Loading...
HomeMy WebLinkAboutNC0021865_NOV2017PC0117_20170217 ROY COOPER Governor e,s,. ;_¢ MIC.HAEL S. REGAN 4 Seavtary Wate y Resortes S. JAY ZIMMERMAN 6PtafRd}lfl4 NTAL QUALrTY Uftc1COt' Certified Mail # 7013 2630 0002 1133 7577 Return Receipt Requested '`� (a� ';; U1 f 1141J1!;(1) 1..1 February 21, 2017 . 1.'13 %83 ?ri181, l'7 Patricia Garrell ,. Atzs,., tartn Town of Chadbourn 602 N Brown St Chadbourn, NC 28431 , SUBJECT: NOTICE OF VIOLATION &INTENT TO ASSESS CIVIL PENALTY Tracking Number: NOV-2017-PC-0117 Permit No. NC0021865 Chadbourn WWTP Columbus County Dear Permittee: The North Carolina Division of Water Resources conducted a site inspection of the Chadbourn WWTP on February 8, 2017. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0021865. A summary of the findings and comments noted during the inspection are provided in the enclosed copy of the inspection report. The Reconnaissance inspection was conducted by Division of Water Resources staff from the Wilmington Regional Office. The following violation(s) were noted during the inspection: Inspection Area Description of Violation Effluent Sampling Facility is using a portable sampler to sample from manhole where pond's flow ties to outfall line, but of course not flow proportional. Regional Office not notified. Filtration (High Rate Tertiary) Filter off-line; Regional Office not notified. Aeration Basins The center aerator in the newer, upper basin was missing with the motor sent off for repair; Regional Office not notified. Secondary Clarifier The original clarifier was off-line; Regional Office not notified. The online unit's skimmer is missing its rubber seals on each end allowing a significant amount of the captured floatables to bypass around it and not get removed. Standby Power Unit down; Regional Office not notified. State of North Carolina I Environmental Quality I Water Resources 127 Cardinal Drive Extension,Wilmington,North Carolina 28405 910-796-7215 Inspection Area Description of Violation Lagoons Using in unapproved manner and discharging from them; Regional Office not notified. Disinfection-Gas Using old system; Regional Office not notified. A Notice of Violation/Intent to Issue Civil Penalty is being issued for the noted violation of North Carolina General Statute (G.S.) 143-215.1 and the facility's NPDES Permit. Pursuant to G.S. 143-215.6A, a civil penalty of not more than twenty-five thousand dollars ($25,000.00) may be assessed against any person who violates or fails to act in accordance with the terms, conditions, or requirements of any permit issued pursuant to G.S. 143-215.1. If you wish to provide additional information regarding the noted violation, request technical assistance, or discuss overall compliance please respond in writing within ten (10) business days after receipt of this Notice. A review of your response will be considered along with any information provided on the submitted Discharge Monitoring Report(s). You will then be notified of any civil penalties that may be assessed regarding the violations. If no response is received in this Office within the 10-day period, a civil penalty assessment may be prepared. Remedial actions should have already been taken to correct this problem and prevent further occurrences in the future. The Division of Water Resources may pursue enforcement action for this and any additional violations of State law. If the violations are of a continuing nature, not related to operation and/or maintenance problems, and you anticipate remedial construction activities, then you may wish to consider applying for a Special Order by Consent. Reminder: Pursuant to Permit Condition 6 in Section E, the Permittee is required to verbally notify the Regional Office as soon as possible, not to exceed 24 hours, from first knowledge of any non-compliance at the facility including limit violations, bypasses of, or failure of a treatment unit. A written report may be required within 5 days if directed by Division staff. Prior notice should be given for anticipated or potential problems due to planned maintenance activities, taking units off-line, etc. If you should have any questions, please do not hesitate to contact Dean Hunkele with the Water Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215. Sincerer • Morella—Si Wee -King, Assistant Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Wilmington Regional Office - Enforcement File NPDES Compliance/Enforcement Unit - Enforcement File • Central Files, WQS State of North Carolina I Environmental Quality I Water Resources 127 Cardinal Drive Extension,Wilmington,North Carolina 28405 910-796-7215 United States Environmental Protection Agency Form Approved. EPA Washington,D.C.20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A:National Data System Coding(i.e.,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 15 I 3 I N00021865 111 12 1 17/02/08 