HomeMy WebLinkAboutNC0003042_More Information (Requested)_20170714Water Resources Environmental Quality July 14, 2017 CERTIFIED MAIL 7002 0860 0006 58361110 RETURN RECEIPT REQUESTED Mr Thomas S. Warren, Jr City of Roxboro P.O. Box 128 Roxboro, NC 27573 Dear Mr. Warren: ROY COOPER Governor MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director Subject: Request for Additional Information Renewal Application Roxboro WTP NPDES permit NC0003042 Person County The Division has reviewed your application, received on October 3, 2016, for renewal of NPDES permit NC0003042 To enable us complete our review in accordance with N.C.G.S. 143-215.1 and 15A NCAC 2H.0105, please provide additional or revised information to address the following comments: 1. Please provide five (5) days of Total Hardness (CaCO3 or (Ca + Mg)) data for the effluent at Outfall 001. 2. If flow is present In the receiving stream, please provide five (5) days of Total Hardness (CaCO3 or (Ca + Mg)) data upstream from Outfall 001 Review of our records indicates that there is no stream flow data documented for the receiving stream. Please provide a 7Q10 and 30Q2 at the location of Outfall 001 [36.411944°, -79.001111°], for the unnamed tributary to UT to Marlowe Creek from the following contact with the US Geological Survey: J. Curtis Weaver, Hydrologist, PE USGS North Carolina Water Science Center 3916 Sunset Ridge Road Raleigh, NC 27607 Phone- (919) 571-4043 // Fax. (919) 571-4041 E-mail address -- jcweaver@usgs gov Internet address -- httn://nc.water.us sg aov/ The NC 2007-2014 Water Quality Standard (WQS) Tnenmal Review was approved by the NC Environmental Management Committee (EMC) on November 13, 2014. The US EPA subsequently approved the WQS revisions on April 6, 2016 with some exceptions. The NC Division of Water Resources is required to implement the new dissolved metal standards in all permits public noticed after April 6, 2016. The new standards for most metals include acute standards Furthermore, the freshwater standards for several metals are expressed as the dissolved form of the metals, and seven metals have hardness - dependent equations. As a result, the Division will need site-specific effluent hardness data and instream State of North Carolina I Environmental Quality 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 919-707-9000 Mr. Warren July 14, 2017 Page 2 of 2 hardness data, upstream of the discharge, for each facility monitoring these metals in order to calculate permit limitations. The metal of concern for this permit renewal is Copper. To evaluate dissolved Copper, a Reasonable Potential Analysis (RPA) was conducted using data from DMRs (Feb2015 May2017). Please see the attached RPA spreadsheets for Outfall 001. Results indicated a reasonable potential to exceed the new dissolved metal standard for Copper. Consequently, the following daily maximum limits (acute standard) and monthly average limits (chronic standard) for Total Copper could be applied for this permit renewal: Parameter Outfall Monthly Average Limit Daily Maximum Limit Copper 001 7.88 gg/L 10.47 µg/L To calculate these limits a default hardness of 25 mg/L was entered for both the effluent and upstream values. Additionally, a 7Q 10 of zero was used for this calculation. For a summary of this information, please see the attached "Dissolved to Total Metal Calculator". Incidentally, the additional information requested will be used in a recalculation for the draft permit. If no response is received within 60 calendar days [per 15A NCAC 211.0107(b)], the permit will be renewed without the benefit of the requested additional information. Therefore, a default hardness of 25 mg/L and a 7Q 10 of zero will be used to calculate effluent limits for Copper as indicated. If you have any questions, please contact Derek Denard at 919-807-6307 or email at derek. denard@ncdenr. gov. Sincerely, Derek Denard, Environmental Specialist Compliance & Expedited Permitting Unit Division of Water Resources, NCDEQ he NPDES Permit Files Central Files RRO Files ec Danny Smith [danny smith@ncdenr gov] Thomas S Warren, Jr [twarren@cityofroxboro com] Freshwater RPA - 95% Probability/95% Confidence Using Metal Translators MAXIMUM DATA POINTS = 58 REQUIRED DATA ENTRY CHECK WOS T-, L.I., � �...:....a I..i..