HomeMy WebLinkAboutNC0024228_Compliance Evaluation Inspection_201703281 " Water'Resources Environmental Quality March 28, 2017 Mr. Terry Houk, Director of Public Services City of High Point P.O. Box 230 High Point, NC 27261 SUBJECT: ' Compliance Evaluation Inspection (CEI) City of High Point - Westside WWTP NPDES Permit # NCO024228 Davidson County Dear Mr. Houk: ROY COOPER Governor MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director RECE"NOODWR APR 0 4 2017 WabrQua pe on A Compliance Evaluation Inspection was performed on the subject facility by Ms. April Norton on March 23, 2017 at 10:00 am. Mr. Michael Swan, Operator in Responsible Charge (ORC), and Mr. Tim Fitzgerald were present for the inspection. The inspection is comprised of an overall evaluation to document compliance and noncompliance of. facilities equipment, capability to meet effluent limits, and terms & conditions with the National Pollutant Discharge Elimination System. (NPDES) permit. Permit The NPDES permit became effective August 1, 2009 and expired on April 30, 2014. An Authorization to Construct (ATC) was issued on October 9, 2013. Authorization is granted for construction of modifications to the existing 6.2 million gallons per day (MGD). The authorization results in an increase in design capacity to 10 MGD, but the limits permitted capacity to 8.2 MGD. The following specific modifications have been granted: New Biological Nutrient Removal (BNR) system consisting of four parallel trains with total volumes of 0.50 MG anaerobic zone, 0.91 MG first stage anoxic zone, 4.95 MG aerobic zone, 1.48 MG second stage anoxic zone, 0.29 MG re= aeration zone, including fine bubble diffusers and 40 vertical mixers; new blower/NRCY building including two 6,074 inlet cubic feet per minute (ICFM) blowers, two 4,050 ICFM blowers, and four 6,944 gallons per minute (GPM) NRCY pumps; a new clarifier; two 3,550 GPM return activated sludge (RAS) pumps; a new process drain station including one 800 GPM pump, two 150 GPM non -potable water pumps; associated electrical and control/supervisory control and data acquisition (SCADA) work, site work, and yard piping in conformity with project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environmental Quality. }::�.' "fNotlaing C,ompares!:_ ._. State of North Carolina I Environmental Quality 450 West Hanes Mill Road, Suite 300 1 Winston-Salem, North Carolina 27105 336-776-9800 The construction is taking place in three phases: Phase one consisted of constructing a new preliminary treatment facility and odor control system; phase two included the addition of new sand filter construction, a new building and effluent pump, and new earthen berms for flood control. The final phase, phase three; involves replacing the current activated sludge system with a five phase BNR system. The estimated completion date for construction is October 2017. Instream monitoring requirements are waived if this facility is a member of the Yadkin -Pee Dee River Basin Association. If the facility ends. its membership in the Yadkin -Pee Dee River Association, instream monitoring requirements specified in the permit take effect. Whole effluent toxicity tests are conducted quarterly using Ceriodaphnia dubia. The Ceriodaphnia dubia test is assessed as a pass or fail test, and the November 2016 test assessed was reported as failing. This resulted in the issuance of a notice of .violation (NOV) by the Aquatic Toxicity ' Branch.. Record's & Reports Process controls and observations are recorded daily by shift personnel on log sheets. A log book is, also available documenting the ORCs site visitation. The Performance Annual Report (PAR) is current and available to the public. All records must be kept for 3 years and sludge for 5 years. All laboratory records must be kept for .5 years. Facility Site Review The facility is continuing to operate under the existing 6.2 MGD wastewater treatment plant flow capacity consisting of influent screw pumps, mechanical bar screen, aerated grit chambers, influent flow measurement, dual primary clarifiers, roughing filters, three aeration basins, dual secondary clarifiers,, tertiary filters, alum phosphorus removal _facilities, dissolved air floatation (DAF), and ultraviolet disinfection. Effluent/Receiving Waters The effluent to the Rich Fork Creek, which flows into the Yadkin -Pee Dee River Basin, Class C waters. Flow Measurement The NPDES permit requires continuous flow recording and an annual calibration. The flow measuring device was calibrated on October 19, 2016. The next annual calibration is due October 31, 2017. Self -Monitoring Program There were no.NPDES monthly monitoring violations. The only violation which occurred was due to toxicity in November 2016. Laboratory data verification was performed on April 2016 and November 2016 Discharge Monitoring Reports (DMRs). There were no errors