Loading...
HomeMy WebLinkAboutWQ0023634_Monitoring - 06-2024_20240731Monitoring Report Submittal Permit Number#* Name of Facility:* Month:* June WQ0023634 Waterside Villages WWTP Report Information Type * NDMR, NDAR-1, NDAR-2, NDMLR Confirmation Email Address: Name of Submitter: * Signature: Date of submittal: Initial Review Year:* 2024 Upload Document* Waterside Villages DMR.pdf 4.58MB PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). rod.holley@currituckcountync.gov Rod Holley Reviewer: Wanda.Gerald 7/31 /2024 This will be filled in automatically Is the project number correct?* WQ0023634 Is the monitoring report accepted?* Yes No Regional Office* Washington Reviewer: _anonymous Review Date: 8/12/2024 FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page of Permit No.: WQ0023634 Facility Name: Waterside Villages WWTP County: Currituck Month: June Year: 2024 PPI: 001 Flow Measuring Point: ❑ Influent 2 Effluent ❑ No flow generated Parameter Monitoring Point: ❑ Influent P Effluent ❑ Groundwater Lowering ❑ Surface Water Parameter Code 0. 60050 00310 00940 31616 00610 00620 00600 00400 70300 00530 50060 00625 00665 > 'i aE U H O E 2 i`� Q O � O LL LO m a o L U E � �w LL O U co C E Q - Z a)> `o I- =+ z x N gyp° F N (n o m 'o w :°d° ~ 0 (n m O C o F- y L �U L c d 'o°o F .� YZ p c�oa O ii 24-hr hrs GPD mg/L mg/L #/100 mL mg/L mg/L mg/L su mg/L mg/L mg/L mg/L mg/L 1 11,760 2 11,760 3 8:00 7 8,549 6.97 1.22 4 10:00 5 7,203 7.2 1.3 5 10:00 5 11,846 7.18 1.33 6 9:45 5 9,012 6.87 1.28 7 9:30 5 10,015 7.24 1.19 8 10,015 9 10,015 10 9:30 5 9,447 7.22 1.44 11 9:30 5 9,819 2 38 1.5 0.94 8.6 7.18 <10 1.41 7.7 1.55 12 9:30 5 9,483 7.03 1.49 13 7:30 3 11,203 6.89 1.77 141 10:30 4 11,003 7.08 1.23 151 11,003 16 11,003 17 1:00 3 7,805 7.11 0.81 18 11:00 5 8,617 7.08 1.78 19 10:00 6 10,061 3 1 1.3 0.38 3.7 7.16 7.3 1.75 3.1 0.37 20 10:00 5 11,491 7.13 2.11 21 9:30 6 11,023 7.15 2.3 22 11,023 23 11,023 24 10:00 5 15,108 6.73 1.56 25 10:00 5 91387 7.24 1.47 26 10:00 6 10,236 7.04 1 A9 27 9:30 6 1 16,536 7.34 2.02 28 12:00 4 16,494 7.26 1.75 29 16,495 30 16,494 31 Average: 11,164 2.50 6.16 1.40 0.66 6.15 3.65 1.54 5.40 0.96 Daily Maximum: 16,536 3.00 38.00 1.50 0.94 8.60 7.34 10.00 2,30 7.70 1.55 Daily Minimum: 7,203 2.00 1.00 1.30 0.38 3.70 6.73 7.30 0.81 3.10 0.37 Sampling Type: Recorder Composite Composite Grab Composite Composite Composite Grab Composite Composite Monthly Limit: 120,000 10 14 4 10 20 Daily Limit: 43 1 1 6-9 Sample Frequency: Continuous 2 x Month 3 x Year 2 x Month 2 x Month 1 2 x Month 1 2 x Month 5 x Week 3 x Year 2 x Month FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page of Permit No.: WQ0023634 Facility Name: Waterside Villages WWTP County: Currituck Month: June Year: 2024 PPI: 002 Flow Measuring Point: ❑ Influent ❑ Effluent ❑ No flow generated Parameter Monitoring Point: ❑ influent ❑ Effluent R) Groundwater Lowering ❑ Surface Water Parameter Code —► 31616 01045 01055 00610 00620 00600 00400 00665 00625 0 @ ` N Ci f" O y 4f P X O O O v 0 U. O U O d V1 t0 = f6 O E Q N Z w F- :t Z _ Q' H 7 L H 0 a = „s0 � ^ O Y Z 24-hr hrs #/100 mL mg/L mg/L mg/L mg/L mg/L su mg/L mg/L 1 2 3 8:00 7 4 10:00 5 5 10:00 5 6 9:45 5 7 1 9:30 5 8 9 10 9:30 5 11 9:30 5 <1 1.89 2.4 (0 A -i <0.5 12 9:30 5 13 7:30 3 141 10:30 4 15 16 17 1:00 3 18 11:00 5 19 10:00 6 201 10:00 5 21 9:30 6 22 23 24 10:00 5 25 10:00 5 26 1 o:00 6 27 9:30 6 28 12:00 4 29 30 31 Average: 1.89 2.40 0.00 Daily Maximum: 1.89 2.40 0.50 Daily Minimum: 1.89 2.40 1 0.50 Sampling Type: Grab Grab Grab Grab Grab Grab Grab Grab Monthly Limit: Daily Limit: Sample Frequency:1 Monthly 3 x Year 3 x Year 3 x Year 3 x Year Monthly Monthly 3 x Year FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page of Sampling Person(s) Certified Laboratories Name: Rod Holley Name: Enviro Chem Name: Edward