HomeMy WebLinkAboutNCG021049_Scanned Site Plans8_20241114 2 3 4 6 8
0 1100 CONSTRUCTION, MAINTENANCE AND INSPECTION NOTES
TOP OF BERM. ELEV 838.00
zn 1\ 4 DRAINAGE AREA -j 20' WIDTH 4
I /\\ / \�, ' 4 /X�< DELINEATION scALEJ FEE�T 1. INSPECT SEDIMENT BASINS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 Cumulative Storage
/x
'X
LIMIT OF INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY.
DISTURBANCE ELEV 836.50
839.00
2. REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN IT Ar
< ACCUMULATES TO ONE-HALF THE DESIGN DEPTH. PLACED REMOVED SEDIMENT IN AN TOP OF BERM
838.00 38.00
�'/\X 0�1x N\\;\<,
AREA WITH SEDIMENT CONTROLS,
X
3. CHECK EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, AND INSPECT 837.00 837.00
THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS EMERGENCY SPILLWAY
Z- _ / TCHAINLINK FENCE 36.50
SEE DETAIL SHEET BOG-01 1
I IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE RISER AND POOL SECTION B 836.00 36.00
AREA.
T �{ i ` -�I
35.50 PRINCIPAL SPILLWAY
PROPOSED SITE X 835.00
CLASS 1 RIP-RAP .0 35.00
--ACCESS ROAD CID 4-1 D
0o > 834.25 CLEANOUT ELEV.
EMERGENCY SPILLWAY -T 834.00 .00
'ELEV. 836.50 NON-WOVEN GEOTEXTILE FABRIC LU
SEE DETAIL THIS SHEET BETWEEN ALL SOIL AND RIP-RAP. 19', ELEV. 8,�6.5 -COMPACTED FILL ON TOP OF
POROUS BAFFLES 833.00 833.00
ANCHOR IN FABRIC BY RUNNING VIRGIN SOIL WITH TOP SOIL
SEE DETAIL SHEET OOG-01 T -- i1I
SILT FENCE ALONG FACE OF SPREADER LIP TO REMOVED.
"� , >1
TOP OF FOOTER. VIRGIN GROUND 832.00
SEE DETAIL SHEET 001I \\Y\l \�<�/X�Oy\\�;/'\1<N\Y\\�;0� /X�\6\�1 NI\� 1.1
31 ELEV: 836 X A/
POND BOTTOM 831.00
ELEV: 832.00
11A-N
K
830.00
<
V V W
PIPE 1A-N ( SEE CULVERT
o\�\)' ��x x// /x�/x� A VA 0.00 OA9 0,61 1.01 1.30 1.59 1.90 2.21 2.89
SUMMARY TABLE ON
SHEET OOG-005) OUTLET PROTECTION OP-201, Cumulative Storage (ac-ft)
-SEE SUMMARY SHEET OOG-005 KEY IN RIP-RAP KEY IN RIP-RAP
N-12 ST HDPE PIPES, CID BOTTOM OF POND SECTION A
JOINTS SHALL BE SOIL TIGHT "ELEV. 833.00
EMERGENCY SPILLWAY Basin Vize
DOUBLE INLETS AT
LOW POINT, PROVIDE NOT TO SCALE
Ellev. (Irnsf) Depth(11) Areas Cumul.lative Volume ft)
INLET PROTECTION
DURING CONSTRUCTION833.00 0.00 20,173 0.00
It/ I ARM ASSEMBLY -
72" OUTLET STRUCTURE WITH
SKIMMER AND 50 LF OF 30" 0 HP STORM,�,1
834.013 1.00 22,098 11149
DUAL WALL PIPE, ADS OR EQUIVALENT. &34.25 1.25 22,588 0.61
�j
SEE DETAILS THIS SHEET W5.00 2.00 24,079 1.01
1 B-N_� C" ENCLOSURE
""j- 835.50 2.50 25,091 130
PIPE 1B-N SEE CULVERT
4
836.00 3.00 26,116 1.59
SUMMARY TABLE ON----- x
SHEET OOG-005) -4--�� OUTLET PROTECTION OP-201, 8W.50 3.50 1.90 C
SEE SUMMARY SHEET OOG-005