noted. Laboratory State certified laboratory services are provided in-house. The lab was not evaluated at the time of inspection. Operations & Maintenance There appeared to be no O&M concerns at the time of the inspection. The facility operations and maintenance superintendent is Mr. Rick Riley. Sludge Handling/Disposal Sludge records were not evaluated at the time of this inspection. Compliance Status The compliance evaluation inspection is satisfactory. All action items from the previous inspection were completed and are acceptable. Thank you for your efforts. Should you have any questions concerning this report, please contact April Norton or me at (336) 776-9800. Sincerely, f �rslherri V Knight, PE, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ cc: Mike Swanson (electronic copy) Central Files WSRO Files United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires B-31-98 Section A: National Data System Coding (i.e.,. PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 I^I I 2 15 1 3 I NCo024228 I11 12 17/03/23 17 18 I I 19 I G 20I I 21111111 1111111 1I I I X 11 1111 1 111111 1111111 1I I I r6 Inspection Work Days Facility Self-Monitoring Evaluation Rating 137 QA Reserved-- 67 70 I, I 71 I„ I 72 N 73 174 75 80 _jj I-J LJ L1J Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10:OOAM 17/03/23 13/08/01 Westside WWTP Exit Time/Date Permit Expiration Date 1044 W Burton Rd 12:OOPM 17/03/23 14/04/30 Thomasville NC 27360 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Michael Frederick Swan/ORC/336-822-4782/ Name, Address of Responsible Officialrritle/Phone and Fax Number Contacted John Hodges,PO Box 230 High Point NC 27261//336-822-4730/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenance Records/Reports Self-Monitoring Program N Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date April Norton WSRO WQ//336-776-9800/ l t> n ure of Management Q A Reviewe Agency/Office/Phone and Fax Numbers Date 3 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type 1 31 NCO024228 I1 12 17/03/23 17 18 I Section D: Summary of Finding/Comments (Attach additionalsheetsof narrative and checklists as necessary) Page# Permit: NCO024228 Owner - Facility: WestsideWWfP Inspection Date: 03/23/2017 Inspection Type: Compliance Evaluation Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: Influent Samplina # Is composite sampling flow proportional? Is sample collected above side streams? Yes No NA NE ■ ❑ ❑ ❑ M ❑ ❑ ❑ ■ ❑ 1:11:1 M ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE M ❑ ❑ ❑ M ❑ ❑ ❑ ■ ❑ ❑ ❑ .M ❑ ❑ ❑ ■ ❑ ❑ ❑ M M ❑ ❑ ❑ ■ ❑ ❑ ❑ M ❑ ❑ ❑ M ❑ ❑ ❑ ■ ❑ ❑ ❑ M ❑ ❑ ❑ M ❑ ❑ ❑ M ❑ ❑ ❑ Yes No NA NE M ❑ ❑ ❑ Page# 3 EN Permit: NCO024228 Owner -Facility: WestsideWWTP Yes No NA NE Is composite sampling flow proportional? 0 ❑ Inspection Date: 03/23/2017 Inspection Type: Compliance Evaluation ❑ Is sample collected below all treatment units? M ❑ Influent Sampling Yes No NA NE Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? M ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Is sampling performed according to the permit? N ❑ ❑ ❑ Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? 0 ❑ ❑ ❑ Is sample collected below all treatment units? M ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees N ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type 0 ❑ ❑ ❑ representative)? Comment: Flow Measurement - Influent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? M ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ❑ 0 Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean. with acceptable housekeeping? . N ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable 0 ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Equalization Basins Yes No NA NE Is the basin aerated? ❑ ❑ ❑ Is the basin free of bypass lines or structures to the natural environment? M ❑ ❑ ❑ Page# 4 Permit: NC0024228 Owner - Facility: Westside VWVTP Type of bar screen N ❑ Inspection Date: 03/23/2017 Inspection Type: Compliance Evaluation a.Manual ❑ ❑ Equalization Basins Yes No NA NE Is the basin free of excessive grease? 0 ❑ 1-11:1 ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? 0 ❑ ❑ ❑ Are float controls operable? M ❑ ❑ ❑ Are audible and visual alarms operable? ❑ ❑ ❑ M # Is basin size/volume adequate? 0 ❑ ❑ ❑ Comment: Bar Screens Yes No NA NE Type of bar screen N ❑ ❑ ❑ a.Manual ❑ ❑ ❑ ❑ b.Mechanical 0 ❑ ❑ ❑ Are the bars adequately screening debris? M ❑ ❑ ❑ Is the screen free of excessive debris? N 01111 ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Is the unit in good condition? M ❑ ❑ ❑ Comment: Grit Removal Yes No NA NE Type of grit removal N ❑ ❑ ❑ a.Manual ❑ ❑ ❑ ❑ b.Mechanical 0 ❑ ❑ ❑ Is the grit free of excessive organic matter? N ❑ ❑ ❑ Is the grit free of excessive odor? 0 ❑ ❑ ❑ # Is disposal of grit in compliance? 0 ❑ ❑ ❑ Comment: Primary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? N ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ❑ ❑ ❑ Are weirs level? 