Loading...
HomeMy WebLinkAboutNC0025402_Historical information_20081231January 23, 2008 Subject:MAILED Dear Mayor Jones: Inspector Mr. Myrl Wisely of the Raleigh Regional Office of the Division of Water Quality If you have questions concerning this report, please contact me at 919-791-4255. s= Raleigh Regional Office Water Quality Section Attachment cc: Central Files SWP/RRO files pei formed an inspection on 1/22/2008. The help given by Tony Gorham was appreciated. The wastewater plant was in compliance, but one analytical detail must be addressed. Please review the attached inspection checklist. The thermometers used in the influent and effluent sampling refrigerators need to be calibrated against a traceable NIST certified thermometer annually (as do all thermometers used in the laboratory). This was last done in May 2006. phone (919) 791-4200 facsimile (919)788-7159 ^CDLNS:1628 Mail Service Center Raleigh, NC 27699-1628 Customer Service 1-877-623-6748 Compliance Evaluation Inspection Enfield WWTP NPDES Permit No. NC0025402 Halifax County Sincerely, kj A iu MyrPA. Wisely Environmental Chemist Raleigh Regional Office The only concern identified was: Town of Enfield Honorable Mayor Edward Jones PO Box 699 Enfield, NC 27823 receiveci^1/^? I > |L _ Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina iSJPrtrn^aof Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality ^11 IrVT’ EPA NPDES 12LNC0025402 Entry Time/Date Permit Effective Date 05/03/0108/01/2209:55 AMEnfield WWTP Exit Time/Date18270 US Hwy 301 Permit Expiration Date Enfield NC 27823 09/10/3108/01/2211:10 AM Other Facility Data Name, Address of Responsible Offidal/Title/Phone and Fax Number Bobby Davis,PO Box 699 Enfield NC 27823//252-445-3586/2524451019 Records/Reports Sludge Handling Disposal Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Myrl RRO WQ//919-791-4200/ Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page #1 3I United States Environmental Protection Agency Washington, D.C. 20460 yr/mo/day 08/01/22 QA 72 H Contacted No Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Nisely x you’ Signature of Management Q A Reviewer Water Compliance Inspection Report Section A: National Data System Coding (i.e., PCS) J11 Fac Type 20LI Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Flow Measurement Operations & Maintenance Facility Site Review Inspection Type 18EJJ17 Inspector 19EJ Transaction Code 1 LJ 2 U 73l I I74 —Reserved----------------------- 75| I I I I I | I80 Permit ■ Self-Monitoring Program M Laboratory B1 71 u_ _______________________________ ______________________Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Remarks21| I I I I I I I I I I I I I I I I I I I | | | | | | | | | | | | | | | | | | | | | | | | | | |66 Inspection Work Days Facility Self-Monitoring Evaluation Rating 671| 69 70[J Operations & Maintenance Yes No NA NE ■ 0 Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ 0 Judge, and other that are applicable? Comment: Permit Yes No NA NE O ■ (If the present permit expires in 6 months or less). Has the permittee submitted a new application? ■ 0 Is the facility as described in the permit? # Are there any special conditions for the permit?o ■ Is access to the plant site restricted to the general public?■ o ■ Is the inspector granted access to all areas for inspection? Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit?■ □00 ■ □□□Is all required information readily available, complete and current? ■ DOOAre all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs?■ ODD Is the chain-of-custody complete?■ ODD Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters?■ ODD Has the facility submitted its annual compliance report to users and DWQ?■ ODD (If the facility is - or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift?0 0 ■ 0 Is the ORC visitation log available and current?■ DOO Is the ORC certified at grade equal to or higher than the facility classification?■ ODD Is the backup operator certified at one grade less or greater than the facility classification?■ ODD Is a copy of the current NPDES permit available on site?