Loading...
HomeMy WebLinkAbout20061617 Ver 2_More Info Letter_20080331~QF W'gTF9Q Michael F. Easley, Governor `(~ G William G. Ross Jr., Secretary ~ r North Carolina Department of Environment and Natural Resources p ~ Coleen H. Sullins, Director Division of Water Quality March 31, 2008 DWQ EXP No. 06-1617 Wake County CERTIFIED MAIL: RETURN RECEIPT REQUESTED Wake County Board of Education Wake County Public School System Attn: Mr. Mike Burriss 1429 Rock Quarry Road Suite 116 Raleigh, NC 27610 Project Name: E-34 (Wendell Elementary School) REQUEST FOR MORE INFORMATION On November 1, 2007 the Division of Water Quality (DWQ) issued a 401 Water Quality Certification to have specified amounts of impacts to state waters and riparian buffers for the purpose of constructing a Wendell Falls mixed use development, Wendell Falls Parkway and U.S. 64/264 interchange located in Wake County as described in your application dated September 26, 2006 and May 2, 2007, and all additional information received by DWQ on October 18, 2006, January 25, 2007, February 9, 2007, June 13, 2007, August 16, 2007, September 5, 2007 and September 12, 2007. In order to meet Conditions 25 and 26 of the 401 Certification for this project, a stormwater management plan was submitted to the Express Review Program of the DWQ on March 31, 2008. The DWQ has determined that your application will require additional information. Please provide the following information so that we may continue to review your project and prevent denial of your application as required by 15A NCAC 2H .0506: Additional Information Requested Bioretention Cells A & B: a. Please provide underdrain design calculations to show that the number of underdrain pipes provided is sufficient. Please also note that, the spacing of collection laterals shall be no greater than 10 feet center to center. (See Section 5.7 of the NC DWQ Stormwater BMP Manual). b. Please specify the following on the construction plans: i. The slope of the underdrain pipes (0.5% recommended). ii. The soil mix specifications including the source, composition, permeability and P- index. 2. Diffuse Flow Provisions: a. Condition 26 of your 401 Certification states that all stormwater shall be directed at non- erosive velocities through the protected stream buffers and will not re-concentrate before discharging into the stream. The outflow velocities of 5.68 ft/s and 6.16 ft/s from the proposed Bioretentions A and B respectively are considered erosive. The type of energy dissipation device provided only protects the outlet but will not insure that diffuse flow will be achieved. Please provide other mechanism to insure that non-erosive velocities are 401 Oversight I Express Review Permitting Unit 1650 Mail Service Center, Raleigh, North Carolina 27699-1650 2321 Crabtree Boulevard, Suite 250, Raleigh, North Carolina 27604 Phone: 919-733-17861 FAX 919-733-689311nternet: htto://h2o.enr.state.nc.us/ncwetlands No°e hCarolina ~atura!!r~ An Equal OpportunitylAffirmative Action Employer - 50% Recycledl10% Post Consumer Paper E-34 Wendell Elementary School Page 2 of 2 March 31, 2008 achieved prior to entering the stream buffers. A vertical circular structure with multiple outlets and rip-rap apron may be considered. Please respond within five (5) days of the date of this letter by sending two (2) copies of the above information in writing. The Express Review Program is a process that requires all parties to participate in a timely manner. This letter only addresses the application review and does not authorize any impacts to wetlands, waters or protected buffers. Please be aware that any impacts requested within your application are not authorized (at this time) by the DWQ. Please contact Joseph Gyamfi or Lia Myott at 919-733-1786 if you have any questions regarding, or would like to set up a meeting to discuss, this matter. Sincerely, i ~!1~ Cyndi Karoly, Supervisor 401 Oversight/Express Review Permitting Unit CBK/jg cc: James Shern, USACE Raleigh Regulatory Field Office Lauren Witherspoon, DWQ Raleigh Regional Office File Copy Central Files Pam Kistner, P.E., Dewberry & Davis, Inc., 2301 Rexwood Dr., Suite 200, Raleigh, NC 27607 Larry J. Ragland, RLA, ALSA, McNeely Associates, 5501 McNeely Drive, Raleigh, NC 27622