Loading...
HomeMy WebLinkAboutSW6240601_Design Calculations_20240830 (17) HOMESTEAD POND#2 PRELIMINARY Wet Pond#2 Drainage Area: 1,506,911 sf 34.59 ac Impervious Area: 886,073 sf 20.34 ac %Impervious: 58.8% 1 inch Storm Event: Rv=0.05+0.009 I Rv=runoff coefficient I=percent impervious Rv= 0.5792 For volume that must be controlled: Volume=3,630*Rd*Rv*A Volume required: 72,734 cf Volume provided: 86227 cf Average depth: 5 It SA/DA ratio 1.46841115 Required surface area: 22128 sf Surface area provided: 25715 sf