WATER ENTRY UNIT 837.00 4.00 28,211 2-21
PROPOSED A/ PERSPECTIVE VIEW 5 no, 30,362 289
PLANT BUILDING I OUTLET PROTECTION OP-201A,,-.-
AND EQUIPMENT ><SEE SUMMARY SHEET OOG-005
PVC VENT SCHEDULE 40
PVC ELBOW PIPE PVC PIPE
TOP OF BERM ELEV. 838.00 PVC END CAP
TOP OF BANK DIAMETER
PIPE DIAME
-177, -201 SEDIMENT BASIN 201 PRINCIPLE SPILLWAY
WATER SURFACE
I IBASIN ACCESS ROAD 30 STREAM BUFFER I Skimmer Design SB Req'd Vol (c�� 18,684 DESIGN INFORMATION
PVC END CAP Desired Skimmer Drawdown Time (td)6 72 hrs
SCHEDULE 40 Desired Skimmer Drawdown Rate (0d) 6,228 W/day Outlet: Sediment Basin 201 Principle Spillway, Drop Pipe
4" PVC PIPE Riser Top Elev: 835.50 ft
PLAN VIEW PVC PIPE PIPE DIAMETER Skimmer Size 4.0 in Riser Length: 6.0 ft
SCALE 1" 50' 1/2" HOLES IN Head on Orifice (H)5 0.333 ft Orifice Coefficient: 0.60
UNDERSIDE
PVC TEE Weir Coefficient: 3.1
INSTALL COLLAR WITH CORRUGATIONS CUTOFF TRENCH ALIGNS PVC TEE 2,25" DIA, ORIFICE PLATE Culvert Length: 70.00 ft
FLEXIBLE
VERTICAL. COLLAR TO BE OF SAME GAGE WITH � EMBANKMENT Calculated Orifice Diameter7 2.162 in Culvert Diameter: 30.00 in
AS THE PIPE WITH WHICH IT IS USED. COUPLING WITH Culvert Invert In: 832.50 ft
7 7-7-- Actual Orifice Diameter 8 2.250 in
NOTES:
TRANSITION TO Culvert Friction Coefficient: 0.01
7
1 1 1 BAND -EXISTING GROUND SKIMMER PIPE - 1. ALL PVC PIPES ARE TO BE SCHEDULE 40 UNLESS Actual Skimmer Drawdown Time 66 hrs Culvert Entrance Loss Coefficient: 0.90
1/2"X 2" SLOTTED OTHERWISE NOTED.
FILL MATERIAL-
2 HOLES @ 8" C.C. 2' MINIMUM IF NOT 2. ALL JOINTS OF THE FLOTATION SECTION SHALL BE Discharge.- 62.37 cfs
FOR 3/8"0 BOLTS - 1 " STAINLESS
CUT TO BEDROCK SOLVENT WELDED. JOINTS OF SKIMMER SECTION NEED Required Discharge: 62.00 cfs
-01 0� 01 1 0 STEEL STRAP
+ NOT BE WATER-TIGHT.
21; - OD OF PIPE 3. HDPE FLEXIBLE DRAIN PIPE IS TO BE ATTACHED TO THE
I I I PIPE BARREL STRUCTURE WITH WATER-TIGHT
01 0 101110, 10 END VIEW 1 STAINLESS STEEL STRAP B
CONNECTIONS.
4. SKIMMER SIZES AND ORIFICE DIAMETERS ARE CALCULATED
CE SADDLE BRANCH CMP CONNECTION BASED ON NCDEQ DESIGN METHODOLOGY AND WILL BE
21 (EXTEND ADEQUATE DISTANCE FROM RISER) REVIEWED AND APPROVED BY THE ENGINEER ONCE A
ONE PIECE CONNECTING
BAND WELDED TO PIPE; SUITABLE EARTHEN MATERIAL SKIMMER SUPPLIER/MANUFACTURER HAS BEEN CHOSEN.
W: 4' M I N. CONTINUOUS WELD BOTH COMPACTED TO 95% OF STANDARD FRONT VEW RISER BUOYANCY CALCULATION
SIDES OF BAND PROCTOR MAX. DRY DENSITY WITHIN
±2% OPTIMUM MOISTURE CONTENT DEMONSTRATE ADEQUATE STABILITY BY SHOWING THE DOWNWARD FORCE IS A
CUT-OFF TRENCH SKIMMER MINIMUM OF 1.25 TIMES THE UPWARD FORCE.