■ ODO Permit: NC0025402 Inspection Date: 01/22/2008 Owner - Facility: Enfield WWTP Inspection Type: Compliance Evaluation Page # 3 Record Keeping Yes No NA NE ■ Facility has copy of previous year's Annual Report on file for review? Effluent Pipe Yes No NA NE ■ Is right of way to the outfall properly maintained? ■ o Are the receiving water free of foam other than trace amounts and other debris? ■ ODOIf effluent (diffuser pipes are required) are they operating properly? Comment: Flow Measurement - Effluent Yes No NA NE ■ □00# Is flow meter used for reporting? ■ ODOIs flow meter calibrated annually? ■ 000Is the flow meter operational? ■ DOO(If units are separated) Does the chart recorder match the flow meter? Comment:Last calibrated 11/28/2007 Aerobic Digester Yes No NA NE ■ ODDIs the capacity adequate? ■ ODDIs the mixing adequate? ■ ODDIs the site free of excessive foaming in the tank? ■ DDD# Is the odor acceptable? ■ DDD# Is tankage available for properly waste sludge? Solids Handling Equipment Yes No NA NE ■ DDDIs the equipment operational? ■ DDDIs the chemical feed equipment operational? ■ DDDIs storage adequate? ■ DDDIs the site free of high level of solids in filtrate from filter presses or vacuum filters? ■ DDDIs the site free of sludge buildup on belts and/or rollers of filter press? ■ DDDIs the site free of excessive moisture in belt filter press sludge cake? ■ DDDThe facility has an approved sludge management plan? Comment: Page #4 Owner - Facility: Enfield WWTP Inspection Type: Compliance Evaluation Permit: NC0025402 Inspection Date: 01/22/2008 Comment: Operator tab in BIMS is blank. The ORC and Backup ORC should be added to this database. Comment: Levels were low, indicating hauling in recent past. Last cell no longer covered by plants. Pump Station - Effluent Yes No NA NE ■ Is the pump wet well free of bypass lines or structures? ■ o 0 Are all pumps present? ■ 0 Are all pumps operable? ■ oAre float controls operable? ■ Is SCADA telemetry available and operational? ■ Is audible and visual alarm available and operational? Comment: Bar Screens Yes No NA NE Type of bar screen oa.Manual b.Mechanical ■ 0Are the bars adequately screening debris? ■ o Is the screen free of excessive debris? ■ Is disposal of screening in compliance? Is the unit in good condition?■ ODD Comment: Grit Removal Yes No NA NE Type of grit removal a.Manual b.Mechanical ■ Is the grit free of excessive organic matter? Is the grit free of excessive odor?■ # Is disposal of grit in compliance?■ o Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater?■ Is the site free of excessive buildup of solids in center well of circular clarifier?■ o ■ o Are weirs level? ■ Is the site free of weir blockage? Is the site free of evidence of short-circuiting?■ o Page #5 Permit: NC0025402 Inspection Date: 01/22/2008 Owner - Facility: Enfield WWTP Inspection Type: Compliance Evaluation Second ary Clarifier Yes No NA NE ■ □00Is scum removal adequate? ■ 000Is the site free of excessive floating sludge? ■ 0 Is the drive unit operational? ■ 0 Is the return rate acceptable (low turbulence)? ■ 0 Is the overflow clear of excessive solids/pin floc? ■ Is the sludge blanket level acceptable? (Approximately 1/iof the sidewall depth) Sludge blanket = 1 ft.Comment: Oxidation Ditches Yes No NA NE ■ 0Are the aerators operational? ■ Are the aerators free of excessive solids build up? ■ 000# Is the foam the proper color for the treatment process? ■ Does the foam cover less than 25% of the basin’s surface? ■ Is the DO level acceptable? ■ o Are settleometer results acceptable (> 30 minutes)? ■ Is the DO level acceptable?(1.0 to 3.0 mg/l) ■ Are settelometer results acceptable?(400 to 800 ml/l in 30 minutes) Comment: Nutrient Removal Yes No NA NE ■ # Is total nitrogen removal required? ■ o # Is total phosphorous removal required? BiologicalType ■ # Is chemical feed required to sustain process? ■ Is nutrient removal process operating properly? Comment: Disinfection-Gas Yes No NA NE ■ 000Are cylinders secured adequately? ■ 000Are cylinders protected from direct sunlight? ■ 000Is there adequate reserve supply of disinfectant? ■ 000Is the level of chlorine residual acceptable? ■ 000Is the contact chamber free of growth, or sludge buildup? Page#6 Owner - Facility: Enfield WWTP Inspection Type: Compliance Evaluation Permit: NC0025402 Inspection Date: 01/22/2008 Disinfection-Gas Yes No NA NE ■ Is there chlorine residual prior to de-chlorination? Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No. 7782-50-5)? ■ If yes, then is there a Risk Management Plan on site?o ■ If yes, then what is the EPA twelve digit ID Number? (1000- ) If yes, then when was the RMP last updated? Comment:Less than 2500 lb chlorine on-site De-chlorination Yes No NA NE Type of system ?Gas ■ Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders?■ # Is de-chlorination substance stored away from chlorine containers?■ Comment: ■ Are the tablets the proper size and type? Are tablet de-chlorinators operational? o ■ Number of tubes in use? Comment: Sta nd by Power Yes No NA NE Is automatically activated standby power available?■ o Is the generator tested by interrupting primary power source?■ 0 Is the generator tested under load?■ ODO Was generator tested & operational during the inspection?o ■ o Do the generator(s) have adequate capacity to operate the entire wastewater site?■ Is there an emergency agreement with a fuel vendor for extended run on back-up power?■ o Is the generator fuel level monitored?■ Yes No NA NE Are field parameters performed by certified personnel or laboratory?■ Are all other parameters(excluding field parameters) performed by a certified lab?■ 0 # Is the facility using a contract lab?■ Page #7 Owner - Facility: Enfield WWTP Inspection Type: Compliance Evaluation Permit: NC0025402 Inspection Date: 01/22/2008 Comment: Generator is run weekly and tested under a load by cutting power monthly. Is capable of running the essential equipment. Laboratory Laboratory Yes No NA NE ■ Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ■ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?o ■ Comment: Influent Sampling Yes No NA NE # Is composite sampling flow proportional?o ■ o Is sample collected above side streams?■ o Is proper volume collected?■ o Is the tubing clean?■ 0 Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)?■ Is sampling performed according to the permit?■ ODO Comment:Sampling is timed, 9x/hour Effluent Sampling Yes No NA NE Is composite sampling flow proportional?■ o Is sample collected below all treatment units?■ ■ Is proper volume collected? Is the tubing clean?■ Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)?■ Is the facility sampling performed as required by the permit (frequency, sampling type representative)?■ Comment: Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? ■ Comment: Page #8 Owner - Facility: Enfield WWTP Inspection Type: Compliance Evaluation Permit: NC0025402 Inspection Date: 01/22/2008 North Carolina December 2, 2008 Subject: Dear Mayor Bishop: Dave Parnell of the Raleigh Regional Office of the Division of Water Quality conducted two I.NPDES Inspection: 1. The current permit 2. 3. Raleigh Regional Office Water Quality Section 1628 Mail Service Center Raleigh, NC 27699-1628 phone (919) 791-4200 facsimile (919)788-7159 Customer Service 1-877-623-6748 Compliance Evaluation Inspections Enfield WWTP NPDES Permit NC0025402 and Stormwater Permit NCG110090 Halifax County & was reissued March 1, 2005 and expires October 31, 2009 Town of Enfield Honorable Mayor Wamie Bishop PO Box 699 Enfield, NC 27823 Michael F. Easley, Governor William G. Ross Jr., Secretary 'tment of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality Below is a list of findings and recommendations developed from the inspections: co >1 O The 1.0 MGD wastewater treatment plant consists of the following units: manual and mechanical bar screens, mechanical grit removal system, influent pump station, influent pumps, aeration unit, dual clarifiers, flow distribution box, chlorine contact tank, dual feed chlorination and dechlorination, aerobic digester, sludge holding basin, sludge loading station, sludge return pump station and effluent pump station. inspections on November 25, 2008, consisting of the NPDES and Stormwater inspections. The assistance of James Pittman, Operator in Responsible Charge, was appreciated. Please review the attached Basinwide Information Management System (BIMS) inspection checklists summarizing the inspections. The inspection began in the treatment plant office. All paperwork was well organized and easily accessible. Discharge Monitoring Reports were reviewed for compliance with permit limits and monitoring requirements. Chain of custody records were available and in order. The facility uses a contract laboratory and sample storage was kept at a temperature of 4.5 degrees Celsius. The effluent composite flow proportional refrigerator temperature was 2.5 degrees Celsius. The influent composite sampler temperature was 2.0 degrees Celsius. Enfield CEI 12.2.08 Page 2 of3 4. 