Loading...
HomeMy WebLinkAboutNC0023353_Compliance Evaluation Inspection_20160915WaterResources ENVIRONMENTAL QUALITY September 15, 2016 Timothy Fleming Frush Town of White Lake PO Box 7250 Elizabeth Town, NC 283377250 SUBJECT: Compliance Evaluation Inspection Town of White Lake White Lake WWTP Permit No: NCO023353 Bladen County Dear Mr Frush: PAT MCCRORY Governor DONALD R. VAN DER VAART Secretary S. JAY ZIMMERMAN Director REGEIVECINCDEOIDWR SEP 2 ® 2016 water Quality permitting Section Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on 8/29/2016. The Compliance Evaluation Inspection was conducted by Johnathan C. Watts, Environmental Specialist, of the Fayetteville Regional Office. The facility was found to be in Compliance with permit NC0023353. As part of the inspection, a tour of the plant was conducted. All observations are in Section D. Summary of Findings/Comments of this report. As a reminder, preservation of the Waters of the State can only be achieved through consistent NPDES Permit compliance. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 910-433-3322. cc: William E Stafford, ORC Central Files Fayetteville Files Sincerely, Johnathan C. Watts Environmental Specialist Division of Water Resources Water Quality Regional Operations Section Fayetteville Regional Office 225 Green Street, Suite 714, Fayetteville, North Carolina 28301-5095 Main Phone: 910-433-3300 \ Internet: hftp:/Avww.ncdenr.gov An Equal Opportunity\ Affirmative Action Employer— Made in part by Recycled Paper United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires B-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 15 I 3 I NCO023353 111 121 16/08/29 117 18 I C J 19 i i i 201 I 21111111111111111111111111111111111111111111 f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA -------Reserved-------- 67 70 i, i 71 L_] 72 I N I 73 I I 174 751 I I I 1 I 1 I80 I I LJ I I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10:OOAM 16/08/29 12/09/01 White Lake WWTP Exit Time/Date Permit Expiration Date 90 E William St 01-30PM 16/08/29 17/01/31 Elizabethtown NC 28337 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data William E Stafford/ORC/910-862-4800/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Timothy Fleming Frush,PO Box 7250 Elizabeth Town NC No 28 3 3772 5 0//91 0-862-4 80 0/91 086 28686 Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance N Records/Reports Self -Monitoring Program Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Johnathan C Watts FRO WQ//910-433-3300/ 1. qk Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date B inS H on RO WQ//910-433-3300 Ext.72E 9 /I s� G 41607 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type (Cont.) NCO023353 I11 12I 16/08/29 117 18 1,1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Enclosed you will find a copy of the Compliance Evaluation Inspection report for the routine inspection that was conducted on August 29, 2016 by Mark Brantley, Environmental Program Consultant and Johnathan Watts, Environmental Specialist of the Fayetteville Regional Office. The purpose of the inspection was to evaluate compliance with the requirements of the Wastewater General Permit NC0023353. As part of the inspection, a tour of the plant was conducted and weekly monitoring sample records were examined from March 2016 to April 2016. On the day of the inspection, this facility was found to be in compliance with the requirements of the permit. You are commended for your initiative and proactive approach for the documentation and on site monitoring. I appreciate the time and professional courtesy that you and Timothy Frush, Public Works Director, extended during the inspection. No additional response is necessary from your office concerning this report. If you have any questions, please feel free to contact me at (9 10) 433-3322. The White Lake WWTP, located at 90 East William St. Elizabethtown NC, produces discharge of treated effluent from a biological water pollution control treatment system, which consists of a Lagoon divided into 4 cells. All documentation records and log books appeared to be complete and current with provisions of the permit. All data appeared to correspond with DMR's. Effluent Flow Meter was Calibrated on May 26, 2016 and verification of the Chlorine meter calibration curve was performed on April 1, 2016. The Vortex Grit Chamber is currently defective and has been out of service since 2006, according to past inspections. It was determined that as a result of the algae bloom, there was green discoloration observed in the effluent, however barley straw is used to control growth. As stated from the previous inspection on August 8, 2013, "During the inspection of the chlorine contact chamber, a hole was noted in the baffle wall just before the effluent weir. This hole could allow some short circuiting." It is strongly recommended that a timeline and plan of action be submitted to perform repairs on chlorine contact chamber as baffles are critical for the efficient performance in improving the amount of chlorine contact time with fecal coliforms and possible contamination with pathogens. Restoring the chlorine contact chamber could reduce operation and maintenance activities and may ultimately increase reliability for achieving permit compliance. Based on conversations with Mr. Timothy Frush, progress towards these repairs are being made. Page# Permit: NCO023353 Owner -Facility white Lake WWTP Inspection Date. 08/29/2016 Inspection Type. Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? M ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ M ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new M ❑ ❑ ❑ application? M ❑ ❑ ❑ Is the facility as described in the permit? M ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ M ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? M ❑ ❑ ❑ Comment: Permit effective 09/01/2012. Permit expires 01/31/2017 Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? M ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? M ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? M ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? 0 ❑ ❑ ❑ (if the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ 0 ❑ on each shift? Is the ORC visitation log available and current? M ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? 0 ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? M ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? ❑ ❑ ❑ Page# 3 Permit: NCO023353 Owner -Facility. whiteLakewWTP Inspection Date, 08/29/2016 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? M ❑ ❑ ❑ Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? M ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ' ❑ ❑ ❑ ❑ Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? M ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? M ❑ ❑ ❑ Comment: Effluent Flow Meter was Calibrated on May 26, 2016 Bar Screens Yes No NA NE Type of bar screen 0 ❑ ❑ ❑ a.Manual 0 ❑ ❑ ❑ b.Mechanical ❑ ❑ ❑ Are the bars adequately screening debris? M ❑ ❑ ❑ Is the screen free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screening in compliance? N ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: Bar screen was repaired. Disinfection -Gas Yes No NA NE Are cylinders secured adequately? 0 ❑ ❑ ❑ Are cylinders protected from direct sunlight? 0 ❑ ❑ ❑ Is there adequate reserve supply of disinfectant? ❑ ❑ ❑ Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ N Page# 4 Permit: NCO023353 Owner -Facility: White Lake WWTP Inspection Date: 08/29/2016 Inspection Type: Compliance Evaluation Disinfection -Gas Yes No NA NE Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No. 7782-50-5)? E ❑ ❑ ❑ If yes, then is there a Risk Management Plan on site? E ❑ ❑ ❑ If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: Risk Management Plan is currently under revision. De -chlorination Yes No NA NE Type of system ? Gas ❑ ❑ ❑ Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ ❑ 0 Is storage appropriate for cylinders? 0 ❑ ❑ ❑ # Is de -chlorination substance stored away from chlorine containers? ❑ 0 ❑ ❑ Are the tablets the proper size and type? ❑ ❑ 0 ❑ Comment: Sulfur Dioxide and Chlorine tankes are stored under the same shelter. Are tablet de -chlorinators operational? ❑ ❑ 0 ❑ Number of tubes in use? Comment: StandbV Power Yes No NA NE Is automatically activated standby power available? 0 ❑ ❑ ❑ Is the generator tested by interrupting primary power source? 0 ❑ ❑ ❑ Is the generator tested under load? E ❑ ❑ ❑ Was generator tested & operational during the inspection? ❑ ❑ ❑ 0 Do the generator(s) have adequate capacity to operate the entire wastewater site? E ❑ ❑ ❑ Is there an emergency agreement with a fuel vendor for extended run on back-up power? N ❑ ❑ ❑ Is the generator fuel level monitored? 0 ❑ ❑ ❑ Comment: Lagoons Yes No NA NE Type of lagoons? Aerated # Number of lagoons in operation at time of visit? 1 Are lagoons operated in? Multicell # Is a re -circulation line present? ❑ 0 ❑ ❑ Is lagoon free of excessive floating materials? 0 ❑ ❑ ❑ Page# 5 Permit: NCO023353 Owner -Facility: white Lake wVViP Inspection Date. 08/29/2016 Inspection Type: Compliance Evaluation Yes No NA NE Is composite sampling flow proportional? 0 ❑ Lagoons Yes No NA NE # Are baffles between ponds or effluent baffles adjustable? ❑ N ❑ ❑ Are dike slopes clear of woody vegetation? 0 ❑ ❑ ❑ Are weeds controlled around the edge of the lagoon? 0 ❑ ❑ ❑ Are dikes free of seepage? 0 ❑ ❑ ❑ Are dikes free of erosion? ❑ ❑ ❑ ❑ Are dikes free of burrowing animals? 0 ❑ ❑ ❑ # Has the sludge blanket in the lagoon (s) been measured periodically in multiple M ❑ ❑ ❑ locations? # If excessive algae is present, has barley straw been used to help control the growth? M ❑ ❑ ❑ Is the lagoon surface free of weeds? 0 ❑ ❑ ❑ Is the lagoon free of short circuiting? N ❑ ❑ ❑ Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? 0 ❑ ❑ ❑ Is sample collected below all treatment units? 0 ❑ ,❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees N ❑ ❑ ❑ Celsius)? ❑ ❑ ❑ Is the facility sampling performed as required by the permit (frequency, sampling type 0 ❑ ❑ ❑ representative)? Comment: At the time of the inspection temperature of sampler was 5 degrees Celsius. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? ❑ ❑ ❑ # Is the facility using a contract lab? M ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees N ❑ ❑ ❑ Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ ❑ Comment: Oakton 150 is used to measure pH and Hach DR2700 for Chlorine. Enviro 1 is contracted for BOD and TSS analysis. Page# 6 Permit: NCO023353 Inspection Date: 08/29/2016 Influent Sampling # Is composite sampling flow proportional? Is sample collected above side streams? Is proper volume collected? Owner -Facility: White Lake WWTP Inspection Type: Compliance Evaluation Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is sampling performed according to the permit? Comment: Influent sampler was 2 degrees Celsius at the time of the inspection. Yes No NA NE ■ ❑ ❑ ❑ M ❑ ❑ ❑ M ❑ ❑ ❑ N ❑ ❑ ❑ ■ ❑ ❑ ❑ M ❑ ❑ ❑ Page# 7