ANTI-SEEP COLLARS NOT TO SCALE NOT TO SCALE DOWNWARD FORCE (STRUCTURE WEIGHT) > 1.25 x UPWARD FORCE (BUOYANCY)
NOT TO SCALE
TRASH RACK 72" CONCRETE RISER
SKIMMER, SEE DETAIL- 10' TOP OF --Jm- EMERGENCY SPILLWAY, SEE DETAIL THIS WEIGHT= 15,220 lb
THIS SHEET RETRIEVAL ROPE- BERM WIDTH SHEET
ANCHORED IN WHERE:
6'x6' (INSIDE- THE SLOPE
DIMENSION) RISER SEDIMENT 72" CONCRETE �VFREEBOARD RIISER WEIGHT= 15,220 lb
RISER STRUCTURE MIN. 1' FREEBOARD TOP OF BERM. ELEV 838.00
STRUCTURE CLEANOUT
GAGE WEIGHT OF CONCENTRATE BASE (LENGTH x WIDTH x DEPTH) x UNIT
WEIGHT OF CONCRETE
CONCRETE-----._ ------ ---0.5' DEPTH OF FLOW
BASE DO 1[] 1-1 0 0110110 EMERGENCY SPILLWAY ELEV 836.50 4 SEDIMENT CLEANOUT WEIGHT OF CONCRETE BASE (8.0 ft x 8.0 ft x 2.0 ft) x 150 lb/ft' 19,200 lb
1 11101101 ]ILIE] x /Z
MARK, ELEV 834.25 U110 1-1 J11011111 RISER CRESTELEV. 835.50 //\X
SKIMMER, EMBANKMENT STABILIZED STRUCTURE WEIGHT= 15,220 lb + 19,200 lb = 34,420 lb
SEE DETAIL WITH VEGETATION NOTES BUOYANCY= DISPLACEMENT VOLUME OF RISER x 62.4 lb/ft'
THIS SHEET 3 CUT OFF TRENCH 3
OUTLET APRON BUOYANCY = 216 ft'x 62.4 lb/ft'= 13,478.4 lb
Zo 30" DIA. CMP
BOTTOM INV. ELEV 832.50 30" IDIA. CMP 00 DOWNWARD FORCE (STRUCTURE WEIGHT) > 1.25 x UPWARD FORCE (BUOYANCY)
------ 000
ELEV 833.00 C, 34,420 lIb > 13,478.4 lb x 1.25
34,420 lb > 16,848 lb
ANTI-SEEP COLLAR 1. PORTLAND CEMENT CONCRETE (TYPE 11 RECOMMENDED) FOR THE INLET BASE
CONCRETE BASE 20' EVERY-------,- SEE DETAIL THIS SHEET SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4,000 PSI.
7.0' x 7.0'x 1.0' 20' 2. WHERE CORRUGATED ALUMINUM OR ALUMINIZED STEEL PIPE IS USED, ALL
NOTES: AREAS WHERE THE PIPE IS TO BE IN CONTACT WITH CONCRETE SHALL BE PAINTED
1. FAIRCLOTH TYPE OR EQUIVALENT SKIMMER TO BE USED. WITH A BLACK BITUMINOUS ENAMEL PAINT.
RISER PLAN VIEW 2. INSTALL ANTI-VORTEX PLATE IN RISER STRUCTURE.
NOT TO SCALE SEDIMENT RISER BASIN
NOT TO SCALE
...........
PROJECT MANAGER V. HAYNES, PE
PIEDMONT LITHIUM CAROLINAS, INC.
C A R PIEDMONT SEDIMENT BASIN SB-201 ,
R� ........
CAROLINA LITHIUM PROJECT
7 "1
PLAN VIEW & PROFILE DETAIL
SE
5 3/13/2024 REVISED PER DEMLR COMMENTS
4 1/23/2023 REVISED PER DEMLR COMMENTS 0 2 LITHIUM HYDROXIDE CONVERSION PLANT
3 5/31/2022 REVISED PER DEMLR COMMENTS I*N* GASTON COUNTY, NORTH CAROLINA SHEET
P I E DPA NT HDR Engineering Inc.of the Carolinas 2 12/08/2021 REVISED PER DEMI-R-COMMENTS K FILENAME 01CP-13004
440 S.Church Street,Suite 1200 \�' 3/2024
1 8/27/2021 MINING PERMIT 1111111110%%\
LLVV/-\l
�50 SCALE I F i
E
LITHIUM Charlotte, NC 28202-2075
704.338.6700 ISSUE DATE DESCRIPTION PROJECT NUMBER 10302238 SCALE 1 50' 01 CP-B004
N.C.B.E.L.S.License Number: F-0116