5. 6. 7. 8.The aerobic digester appears to have adequate capacity with acceptable odor. 9. Stormwater Inspection:II. 1. 2.The facility is required to provide and document employee training by the permit. 3.Continue semi-annual qualitative monitoring and document these inspections. 4.All outfalls were inspected and showed no sign of illicit discharges. 11. The effluent pump station appears to be in good operational condition. Pumps and float controls are operable. The effluent composite sample is flow proportional and collected below all treatment units. 10. Standby power is available and was tested and operational during a recent power failure according to Mr. Pittman. The generator has adequate capacity to run the plant, partially, but in a manner to achieve desired results, according to Mr. Pittman. A list of significant spills occurring in the last three years should be included as a part of the Stormwater Pollution Prevention Plan. The disinfection (chlorine) cylinders were secured adequately, but were within 10 feet of the dechlorination cylinders. All of the cylinders were under a shelter but did receive direct late afternoon sunlight. The storage area should be expanded to further separate the cylinders and protect them from direct sunlight. The clarifiers were functioning properly and were free of weir blockages and showed no sign of short-circuiting. The sludge blanket was reported to be 2.5-3 feet, which is in the acceptable range of sidewall depth. The oxidation ditches were being operated properly. Very little foam was noted. The Dissolved Oxygen level was slightly above the acceptable range of 3.0 at 3.06 mg/1. The settelometer results were in the acceptable range at 750 ml/1 in 30 minutes. 12. The effluent pipe is located adjacent to the right of way of a bridge being constructed on US 301. The pipe appears to be unaffected by the construction. The effluent discharging into Fishing Creek appeared clear. The receiving water is free of foam and other debris. Overall maintenance was above average. The manual and mechanical bar screens were in acceptable condition. Grit removal was free of organic matter and excessive odor. Although nutrient removal was not required by the permit, the facility does so in meeting its obligation to the Tar-Pam Association. Enfield CEI 12.2.Page 3 of 3 Attachment cc: Central Files SWP/RRO files Sincerely, Dave Parnell Environmental Specialist Raleigh Regional Office The wastewater treatment plant is considered to be in compliance with the NPDES permit, as well as the general stormwater pemit at the time of these inspections. If you have questions concerning this report, please do not hesitate to contact me at 919-791-4200. EPA NPDES NC0025402 I I | | | | |66 Entry Time/Date Permit Effective Date 05/03/0108/11/2501:00 PMEnfield WWTP 18270 US Hwy 301 Exit Time/Date Permit Expiration Date Enfield NC 27823 09/10/3108/11/2503:00 PM Other Facility Data James Earl Pittman/ORC/252 826-5540/ Name, Address of Responsible Official/Title/Phone and Fax Number Bobby Davis,PO Box 699 Enfield NC 27823//2S2-445-3586/2524451019 Records/Reports Effluent/Receiving Waters (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date David R Parnell RRO WQ//919-791-4260/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. 12l31 yr/mo/day 08/11/25 Contacted No QA 72[nI United States Environmental Protection Agency Washington, D.C. 20460 Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Inspection Work Days 671 I 69 Agency/Office/Phone and Fax Numbers Date Facility Self-Monitoring Evaluation Rating 70U J11 Fac Type 20U Inspection Type 18U Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Flow Measurement Operations & Maintenance Facility Site Review J17 Inspector 19UJ 73l I I74 —Reserved--------------------- 75| I I | | | | I80 Water Compliance Inspection Report Section A: National Data System Coding (i.e., PCS) £ Permit Self-Monitoring Program ■ Laboratory Bi 71 u _____________________________________________Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Transaction Code 11J 2 L±J Remarks 21LLLJ I I I I I I I I I I I I | | | | | | | | | | | | | | | | | | | | | | | | Sludge Handling Disposal fl Storm Water Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page # 1 NPDES yr/mo/day 1 J17NC002540208/11/25 Page #2 12lJ113l Inspection Type 18. .Ill_____________________ Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Record Keeping Yes No NA NE Are records kept and maintained as required by the permit?