0 ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? M ❑ ❑ ❑ Page# 5 Permit: NCO024228 Owner - Facility: Westside WWTP Mode of operation Plug flow ❑ Inspection Date: 03/23/2017 Inspection Type: Compliance Evaluation Diffused ❑ ❑ Primary Clarifier Yes No NA NE Is scum removal adequate? E ❑ ❑ ❑ Is the site free of excessive floating sludge? Are the diffusers operational? ❑ ❑ ❑ Is the drive unit operational? 0 ❑ ❑ ❑ Is the sludge blanket level acceptable? E ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately '/e of the sidewall depth) N ❑ ❑ ❑ Comment: Aeration Basins Yes No NA NE Mode of operation Plug flow ❑ ❑ Type of aeration system Diffused ❑ ❑ Is the basin free of dead spots? 0 ❑ ❑ ❑ Are surface aerators and mixers operational? 0 ❑ ❑ ❑ Are the diffusers operational? N ❑ ❑ ❑ Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? N ❑ ❑ ❑ Is the DO level acceptable? N ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) E ❑ ❑ ❑ Comment: Nutrient Removal Yes No NA NE # Is total nitrogen removal required? ❑ ❑ ❑ # Is total phosphorous removal required? E ❑ ❑ ❑ Type Biological Are backup pumps available? # Is chemical feed required to sustain process? ❑ ❑ E ❑ Is nutrient removal process operating properly? 0 ❑ ❑ ❑ Comment: Chemical Feed Yes No NA NE Is containment adequate? ❑ ❑ ❑ Is storage adequate? N ❑ ❑ ❑ Are backup pumps available? ❑ ❑ ❑ Is the site free of excessive leaking? N ❑ ❑ ❑ Comment: Page# 6 A ti Permit: NC0024228 Owner - Facility: Westside WWTP Inspection Date: 03/23/2017 Inspection Type: compliance Evaluation Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? N ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? M ❑ ❑ ❑ Are weirs level? M ❑ ❑ ❑ Is the site free of weir blockage? N ❑ ❑ ❑ Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ Is scum removal adequate? 0 ❑ ❑ ❑ Is the site free of excessive floating sludge? M ❑ ❑ ❑ Is the drive unit operational? 0 ❑ ❑, ❑ Is the return rate acceptable (low turbulence)? 0 ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? N ❑ . ❑ ❑ Is the sludge blanket'level acceptable? (Approximately %< of the sidewall depth) 0 ❑ ❑ ❑ Comment: Filtration (High Rate Tertiary) Yes No NA NE Type of operation: 0 ❑ ❑ ❑ Is the filter media present? 0 ❑ ❑ ❑ Is the filter surface free of clogging? M ❑ ❑ ❑ Is the filter free of growth? N ❑ ❑ ❑ Is the air scour operational? ❑ ❑ M ❑ Is the scouring acceptable? ❑ ❑ M ❑ Is the clear well free of excessive solids and filter media? ❑ ❑ ❑ Comment: Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? 0 ❑ ❑ ❑ Are UV bulbs clean? 0 ❑ ❑ ❑ Is UV intensity adequate? ❑ ❑ ❑ Is transmittance at or above designed level? ❑ ❑ ❑ Is there a backup system on site? ❑ ❑ ❑ Is effluent clear and free of solids? ❑ ❑ ❑ Comment: Pump Station - Effluent Yes No NA NE Page# 7 r Permit: NG0024228 Owner - Facility: Westside wWTP Are pumps in place? N ❑ Inspection Date: 03/23/2017 Inspection Type: Compliance Evaluation . Are pumps operational? N ❑ Pump Station - Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures? 0 . ❑ ❑ ❑ Are all pumps present? E ❑ ❑ ❑ Are all pumps operable? E ❑ ❑ ❑ Are float controls operable? ❑ ❑ 0 ❑ Is SCADA telemetry available and operational? 0 ❑ ❑ ❑ Is audible and visual alarm available and operational? ❑ ❑ ❑ 0 Comment: Pumps -RAS -WAS Yes No NA NE Are pumps in place? N ❑ ❑ ❑ Are pumps operational? N ❑ ❑ ❑ Are there adequate spare parts and supplies on site? 0 ❑ ❑ ❑ Comment: Standby Power Yes No NA NE Is automatically activated standby power available? 0 ❑ ❑ ❑ Is the generator tested by interrupting primary power source? 0 ❑ ❑ ❑ Is the generator tested under load? 0 ❑ ❑ ❑ Was generator tested & operational during the inspection? ❑ M ❑ ❑ Do the generator(s) have adequate capacity to operate the entire wastewater site? 0 ❑ ❑ ❑ Is there an emergency agreement with a fuel vendor for extended run on back-up power? E ❑ ❑ ❑ Is the generator fuel level monitored? ❑ ❑ ❑ Comment: Generator was not tested during site visit. Solids Handling Equipment Yes No NA NE Is the equipment operational? 0 ❑ ❑ ❑ Is the chemical feed equipment operational? 0 ❑ ❑ ❑ Is storage adequate? 0 ❑ ❑ ❑ Is the site free of high level of solids in filtrate from filter presses or vacuum filters? 0 ❑ ❑ ❑ Is the site free of sludge buildup on belts and/or rollers of filter press? 0 ❑ ❑ ❑ Is the site free of excessive moisture in belt filter press sludge cake? ❑ ❑ ❑ The facility has an approved sludge management plan? ❑ ❑ ❑ Comment: Page# 8 w Permit: NC0024228 Owner -Facility: WestsideWWTP Inspection Date: 03/23/2017 Inspection Type: Compliance Evaluation Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? N ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ M ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? N ❑ ❑ ❑ Comment: A small amount of foam was present. Page# 9