � / Zg5 / / � / / �V�j� ��J �� � � � 277 %�'-� , / � / �� � -a��� �/� / / �� / / / � GEOTEXTILE �����/���A���� � � �, � � � � , , ,�� i _ ' / - � �/ / / / / UNDERLINER � �, � � � ' ' � / � �' �� LINE DITCH WITH CLASS "A" RIPRAP. / � � V �� _ _ 75 _ - - ' ' �� � � A� ,SEEDITCHLININ�CTION� HISSHEET. � / / � �� � � j j � DITCH LINING SECTION A-A � T � -'� �- --- �� � � ���������-�-�� � / / / �/ / � � rvoTToscn�e � � ,�i7 �����.�,�.�� �����.1G�J�� ���- / i � � � � � � .,n i i � ��i��������/�������������� �OI'l�l SCALE: 1" = 20' � stimmel LANDSCAPE ARCHITECTURE CIVIL ENGINEERING LAND PLANNING 601 N.TRADE STREET, SUITE 200 WINSTON-SALEM, NC 27101 P:336.723.1067 F:336,723.1069 www.stimmelpa.com SEALS: PROJECT: CLIENT: Moseley REA 1100 Kenilworth Ave, Suite 210 Charlotte, NC 28204 704-927-9210 Contact: Bill Moseley DRAWN: KB,RBR,KAB DATE: 02-02-2017 REVISIONS: 1 04113117 TRC COMMENTS 2 05/08/17 CLIENT / TRC COMMENTS 3 05/30/17 NCDOT COMMENTS .IOB. NO: 14-107 SHEET TITLE: FINE DETAIL GRADING AND STORM DRAINAGE PLAN SCA�E: AS NOTED SHEET NO.: C-3.1 QC STIMMEL ASSOCIATES, P.A. .3 0 0 , � 0 i � � � A A SEAL PENETRATION °. ° a a a o a W/ A NON-SHRINK � �`a ° a� a� GROUT TO PROVIDE A WATERTIGHT SEAL. a 6" . i 24'� RCP OUT " INV: 264.00 FLOW a � �� FLOW � STEPS (ASTM 478) CENTER WITHIN HATCH OVERFLOW _ � STRUCTURE - 6� 9 a a aQ 10 � N STEPS (ASTM 478) CENTER WITHIN HATCH a . e' � � ' - .' . . ' � . . - d� � d ° '. - . ' . a a � A- PLAN VIEW OF PRECAST TOP FLOW 18" RCP IN INV: 266.25 oa , a a a a: . a d 8 I aa. .� a ��. °� �� o �. . ° � � ° � ° � �a � °. �I. o 31' 1,130 SQ. FT X 9.25' = 10,452.50 CU. FT. STORAGE 41' � N � FLOW 18" RCP IN v INV: 266.25 aa a 4 a 1� o l `° i°��� °�°a 1 d° a � da I � I q MIN. 8" THICK SLAB SEDIMENTATION CHAMBER I a s� � °° . 4" SCH 4Q PVC UNDERDRAIN W�TH � 6" I 3/8" PERFORATIONS ON 6" CENTERS 1,785 SQ. F1' X 6.0� � '"� . ON ALL FOUR SIDES (AASHTO M278) = 10,710 CU. FT. STORAGE a � r7 _: .. • . . . - - ,.. , . . ,: • . . a SEAL PENETRATION TO ` ` ` - . - PROVIDE A WATERTIGHT SEAL � _ . -,. - TYPICAL ALL PENETRATIONS . ' ' ci.EANouT (rrP.) c5o4 SAN D C HAM B E R s' TYPICAL� � �` .� � a -� � a 51' o I - - _ . _. 