Loading...
HomeMy WebLinkAboutSW3240802_Supplement-EZ Form_20240820 SUPPLEMENT-EZ COVER PAGE PRQCT INFORMATION 1 Project Name - Luna Estates Subdivision 2 Project Area(ac) _ 28.96 - - 3 Coastal Wetland Area(ac) _ 0 -- 4 Surface Water Area(ac) - _ 0 5 Is this project High or Low Density? _ ,_ High 6 Does this project use an off-site SCM? No ,_ ^ COMPLIANCE WITH 02H.1003(4) -1 7 Width of vegetated setbacks provided(feet) 80 j 8 Will the vegetated setback remain vegetated? es 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003 4)c-d? _ es 10 Is streambank stabilization proposed on this project? .No NUMBER AND TYPE OF SOW: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond ' - _ 14 Stormwater Wetland 15 Permeable Pavement _ 16 Sand Filter - , 17 Rainwater Harvesting(RWH) - -- 18 Green Roof • 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond _ - - 23 StormFilter 24 Silva Cell - - _- --_- . - 25 I Bayfilter _--".- _. __- _ ._- . - - _ 26 IFilterra IFORMS LOADED DESIGNER CERTIFICATION 27 1 Name and Title: Zachary Gase.Project Engineer- 28 'Organization: McKim&Creed 29 Street address: _ _ 8020 Tower Point Drive 30 City,State,Zip: Charlotte,NC 28227 31 Phone number(s): _ 704-841-2588 32 Email: zgaset�mckimcreed.com Certification Statement I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision.that the information provided in the form is.to the best of my knowledge and belief,true,accurate,and complete:and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer ``,ittltlltlflNlt, 058145 = nature of De igner ,f-f,•••NGINEER•.•5c.. 9 tit r iZ if Seal Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so,number of drainage areas/SCMs _ 1 3 Does this project have low density areas? _ No 4 If so,number of low density drainage areas _ 0 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 4 Type of SCM Wet Pond 5 Total drainage area(sq ft) 1054316 6 Onsite drainage area(sq ft) 1054316 7 Offsite drainage area(sq ft) 0 8 Total BUA in project(sq ft) sf N/A New BUA on subdivided lots(subject to 9 permitting)(sq ft) 114782 sf 114782 sf New BUA not on subdivided lots(subject to 10 permitting)(sf) 88651 sf 88651 sf 11 Offsite BUA(sq ft) - - 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) --Sidewalk(sq ft) 13283 sf 13283 sf -Roof(sgft) --Roadway(sq ft) 75368 sf 75368 sf -Future(sq ft) sf -Other,please specify in the comment box below(sq ft) -New infiltrating permeable pavement on 13 subdivided lots(sq ft) -New infiltrating permeable pavement not on 14 subdivided lots(sq ft) - - Existing BUA that will remain(not subject to 15 permitting)(sq ft) - - 16 Existing BUA that is already permitted(sq ft) - - 17 Existing BUA that will be removed(sq ft) 18 Percent BUA 0% 19% 19 Design storm(inches) 1.5 in 1.0 in 20 Design volume of SCM(cu ft) 40155 cf 21 Calculation method for design volume SA/DA Method ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): Design volumes listed above are the PROVIDED design volumes,not minimum required design volumes. WET POND I 1 Drainage area number 1 I 2 Minimum required treatment volume(Cu ft) 37690 cf GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM(H:V)? 3:1 6 Does the SCM have retaining walls,gabion walls or other engineered No side slopes? 7 Are the inlets,outlets,and receiving stream protected from erosion Yes (10-year storm)? 8 Is there an overflow or bypass for inflow volume in excess of the Yes design volume? 9 What is the method for dewatering the SCM for maintenance? Pump(preferred) 10 If applicable,will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC(8)? Yes 12 Does the drainage easement comply with General MDC(9)? _ Yes If the SCM is on a single family lot,does(will?)the plat comply with 13 Yes General MDC(10)? 14 Is there an O&M Agreement that complies with General MDC(11)? Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM desi ned b an NC licensed rofessional? Yes WET POND MDC FROM 02H.1053 18 Sizing method used SA/DA 19 Has a stage/storage table been provided in the calculations? Yes 20 Elevation of the excavated main pool depth(bottom of sediment 692.00 removal)(fmsl) 21 Elevation of the main pool bottom(top of sediment removal)(fmsl) 692.50 22 Elevation of the bottom of the vegetated shelf(fmsl) 695.50 23 Elevation of the permanent pool(fmsl) 696.00 24 Elevation of the top of the vegetated shelf(fmsl) 696.50 25 Elevation of the temporary pool(fmsl) 698.00 26 Surface area of the main permanent pool(square feet) 19197 27 Volume of the main permanent pool(cubic feet) 57184 cf 28 Average depth of the main pool(feet) 3.10 ft 29 Average depth equation used Equation 2 30 If using equation 3,main pool perimeter(feet) - 31 If using equation 3,width of submerged veg.shelf(feet) - 32 Volume of the forebay(cubic feet) 8653 cf 33 Is this 15-20%of the volume in the main pool? Yes 34 Clean-out depth for forebay(inches) 30 in 35 Design volume of SCM(cu ft) 40155 cf 36 Is the outlet an orifice or a weir? Orifice 37 If orifice,orifice diameter(inches) 3 in 38 If weir,weir height(inches) - 39 If weir,weir length(inches) - 40 Drawdown time for the temporary pool(days) 2.41 41 Are the inlet(s)and outlet located in a manner that avoids short- Yes circuiting? 42 Are berms or baffles provided to improve the flow path? Yes 43 Depth of forebay at entrance(inches) 36 in 44 Depth of forebay at exit(inches) 30 in 45 Does water flow out of the forebay in a non-erosive manner? Yes 46 Width of the vegetated shelf(feet) 6 ft 47 Slope of vegetated shelf(H:V) 6:1 48 Does the orifice drawdown from below the top surface of the Yes permanent pool? 49 Does the pond minimize impacts to the receiving channel from the 1- Yes yr,24-hr storm? 50 Are fountains proposed?(If Y,please provide documentation that No MDC(9)is met.) 51 Is a trash rack or other device provided to protect the outlet system? Yes 52 Are the dam and embankment planted in non-clumping turf grass? Yes 53 Species of turf that will be used on the dam and embankment Fescue 54 Has a planting plan been provided for the vegetated shelf? Yes ADDITIONAL INFORMATION 55 Please use this space to provide any additional information about the wet pond(s): 2