■ Is all required information readily available, complete and current?■ Are all records maintained for 3 years (lab. reg. required 5 years)?■ o Are analytical results consistent with data reported on DMRs?■ o Is the chain-of-custody complete?■ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses o Transported COCs Are DMRs complete: do they include all permit parameters?■ o Has the facility submitted its annual compliance report to users and DWQ?■ o (If the facility is - or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? ■ Is the ORC visitation log available and current?■ Is the ORC certified at grade equal to or higher than the facility classification?■ 000 ■ 000 ■ 00 0 Facility has copy of previous year's Annual Report on file for review?0 a n ■ Yes No NA NE Are field parameters performed by certified personnel or laboratory?■ DOO Are all other parameters(excluding field parameters) performed by a certified lab?■ ODO # Is the facility using a contract lab?■ 000 ■ n 0 0 0 ■ Incubator (BOD) set to 20.0 degrees Celsius +/-1.0 degrees? ■ Comment:Sample storage temp @ 4.5 degrees. Permit Yes No NA NE Page #3 Comment: Annual report on bulletin board at Town Hall. Laboratory # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius*/- 0.2 degrees? Permit: NC0025402 Inspection Date: 11/25/2008 Owner - Facility: Enfield WWTP Inspection Type: Compliance Evaluation Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Permit Yes No NA NE ■ (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit?■ # Are there any special conditions for the permit? ■ Is access to the plant site restricted to the general public?■ o ■ Is the inspector granted access to all areas for inspection? Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping?■ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ Judge, and other that are applicable? Comment: Upstream / Downstream Sampling Yes No NA NE Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris?■ o Is the screen free of excessive debris?■ Is disposal of screening in compliance?■ 0 Is the unit in good condition?■ Comment: Grit Removal Yes No NA NE Type of grit removal a.Manual b.Mechanical Is the grit free of excessive organic matter?■ o Is the grit free of excessive odor?■ ODO # Is disposal of grit in compliance?■ o Page #4 Permit: NC0025402 Inspection Date: 11/25/2008 Owner - Facility: Enfield WWTP Inspection Type: Compliance Evaluation Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? ■ O Comment: Grit Removal Yes No NA NE Comment: Influent Sampling Yes No NA NE # Is composite sampling flow proportional? ■ Is sample collected above side streams? ■ 0 Is proper volume collected?■ ODO Is the tubing clean?■ 0 # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)?■ 0 Is sampling performed according to the permit?■ Yes No NA NE Are the aerators operational?■ Are the aerators free of excessive solids build up?■ # Is the foam the proper color for the treatment process?■ Does the foam cover less than 25% of the basin’s surface?■ Is the DO level acceptable?■ 0 Are settleometer results acceptable (> 30 minutes)?■ Is the DO level acceptable?(1.0 to 3.0 mg/l)■ 0 Are settelometer results acceptable?(400 to 800 ml/l in 30 minutes)■ Comment: Nutrient Removal Yes No NA NE # Is total nitrogen removal required? ■ O # Is total phosphorous removal required? ■ o Type # Is chemical feed required to sustain process? ■ Is nutrient removal process operating properly?■ Comment: Yes No NA NE Is the clarifier free of black and odorous wastewater?■ Is the site free of excessive buildup of solids in center well of circular clarifier?■ Are weirs level?■ 0 Page #5 Comment: Composite sampling is timed. Oxidation Ditches Permit: NC0025402 Inspection Date: 11/25/2008 Owner - Facility: Enfield WWTP Inspection Type: Compliance Evaluation Nutrient removal is not required but they do it, according to James Pittman. Secondary Clarifier Secondary Clarifier Yes No NA NE Is the site free of weir blockage?■ Is the site free of evidence of short-circuiting?■ Is scum removal adequate?■ Is the site free of excessive floating sludge?■ Is the drive unit operational?