25' _ a ��� TYP : � " ' . _. � ;.,_ �: , , _ _ . _ , _ - , : ,. � - . I - .a� a . dla .a. I --a. Ia � .. I. � � _ . d. Q � a 4 0 � ; . ad . - . . ��, . QQ . , . .a _ Q .. .a. .a -. d. Q . . � ° . a a �� a. a A o , a a o a �; a WIER ELEV. = 272.75 I OVERFLOW WEIR I � 6" H X 29" W ORIFICE � INV. 269.50 � INV. 24" OUT = 264.00 � 14" H X 15" W ORIFICE f � L � INV. 264.00 MIN. 8" TH1CK � BOTfOM SLAB PRECAST SANDFILTER VAULT NOTES: 1. THE PRECAST CONCRETE VAULT SHALL BE DESIGNED IN ACCORDANCE WITH THE FOLLOWING: A. CONCRETE COMPRESSIVE STRENGTH OF 5,000 PSI � 28 DAY MiN. (ASTM C94) B. STEEL REINFORCING BARS ASTM A-615 (Fy=60 KSI) C. STEEL REINFORCING WIRE ASTM A-185 OR A-497 (Fy=65 KSI) D. DESIGN LIVE LOAD: AASHTO HS-20 E. EARTH COVER: 3.0' MIN. F. SOIL UNIT WEIGHT 120 PCF G. DESIGN SPECIFICATION: AASHTO, 16TH EDITION & ASTM C 890 2. A GEOTECHNICAL REPORT IS AVAILABLE FROM THE OWNER. 3. ALL EXTERIOR JOINTS SHALL BE SEALED WITH CONSEAL 102 SEALANT. WRAP SIDE AND TOP HORIZONTAL JOINT WITH CONSEAL CS-212 BUTYL RUBBER WRAP (12" WIDE) 4. THE CONCRETE VAULT SHALL BE FREE OF SILT PRIOR TO INSTALLING THE UNDERDRAINS & SAND. 5. PRIOR TO FINAL CERTIFICATION, THE SAND FILTER SHALL BE FREE OF DEBRIS & SILT. 6. ALL VAULT WALL THICKNESSES TO BE DETERMINED BY PRECASTER, HOWEVER SHALL BE A MINIMUM OF 8" THICK. INTERNAL WALL THICKNESSES ASSUMED TO BE 6" FOR SAND FILTER SIZING CALCULATIONS. SANDFILTER SIZING TO BE REEVALUATED IF WALL THICKNESS VARIES. 7. IF THE SAND IS INSTALLED PRIOR TO THE SITE BEING FULLY STABILIZED THEN THE SAND FILTER SHALL REMAIN "OFFLINE (FLOWS DIVERTED THROUGH BY-PASS LINE) UNTIL ALL CONTRIBUTING AREAS ARE PERMANENTLY STABILIZED AND APPROVAL IS GIVEN BY THE ENGINEER TO ALLOW FLOWS INTO THE SAND FILTER. 8. SUBMITi'ALS ARE REQUIRED FOR THE PRECAST SAND FILTER VAULT, ASTM-C33 SAND, FABRIC, UNDERDRAINS, HATCH, JOINT DESIGN AND ANTI-FLOATATION ANCHOR. WASHED CONCRETE SAND (ASTM C-33) THE SAND SHALL BE A CLEAN ASTMC-33 MEDIUM AGGREGATE SAND WITH A SIZE RANGE OF 0.02 INCH TO O.Q4 INCH. FILTER FABRIC 6 OZ. NON-WOVEN MIRAFI N160 OR EQUAL BETWEEN SAND AND WASHED STONE. 