Loading...
HomeMy WebLinkAboutSW3240501_Supplement-EZ Form_20241004 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Project Hoist 2 Project Area(ac) 29.22 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0.24 5 Is this project High or Low Density? Both High and Low Density 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4)7 Width of vegetated setbacks provided(feet) 30 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No (NUMBER AND TYPE OF SCMs:11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 1 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter 26 Filterra LOAD SUPPLEMENT FORMS DESIGNER CERTIFICATION 27 Name and Title: Erik Messina,PE 28 Organization: Kleinfelder 29 Street address: 9009 Perimeter Woods Dr-Suite E 30 City,State,Zip: Charlotte,NC 28216 31 Phone number(s): 201.602.8677 32 Email: emessina@kleinfelder.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer 001 I I II II signed by Erik P.Messina ‘‘ IA �H 024.10.0112:13:57-04'00' 3/r••ram% ti • 9 • "'f Signature of Designer •63 • • /°, /I P•I M„�\t 1 0/01/2024 Seal Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so,number of drainage areas/SCMs 1 3 Does this project have low density areas? Yes 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 LD 1 4 'Type of SCM Sand Filter Sand Filter none 5 Total drainage area(sq ft) 862,611 _ 477,105 _ 385,506 _ 6 Onsite drainage area(sq ft) 862,611 477,105 385506 7 Offsite drainage area(sq ft) 0 0 0 8 Total BUA in project(sq ft) 358934 sf 351529 sf 7405 sf New BUA on subdivided lots(subject to 9 permitting)(sq ft) N/A N/A N/A New BUA not on subdivided lots(subject to 10 permitting)(sf) 351529 sf 351529 sf 7405 sf 11 Offsite BUA(sq ft) N/A N/A N/A 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) 84474 sf 84474 sf -Sidewalk(sq ft) 4650 sf 4650 sf -Roof(sq ft) 81225 sf 81225 sf -Roadway(sq ft) 20200 sf 20200 sf 7405 sf -Future(sq ft) N/A N/A N/A -Other,please specify in the comment box below(sq ft) 160980 sf 160980 sf New infiltrating permeable pavement on 13 subdivided lots(sq ft) N/A N/A N/A New infiltrating permeable pavement not on 14 subdivided lots(sq ft) N/A N/A N/A Existing BUA that will remain(not subject to 15 permitting)(sq ft) N/A N/A N/A 16 Existing BUA that is already permitted(sq ft) N/A N/A N/A 17 Existing BUA that will be removed(sq ft) N/A N/A N/A 18 Percent BUA 42% 74% 2% 19 Design storm(inches) 1.00 in 1.00 in 1.0 in 20 Design volume of SCM(cu ft) 29911 cf 29294 cf 617 cf 21 Calculation method for design volume Simple Method Simple Method Simple Method ADDITIONAL INFORMATION _ Please use this space to provide any additional information about the 22 drainage area(s): 160,980 SF of gravel impervious area SAND FILTER 1 Drainage area number 2 I 2 Minimum required treatment volume(Cu ft) 29911 sf GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes I 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM(H:V)? 3:1 6 Does the SCM have retaining walls,gabion walls or other engineered No side slopes? 7 Are the inlets,outlets,and receiving stream protected from erosion Yes (10-year storm)? 8 Is there an overflow or bypass for inflow volume in excess of the Yes design volume? 9 What is the method for dewatering the SCM for maintenance? Pump(preferred) 10 If applicable,will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC(8)? Yes 12 Does the drainage easement comply with General MDC(9)? Yes If the SCM is on a single family lot,does(will?)the plat comply with 13 N/A General MDC(10)? 14 Is there an O&M Agreement that complies with General MDC(11)? Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM desi ned b an NC licensed rofessional? Yes SAND FILTER MDC FROM 02H.1056 18 SHWT elevation(fmsl) 755 19 Type of sand filter(open or closed) Open 20 If closed,will the filter will be pre-cast or pour-in-place? 21 If closed,top of grate elevation(fmsl) 22 Is this sand filter designed to attenuate peak flows? Yes Sediment Chamber 23 Volume that can be retained in the sediment chamber(cubic feet) 31000 cf 24 Will there be a permanent pool in the sediment chamber? No 25 Bottom of the sediment chamber(fmsl) 767.00 26 Area of the sediment chamber(square feet) r 4637 sf _ 27 Physical depth of the sediment chamber(inches) r 36.0 in _ 28 Ponding depth in the sediment chamber,above any permanent pool 36.0 in (inches) 29 Elevation of top of weir between chambers(fmsl) 770.00 Sand Chamber 30 Volume that can be retained in the sand chamber(cubic feet) 53888 cf 31 Bottom of the sand chamber(fmsl) 766.00 32 Area of the sand chamber(square feet) 12300 sf 33 Physical depth of the sand chamber(inches) 29 in 34 Ponding depth in the sand chamber,above the sand surface 28,8 in (inches) 35 Elevation of the bypass device(fmsl) 768.4 _ 36 Type of bypass device (3')Wide Weir _ 37 Mechanism for distributing flow over the sand surface Rip rap berm _ 38 Sand specification for sand chamber ASTM C33 _ 39 Depth above underdrain pipe(inches) I 30 in _ 40 Will the media be maintained to drain at least two inches per hour at Yes the sand surface? 41 Is at least one clean-out pipe provided at the low point of each Yes underdrain line? _ 42 Will clean-out i es be ca ed? Yes ADDITIONAL INFORMATION 43 Please use this space to provide any additional information about the sand filter(s): 2