HomeMy WebLinkAboutSW1240604_Supplement-EZ Form_20241024 SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
1PROJECT INFORMATION
1 Project Name Workforce Outdoor Training Site
2 Project Area(ac) 11.13
3 Coastal Wetland Area(ac) 0
4 Surface Water Area(ac) 0.01
5 Is this project High or Low Density? High
6 Does this project use an off-site SCM? No
COMPLIANCE WITH 02H.1003(4) •
7 Width of vegetated setbacks provided(feet) 30
8 Will the vegetated setback remain vegetated? Yes
9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A
10 Is streambank stabilization proposed on this project? No
NUMBER AND TYPE OF SCMs:
11 Infiltration System
12 Bioretention Cell
13 Wet Pond
14 Stormwater Wetland
15 Permeable Pavement
16 Sand Filter 1
17 Rainwater Harvesting(RWH)
18 Green Roof
19 Level Spreader-Filter Strip(LS-FS)
20 Disconnected Impervious Surface(DIS)
21 Treatment Swale
22 Dry Pond
23 StormFilter
24 Silva Cell
25 Bayfilter
26 Filterra
FORMS LOADED
DESIGNER CERTIFICATION •
27 Name and Title: D.Harry Luzius Jr.,P.E.
28 Organization: Civil Design Concepts
29 Street address: 168 Patton Avenue
30 City,State,Zip: Asheville,NC,28801
31 Phone number(s): (828)252-5388
32 Email: hluzius@cdcgo.com
Certification Statement:
I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the
information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,
specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here.
Designer
00\\IIII////
�A�°ESSR��/%
a SEAL ro0 _ 4reofDeslgne7Jr 7AA
013102
*oc<4,1, G<Z-ao°
// "1 r \\- /O/2 3/2 2
Seal Date
DRAINAGE AREAS
1 Is this a high density project% Yes
2 If so,number of drainage areas/SCMs 1
3 Does this project have low density areas i No
4 If so,number of low density drainage area: 0
Is all/part of this project subject to previous rule
5 versions? No
FORMS LOADED
DAINAGE AREA INFORMATION Entire Site 1
4 Type of SCM Total Site Sand Filter
5 Total drainage area(sq ft) 518,838 195132
6 Onsite drainage area(sq ft) 369,473 195132
7 Offsite drainage area(sq ft) 149,365 0
8 Total BUA in project(sq ft) 123828 sf 119520 sf
New BUA on subdivided lots(subject to permitting)r•
9 (sq ft) sf _ sf
New BUA not on subdivided lots(subject to
10 permitting)(sf) 123828 sf 119520 sf
11 Offsite BUA(sq ft) sf sf
12 Breakdown of new BUA not on subdivided lots
-Parking(sq ft) 121206 sf 116898 sf
-Sidewalk(sq ft) 1170 sf 1170 sf
-Roof(sq ft) 943 sf 943 sf
-Roadway(sq ft)
-Future(sq ft)
-Other,please specify in the comment box below
(sq ft) 509 sf 509 sf _
New infiltrating permeable pavement on subdivided
13 lots(sq ft) sf
New infiltrating permeable pavement not on
14 subdivided lots(sq ft) sf _
Existing BUA that will remain(not subject to
15 permitting)(sq ft) sf
16 Existing BUA that is already permitted(sq ft)
17 Existing BUA that will be removed(sq ft) 5243 sf 5243 sf
18 Percent BUA 24% 61%
19 Design storm(inches) - 1.0 in
20 Design volume of SCM(cu ft) - 7420 cf
21 Calculation method for design volumE - Simple Method
AD DITIONII!IrIRFORMATIO N
Please use this space to provide any additional information about the
22 drainage area(s):
509 sf BUA accounts for the River Rock border surrounding the building
SAND FILTER
1 Drainage area number 4.47 acres
2 Minimum required treatment volume(cu ft) 7420 sf
GENERAL MDC FROM 02H.1050
3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes
4 Is the SCM located away from contaminated soils? Yes
5 What are the side slopes of the SCM(H:V)? 3:1
Does the SCM have retaining walls,gabion walls or other
6 engineered side slopes? No
7 Are the inlets,outlets,and receiving stream protected from erosion Yes
(10-year storm)?
8 Is there an overflow or bypass for inflow volume in excess of the Yes
design volume?
9 What is the method for dewatering the SCM for maintenance? Pump(preferred)
10 If applicable,will the SCM be cleaned out after construction? Yes
11 Does the maintenance access comply with General MDC(8)? Yes
12 Does the drainage easement comply with General MDC(9)? _ Yes
13 If the SCM is on a single family lot,does(will?)the plat comply with N/A
General MDC(10)?
14 Is there an O&M Agreement that complies with General MDC(11)? Yes
15 Is there an O&M Plan that complies with General MDC(12)? Yes
16 Does the SCM follow the device specific MDC? Yes
17 Was the SCM desi ned b an NC licensed rofessional? Yes
SAND FILTER MDC FROM 02H.1056
18 SHWT elevation(fmsl) 2620.4
19 Type of sand filter(open or closed) Open
20 If closed,will the filter will be pre-cast or pour-in-place?
21 If closed,top of grate elevation(fmsl)
22 Is this sand filter designed to attenuate peak flows? Yes
Sediment Chamber
23 Volume that can be retained in the sediment chamber(cubic feet) 7105 cf
24 Will there be a permanent pool in the sediment chamber? No
25 Bottom of the sediment chamber(fmsl) 2624.00
26 Area of the sediment chamber(square feet) 2903 sf
27 Physical depth of the sediment chamber(inches) 60 in
28 Ponding depth in the sediment chamber,above any permanent 60 in
pool(inches)
29 Elevation of top of weir between chambers(fmsl) 2629
Sand Chamber
30 Volume that can be retained in the sand chamber(cubic feet) 7105 cf
31 Bottom of the sand chamber(fmsl) 2624.00
32 Area of the sand chamber(square feet) 2903 sf
33 Physical depth of the sand chamber(inches) 78 in
Ponding depth in the sand chamber,above the sand surface 60 in
(inches)
35 Elevation of the bypass device(fmsl) 2629
36 Type of bypass device Open Top
Level grading &
37 Mechanism for distributing flow over the sand surface rip rap berm,
standpipe manifold
38 Sand specification for sand chamber "CONCRETE"
SAND ASTM C33
39 Depth above underdrain pipe(inches) 18 in
40 Will the media be maintained to drain at least two inches per hour at Yes
the sand surface?
41 Is at least one clean-out pipe provided at the low point of each Yes
underdrain line?
42 Will clean-out i es be ca ed? Yes
ADDITIONAL INFORMATION
Please use this space to provide any additional information about
43 the sand filter(s):