18" RCP IN ''-,� � INV: 266.25 = � � FLOW � STEPS (ASTM 478) B CENTER WITHIN HATCH 94.25' CONCRETE FIELD POURED ANTI-FLOATATION BLOCK P LAN VI EW W�0 TO P 0 F P R ECAST WIER ELEV. = 272.25 � 1 1,681 CF DETENTION CHAMBER 1 a,71 a CF SAND FILTER CHAMBER 2 SOUD WALL C504 PVC C�EANOUT (TYP) TOP OF SAND E�EV. = 266.25 8" MIN WASNEO 57 STONE BEDDING PRECAST CONCRETE SAND FILTER SCALE: N.T.S. � COMBINATION WYE S ECTI 0 N A-A �'�P' THE GEOTECHNICAL ENGINEER SHALL CONFIRM THE SUBGRADE BEARING PRESSURE AND ISSUE A WRITTEN REPORT PRIOR TO SETTING THE STRUCTURE. LONG SWEEP 90' BEND - TYPICAL J # 57 WASHED STONE 30°X30" HATCH 4" SCH 40 PVC UNDERDRAIN WITH / 3/8'� PERFORATIONS ON 6" CENTERS -� ON ALL FOUR SIDES (AASHTO M278) FILTER MEDIA ENLARGEMENT 30'�X30" HATCH I � OVERFLOW WIER � NORMAL POOL °' � ELEVAT�ON: 266.25 n - � MIN. 8" THICK BOTI'OM SIAB �i� BACKFILL VAULT WITH �� APPROVED FILL MATERIAL W/ A MINIMUM UNIT WEIGHT OF 110 #/CF. CONCRETE FIELD POURED ANTI-FLOATATION B�OCK SEE SAND FILTER STRUCTURE DRAWINGS FOR DETAILS 36.5' SECTION B-B CLEAN OUT TO BE SET ABOVE SURFACE OF SAND � SURFACE OF SAND WYE F�TTING WITH LONG SWEEP UNDERDRAIN SEE PLANS FOR MATERIAL, SIZE & SLOPE 12" �=� OUTSIDE TOP ELEV. = 274.75 _���_ �� INSIDE TOP ELEV.: 273.75 -��i �I- SAND FILTER CHAMBER j�� OVERFLOW WEIR ELEV. = 272.25 I�I I =111� BACKFILL VAULT WITH APPROVED ������� FILL MATERIAL W/ A MINIMUM 1���I11 UNIT WEIGHT OF 110 #/CF. _�__��� TOP SAND: 266.25 I-�I I I� � TOP AGGREGATE: 264.75 aa. ���yFL00R ELEV.: 264.00 6" CLEANOUT ADAPTER W/ THREADED PLUG NOTES: 1. CLEANOUT SHALL BE SOLID WALL SCH. 40 PVC AND SHALL BE VARIES SAME SIZE AS SEE PLANS UNDERDRAIN UNLESS NOTED OTHERWISE ON THE PLANS. C�EANOUT DETAI � SCALE: NTS � stimmel LANDSCAPE ARCHITECTURE CIVIL ENGINEERING LAND PLANNING 601 N.TRADE STREET, SUITE 200 WINSTON-SALEM, NC 27101 P:336.723.1067 F:336.723.1069 www.stimmelpa.com SEALS: NCBEES CERT. NO.: C-1347 �\\1111111//�� \���,�N CAR ��i ....,0 i� ���` p� • S � • C��i �i � • . � = . AL r _ _ • 3 76 • _ ' �• ���� � � ���'L� �.�GI NE� .��,�v��• �'�,,tiF /'H Ai Ig\���� I PROJECT: � � ~ z �W �n �1..� O J W � U W z � ��/'� � VJ VJ w w � � O O � � � � Q Q � � � CLIENT: Moseley REA 1100 Kenilworth Ave, Suite 210 Charlotte, NC 28204 704-927-9210 Contact: Bill Moseley DRAWN: KB,RBR,KAB DATE: 02-02-2017 REvisioNs: 1 04113/17 TRC COMMENTS 2 05/08/17 CLIENT I TRC COMMENTS 3 05/30/17 NCDOT COMMENTS ,1oB. NO: 14-107 SHEET TITLE: SAND FILTER VAU LT D ETAI LS SCA�E: AS NOTED SHEET NO.: C-6.7 cQ STIMMEL ASSOCIATES, P.A.