Loading...
HomeMy WebLinkAboutWQ0045470_Additional Information Request #1_20240819 August 19, 2024 ANDREW ROSS – MANAGER PEA RIDGE DEVELOPERS, LLC 341 KILMAYNE DRIVE – SUITE 201 CARY, NORTH CAROLINA 27511 Subject: Application No. WQ0045470 Additional Information Request #1 Firefly Overlook – Lot 24 SFR Single-Family Residence Wastewater Irrigation System Chatham County Dear Mr. Ross, Division of Water Resources’ Central and Regional staff have reviewed the application package received on May 30, 2024. However, the Division requires additional information before completing our review. Please address the items on the attached pages no later than the close of business on September 18, 2024. Please be aware that the Applicant is responsible for meeting all requirements set forth in North Carolina rules and regulations. The Applicant is also responsible for any oversights that occur during the review of the subject application package. The Division may return the application as incomplete pursuant to 15A NCAC 02T .0107(e)(2) if any omissions are made when responding to the outstanding items in Sections A through N or the Applicant fails to provide the additional information on or before the above- requested date. Please reference the subject application number when providing the requested information. The Applicant shall sign, seal, and date (where applicable) all revised and/or additional documentation and submit an electronic response to my attention via the Non-Discharge online portal. If you have any questions regarding this request, please contact me at (919) 707-3658 or zachary.mega@deq.nc.gov. Thank you for your cooperation. Sincerely, Zachary J. Mega, Engineer III Division of Water Resources cc: Raleigh Regional Office, Water Quality Regional Operations Section (Electronic Copy) John R. Harman, PE (Electronic Copy) Laserfiche File (Electronic Copy) Mr. Andrew Ross August 19, 2024 Page 2 of 3 A. Overall: 1. Pursuant to 15A NCAC 02T .0606(a), the Applicant shall maintain for drip irrigation sites: (1) a minimum 50 foot setback to each property line and (2) a minimum 100 foot setback to each habitable residence under separate ownership. Pursuant to 15A NCAC 02T .0606(b), the Applicant shall maintain for treatment and storage units: (1) a minimum 50 foot setback to each property line and (2) a minimum 100 foot setback to each habitable residence under separate ownership. Currently, Pea Ridge Developers, LLC, owns the parent Parcel No. 0018070 that Chatham County will subdivide for Firefly Overlook. Based on the Chatham County GIS and the submitted application package, Lot 24 SFR (Future Parcel No. 0096761) will not meet the setback requirements listed above for the adjacent Lot 23 (Future Parcel No. 0096760) when the Applicant sells the properties to the future homeowners. While setback waivers are not required at this time, the Division strongly recommends that the Applicant obtain all setback waivers pursuant to 15A NCAC 02T .0606(c) in their name based on the proposed subdivision layout to avoid inconvenience for future homeowners. Otherwise, the Division will issue this permit for construction only until we receive all recorded setback waivers. B. Cover Letter: 1. No comment. C. Application Fee: 1. No comment. D. Application (Form: SFRWWIS 06-16): 1. No comment. E. Property Ownership Documentation: 1. No comment. F. Setback Waivers: 1. See Comment A.1. Mr. Andrew Ross August 19, 2024 Page 3 of 3 G. Soil Evaluation: 1. Ms. Dorothy Robson of the Raleigh Regional Office (RRO) conducted a site visit on June 17, 2024, reviewed the submitted application package, and provided the following comments: a. The soil borings provided for the proposed facility do not match t he soils located at the site. Ms. Robson encountered partially weathered bedrock (PWR) refusal between 10 to 14 inches with no substantial clay layer observed, as denoted in the soil borings. Please include on the soil boring logs where the Applicant encountered PWR and update to match the soils/PWR observed at the site. b. Does the Applicant need to add fill due to the depth of PWR? Please explain why the proposed drip irrigation areas do not require fill. H. Engineering Plans: 1. Sheet 2 – a. Please remove the stray property line at the top left corner of the Lot 23 drip irrigation site. b. Please remove the smaller text box cut off above the Lot 23 drip irrigation site for clarity. I. Specifications: 1. No comment. J. Engineering Calculations: 1. No comment. K. Site Map: 1. See Comment H.1. L. Operation & Maintenance Plan: 1. No comment. M. Operation & Maintenance Agreement (Form: SFRWWIS-O&M 09-18): 1. No comment. N. Additional Documentation:  County Health Department Denial Letter: 1. No comment.  Threatened or Endangered Aquatic Species Documentation: 1. No comment.