Loading...
HomeMy WebLinkAboutNCC243531_Site Plan or Location Map_20241115 1 2 3 4 5 6 7 8 — -- 61.US highway 264 E US Highway 264 E=, ISSUED FOR PERMITTING New Energy Development Company LNG FACILITY EXPANSION,PHASE 3A Baldwin Swamp awS; GREENVILLE, NC D HDR Project No:10363640 Old Pn:t0"Pd dryly Ol Bra rdenbm 0' S1e�en s� PROJECT LOCATION INDEX RA DRAWINGS: — QaGENEL Caleo 5l xoldp dJ� 01C-01-000 COVER SHEET CIVIL O Bradford C,ee4 Golf Course 01C-1-001 CIVIL GENERAL NOTES Ili. 01C-5-000 EXISTING GRADING CONDITIONS 01C-5-001 PROPOSED LAYDOWN AREA 01G5-002 EROSION AND SEDIMENTATION CONTROL PLAN-PHASE 1 01C-5-003 EROSION AND SEDIMENTATION CONTROL PLAN-PHASE 2 01C-5-004 DEMOLITION AND RELOCATION PLAN 01G5-005 GRADING AND DRAINAGE PLAN - _ 01C-5-006 PAVING AND COVERING PLAN 01C-5-007 ROAD PLAN,PROFILE,AND CROSS-SECTION 01C-5-008 UNDERGROUND COMPOSITE PLAN ' -_ 01C-7-001 GRADING SECTIONS - 01C-8-001 EROSION AND SEDIMENTATION CONTROL-TYPICAL DETAILS C 01C-8-002 EROSION AND SEDIMENTATION CONTROL-TYPICAL DETAILS ' , _ 01C-8-003 EROSION AND SEDIMENTATION CONTROL-TYPICAL DETAILS -500 01C-8-004 EROSION AND SEDIMENTATION CONTROL-TYPICAL DETAILS tlk a ����� , 01C-8-005 EROSION AND DRAINAGE, SEDIMENTATION CONTROLDET -TYPICAL DETAILS VICINITY MAP -iSS , I SURVEY(BY OTHERS) GRADING,DRAINAGE,AND UTILITY DETAILS SCALE:1"=1000' - SU1 LOCATION&TOPOGRAPHIC SURVEY J I �i —I - SITE DATA tt. ll PROJECT NAME: LNG FACILITY EXPANSION,PHASE 3A DEVELOPER: NEW ENERGY DEVELOPMENT COMPANY I �7i11, 160 FEDERAL STREET,18TH FLOOR 1 BOSTON,MA 02110 �{ `�fI P:978-686-4583 • SITE CIVIL PLANS BY: HDR ENGINEERING,INC.OF THE CAROLINAS _ V,_ 440 S.CHURCH ST,SUITE 1200 - CHARLOTTE,NC 28202 7 OWNER: CITY OF GREENVILLE B a.. PO BO 720 GREENVILLE,NORTH CAROLINA 27835 - S ` P.252-329-4444 I �¢ 5 1 I I I 1 1 I PARCEL AREA: 106 AC I I .`.i PIN: 5608425792 PARCEL NUMBER: 022506 '�' - . . e - 4. - •- /�. ADDRESS: 4150 NATURAL GAS DRIVE GREENVILLE,NORTH CAROLINA 27835 / I 1 WATERSHED.TURBANCE: TAR PAMLICO a / �.. r �� r _ _ ._ EXISTING IMPERVIOUS: 0.27 AC -NW I PROPOSED IMPERVIOUS: 0.46 AC }�/ SUNNYSIDE RD/S.R.1535 I t RNV 60' / I PARKING DATA I p TOTAL PARKING SPACES: 11 SPACES / ZONING SUMMARY / • fli EXISTING ZONING: RA ji PROPOSED LAND USE: LIQUEFIED NATURAL GAS STORAGE FACILITY I;I - MINIMUM BUILDING SETBACKS: 40 FT A BUFFER REQUIRED: 10 FT SCALE: 1"=100' PROJECT MANAGER TORRI BORGIANINI FD/ DESIGNED BY V.HAYNES s New Energy N COVER SHEET DRAWN BY F.LUNTE . Development Company CHECKED BY K.MESSINGER STRATEGY I PROJECT DEVELOPMENT I CAPITAL LNG FACILITY EXPANSION, PHASE 3A 1 11/05/2024 ISSUED FOR CONSTRUCTION GREENVILLE, NORTH CAROLINA FILENAME 10363640-01C-1-000.DWG SHEET 0 10/14/2024 ISSUED FOR CONSTRUCTION 01 C-1-000 ISSUE DATE DESCRIPTION PROJECT NUMBER 10363640 SCALE NONE