117 18I ]I 19 I S I 201 21I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I II I I I I I I6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA Reserved 67 I 70 LI I 71 ID I 72 I N I 731 1 174 751 1 1 1 1 1 1 180 Section B:Facility Data Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 10:15AM 17/02/08 15/01/01 Chadbourn WWTP 5275 Chadbourn Hwy Exit Time/Date Permit Expiration Date 04:15PM 17/02/08 19/08/31 Chadbourn NC 28431 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /1/ John Brian Stephens/ORC/910-643-2256/ Patrice E Garrell//910-654-4148/ Steven Price/Director Public Works// Steven Price/Director Public Works/910-654-4148/9106544148 Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Steven Price,602 N Brown St Chadbourn NC 28431/Public Works Director/910-654-4148/ Yes Section C:Areas Evaluated During Inspection(Check only those areas evaluated) • Flow Measurement ® Operations&Maintenance 0 Self-Monitoring Program ® Sludge Handling Disposal ® Facility Site Review Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) • Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Dean Hunkele- WIRO WQ//910-796-7215/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date Morella Sanchez-King WIRD WQ//910-796-7218/ EPA Form 3560-3(Rev 9-94)Previous editions are obsolete. Page# 1 NPDES yr/mo/day Inspection Type (Cont.) 31 NC0021865 I11 121 17/02/08 1 17 18 [ j Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) This visit was a follow-up after our regional staff consultant visited the facility the previous week when asked to go meet with the new operator that started January 1st to discuss the facility's operation probably in connection with the findings that day and covered in this report. This visit had several Town officials and their upgrade consulting team present, but not the new contract operator. The facility has lots of current issues all that were not reported to the regional office as they should have and are discussed in detail within the report. To complicate the situation, the facility is getting ready to start construction to add or replace treatment units or equipment starting in May or June based on approval granted in July 2016. This will be the first upgrade of the facility since it was hydraulically doubled in size in 1998-99. A Notice of Violation with Intent to Assess is being sent based on these findings and lack of notification. Following this visit and discussions onsite the following actions were required by the regional office via email notification on 2-9-17: 1. Effective next week, we are requiring 5x/week Fecal and TRC monitoring until further notice. No other increases at this time. 2. Please advise when polymer is in use. We would expect in to be in place by March 6th. • - 3. Please advise when flow meter and proportional sampling is in place. We would expect this to be in place and use by the 20th. 4. Please advise about back-up power ASAP, but by end of the month with timetable to implement. During the upgrades and after the new filters are online, any use of the pond will require same sampling as normal route with an increased fecal &TRC most likely and maybe more depending on what is being discharged to the ponds. That data will need to be filed here locally using the old DMR forms as we do not want to amend the permit/database for a 2nd outfall to file via e-DMR. Your reported effluent flow would additive. Lastly, the MLSS looked very thin in both basins and especially in the upper basin with the aerator down. Once that is back in use (I would hope over the weekend), you need to start tracking MLSS using the Royce portable TSS meter on-site and calibrate a reading for each using a MLSS sample sent to the lab from each. Calibration should be done every 4-6 months. • • Page# 2 Permit: NC0021865 Owner-Facility: Chadbourn WWTP Inspection Date: 02/08/2017 Inspection Type: Reconnaissance Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? ❑ ❑ ❑ Is the screen free of excessive debris? ❑ ❑ ON Is disposal of screening in compliance? ❑ ❑ ❑ Is the unit in good condition? ❑ ❑ 0111 Comment: The facility had removed the automatic inclined screening unit at some point and the regional office was not aware'of it. The planned upgrades at the facility include replacement of this unit. Grit Removal Yes No NA NE Type of grit removal a.Manual 0 b.Mechanical Is the grit free of excessive organic matter? ❑ ❑ E ❑ Is the grit free of excessive odor? ❑ ❑ ® ❑ # Is disposal of grit in compliance? ❑ ❑ ® ❑ Comment: The unit installed lust prior to entering the aeration basins was off-line and apparently has been for some time, but regional office was not aware of it. The planned upgrades at the facility include replacement of this unit. Hopefully new unit will be installed prior to the influent pumps to minimize pump degradation and settling of material in the wetwell. Aeration Basins Yes No NA NE Mode of operation Ext.Air Type of aeration system Surface Is the basin free of dead spots? ❑ ® ❑ ❑ Are surface aerators and mixers operational? 