�.....,�:.... ❑CHECK IF HQW OR ORW WQS Facility Name City of Roxboro - Roxboro WTP ParO WWTP/WTP Class PC -1 ParO NPDES Permit NC0003042 ParO Outfall 001 ParO Flow, Qw (MGD) 2.325 ParO Receiving Stream UT to Marlowe Creek t ParO HUC Number 030101040602 Paro Stream Class 1 Copper ParO ❑Apply WS Hardness WQC C ParO 7Q10s (cfs) 0.00 Part 7Q10w (cfs) 0.00 Part 30Q2 (cfs) 0.00 Part QA (cfs) 0.00 Part 1Q10s (cfs).00 0 Part Effluent Hardness 25 mg/L (Avg) Part Upstream Hardness- _ _ _ _ _ 25 mg/L (Avg) I ----- Part Combined Hardness Chronic __ _ _ _ _ _ _ 25 mg/L- Part Combined Hardness Acute _ _ _ _ _ _ _ _I 25 mg/L I Part Data Source(s) BIMS DMRs DeC2012 to May2017-, flow June2014 to Part ❑CHECK TO APPLY MODEL May 2017 Part Part Par2 Par2 ,_ ...... ..-.,..,_. ..:.. .- -... ,.,-. _-.. ,- Par2 Follow directions for data entry. In some cases a Par2 comment menu list the available choices or a dropdown menu will provide a list you may select from. Error message occur if data entry does not meet input criteria. Table 2. Parameters of Concern Name was Type Chronic Modifier Acute PQL Units 1 2 3 4 5 s 7 a 9 0 1 Copper Aquatic Life NC 7.8806 FW 10.4720 ug/L 2 3 Fluoride Aquatic Life NC 1,800 FW ug/L 4 5 6 7 s s 0 1 2 3 4 5 NC0003042 RPA 2017, input 7/13/2017 REASONABLE POTENTIAL ANALYSIS H1 H2 "PASTE SPEC Use "PASTE SPECIAL Effluent Hardness I.lues" then "COP Upstream Hardness Values' then "COPY" Maximum data . Maximum data points = 58 points = 58 Date Data BDL=1/2DL Results Date Data BDL=1/2DL Results 1 25 25 Std Dev. N/A 1 25 25 Std Dev. N/A 2 Mean 25.0000 2 Mean 25.0000 3 C.V. 0.0000 3 C.V. 0.0000 4 n 1 4 n 1 5 10th Per value 25.00 mg/L 5 10th Per value 25.00 mg/L 6 Average Value 25.00 mg/L 6 Average Value 25.00 mg/L 7 Max. Value 25.00 mg/L 7 Max. Value 25.00 mg/L 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 24 25 25 26 26 27 27 28 28 29 29 30 30 31 31 32 32 33 33 34 34 35 35 36 36 37 37 38 38 39 39 40 40 41 41 42 42 43 43 44 44 45 45 46 46 47 47 48 48 49 49 50 50 51 51 52 52 53 53 54 54 55 55 56 56 57 57 58 58 NC0003042 RPA 2017, data 1 7/13/2017 REASONABLE POTENTIAL ANALYSIS Pall Par13 Use "PASTE SPEC Use "PASTE SPECIAL Copper Values" then "COP Fluoride Values" then "COPY" . Maximum data - . Maximum data points = 58 points = 58 Date Data BDL=112DL Results Date Data BDL=112DL Results 1 2/3/2015 4 4 Std Dev. 7.6239 1 4/7/2015 < 500 250 Std Dev. 39.7213 2 4/7/2015 < 5 2.5 Mean 9.2500 2 7/16/2015 240 240 Mean 235.5556 3 5/12/2015 6 6 C.V. 0.8242 3 10/20/2015 < 500 250 C.V. (default) 0.6000 4 6/2/2015 7 7 n 26 4 1/21/2016 < 500 250 n 9 5 7/16/2015 < 5 2.5 5 4/28/2016 < 500 250 6 8/11/2015 34 34 Mult Factor = 1.35 6 7/14/2016 130 130 Mult Factor = 1.81 7 9/1/2015 19 19 Max. Value 34.00 ug/L 7 10/20/2016 < 500 250 Max. Value 250.0 ug/L 8 9/15/2015 3.1 3.1 Max. Pred Cw 45.90 ug/L 8 1/26/2017 < 500 250 Max. Pred Cw 452.5 ug/L 9 10/20/2015 7.4 7.4 9 4/4/2017 < 500 250 10 11/17/2015 7 7 10 11 12/8/2015 5 5 11 12 1/21/2016 5.5 5.5 12 13 2/9/2016 5 5 13 14 3/30/2016 7 7 14 15 4/28/2016 7.8 7.8 15 16 5/10/2016 7 7 16 17 7/14/2016 22 22 17 18 8/9/2016 26 26 18 19 9/16/2016 11 11 19 20 10/20/2016 8.6 8.6 20 21 11/18/2016 9 9 21 22 12/19/2016 8 8 22 23 