HomeMy WebLinkAbout20110359 Ver 2_Compliance Evaluation Inspection_20170126Wetland Inspection Report
Project Num: 20110359 Version: 3 Status: Issued
Project Name: Village Point Drive "* Linked to Project Type: New Road/Highway
County: Forsyth Region: Winston-Salem
Location: Village Point Drive ** Linked to DWQ 09-0250 & DWQ 10-0315 ** (U-5551)
Latitude: +360 01' Longitude: -80° 23'37"
SW Plan Location
Site Owner Name The Village of Clemmons
Inspection Date: 1/26/2017
Reason for Inspection Routine
Inspection Type: Site Inspection (non -DOT)
Inspection Contact Person: Title: Phone:
On -Site Representative(s):
Primary Inspector: Sue L Homewood
Secondary Inspector(s):
Facility Compliance Status: ❑ Compliant M Not Compliant
Program Areas: 401 (includes isolated/non-404)
Question Areas:
0 Permit (401 WQC)
Inspection Summary:
Phone: 336-776-9694
page: 1
Site Number: 20110359
Inspection Date: 1/26/2017
Owner: Kirby, Larry W
Inspection Type: Site Inspection (non -DOT) Reason for Visit: Routine
Permit (401 WQC)
Yes No NA NE
Does the impact(s) match what was approved in the 401 WQC or non 404 permit?
❑
❑
❑
Are the culverts and/or filled areas installed properly?
❑ 0
❑
❑
Is the site compliant with additional conditions of the 401 WQC or non 404 permit?
❑ ❑
110
Comment: Culvert at site 2 did not appear to be buried and flow through culvert was very
shallow. Rock check dam
below culvert was not operating properly and turbid water was flowing around dam, through wetland area.
page: 2
Homewood, Sue
From: Homewood, Sue
Sent: Monday, January 30, 2017 9:16 AM
To: 'LKirby@clemmons.org'
Cc: 'Judy Cherry'; Gantt, Matt; 'Kelway Howard'; 'Gibby, Jean B SAW'
Subject: Village Point Dr.
Attachments: culvert closeup jpg; culvert not buried jpg; looking downstream in channel jpg; turbid water
going around rock check damjpgjpg
Mr. Kirby,
Last Thursday, January 26, 2017, Jean Gibby with the USACE and myself were conducting a site visit along the Clemmons Town
Center property. As you know, this property is adjacent to the Village Point Drive construction and we came across some
concerns within that project. The attached pictures show that the culvert in this location has not been installed in accordance
with the approvals issued by the USACE and DWR. Both the 404 NWP and the 401 WQC require culverts to be placed below the
stream bed by at least 20% of the culvert diameter. At the time the streams were flowing at high volume due to recent rain
events and yet the flow going through the culvert was very shallow. This will need to be analyzed and addressed/corrected. Since
the project is still under construction we may be able to avoid issuing a Notice of non-compliance if we can resolve the situation
quickly.
In addition, there is a check dam below this culvert that was not functioning on the day we were there. Water was flowing around
both sides of the check dam and the downstream channel was very turbid. I'm copying Matt Gantt on this email so that he may
see the photos and follow up with this as he deems necessary. We did not investigate the situation further.
Thanks,
Sue Homewood
Division of Water Resources, Winston Salem Regional Office
Department of Environmental Quality
336 776 9693 office
336 813 1863 mobile
Sue. Homewood@ncdenr.gov
450 W. Hanes Mill Rd, Suite 300
Winston Salem NC 27105
N�_
NothIng Compares_-.,_
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties.
t Kiri
4 f ,
Kj
A
1
�1 I 4L �. `
„aI' .a. '�f pr. ` � } j y��,�'”" "fir � � ♦ ..
I.
11
1
PF1. del
�� Ni i' •' 'wry i'Ur � - - � �l
IL 11
y J,
or
C
rIf.I It
Ali �J✓ �.y
24 J j' �_ ✓
't t fir{ , i - +fjtelp '" Ibl#$fes �dF
4 ��n� - • t Fr sar I � ;�f
q�� ggs
lryK ric+^ f11 � ��1 ��lZt �� •a
Rt
^^^ e
i�,i.._ r oa• jlS/
91
19 AIR
t I I y
Ilk
_ fiCi
F-`riiWayrF, ;1�-SPV'L^',. tai^.. F
/ .�,gt yii•rt �VQ�+-fes ..r . _V�.aa •.
1� 30
MX4+-l�_-
__ a
" C —T/ ..'�''��pJ�Fa.._ -4'x l -� f t ►
���� - / /�% ry�-'L.r ✓ l.xt . � -I .t _ : 1 LC ryl"' �•M � •'�(/y
-
(y
�'1�aIN
M;1lit
iVIA Z 'Fi!I�'
j
�.f�
KlTol
lsei I"Y•hIx �NNw
IF
C
I�l•� � I S yi q� a{ Y v x d -�o11
IV
S$
's_ y 1. yp
i