Loading...
HomeMy WebLinkAboutNCG030130 DMR SW (13)ENE, It4c. November 30, 2015 , Mr. Ryan Pennington DEC 14 2015 Gastonia Components and Logistics Daimler Trucks North America, LLC CSN7-PML FILA 1400 Tulip Drive D11vR SECDON Gastonia, NC 28052 Subject: Monthly Sampling—November 2015 NPDES General Permit No. NCG030000 Certificate of Coverage No.(}3E9'•_, Daimler Trucks, Gastonia Cnents ani Logistics, LLC ompo 1400 Tulip Drive Gastonia, North Carolina Shield Project No. 1140099-02 Dear Mr. Pennington. Shield Engineering, Inc. (Shield) successfully collected monthly storrawater samples for Stormwater Discharge Outfall (SDG) #001 at the Gastonia facility for the month of November. The analytical results of the storinwater samples collected during a qualifying storm event on Novomber 2, 2015 for SDO /#001 are attached to this cover letter. In addition, a completed (111tilittitive monitoring report for SDG 9001 and aYartially completed DMR form are attached to this Oover letter, Results %otrt the November 2" sampling event show an exceedance of the following ptiran10tets at s)r, above die corresponding benchmarks ,% Sno 8001 — Copper— 0.0162 ing/L (13enchma k 0,007 ing/L) Basud Oil tlic excoodalloo results of („oppQr tit SDO 4001 for the month of November, Daimler's Gastonia facility roillaitas in Tior Tlia'et” of the NPDES General Permit No. NCG030000 at SDO ##001, Monthly S-Umpling tit SOO 11,002 is no longer required due to three consecutive non- excudanocs. Sllield will conduit; to perlbrm monthly sampling at SDO #001 per Tier 3 requirements until tttstructod to halt by eithor Daimler or the DWQ, Shield greatly appreciates the opportunity to provide cnvirotaniontal services to Daimler Trucks, of North America. If you have lily questions hi reference to this document or require further inforination, please feel free to contact either of the undersigned at (704) 391-6913. Respectfully, SHIELD ENGINEVIVUNG, INC. 4z;, --,Z� pian L. Fowler, B.I. lV ark C, Boland,1�.-. StaffEsigineer P incipal Engineer Attacditimits; Stdt°a water Discharge N1Ouitoring Report (MIR) %tepttotto 704,394,0913 4301 i0Mt9utt CWa-k ROAd www,cNiol�aogineeeing,e�m Fax 704,394.6960 ChaHotto, NG 211200 AN6 9 �( 5 NC® NR Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report hc�-o �/3T For guidance on filling out this form, please visit: http://portal.ncdenr.orglweb/wq/ws/sulnl2dessw#tab- Permit No.: N/C/0 /3 /0/ 0/ 0 / 0 / 0 / or Certificate of Coverage No.: Facility Name: Daimler - Gastonia County: Gaston Phone No. Inspector: T. r s0, 1!5 -11A - Date of Inspection: 04/1'5— Time 4/1'5—Time of Inspection:lit � n Total Event Precipitation (inches): Was this a "Representative Storm Event" or "Measureable Storm Event" as defined by the permit? (See information below.) ® Yes ❑ No Please verify whether Qualitative Monitoring must be performed during a "representative storm event" or "measureable storm event" (requirements vary, depending on the permit). Qualitative monitoring requirements vary. Most permits require qualitative monitoring to be performed during a "representative storm event" or during a "measureable storm event.", However, some permits do not have this requirement. Please refer to these definitions, if applicable. A "representative storm event" is a storm event that measures greater than 0.1 inches of rainfall and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than 0.1 inches has occurred. A single storm event may contain up to 10 consecutive hours of no precipitation. A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72 -hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DWQ Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: (Signature of Permittee or Designee) Page 1 of 2 SWU-242, Last modified 10/25/2012 1. Outfall Description: Outfall No, 00 1 Structure (pipe, ditch, etc.) Receiving Stream: Describe the industrial activities that occur within the outfall drainage area: 2, Color: Describe the color of the dis barge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: G%�P-��� - 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weals chlorine oder, etc.): w•ivAL-- 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 (3- 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 10 2 3 4 5 7. Is there any foam in the stormwater discharge? Yes No 8. Is there an oil sheen in the stormwater discharge? Yes No 9. Is there evidence of erosion or deposition at the outfall? Yes No 10, Other Obvious Indicators of Stormwater Pollution: List and describe fv-✓`-- Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 10/25/2012