01100 Are the diffusers operational? ❑ ❑ ® ❑ Is the foam the proper color for the treatment process? ❑ ® ❑ ❑ Does the foam cover less than 25%of the basin's surface? 1110 ❑ ❑ Is the DO level acceptable? ❑ ❑ 01111 Is the DO level acceptable?(1.0 to 3.0 mg/I) ❑ ❑ ❑ • Page# 3 Permit: NC0021865 Owner-Facility: Chadbourn WWTP Inspection Date: 02/08/2017 Inspection Type: Reconnaissance - Aeration Basins Yes No NA NE Comment: The center aerator in the newer, upper basin was missing with the motor sent off for repair. The regional office was not made aware of this fact as the last report of aerator failure was from late June 2016 when one was lost in each basin resulting in limit violations. The mixed liquor appeared very thin so either it has settled in the center area with the missing aerator or it has been overwasted. The lower basin also appeared to be thinner than expected. MLSS should be monitored in each basin and prior& after wasting. Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 7'1 El ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ESI ❑ El El Are weirs level? El El El Is the site free of weir blockage? El El ❑ ❑ Is the site free of evidence of short-circuiting? %F.. El El ❑ Is scum removal adequate? El ® ❑ ❑ Is the site free of excessive floating sludge? h., ❑ El ❑ Is the drive unit operational? ® ❑ El El Is the-return rate acceptable(low turbulence)? ® ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? ® ❑ El El Is the sludge blanket level acceptable?(Approximately'A of the sidewall depth) El 0 El 131 Comment: The original clarifier was off-line and had apparently been so since before the beginning of 2017; replacement parts are being fabricated and should be ready in about a month. Regional office was not notifed of this failure. Flow from both aeration basins are using the newer clarifier. Effluent was very cloudy with visibility of less than 6 inches. The online unit's skimmer is missing its rubber seals on each end allowing a signifciant amount of the captured floatabtes to bypass around it and not get removed. Use of polymer was recommended while other clarifier is offline. Aerobic Digester Yes No NA NE • Is the capacity adequate? El El ❑ Is the mixing adequate? ❑ El El 1111 Is the site free of excessive foaming in the tank? ❑ El El # Is the odor acceptable? ❑ ❑ ❑ # Is tankage available for properly waste sludge? ❑ Si ❑ ❑ • Comment: The volume of these units were nbt inspected on this day, but consultant indicated they were • both full with no room to dewater the previous week. Town confirms that no sludge has been hauled from the facility since some time in 2015. However, they are making arrangements to have McGill dewater and haul it to their composting facility, but have yet to sample it as required by McGill to proceed. Apparently, they will begin using them in lieu of their own permit to dispose of it based on economic cost and staff evaluation. Page# 4 Permit: NC0021865 Owner-Facility: Chadbourn WWTP Inspection Date: 02/08/2017 Inspection Type: Reconnaissance Aerobic Digester Yes No NA NE Filtration (High Rate Tertiary) Yes No NA NE Type of operation: Down flow Is the filter media present? ❑ ❑ ® ❑ Is the filter surface free of clogging? ❑ ❑ RI ❑ Is the filter free of growth? 00010 Is the air scour operational? ❑ ❑ ® 0 Is the scouring acceptable? ❑ ❑ B ❑ Is the clear well free of excessive solids and filter media? 0 ❑ ± ❑ Comment: The traveling bridge filter was off-line due to piping failures below the media bed. The unit has been off-line for about a month. Once again the regional office was not notified. • Lagoons Yes No NA NE Type of lagoons? Facultative #Number of lagoons in operation at time of visit? 2 Are lagoons operated in? Parallel # Is a re-circulation line present? ❑ ❑ ® ❑ Is lagoon free of excessive floating materials? ® ❑ ❑ ❑ #Are baffles between ponds or effluent baffles adjustable? 0 ❑ ® 0 Are dike slopes clear of woody vegetation? ® ❑ ❑ ❑ Are weeds controlled around the edge of the lagoon? ® ❑ ❑ ❑ Are dikes free of seepage? ❑ ❑ 0 III Are dikes free of erosion? ❑ ❑ ❑ Are dikes free of burrowing animals? ❑ ❑ ❑ MI #Has the sludge blanket in the lagoon(s)been measured periodically in multiple ❑ 0 ® ❑ locations? #If excessive algae is present, has barley straw been used to help control the growth? ❑ ❑ ® ❑ Is the lagoon surface free of weeds? ® ❑ ❑ ❑ Is the lagoon free of short circuiting? ❑ ❑ MI ❑ Page# 5 Permit: NC0021865 Owner-Facility: Chadbourn WWTP Inspection Date: 02/08/2017 Inspection Type: Reconnaissance , Lagoons Yes No NA NE Comment:. Flow has been diverted to the two old emergency ponds following the filter failure and are now discharging from them through the old outfall line without notifying the regional office. The polishing ponds had been removed from the permit after the filter was added during hydraulic expansion of the facility in 1998-99, but were put back into the permit in the 2014 renewal after it was discovered they were using them when flows to the filter exceeded its capability and was being discharged without proper sampling and perhaps disinfection. However, use now requires regional office notification and requires its return for treatment and discharge through the officially permitted structures and outfall. Disinfection-Gas Yes No NA NE Are cylinders secured adequately? ❑ ❑ ❑ Are cylinders protected from direct sunlight? ❑ ❑ ❑ ,-; Is there adequate reserve supply of disinfectant? 