Penwell Name: Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? ❑ Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Rod Holley Permittee: County of Currituck Certification No.: 1012915 Signing Official: Rod Holley Grade: WW4 Phone Number: 2522326065 Signing Officials Title: County Superintendent Has the ORC changed since the previous NDMR? ❑ Yes E No Phone Number: 2522326065 Permit Expiration: 11/30/2030 G 7/31 /2024 7/31 /2024 Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Quality Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDAR-2 08-11 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page Permit No.: WQ0023634 Facility Name: Waterside Villages WWTP County: Currituck Month: June Year: 2024 Did infiltration occur at Site Name: 1 Site Name: 2 Site Name: Site Name: this facility? Area (acres): 0.5 Area (acres): 0.5 Area (acres): Area (acres): ❑ YES ❑ NO Rate (GPDlft2): 1 4 Rate (GPD/ft2): 1.4 Rate (GPD/ft2): Rate (GPD/ft): Weather Freeboard Site Infiltrated? O YES ❑ No Site Infiltrated? ❑O YES ❑ No Site Infiltrated? ❑ YES ❑ NO Site Infiltrated? ❑ YES ❑ No R •D U d t 5 d y i Q' E H C 0 :° Q Cf d a Cl y 2 2 .2 Q' (0 Q l0 v "' 0.0 M � 0 �, M a Q ❑ l0 U& v y •p E D 7 n O Q. i 0 NCL °' f0 E F- C _ 01 -'` �_ m D ❑ 0 J 0 0 0 ,O M O C ` y LL N m N 'a E °' 3 a O Q i Q y °' N E_ _ F- „ C CI -'' 5 M 'D ❑ 0 O J C O O M 0 N d y LL M o0 y -O E D 3 a O O. .�+ Q N °' m E �- F_ = w C O) -'' C m M ❑ O J a C 0 0 •0 U) N G �1 N LL. m N 'O E d 7 a O O_ Q o °' N E� F „' C rn -'' E -0 m ❑ O J C 0 0 � N N d y LL N ro °F in ft ft gal min GPDlft2 ft gal min GPD/ft2 ft gal min GPDlft2 ft gal min GPD/ftZ ft 1 5,880 0.27 5,880 0.27 2 5,880 0.27 5,880 0.27 3 CL 74 1 4,275 0.20 4,275 0.20 4 CL 79 0 3,602 0.17 3,602 0.17 5 CL 78 1 5,923 0.27 5,923 0.27 6 1 PC 1 81 0 4,506 0.21 4,506 0.21 7 C 80 0.5 5,008 0.23 5,008 0.23 8 5,008 0.23 5,008 0.23 9 5,008 0.23 5,008 0.23 10 C 74 1 4,724 0.22 4,724 0.22 11 C 73 0 4,910 0.23 4,910 0.23 121 C 75 0 4,742 0.22 4,742 0.22 131 C 73 0 5,602 0.26 5,602 0.26 14 C 77 0 5,502 0.25 5,502 0.25 15 5,502 0.25 5,502 0.25 16 5,502 0.25 5,502 0.25 17 C 80 0 3,903 0.18 3,903 0.18 18 C 8o 0 4,309 0.20 4,309 0.20 19 C 81 0 5,031 0.23 5,031 0.23 20 C 81 0 5,746 0.26 5,746 0.26 21 C 81 0 5,512 0,25 5,512 0.25 22 5,512 0.25 5,512 0.25 23 5,512 0.25 5,512 0.25 241 PC 81 0 7,554 0.35 7,554 0.35 25 PC 80 0 4,694 0.22 4,694 0.22 26 C 85 0 5,118 0.23 5,118 0.23 27 CL 76 1 8,268 0.38 8,268 0.38 28 C 81 0 5,247 0.24 1 5,247 0.24 29 5,247 0.24 5,247 0.24 30 5,247 0.24 5,247 0.24 31 MonthlyLoading (GPDlft2): -.. -' 0.24 0.24 '. " .` d r:` r #DIV/0! , ., #DIV/0! Year to Date LoadingGPDlft2 4.73 �N 4.73 r , r r' FORM: NDAR-2 08-11 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page of Did the application rates exceed the limits in Attachment B of your permit? ❑ Compliant ❑ Non -Compliant If not a basin, were the sites kept free of vegetation and raked? E Compliant ❑ Non -Compliant If not a basin, were there any instances of effluent ponding in or runoff from the sites? P Compliant ❑ Non -Compliant If a basin, were there any instances of breakout from the berms? M Compliant ❑ Non -Compliant Was the onsite automatically activated standby power source tested and operational? ❑ Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. IOperator in Responsible Charge (ORC) Certification 11 Permittee Certification ORC: Rod Holley Permittee: County of Currituck Certification No.: 1012915 Signing Official: Rod Holley Grade: WW4 Phone Number: 2522326065 Signing Officials Title: County Superintendent Has the ORC changed since the previous NDAR-2? ❑ Yes El No Phone Number: 2522326065 Permit Exp.: 11/30/30 )LO 7/31 /24 a JYZ,7/31 /24 ignature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Quality Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617