Loading...
HomeMy WebLinkAboutSW6130203_Supplement-EZ Form_20240423 (2) INFILTRATION SYSTEM 1 Drainage area number 1 2 Minimum re wired treatment volume cu ft 25444 cf GENERAL MDC FROM 02H.1050 3 'Is the SCM sized to treat the SW from all surfaces at build-out? i Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM(H:V or enter"Vertical"for trenches)? 3:1 6 Does the SCM have retaining walls,gabion walls or other engineered side sloes? No 7 lAre the inlets,outlets. and receiving stream protected from erosion (10-year storm)? Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes 9 What is the method for dewatering the SCM for maintenance? Pump(preferred) 10 If applicable,will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC(8)• ? Yes 12 Does the drainage easement comply with General MDC(9)? Yes 13 'If the SCM is on a single family lot,does(will?)the plat comply with General MDC 10? N/A 14 Is there an O&M Agreement that complies with General MDC(11)? Yes 15 11s there an O&M Plan that complies with General MDC(12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? Yes INFILTRATION SYSTEM MDC FROM 02H.1051 18 Proposed slope of the subgrade surface(%) 0% 19 Are terraces or baffles provided? No 20 Type of pretreatment: Forebay (Soils Data 21 Was the soil investigated in the footprint and at the elevation of the infiltration system? Yes 22 SHWT elevation(fmsl) <414 23 Depth to SHWT per soils report(in) < 124 24 Ground elevation at boring in soils report(fmsl) 424.30 25 Is a detailed hydrogeologic study attached if the separation is between 1 and 2 feet? N/A . 26 Soil infiltration rate(in/hr) 0.91 27 'Factor of safety(FS) (2 is recommended): 2.00 Elevations 29 Bottom elevation(fmsl) 420.00 30 Storage elevation(fmsl) _ 422.ft 31 Bypass elevation(fmsl) 422 ft For Basins Only 32 Bottom surface area(ft2) _ 11373 ft 33 Storage elevation surface area(ft2) 14102.ft For Trenches Only 34 Len th(ft) 35 'Width(ft) 36 Perforated pipe diameter,if applicable(inches) 37 Number of laterals 38 Total len th of perforated piping 39 Stone type,if applicable _40 Stone porosity(%) 41 Is stone free of fines? 42 Is the stone wrapped in geotextile fabric? 43 Has at least one inspection port been provided? I Volumes/Drawdown 44 Design volume of SCM(cu ft) 25444 cf 45 Time to draw down(hours) 72 hrs ADDITIONAL INFORMATION 46 Please use this space to provide any additional information about the infiltration system(s): Infiltration 1 1:13 PM 4/23/2024