HomeMy WebLinkAbout19980382 Ver 1_More Info Requested_20160603Strickland, Bev From: Larsen, Cory Sent: Friday, June 03, 2016 2:41 PM To: 'John Vilas'; Price, Zan (George) Cc: Leslie, Andrea J; 'Elliott, William A SAW'; Bob Grasso (bgrasso@landplancollab.com) Subject: RE: Request for Additional Information - Poplar Ridge Lot 126 - Buncombe County - DWR 98-0382 V2 John I've reviewed the additional information and have the following comments that will need to be addressed: There are a number of inconsistencies between values shown on Table 1 of the supplement form, the SMP site plan and detail drawings, and the calculations sheet. Please revise as necessary for consistency; Please modify the swales to ensure a flow velocity of less than or equal to 2 feet per second (current design is for 2.1 fps and 2.4 fps on swales 1 and 2, respectively). Two feet per second is considered the maximum non-erosive velocity for this review; For swale 1, the calcs indicate a bottom width of 6 ft and top width of 7.5 ft and side slope of 3:1. Swale 2 calcs similarly indicate bottom width of 8.5 ft, top width of 10 ft and side slope of 3:1. A 3:1 side slope is not possible with the given dimensions. Please provide clarification or revise. Thank you. Cory Larsen, PE Stormwater Engineer 401 & Buffer Permitting Branch NCDEQ — Division of Water Resources 919.807.6379 office cory.larsena-ncdenr.gov 1617 Mail Service Center Raleigh, North Carolina 27699-1617 }: Nothing Compares Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: John Vilas [mailto:john.vilas@mcgillengineers.com] Sent: Thursday, June 02, 2016 1:04 PM To: Price, Zan (George) <Zan.Price@ncdenr.gov> Cc: Leslie, Andrea J <andrea.leslie@ncwildlife.org>; 'Elliott, William A SAW' <William.A.Elliott@usace.army.mil>; Larsen, Cory <cory.larsen@ncdenr.gov>; Bob Grasso (bgrasso@landplancollab.com) <bgrasso@landplancollab.com> Subject: RE: Request for Additional Information - Poplar Ridge Lot 126 - Buncombe County - DWR 98-0382 V2 Za n, In response to your Request for Additional Information dated May 13, 2016, we have prepared a stormwater management plan for the site that shows how the low density criteria are satisfied. Attached is a stormwater management plan for Lot 126 and a Low Density Supplement Form. The approach is to discharge all roof gutter drains and sheet flow from the upper part of the driveway into the grassed yard area around the house. This water will collect and be conveyed off-site through broad grassed swales. These swales have longitudinal slopes greater than 10% but we calculated 10 -yr. velocity and sheer stress (tractive force) and both will easily handle the 10 -yr. flow. Runoff from the lower portion of the driveway will sheet flow directly to grassed areas or natural forested areas. Please let me know if you have any questions or require additional information. Thank you, John John Vilas Program Services Manager - Environmental qMcGiH 468 New Market Blvd. Suite B I Boone, NC 28607 Phone: 828.386.1920 1 Cell: 828.964.3962 1 Fax: 828.386.1923 0ohn.vilas@mcgillengineers.com I www.mcgillengineers.com From: Price, Zan (George) [mailto:Zan.Price@ncdenr.gov] Sent: Friday, May 13, 2016 11:17 AM To: John Vilas<john.vilas@mcgillengineers.com> Cc: Leslie, Andrea J <andrea.leslie@ncwildlife.org>; 'Elliott, William A SAW' <William.A.Elliott@usace.army.mil>; Larsen, Cory <cory.larsen@ncdenr.gov> Subject: Request for Additional Information - Poplar Ridge Lot 126 - Buncombe County - DWR 98-0382 V2 The Division of Water Resources (DWR) has performed a review of a 401 Water Quality Certification application dated April 15, 2016 and received by DWR on April 22, 2016 for the above referenced project. The DWR has determined that your application is incomplete and cannot be processed. The application is on -hold until the following information is received: 1. Per Water Quality General Certification No. 3890, this project is required to provide a stormwater management plan (SMP) to protect water quality (regardless of project area or amount of impervious area). Please see Appendix A of the General Certification, available here, and submit a plan that is in accordance with low density project stormwater requirements. Alternatively, you may provide a copy of the locally reviewed SMP with proof of approval if the jurisdiction is certified for 401 stormwater management plan reviews. Pursuant to Title 15A NCAC 02H .0502, the applicant shall furnish all of the above requested information for the proper consideration of the application. If all of the requested information is not received within 30 calendar days of receipt of this email, the DWR will be unable to approve the application and it will be returned. The return of this project will necessitate reapplication to the DWR for approval, including a complete application package and the appropriate fee. Feel free to submit the above requested information to me via email. Contact me if you have any questions or concerns. Regards, Zan Price, P.E. Assistant Regional Supervisor — Asheville Regional Office Water Quality Regional Operations Section NCDEQ — Division of Water Resources 828 296 4662 office 828 231 9634 mobile zan.price(cDncdenr.gov 2090 U.S. Hwy. 70 Swannanoa, N.C. 28711 ��NothingCornnpares.] Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties.