Loading...
HomeMy WebLinkAboutWQ0023634_Monitoring - 08-2024_20240930Monitoring Report Submittal Permit Number#* Name of Facility:* Month: * August Report Information Type * GW-59 Confirmation Email Address: Name of Submitter: * Signature: Date of submittal: Initial Review WQ0023634 Waterside Villages WWTP Year:* 2024 Upload Document* Waterside Villages GW59.pdf 5.52MB PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). rod.holley@currituckcountync.gov Rod Holley Reviewer: Wanda.Gerald 9/30/2024 This will be filled in automatically Is the project number correct?* WQ0023634 Is the monitoring report accepted?* Yes No Regional Office* Washington Reviewer: _anonymous Review Date: 11/7/2024 GW-59A COMPLIANCE REPORT FORM Permit # 0-6 Z3 639 (Submit one each monitoring period with GW-59 forms.) 1 Enter date monitoring results were due. L Will this monitoring report (GW-59 and GW-59A) YES O be submitted after the established due date? 2 Was any required information missing on the GW-59 report forms? YES NO IF the answer to question 1 or 2 is "YES", list in the space provided below the well identification number(s) and explain the problems encountered in obtaining the required information. 3 Are any of the monitor wells in need of repair or maintenance (damaged casing, unlocked or missing cap, missing NO identification plate, area overgrown, etc.)? If the answer is "Yes ", contact the Regional Office for guidance. ;YE 4 Are any monitored constituents equal to or above the established standards? NO If the answer to question 4 is "NO", skip to section 8. If the answer to question 4 is "YES" list the affected wells individually with constituent(s) and concentration(s) exceeding standards in the space provided below: -0 i oC - Ia,9 5 For the constituents identified in question 4 above, have standards been exceeded previously for the ES NO same constituent(s) in the same well(s) in the last two years? If the answer to question 5 is "NO", skip to section 8. If the answer to question 5 is "YES", list in the space provided below, each well with constituent(s) exceeding standards, concentration(s) reported, and sample collection date for each occurrence (for the last two years). V2q TOC, 1 0, 9 I Z/Z3 6 Are the monitoring wells listed in section 5 located at or beyond the review boundary? YES O If the answer is "YES", a groundwater quality problem may be occurring. CONTACT THE REGIONAL OFFICE IMMEDIATELY FOR GUIDANCE. If the answer is "NO", monitoring wells maybe improperly located; contact the Regional Office. 7 Is the permittee implementing previously approved actions required by the Division involving this YES groundwater quality problem? If the answer to question 7 is "YES", describe those actions in the space provided below. If the answer to question 7 is "NO", contact the Regional Office within 90 days; an evaluation may be required to determine the impact the waste disposal system is having at the review and compliance boundaries surrounding this facility. Failure to do so may subject the permittee to a Notice of Violation, l fines, and/or penalties. ovD i, 5,yW&-' It N AIR- M K S Mo,Vi g The person completing this portion (GW--59A) of the monitoring report should sign below and submit this form with GW-59 forms for required wells to the address provided at the top of the current GW-59 form. I hereby acknowledge that the above information was evaluated and the information submitted in this report (Compliance Report GW-59A) is true and complete to the best of my knowledge. �& J jj4vV44 9,�3v�z Signature of Permittee (or Author' ed Agent) Date GW-59A 12/8/2003 SUBMIT FORM ON YELLOW PAPER ONLY DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: DIVISION OF WATER QUALITY -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 11611 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: (919) 733-3221 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: WQ0023634 Expiration Date: 11/30/30 Facility Name: Waterside Villages WWTP Non -Discharge UIC Permit Name (if different): NPDES Other Facility Address: 100 Pirate Quay TYPE OF PERMITTED OPERATION BEING MONITORED Grandy NC (street' NC 27939 County Currituck ❑ Lagoon ❑ Remediation: Infiltration Gallery lit"; (State) (zip) ❑ Spray Field ❑ Remediation: Contact Person: Rod Holley Telephone#: 252-232-6065 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Waterside Villages No. of wells to be sampled: 5 ❑ Water Source Heat Pump ❑■ Other: Infiltration (from Permit) SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW10 Date sample collected: 8/12/24 FIELD ANALYSES: WAS Well Depth: 16 ft. Well Diameter: 3 in. pH 00400: 6.1 units Temp. 000lo: 22.4 °C DRY at Depth to Water Level 82546:10.0 ft. below measuring point Screened Interval: 12 ft. to 17 ft. Spec. Cond. 00094: µMhos time of sampling, Measuring Point is 2 ft. above land surface Relative M.P. Elevation: ft. Odor 00085: None check Volume of water pumped/bailed before sampling: 3.0 gallons Appearance Rust here:❑ Samples for metals were collected unfiltered: © YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed:8/12/24 Laboratory Name: Enviro Chem Certification No. 94 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 <0.02 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 <1 /100mL Nitrate (NO3) as N 00620 0.08 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 0.24 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 168 mg/L Al - Aluminum oil o5 mg/L pH (Lab) 00403 6.1 units Ba - Barium 01007 ug/L TOC 00680 10.4 mg/L Ca - Calcium oo916 mg/L Chloride 0094o 20 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 78732: method # Total Ammonia 00610 0.3 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH, as N; Ammonia Nitrogen, Total) Mn - Manganese olo55 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Rod Holley Wastewater Superintendent Permittee (or Authorized Agent) Name and Title - Please print or type & �' _u Signature of Permittee (or Autholzed Agent) 9/30/24 (Date) GW-59 Rev.212010 SUBMIT FORM ON YELLOW PAPER ONLY • • DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: • • • • DIVISION OF WATER QUALITY -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: (919) 733.3221 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: WQ0023634 Expiration Date: 11/30/30 Facility Name: Waterside Villages WWTP Non -Discharge UIC NPDES Other Permit Name (if different): Facility Address: 100 Pirate Quay TYPE OF PERMITTED OPERATION BEING MONITORED ❑ Lagoon ❑ Remediation: Infiltration Gallery Grandy NC (street) NC 27939 County Currituck (State) (Zip) Spray Field El Remediation: Contact Person: Rod Holley Telephone#: 252-232-6065 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Waterside Villages No. of wells to be sampled: 5 ❑ Water Source Heat Pump N Other: Infiltration from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW11 Date sample collected: 8/12/24 FIELD ANALYSES: WAS Well Depth: 16 ft. Well Diameter: 3 in. pH 00400: 6.4 units Temp. 000lo: 20.1 °C DRY at Depth to Water Level 82546:10.0 ft. below measuring point Screened Interval: 12 ft. to 17 ft. Spec. Cond. 00094: µMhos time of sampling, Measuring Point is 2 ft. above land surface Relative M.P. Elevation: ft. Odor 00085: None check Volume of water pumped/bailed before sampling: 4.5 gallons Appearance Clear here:❑ Samples for metals were collected unfiltered: ® YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed:8/12/24 Laboratory Name: Enviro Chem Certification No. 94 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 <0.02 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 <1 /100mL Nitrate (NO3) as N 00620 1.00 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 0.27 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 703oo 490 mg/L Al - Aluminum oil o5 mg/L pH (Lab) 00403 6.4 units Ba - Barium 01007 ug/L TOC 0068o 4.1 mg/L Ca - Calcium 00916 mg/L Chloride 00940 148 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 78732: method # Total Ammonia oo6lo <0.2 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH3as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Rod Holley Wastewater Superintendent Permittee (or Authorized Agent) Name and Title - Please print or type Siqnature of Permittee (or Authorized Aqent) 9/30/24 GW-59 Rev.2/2010 SUBMIT FORM ON YELLOW PAPER ONLY • • DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: • • • • DIVISION OF WATER QUALITY -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: (919) 733-3221 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: WQ0023634 Expiration Date: 11/30/30 Facility Name: Waterside Villages WWTP Non -Discharge UIC Permit Name (if different): NPDES Other Facility Address: 100 Pirate Quay TYPE OF PERMITTED OPERATION BEING MONITORED Grand NC (Street) NC y 27939 Count Currituck y El Lagoon El Remediation: Infiltration Gallery (Cite) (State) ;'zips El Spray Field Remediation: Contact Person: Rod Holley Telephone#: 252-232-6065 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Waterside Villages No. of wells to be sampled: 5 ❑ Water Source Heat Pump ❑■ Other: Infiltration from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW12 Date sample collected: 8/12/24 FIELD ANALYSES: WAS Well Depth: 16 ft. Well Diameter: 3 in. pH 00400: 6.3 units Temp. 000lo: 20.7 °C DRY at Depth to Water Level 82546:8.8 ft. below measuring point Screened Interval: 12 ft. to 17 ft. Spec. Cond. 000sa: µMhos time ofsampling, Measuring Point is 2 ft. above land surface Relative M.P. Elevation: ft. Odor 00085: None check Volume of water pumped/bailed before sampling: 4.0 gallons Appearance Clear here:❑ Samples for metals were collected unfiltered: © YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed:8/12/24 Laboratory Name: Enviro Chem Certification No. 94 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 <0.02 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 6 /100mL Nitrate (NO3) as N 00620 <0.02 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 0.41 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 176 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 6.3 units Ba - Barium 01007 ug/L TOC 0068o 7.6 mg/L Ca - Calcium 00916 mg/L Chloride 0094o 26 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) pecific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 78732: method # Total Ammonia 00610 <0.2 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH3 as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Rod Holley Wastewater Superintendent Permittee (or Authorized Aqent) Name and Title - Please print or type GW-59 Rev.2/2010 SUBMIT FORM ON YELLOW PAPER ONLY • , DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: 6 0 DIVISION OF WATER QUALITY -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 0 0 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: (919) 733-3221 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: WQ0023634 Expiration Date: 11/30/30 Facility Name: Waterside Villages WWTP Non -Discharge UIC Permit Name (if different): NPDES Other Facility Address: 100 Pirate Quay TYPE OF PERMITTED OPERATION BEING MONITORED ❑ Lagoon ❑Remediation: Infiltration Gallery Grandy NC (Street) NC 27939 County Currituck (City) (State) (zip) ❑ Spray Field ❑Remediation: Contact Person: Rod Holley Telephone#: 252-232-6065 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Waterside Villages No. of wells to be sampled: 5 ❑ Water Source Heat Pump IN Other: Infiltration from Permit) SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW13 Date sample collected: 8/12/24 FIELD ANALYSES: WAS Well Depth: 16 ft. Well Diameter: 3 in. pH 00400: 6.2 units Temp. 000lo: 22.5 eC DRY at Depth to Water Level 82546:8.1 ft. below measuring point Screened Interval: 12 ft. to 17 ft. Spec. Cond. 00094: µMhos time of sampling, Measuring Point is 2 ft. above land surface Relative M.P. Elevation: ft. Odor 00085: None check Volume of water pumped/bailed before sampling: 3.5 gallons Appearance Clear here:❑ Samples for metals were collected unfiltered: 0 YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed:8/12/24 Laboratory Name: Enviro Chem Certification No. 94 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 <0.02 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 6 /100mL Nitrate (NO3) as N 00620 1.21 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 <0.04 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 70300 113 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 6.2 units Ba - Barium 01007 ug/L TOC 00680 1.1 mg/L Ca - Calcium 00916 mg/L Chloride 00940 9 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) pecific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 78732: method # Total Ammonia oo610 <0.2 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH, as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Rod Holley Wastewater Superintendent Permittee (or Authorized Agent) Name and Title - Please print or type GW-59 Rev.2/2010 SUBMIT FORM ON YELLOW PAPER ONLY DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: W9 DIVISION OF WATER QUALITY -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: (919) 733-3221 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: WQ0023634 Expiration Date: 11/30/30 Facility Name: Waterside Villages WWTP Non -Discharge UIC NPDES Other Permit Name (if different): Facility Address: 100 Pirate Quay TYPE OF PERMITTED OPERATION BEING MONITORED El Lagoon El Remediation: Infiltration Gallery Grandy NC str t) NC 27939 CountyCurrituck cuyi estate) Op) El Spray Field El Remediation: Contact Person: Rod Holley Telephone#: 252-232-6065 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Waterside Villages No. of wells to be sampled: 5 ❑ Water Source Heat Pump IN Other: Infiltration from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW14 Date sample collected: 8/12/24 FIELD ANALYSES: WAS Well Depth: 16 ft. Well Diameter: 3 in. pH 00400: 6.2 units Temp. 000lo: 19.9 °C DRY at Depth to Water Level 82546:8.8 ft. below measuring point Screened Interval: 12 ft. to 17 ft. Spec. Cond. 00094: µMhos time ofsampling, Measuring Point is 2 ft. above land surface Relative M.P. Elevation: ft. Odor 00085: None check Volume of water pumped/bailed before sampling: 3.5 gallons Appearance Clear here:❑ Samples for metals were collected unfiltered: © YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed:8/12/24 Laboratory Name: Enviro Chem Certification No. 94 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 <0.02 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 11 /100mL Nitrate (NO3) as N 00620 <0.02 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100ml- Phosphorus: Total as P 00665 0.40 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): issolved Solids:Total 7030o 275 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 6.2 units Ba - Barium 01007 ug/L TOC 0068o 2.3 mg/L Ca - Calcium o0916 mg/L Chloride 0094o 68 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 78732: method # Total Ammonia 00610 <0.2 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; NH, as N; Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Rod Holley Wastewater Superintendent Permittee (or Authorized Aqent) Name and Title - Please print or type uvv-by Kev. zlzuiu