■ Is the return rate acceptable (low turbulence)?■ o Is the overflow clear of excessive solids/pin floc?■ ■ Aerobic Digester Yes No NA NE Is the capacity adequate?■ o Is the mixing adequate? ■ Is the site free of excessive foaming in the tank? ■ # Is the odor acceptable?■ ODO # Is tankage available for properly waste sludge?■ o Comment: Disinfection-Gas Yes No NA NE Are cylinders secured adequately?■ Are cylinders protected from direct sunlight? ■ Is there adequate reserve supply of disinfectant?■ o Is the level of chlorine residual acceptable?■ ODO Is the contact chamber free of growth, or sludge buildup?■ □□□ Is there chlorine residual prior to de-chlorination?■ o Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No. 7782-50-5)? ■ o If yes, then is there a Risk Management Plan on site? o ■ If yes, then what is the EPA twelve digit ID Number? (1000-..) If yes, then when was the RMP last updated? There is ample shelter although sunlight does hit them during late De-chlorination Yes No NA NE Page #6 Comment: afternoon. Permit: NC0025402 Inspection Date: 11/25/2008 Owner - Facility: Enfield WWTP Inspection Type: Compliance Evaluation Is the sludge blanket level acceptable? (Approximately !4 of the sidewall depth) Comment: De-chlorination Yes No NA NE Type of system ?Gas Is the feed ratio proportional to chlorine amount (1 to 1)?■ o Is storage appropriate for cylinders?■ □00 # Is de-chlorination substance stored away from chlorine containers?■ □00 Are the tablets the proper size and type?DOiO Comment: Sulphur Oxide tanks are about 8* from chlorine tanks. Are tablet de-chlorinators operational?0 0 ■ n Number of tubes in use? Comment: Standby Power Yes No NA NE Is automatically activated standby power available?■ ODD Is the generator tested by interrupting primary power source?■ 000 Is the generator tested under load?■ OOD Was generator tested & operational during the inspection? □□■ Do the generator(s) have adequate capacity to operate the entire wastewater site? □■O Is there an emergency agreement with a fuel vendor for extended run on back-up power?■ 000 Is the generator fuel level monitored?■ DOO Generators have enough capacity to run the plant, but not all parts of the Pump Station - Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures?■ DOO Are all pumps present?■ DOO ■ 000Are all pumps operable? Are float controls operable?■ 000 Is SCADA telemetry available and operational?O 0 ■ 0 Is audible and visual alarm available and operational?0 0 ■ 0 Comment: Effluen^Sampling Yes No NA NE Is composite sampling flow proportional?■ ODO ■ ODOIs sample collected below all treatment units? Page #7 Comment: plant. Owner - Facility: Enfield WWTP Inspection Type: Compliance Evaluation Permit: NC0025402 inspection Date: 11/25/2008 Effluent Sampling Yes No NA NE Is proper volume collected?■ o Is the tubing clean?■ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)?■ ■ O Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting?■ o Is flow meter calibrated annually?■ o Is the flow meter operational?■ (If units are separated) Does the chart recorder match the flow meter?■ o Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained?■ o Are the receiving water free of foam other than trace amounts and other debris?■ ■ o Page #8 If effluent (diffuser pipes are required) are they operating properly? Comment: Permit: NC0025402 Inspection Date: 11/25/2008 Owner - Facility: Enfield WWTP Inspection Type: Compliance Evaluation Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: Compliance Inspection Report Permit: NCG110090 Effective: 06/01/08 Expiration: 05/31/13 Owner: Town of Enfield SOC:Effective:Expiration: Enfield NC 27823 Contact Person: Warnie Bishop Title: Mayor Phone: 252-445-3146 Ext.24 Directions to Facility: System Classifications: Certification:Phone: On-Site Representative(s): Related Permits: Inspection Date: 11/25/2008 Entry Time: 03:00 PM Exit Time: 03:45 PM Phone: 919-791-4260 Reason for Inspection:Routine (See attachment summary) Page: 1 Question Areas: !■ Storm Water Primary ORC: Secondary ORC(s): County: Halifax Region: Raleigh Facility: Enfield WWTP 18270 US Hwy 301 Primary Inspector: David R Parnell Secondary Inspector(s): Inspection Type: Stormwater Permit Inspection Type: Municipal WWTP > 1MGD, Stormwater Discharge, COG Facility Status: ■ Compliant O Not Compliant Permit: NCG110090 Owner - Facility: Town of Enfield Inspection Date: 11/25/2008 Inspection Type: Stormwater Reason for Visit: Routine Inspection Summary: Page: 2 Permit: NCG110090 Owner - Facility: Town of Enfield Inspection Date: 11/25/2008 Inspection Type: Stormwater Reason for Visit: Routine StorrnwaterPollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan?