HomeMy WebLinkAboutNC0089583_CEI Inspection Letter_2024_20240830 August 30, 2024 Jody Reavis NC Division of Parks & Recreation 6254 Salterwhite Point Road Henderson, NC 27536 Subject: 2024 Compliance Evaluation Inspection Hibernia Recreation Area NPDES Permit NC0089583 Vance County Dear Mr. Reavis: On Thursday, August 22, 2024, Kevin Fowler conducted a compliance evaluation inspection of the treatment systems located at Hibernia Recreation Area. The purpose of this visit was to ensure compliance with the subject NPDES facility. During the inspection, the presence and cooperation of John Abbott, Operator in Responsible Charge (ORC), was greatly appreciated. The plant has a Discharging 100% Domestic <1MGD permit. This NPDES compliance evaluation inspection consisted of the following:  Review of the NPDES permit.  Review of the owner/facility information.  Review of March 2021 – March 2024 monitoring data.  Review of March 2021 – March 2024 compliance history.  On-site inspection of the treatment systems; and  On-site inspection of discharge outfall Docusign Envelope ID: 05D2B548-531D-4F66-8C1B-775EE9568B36 Page 2 of 3 Hibernia Recreation Area Compliance Inspection 2024 2 Findings during the pre-inspection file review were: 1. Through NPDES permit NC0089583, Hibernia Recreation Area. is authorized to discharge treated wastewater to a unnamed tributary to Nutbrush Creek/Kerr Lake classified B waters in the Neuse River Basin. The current NPDES permit expired on March 31st, 2022. An application for renewal of this permit does not appear to have been submitted. 2. For the review period July 20219 – July 2024, three (3) violations were found for Ammonia level exceedances. Two (2) civil penalties have been issued for these violations. 3. In speaking with John Abbot prior to the inspection, he indicated that the permitted treatment system is no longer being used and that a subsurface system was installed to take its place. He also indicated that he was in the process of trying to get this permit rescinded. 4. The system according to the permit consists of a septic tank, sand filter, pump tank, tablet chlorination with PVC flow baffle, dosing chamber, and dichlorination sleeves. 5. Annual permit fees for the period ending 3/31/2025, and due 4/14/2024 have not been paid and are overdue. Findings during the inspection: 6. There has been no flow documented on all eDMR submission since January 2022. This is when new subsurface system was completed. 7. John Abbot indicated that the septic tank was crushed in place and backfilled with dirt. He also indicated that all wastewater flow is going to the new subsurface system. 8. The sand filter, pump tank, tablet chlorination tubes, tablet dichlorination tubes, and outfall are still in place. The ORC indicated that he would be acting soon to permanently cap the outfall pipe. 9. The outfall pipe has not been removed or permanently capped at the time of the inspection. The right of way to the outfall was well maintained. No evidence of solids or flow visible. Within 30-days receipt of this letter, please submit a written response to this office indicating the actions you will take or have taken to comply with or resolve the issues noted below. 1. Annual Permit Fee: a. Annual permit fees for the period ending 3/31/2025, and due 4/14/2024 have not been paid and are overdue. The associated permit invoice is attached to this report. Due to the permitted treatment system being disconnected and no longer in use by the facility, the permittee indicated they would like to take action to rescind the permit. In order to rescind an NPDES permit, the outfall pipe needs to either be removed or permanently capped. Also, the facility owner (or authorized representative) should send a letter including the permit number, name and address of the facility, and reason for the rescission request to the NPDES Permitting and Compliance Program. Docusign Envelope ID: 05D2B548-531D-4F66-8C1B-775EE9568B36 Page 3 of 3 Hibernia Recreation Area Compliance Inspection 2024 3 If you have questions or comments about the inspection, this report or the requirements to take corrective action (if applicable), please contact Kevin Fowler at 919-437-0047 or via email at kevin.fowler@deq.nc.gov Sincerely, Vanessa Manuel Water Quality Regional Assistant Supervisor Raleigh Regional Office Attachments: EPA Water Compliance Inspection Report Cc: Laserfische John Abbot (ORC) Docusign Envelope ID: 05D2B548-531D-4F66-8C1B-775EE9568B36 EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0089583 24/08/22 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Hibernia Recreation Area 6254 Satterwhite Point Rd Henderson NC 27537 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 11:00AM 24/08/22 20/10/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// John Wesley Abbott/ORC/252-438-7791/ Other Facility Data 12:30PM 24/08/22 22/03/31 Name, Address of Responsible Official/Title/Phone and Fax Number Jody Reavis,6254 Satterwhite Point Rd Henderson NC 275364099//252-438-7791/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance Records/Reports Self-Monitoring Program Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Kevin Fowler DWR/RRO WQ/919-791-4200/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 08/23/2024 Docusign Envelope ID: 05D2B548-531D-4F66-8C1B-775EE9568B36 8/29/2024 NPDES yr/mo/day 24/08/22 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) A new subsurface system was built/finished in January of 2022. They indicated the new system was put in place due to the old system not performing as well as they wanted. The pipe was cut and the septic tank was crushed in place. The other units and outfall are still in palce but not recieving flow. They indicated that they are trying to have the permit rescinded. NC0089583 17 Page#2 Docusign Envelope ID: 05D2B548-531D-4F66-8C1B-775EE9568B36 Permit:NC0089583 Inspection Date:08/22/2024 Owner - Facility: Inspection Type: Hibernia Recreation Area Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? System is no longer in use. A new subsurface system was finished in January of 2022. They are trying to do process to have permit rescinded. Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain-of-custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Page#3 Docusign Envelope ID: 05D2B548-531D-4F66-8C1B-775EE9568B36 Permit:NC0089583 Inspection Date:08/22/2024 Owner - Facility: Inspection Type: Hibernia Recreation Area Compliance Evaluation Record Keeping Yes No NA NE Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? System not in use. No flow since January of 2021 due to new system being built.Comment: Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? Is septic tank pumped on a schedule? Are pumps or syphons operating properly? Are high and low water alarms operating properly? Septic tank was crushed in place and back filled.Comment: Sand Filters (Low rate)Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? Is the distribution box level and watertight? Is sand filter free of ponding? Is the sand filter effluent re-circulated at a valid ratio? # Is the sand filter surface free of algae or excessive vegetation? # Is the sand filter effluent re-circulated at a valid ratio? (Approximately 3 to 1) Sand filter left in place. No signs of any surfacingComment: Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use? Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? Chlorination tubes still in place but not being used due to no flow.Comment: De-chlorination Yes No NA NE Type of system ?Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? Page#4 Docusign Envelope ID: 05D2B548-531D-4F66-8C1B-775EE9568B36 Permit:NC0089583 Inspection Date:08/22/2024 Owner - Facility: Inspection Type: Hibernia Recreation Area Compliance Evaluation De-chlorination Yes No NA NE # Is de-chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de-chlorinators operational? Number of tubes in use? Dechlorination tubes sitll in place but not being used due to no flow.Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? No sampling done since January 2022.Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Effluent pipe is still in place and is not capped.Comment: Page#5 Docusign Envelope ID: 05D2B548-531D-4F66-8C1B-775EE9568B36 NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY This annual fee is required by the North Carolina Administrative Code. It covers the administrative costs associated with your permit. It is required of any person holding a permit for any time during the annual fee period, regardless of the facility’s operating status. Failure to pay the fee by the due date will subject the permit to revocation. Operating without a valid permit is a violation and is subject to a $10,000 per day fine. If the permit is revoked and you later decide a permit is needed, you must reapply, with the understanding the permit request may be denied due to changes in environmental, regulatory, or modeling conditions. INVOICE Annual Permit Fee Overdue *2024PR002499* Permit Number:NC0089583 Annual Fee Period: Vance County Invoice Date:03/15/2024 Hibernia Recreation Area Due Date:04/14/2024 Annual Fee:$1,150.00 04/01/2024 to 03/31/2025 Bryce Fleming NC Division of Parks & Recreation 1615 Mail Service Ctr Raleigh, NC 27699-1615 2024PR002499Invoice Number: Notes: 1.You may pay either by mail with check/money order OR by electronic payment (eCheck or Credit Card). 2.If payment is by check/money order, please remit payment to: NCDEQ - Division of Water Resources Attn: Animal/Discharge/Non-Discharge Billing 1617 Mail Service Center Raleigh, NC 27699-1617 3.If payment is electronic, please see https://epay.deq.nc.gov/wq-epayments.html to pay electronically. Payments by eCheck will debit your checking account. Credit card transactions will incur a convenience fee. 4.Please include your Permit Number and Invoice Number on all correspondence. 5.A $35.00 processing fee will be charged for returned checks in accordance with North Carolina General Statute 25-3-506. 6.The Department cannot accept checks older than 6 months under Uniform Commercial Code 4-404. 7.Non-Payment of this fee by the payment due date will initiate the permit revocation process. 8.Should you need to update any Owner/Permit/Contact information or have any questions regarding this invoice, please send email to dwqepay@deq.nc.gov or you may also contact the following: - NPDES WW Program Administrative Contact at 919-707-3601 or - Annual Administering and Compliance Fee Coordinator at 919-707-3698 Bryce Fleming NC Division of Parks & Recreation 1615 Mail Service Ctr Raleigh, NC 27699-1615 Invoice Number: (Return This Portion With Check) ANNUAL PERMIT INVOICE Permit Number:NC0089583 Annual Fee Period: Vance County Invoice Date:3/15/2024 Hibernia Recreation Area Due Date:4/14/2024 Annual Fee:$1,150.00 Check Number: 04/01/2024 to 03/31/2025 Overdue *2024PR002499* 2024PR002499 Docusign Envelope ID: 05D2B548-531D-4F66-8C1B-775EE9568B36