1/26/2017 < 5 2.5 23 24 2/6/2017 8 8 24 25 4/4/2017 6.6 6.6 25 26 5/8/2017 9 9 26 27 27 28 28 29 29 30 30 31 31 32 32 33 33 34 34 35 35 36 36 37 37 38 38 39 39 40 40 41 41 42 42 43 43 44 44 45 45 46 46 47 47 48 48 49 49 50 50 51 51 52 52 53 53 54 54 55 55 56 56 57 57 58 58 NC0003042 RPA 2017, data - 2 - 7/13/2017 City of Roxboro - Roxboro WTP NC0003042 Freshwater RPA - 95% Probability/95% Confidence Using Metal Translators Outfall 001 Qw = 2.32470968 MGD COMBINED HARDNESS (me/I.) Acute = 25 mg/L Chronic = 25 mg/L PARAMETER MAXIMUM DATA POINTS = 58 Qw (MGD) = 2.32 WWTP/WTP Class: PC -1 1Q10S (cfs)= 0.00 lWC% @ IQ10S = 100 7Q10S (cfs) = 0.00 IWC% @ 7Q10S = 100 7Q10W (cfs) = 0.00 IWC%@ 7Q10W = 100 30Q2 (cfs) = 0.00 IWC% @ 30Q2 = 100 Avg. Stream Flow, QA (cfs) = 0.00 IW%C @ QA = 100 Receiving Stream: UT to Marlowe Creek HUC 030101040602 Stream Class: C Outfall 001 Qw = 2.32470968 MGD COMBINED HARDNESS (me/I.) Acute = 25 mg/L Chronic = 25 mg/L PARAMETER NC STANDARDS OR EPA CRITERIA REASONABLE POTENTIAL RESULTS RECOMMENDED ACTION TYPE 11) a a r- Chronic Applied \Cutc tl :1)ct- 11trsPred(\t Allowable Cw Standard Acute: 10.47 Copper NC 7.8806 FW 10.4720 us_ I 2G 23 45.90 RP shown - apply Monthly Monitoring with Limit _ ___ _ __ ChiO111C 7.88 _ _ _ _ _ _ _ _ _ _ _ ___ RP shown - apply Monthly Monitoring with Limit 10 values > Allowable Cw Acute: NO WQS Fluoride NC 1800 F\V ug/L 9 2 452.5 Note: n <_ 9 Default C.V. _ Chronic 1,800.0 Limited Dataset (n<8 samples) - apply Quarterly Limited data set No value > Allowable Cw Monitoring NC0003042 RPA 2017 rpa Page 1 of 1 7!13/2017 Date: 7/13/2017 FACILITY: City of Roxboro - Roxboro WTP NPDES PERMIT: NC0003042 Dissolved to Total Metal Calculator in accordance with Federal Regulations, permit limitations must be written as Total Metals per 40 CFR 122.45(c) Receiving Receiving Rec. Stream DES NPTotal Suspended Combined Combined Instream Instream Effluent Stream Stream -Fixed Value- Solids Hardness Concentration Concentration Upstream 7O10(CFS) (MGD) MGD MGD (mg/L) (mg/L) (mg/L) Average (mg/L) (Chronic) (Acute) (mg/L) o.0000 0 ooao 0 000o z 3zn� to zs o0o z5 00o too.0000 t00.0o00 25 25 Upstream Hard Avg (mg/L) = 25 EFF Hard Avg (mg/L) = 25 US EPA Maximum Allowable Effluent Concentration COMMENTS (identify parameters to PERCS Branch to maintain in facility's LTMP/STMP): Dissolved Metals Translators- using (MAEC) as a Total Metal PARAMETER Default Partition =Dissolved Metal -Translator ChonicrAcute Coefficients Chronic Acute u /l u /I streams u l u i Cadmium (d) 0.15 0.82 0.252 0.59 3.24 Cd -Trout strea 0.15 „ 0.51 0.252 0.59 2.01 Chromium III (d)(h) 24 183 0.202 117.73 905.0 Chromium VI d 11 16 1.000 11.00 16.0 Chromium, Total t N/A N/A Copper (d)(h) 2.7 3.6 0.348 7.86 10.47 Lead (d)(h) 0.54 14 0.1 2.94 75.4 Nickel (d)(h) 16 145 0._432 37.23 335.21 1-1- WS streams (t) Silver (d)(h,acute) 0.06 0.30 1.000 0.06 0.30 anc (d)(h) 36 36 0.288 126.73 125.71 Be Ilium 000 Arsenic (d) 1.000 340 (d) = dissolved metal standard. See 15A NCAC 02B.0211 for more information. (h) = hardness -dependent dissolved metal standard. See 15A NCAC 02B.0211 for more information. (t) = based upon measurement of total recoveable metal. See 15A NCAC 02B.0211 for more information. The Human Health standard for Nickel in Water Supply Streams is 25 mg/L which is Total Recoverable metal standard. The Human Health standard for Arsenic is 10 µg/L which is Total Recoverable metal standard. Hardness Hardness Wastewater Wastewater Hardness summer summer 7010 1010 Flow Limit -Fixed Value- Chronic Acute Hardness Concentration Concentration Average 7O10(CFS) (MGD) MGD MGD (mg/L) (mg/L) (mg/L) Average (mg/L) (Chronic) (Acute) (mg/L) o.0000 0 ooao 0 000o z 3zn� to zs o0o z5 00o too.0000 t00.0o00 25 25