Loading...
HomeMy WebLinkAboutNC0025721_Authorization to Construct_20170103 1\1rfl �tL� ,\(�.i_O��7Z ROY COOPER ;,. `� l Governor S. JAY ZIMMERMAN Water Resources Director ENVIRONMENTAL QUALITY January 3,2017 Mayor Julia M. Meacham • Town of Weldon 109 Washington Avenue • • Weldon,North Carolina 27890 SUBJECT: Authorization to Construct A to C No. 025721A03 Town of Weldon ° Town of Weldon WWTP Dear Mayor Meacham: A letter of request for an Authorization to Construct was received November 29,2016,by the Division of Water Resources (Division), and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of modifications to the existing 1.2 MGD Town of Weldon WWTP, with discharge of treated wastewater into the Roanoke River in the Roanoke River Basin. This authorization results in no increase in design or permitted capacity and is awarded for the construction of the following specific modifications: Replacement of the existing gas-based chlorination and dechlorination systems with liquid- based systems consisting of two (2) enclosed double wall 140 gallon chemical tanks and two(2)25.8 GPH 3/8 HP chemical feed pumps with manual and analog control,compatible with sodium hypochlorite solution,piping,and other controls;two(2)enclosed double wall 140 gallon chemical tanks and two(2)25.8.GPH 3/8 HP chemical feed pumps with manual • and analog control, compatible with calcium thiosulfate solution, piping, and other controls; repurpose three (3) existing yard hydrants to use internal reuse water; in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environmental Quality. This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No.NC0025721 issued effective August 1,2012,and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No.NC0025721. The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the Division. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may State of North Carolina I Environmental Quality I Water Resources 1617 Mail service Center I Raleigh,North Carolina 27699-1617 Location:512 N.Salisbury St.Raleigh,North Carolina 27604,Archdale Building 9th Floor Phone:919 807 6300/Fax:919 807 9489 u Mayor Julia M.Meacham January 3,2017 Page 2 of 3 be required by the Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Raleigh Regional Office,telephone number(919)791 -4200, shall be notified at least forty-eight(48)hours in advance of operation of the installed facilities so that an on site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct and the approved plans and specifications. Mail the Certification to: Division of Water Resources, WQ Permitting Section—NPDES, 1617 Mail Service Center, Raleigh,NC 27699-1617. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of T15A:8G.0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III and IV facility at least daily, excluding weekends and holidays, must properly manage the facility, must document daily operation and maintenance of the facility, and must comply with all other conditions of Tl5A:8G.0202. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. During the construction of the proposed additions/modifications, the permittee shall continue to properly maintain and operate the existing wastewater treatment facilities at all times; and in such a manner, as necessary to comply with the effluent limits specified in the NPDES Permit. You are reminded that it is mandatory for the project to be constructed in accordance with the North Carolina Sedimentation Pollution Control Act,and when applicable,the North Carolina Dam Safety Act. In addition, the specifications must clearly state what the contractor's responsibilities shall be in complying with these Acts. Prior to entering into any contract(s) for construction,the recipient must have obtained all applicable permits from the State. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. Mayor Julia M.Meacham January 3,2017 Page 3 of 3 The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. If you have any questions or need additional information, please contact Ron Berry at telephone number(919) 807-6396. Sincerely, ROV r , S. Jay mmerman Director, Division of Water Resources cc: W. Landon Younce, P.E. Green Engineering, PLLC P. O. Box 609 Wilson,NC 27893 DWR/Raleigh Regional Office, Water Quality Programs Central Files NPDES File Without Engineer's Certificate attached: Halifax County Health Department Town of Weldon Town of Weldon WWTP Authorization to Construct No. 025721A03 Issued January 3,2017 Engineer's Certification I, , as a duly registered Professional Engineer in the State of North Carolina,having been authorized to observe(periodically/weekly/full time)the construction of the modifications and improvements to the Town of Weldon Wastewater Treatment Plant, located in Halifax County,hereby state that,to the best of my abilities, due care and diligence was used in the observation of the following construction: Replacement of the existing gas-based chlorination and dechlorination systems with liquid-based systems consisting of two(2)enclosed double wall 140 gallon chemical tanks and two (2) 25.8 GPH 3/8 HP chemical feed pumps with manual and analog control, compatible with sodium hypochlorite solution, piping, and other controls; two (2), enclosed double wall 140 gallon chemical tanks and two (2) 25.8 GPH 3/8 HP chemical feed pumps with manual and analog control,compatible with calcium thiosulfate solution, piping,and other controls;repurpose three(3)existing yard hydrants to use internal reuse . water; in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environmental Quality. I certify that the construction of the above referenced project was observed to be built within substantial compliance, intent and in conformity with all applicable regulations and statutes and the project plans,specifications,and other supporting documentation comprising the Authorization to Construct Permit Application package. Signature Registration No. Date SEAL Mail this Certification to: Attn: Ron Berry Complex Permitting Unit DEQ/DWR/Water Quality Programs 1617 Mail Service Center Raleigh,NC 27699-1617 . i