00012 Is the level of chlorine residual acceptable? 000EI Is the contact chamber free of growth, or sludge buildup? ❑ ❑ ❑ E Is there chlorine residual prior to de-chlorination? 00011 Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No. 7782-50-5)? 000111 If yes,then is there a Risk Management Plan on site? ❑ ❑ ❑ Z! If yes,then what is the EPA twelve digit ID Number? (1000- - If yes,then when was the RMP last updated? Comment: The facility has placed its old disinfection system back online at the emergency ponds and using its old contact chamber. The regional office was not notifed of this. De-chlorination Yes No NA NE Type of system? Gas Is the feed ratio proportional to chlorine amount(1 to 1)? 00011 Is storage appropriate for cylinders? 00011 #Is de-chlorination substance stored away from chlorine containers? 00011 Comment: Are the tablets the proper size and type? ❑ ❑ E ❑ Are tablet de-chlorinators operational? ❑ ❑ ■ ❑ Number of tubes in use? Comment: The facility is introducing this into a manhole from the ponds and prior to its connection on the outfall line. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ® ❑ ❑ Page# 6 Permit: NC0021865 Owner-Facility: Chadbourn WWTP Inspection Date: 02/08/2017 Inspection Type: Reconnaissance Effluent Sampling Yes No NA NE Is sample collected below all treatment units? 41 ❑ ❑ 0 Is proper volume collected? 0 0 ❑ N Is the tubing clean? 0 0 0 111 #Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees 0 ❑ 0 Celsius)? Is the facility sampling performed as required by the permit(frequency, sampling type 0 0 0 El representative)? Comment: Facility is using a portable sampler to sample from manhole where pond's flow ties to outfall line. but of course not flow proportional. Standby Power Yes No NA NE Is automatically activated standby power available? IN ❑ ❑ ❑ Is the generator tested by interrupting primary power source? ❑ ❑ ❑ Is the generator tested under load? ❑ ❑ ® 0 Was generator tested &operational during the inspection? ❑ ❑ ® ❑ Do the generator(s)have adequate capacity to operate the entire wastewater site? CI ❑ ❑ ❑ Is there an emergency agreement with a fuel vendor for extended run on back-up power? ❑ ❑ ❑ II Is the generator fuel level monitored? ❑ ❑ ❑ le Comment: Staff was informed that the current generator has a blown head gasket which allows water to mix with the oil. While it may operate following loss of commercial power, how long before the engine seizes from oil contamination is unknown. The Town had rented a portable generator prior to Hurricane Matthew to cover them for the storm, but it was returned afterwards. The regional office was again not notified of this issue. At least the • facility is now monitored for power loss or influent pump station failure through an auto-dialer installed several years following its failure and the resulting SSO in town from the surcharged sewer system since staff had no idea power was out. Upgrade includes a new generator. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ❑ ❑ ❑ ■ Does the facility analyze process control parameters,for ex: MLSS, MCRT, Settleable ❑ ❑ OH Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Town was instructed to start monitoring MLSS once the aerators were back online. Doubtful much process control was being done otherwise. Flow Measurement - Effluent Yes No NA NE #Is flow meter used for reporting? ® ❑ 0 ❑ Is flow meter calibrated annually? ❑ ❑ ❑ Ell Page# 7 Permit: NC0021865 Owner-Facility: Chadbourn WWTP Inspection Date: 02/08/2017 Inspection Type: Reconnaissance Flow Measurement - Effluent Yes No NA NE Is the flow meter operational? ❑ ❑ ® ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ 0 El El Comment: The effluent flow is not being measured nor recorded since it is being discharged from the ponds versus the proper location which has flow measurement following chlorination. They were using the old influent flow meter that only measures flow to the original aeration basin assuming an even split and also has RAS entry. The town does not have influent measurement due to facility layout and depth of the incoming gravity sewer line. No idea when this meter was last calibrated. • • • • • • • Page# 8