HomeMy WebLinkAbout20000615 Ver 2_More Info Letter_20080703AN ATFiQQG Michael F. Easley, Governor
William G. Ross Jr., Secretary
r- North Carolina Department of Environment and Natural Resources
`C Coleen H. Sullins, Director
Division of Water Quality
July 3, 2008
DWQ Project # 00-0615, Ver. 2
Orange County
CERTIFIED MAIL: RETURN RECEIPT REQUESTED
Mr. John Link, Jr.
LinkBros, LLC
4720 Rapids Lane
Durham, NC 27705
Subject Property: Pleasant Green Woods Phase III
Ut to Eno River [030401, 27-2-(19), WSIV, NSW]
REQUEST FOR MORE INFORMATION
Dear Mr. Link:
On April 25, 2008, the Division of Water Quality (DWQ) received your application dated March 23,
2008, with additional information received from you on April 29, 2008, to fill or otherwise impact 89
linear feet of intermittent stream and 4,748 square feet of Zone 1 Neuse River basin protected riparian
buffers and 2,804 square feet of Zone 2 Neuse River basin protected riparian buffers to construct the
residential subdivision at the site. On June 2, 2008, and June 6, 2008, the DWQ received additional
information from you, however, the DWQ has determined that your application remains incomplete
and/or provided inaccurate information as discussed below. The DWQ will require additional
information in order to process your application to impact protected wetlands and/or streams on the
subject property. Therefore, unless we receive five copies of the additional information requested below,
we will place this project on hold as incomplete until we receive this additional information. If we do not
receive the requested information, your project will be formally returned as incomplete. Please provide
the following information so that we may continue to review your project.
Additional Information Requested:
1. Please provide a completed Required Items Checklist with all required items attached for every
proposed level spreader.
2. Level spreader A is directing flow toward the roadway fill slope. Please relocate this level
spreader to a more appropriate location per Chapter 8 of the BMP Manual.
Plan Sheet SW601 indicates that the slopes in the filter strip exceed the allowable slope of 8
percent for the use of level spreaders. Please either relocate the level spreaders to a location
where the filter strip slopes are appropriate for level spreaders or provide a BMP or series of
BMPs that removal a minimum of 85 percent TSS and 30 percent TN from the stormwater
generated by this project. For each proposed BMP, please provide a completed BMP Supplement
Form, with all the required items. The BMP Supplement Forms are available at:
401 Oversight/Express Review Permitting Unit
1650 Mail Service Center, Raleigh, North Carolina 27699-1650
2321 Crabtree Boulevard, Suite 250, Raleigh, North Carolina 27604
Phone: 919-733-1786 / FAX 919-733-6893 /Internet: http://h2o.enr.state.nc.us/newetlands
None Carolina
lvatura!!y
An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper
LinkBros, LLC
Page 2 of 2
June 2, 2008
http://h2o.enr.state.nc.us/su/binp forms.htm. Please include both the Design Summary and the
Required Items Checklist along with all the required items listed therein.
4. Please show the locations of all additional stormwater discharge points on the plans. These
discharge points must achieve diffuse flow in accordance with Chapter 8 of the BMP Manual.
For example, it appears that stormwater would discharge to the stream via a conveyance between
lots 14 and 15. It appears likely that there would be at least one other discharge point for
roadway drainage on this project.
Per the requirements of the Neuse Riparian Buffer Rule, all stormwater drainage from this site
must be discharged through a correctly designed level spreader. Level spreader design
requirements are set forth in Chapter 8 of the North Carolina Stormwater BMP Manual, available
at: http://h2o.enr.state. nc. us/su/bmp forms.htm. Please provide one Level Spreader Supplement
Form for each proposed level spreader, available at: http://h2o.enr.state.nc.us/su/bmp forms.htm.
Make sure to include the Required Items checklist and all items listed therein.
Please submit this information within 30 calendar days of the date of this letter. If we do not receive this
requested information within 30. calendar days of the date of this letter, your project will be withdrawn
and you will need to reapply with a new application and a new fee.
This letter only addresses the application review and does not authorize any impacts to wetlands, waters
or protected buffers. Please be aware that any impacts requested within your application are not
authorized (at this time) by the DWQ. Please call Ms. Cyndi Karoly or Mr. Ian McMillan at 919-733-
1786 if you have any questions regarding or would like to set up a meeting to i cuss this matter.
S' erely,
n Cyndi Karoly, Supervisor
9 (/401 Oversight/Express Review Permitting Unit
CBK/ijm
cc: Lauren Witherspoon, DWQ Raleigh Regional Office
USACE Raleigh Regulatory Field Office
File Copy
Central Files
Summit Consulting Engineers, 1000 Corporate Drive, Suite 101, Hillsborough, NC 27278
Filename: 000615Ver2PleasantGreen WoodsPhaselil(Orange)On_Hold3
¦ Complete items 1, 2, and 3. Also complete
item 4 if Restricted Delivery is desired.
¦ Print your name and address on the reverse
so that we can return the card to you.
¦ Attach this card to the back of the mailpiece,
or on the front if space permits.
1. Article Addressed to:
Link Bros, LLC
Attn: Mr. John Link, Jr.
4720 Rapids Lane
Durham,NC 27705
DWQ# 00-0615-v2-Orange
f?diL4l»??-VW& &Vto 00LXi7JIB79I19zf:it'
A. Signature
? Agent
X ? Addressee
B. Rived t?y (Print/ed Nam C. Date of Delivery
D. Is delivery address different from item 1? ? Yes
If YES, enter delivery address below: ? No
A,#
3. Se ice Type,,
uertifiect-mai, S ss Mail
Registered`' Return Receipt for Merchandise
? Insured Mail C.O.D.
4. Restricted Delivery? (Extra Fee) ? Yes
2. Article Number
(Transfer from service /al 7007 2560 0001 1381 5884
UNITED STATP, k?,pZ1
T SER ; ??til ?a!_}W, ?;
• Sender: Please print your name, address, and ZIP+4 in this box •
NC DENR Division of Water
Qualitv
401 Oversight/Express Unit
2321 Crabtree Boulevard suite250
Raleigh,NC 27604
-F?+?+ I11fi?'llt'Ifll?l'llii?it?ll'1?11/I?1 ?'llll" II'1'1 f?itll/'?ll