■ ODD # Does the Plan include a General Location (USGS) map?■ o # Does the Plan include a “Narrative Description of Practices"?■ ■ o ■ # Has the facility evaluated feasible alternatives to current practices? ■ o # Does the facility provide all necessary secondary containment?■ o # Does the Plan include a BMP summary?■ # Does the Plan include a Spill Prevention and Response Plan (SPRP)?■ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan?■ o # Does the facility provide and document Employee Training? ■OO # Does the Plan include a list of Responsible Party(s)?■ OOD # Is the Plan reviewed and updated annually?■ 000 # Does the Plan include a Stormwater Facility Inspection Program?■ ODO Has the Stormwater Pollution Prevention Plan been implemented?■ DOO Yes No NA NE ■ ODD Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring?O 0 ■ 0 # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas?0 0 ■ o Comment: Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site?■ ODD # Were all outfalls observed during the inspection?■ ODD # If the facility has representative outfall status, is it properly documented by the Division?0 0 ■ 0 # Has the facility evaluated all illicit (non stormwater) discharges?■ ODD Comment: Page: 3 Has the facility conducted its Qualitative Monitoring semi-annually? Comment: # Does the Plan include a detailed site map including outfall locations and drainage areas? # Does the Plan include a list of significant spills occurring during the past 3 years? Comment. List is not contained in the plan, but listed elsewhere. No documented employee training for stormwater. QuaHtative Monitoring August 5, 2008 Subject: Dear Mayor Bishop: Date Limit Value Reported Value Limit Type 05/19/08 9 su 9.3 su Daily Maximum Exceeded If you have any questions regarding this notice, please contact xxxxx at 919-791-4200. One NorthCarolina Naturally Raleigh Regional Office Surface Water Protection Danny Smith Surface Water Protection Supervisor Raleigh Regional Office phone(919) 791-4200 facsimile (919) 788-7159 Ms. Wamie Bishop Town of Enfield PO Box 699 Enfield NC 27823 1628 Mail Service Center Raleigh, NC 27699-1628 xc: Central Files RRO SWP files NOTICE OF VIOLATION Permit No. NC0025402 Enfield WWTP Case No. NOV-2008-LV-0369 Halifax County Customer Service 1-877-623-6748 CERTIFIED MAIL 7006 2150 0000 3312 0080 RETURN RECEIPT REQUESTED pH Remedial actions should be taken to correct this problem. It is the duty of every permitted facility to meet permit limits. We urge you to avoid future occurrences. By doing so, you will prevent further action by the State regarding the problems this month while protecting our lakes, rivers and streams. The Division of Water Quality has reviewed Enfield WWTP's monitoring report for May 2008 and we noted the following violation(s) had been reported:_________ Parameter Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality 0^$/ 2?1 111 I ■« NCDEM Michael F. Easley, Governor February 29, 2008 Dear Permittee: > 2. An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper You are receiving this advance notice because your facility has a permitted flow at or above 1 MGD, or the facility receives industrial [pretreatment] wastewater. If either of these criteria no longer applies, contact the NPDES Unit before submitting a renewal application. Federal (40 CFR 122) and state (15A NCAC 2H.0105(e)) regulations require that permit renewal applications be filed at least 180 days prior to expiration of the current permit. Your renewal application is due to the Division postmarked no later than May 4, 2009. Failure to apply for renewal by the appropriate deadline may result in a civil penalty assessment or other enforcement activity at the discretion of the Director. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 512 North Salisbury Street, Raleigh, North Carolina 27604 Phone: 919 733-5083, extension 511 / FAX 919 733-0719/charles.weaver@ncmail.net > > > > William G. Ross, Jr., Secretary Coleen H. Sullins, Director Bobby Davis Town of Enfield P.O. Box 699 Enfield, NC 27823-0699 SUBJECT: Advance Notice of Renewal Application Requirements Permit NC0025402 Enfield WWTP Your NPDES permit for a municipally owned/operated WWTP expires on October 31, 2009. This notice is being sent to explain the requirements for your permit renewal application. The U.S. EPA revised and expanded the application requirements for municipal permits, effective August 1, 2001. EPA form 2A is attached to this Notice, and must be used for your permit renewal application. The new application requirements mandate additional effluent testing: 1. Conduct three Priority Pollutant Analyses (PPAs) and submit results with your renewal application. Collect samples for the PPAs in conjunction with sampling for your current quarterly toxicity test. The new PPA requirements differ from previous versions. Each PPA must include: Analyses for all total recoverable metals listed in Part D of form 2A. This includes metals that are not normally monitored through your NPDES permit. Analyses for total phenolic compounds and hardness. Analyses for all of the volatile organic compounds listed in Part D. Analyses for all of the acid-extractable compounds listed in Part D. Analyses for all base-neutral compounds listed in Part D. Analyses for Total Mercury must be performed using EPA Method 1631. Conduct four toxicity tests for an organism other than Ceriodaphnia and submit results with your renewal application. The tests should be conducted quarterly, with samples collected on the same day as your current toxicity test. Call the Aquatic Toxicology Unit at (919) 733-2136 for guidance in conducting the additional tests. _ _OneNorthCarolinaNaturally NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Sincerely, o o o o If any wastewater discharge will occur after the current permit expires, this NPDES permit must be renewed. Discharge of wastewater without a valid permit would violate Federal and North Carolina law. Unpermitted discharges of wastewater could result in assessment of civil penalties of up to $25,000 per day. The pollutant and toxicity analyses described above must accompany your permit renewal application, or any major permit modification request. The Division cannot draft your permit without the additional data. Any data submitted cannot be over 4 l/2 years old, and must account for seasonal variation (samples cannot be collected during the same season each year if collected over multiple years). PLEASE NOTE; If your existing permit contains a requirement for annual PPAs, additional PPAs are not required [provided you have conducted at least 3 scans prior to submitting your application]. Use the checklist below to complete your renewal package. The checklist identifies the items you must submit with the permit renewal application. If all wastewater discharge has ceased at this facility and you wish to rescind this permit, please contact me. My telephone number, fax number and e-mail address are listed at the bottom of the previous page. tice for Permit NC0025402 Halifax County Page 2 Send the completed renewal package to: Mrs. Dina Sprinkle NC DENR / DWQ / Point Source Branch 1617 Mail Service Center Raleigh, NC 27699-1617 cc: Central Files Raleigh Regional Office, Water Quality Section NPDES File Charles H. Weaver, Jr. NPDES Unit The following items are REQUIRED for all renewal packages: A cover letter requesting renewal of the permit and documenting any changes at the facility since issuance of the last permit. Submit one signed original and two copies. The completed EPA Form 2A application (copy attached), signed by the permittee or an Authorized Representative. Submit one signed original and two copies. If an Authorized Representative (such as a consulting engineer or environmental consultant) prepares the renewal package, written documentation must be provided showing the authority delegated to the Authorized Representative (see Part II.B.ll.b of the existing NPDES permit). A narrative description of the sludge management plan for the facility. Describe how sludge (or other solids) generated during wastewater treatment are handled and disposed. If your facility has no such plan (or the permitted facility does not generate any solids), explain this in writing. Submit one signed original and two copies. This information can be included in the cover letter. me'