Loading...
HomeMy WebLinkAboutSW6231204_Design Calculations_20240725 OUTLET PROTECTION DATE DESIGN PHASE DESIGN 09-14-21 PRELIM / / PROJECT NAME PROJECT NO CONSTR / X / Starz Gas Station 1754 REVISION / X / LOCATION BY RECORD / X / Hoke County, North Carolina CJP OTHER / X / CHECKED BY (SPECIFY) CSB Storm Outlet Structure FES No.= PIPE 1 OUT Q1o/Qfull = 0.91 Pipe Dia= 24 in V/Vfull = 1.13 Q10= 15.39 cfs V= 6.1 fps Qfull = 16.92 cfs Vfull = 5.41 fps From Fig. 8.06.b.1: Zone = 2 From Fig. 8.06.b.2: D5o = 8 in DMAX = 12 in Riprap Class = B s Apron Thickness = 18 in 3 Apron Length 12.0 ft Apron Width @ Outlet = 6 ft Apron Width @ End = 14.0 ft Length 1754 Storm System.xlsx LATEST REVISION:5/23/2024 6:12 AM PAGE 1 OF 1 OUTLET PROTECTION DATE DESIGN PHASE DESIGN 09-14-21 PRELIM / / PROJECT NAME PROJECT NO CONSTR / X / Starz Gas Station 1754 REVISION / / LOCATION BY RECORD / / Hoke County, North Carolina CJP OTHER / / CHECKED BY (SPECIFY) CSB Storm Outlet Structure FES No.= PO 34 Q1o/Qfull = 0.31 Pipe Dia= 15 in V/Vfull = 0.87 Q10= 1.44 cfs V= 3.2 fps Qfull = 4.57 cfs Vfull = 3.72 fps From Fig. 8.06.b.1: Zone = 2 From Fig. 8.06.b.2: D5o = 8 in I DMAX = 12 in Riprap Class = B s Apron Thickness = 18 in 3 Apron Length = 7.5 ft Apron Width @ Outlet = 3.75 ft Apron Width @ End = 8.8 ft Length 1754 Storm System.xlsx LATEST REVISION:5/23/2024 6:17 AM PAGE 1 OF 1 Storm Outlet Structure FES No.= PO 35 Q1o/Qfull = 0.74 Pipe Dia= 15 in V/Vfull = 1.09 Q10= 3.38 cfs V= 4.1 fps Qfull = 4.57 cfs Vfull = 3.72 fps From Fig. 8.06.b.1: Zone = 2 From Fig. 8.06.b.2: D5o = 8 in DMAX = 12 in Riprap Class = B P s Apron Thickness = 18 in 3 Apron Length 7.5 ft Apron Width @ Outlet = 3.75 ft Apron Width @ End = 8.8 ft Length 1754 Storm System.xlsx LATEST REVISION:5/23/2024 6:18 AM PAGE 1 OF 1 Culvert Report Hydraflow Express Extension for Autodesk®Civil 3D®by Autodesk, Inc. Wednesday,Nov 29 2023 PIPE 1 (10-YR) Invert Elev Dn (ft) = 246.65 Calculations Pipe Length (ft) = 130.00 Qmin (cfs) = 15.40 Slope (%) = 0.50 Qmax (cfs) = 15.40 Invert Elev Up (ft) = 247.30 Tailwater Elev (ft) = (dc+D)/2 Rise (in) = 24.0 Shape = Circular Highlighted Span (in) = 24.0 Qtotal (cfs) = 15.40 No. Barrels = 1 Qpipe (cfs) = 15.40 n-Value = 0.012 Qovertop (cfs) = 0.00 Culvert Type = Circular Concrete Veloc Dn (ft/s) = 5.39 Culvert Entrance = Groove end projecting (C) Veloc Up (ft/s) = 6.47 Coeff. K,M,c,Y,k = 0.0045, 2, 0.0317, 0.69, 0.2 HGL Dn (ft) = 248.36 HGL Up (ft) = 248.72 Embankment Hw Elev (ft) = 249.47 Top Elevation (ft) = 253.84 Hw/D (ft) = 1.09 Top Width (ft) = 88.00 Flow Regime = Inlet Control Crest Width (ft) = 5.00 Elev(ft) PIPE 1(10-YR) Hw Depth(ft) 254.00 L I I I I I I I 6.70 253.00 5.70 252.00 - - - 4.70 251.00 - - - 3.70 250.00 1ol2.70 Inlet contr 249.00 1.70 248.00 - 0.70 247.00 - L - -0.30 246.00 -1.30 245.00 -2.30 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 Circular Culvert HGL Embank Reach(ft) Culvert Report Hydraflow Express Extension for Autodesk®Civil 3D®by Autodesk, Inc. Wednesday,Nov 29 2023 PIPE 2 (10-YR) Invert Elev Dn (ft) = 242.19 Calculations Pipe Length (ft) = 44.00 Qmin (cfs) = 36.85 Slope (%) = 0.55 Qmax (cfs) = 36.85 Invert Elev Up (ft) = 242.43 Tailwater Elev (ft) = (dc+D)/2 Rise (in) = 30.0 Shape = Circular Highlighted Span (in) = 30.0 Qtotal (cfs) = 36.85 No. Barrels = 1 Qpipe (cfs) = 36.85 n-Value = 0.012 Qovertop (cfs) = 0.00 Culvert Type = Circular Concrete Veloc Dn (ft/s) = 7.85 Culvert Entrance = Square edge w/headwall (C) Veloc Up (ft/s) = 8.54 Coeff. K,M,c,Y,k = 0.0098, 2, 0.0398, 0.67, 0.5 HGL Dn (ft) = 244.47 HGL Up (ft) = 244.48 Embankment Hw Elev (ft) = 246.34 Top Elevation (ft) = 250.00 Hw/D (ft) = 1.56 Top Width (ft) = 30.00 Flow Regime = Inlet Control Crest Width (ft) = 100.00 Elev(ft) PIPE 2(10-YR) Hw Depth(ft) 251.00 8.57 250.00 7.57 249.00 6.57 248.00 - 5.57 247.00 4.57 Ir let control 246.00 3.57 245.00 2.57 244.00 1.57 243.00 0.57 242.00 I -0.43 241.00 -1.43 0 5 10 15 20 25 3D 35 4D 45 50 55 60 65 Circular Culvert HGL - Embank Reach(ft) Culvert Report Hydraflow Express Extension for Autodesk®Civil 3D®by Autodesk, Inc. Wednesday,Nov 29 2023 PIPE 3 (10-YR) Invert Elev Dn (ft) = 236.20 Calculations Pipe Length (ft) = 143.61 Qmin (cfs) = 39.54 Slope (%) = 0.47 Qmax (cfs) = 39.54 Invert Elev Up (ft) = 236.88 Tailwater Elev (ft) = (dc+D)/2 Rise (in) = 36.0 Shape = Circular Highlighted Span (in) = 36.0 Qtotal (cfs) = 39.54 No. Barrels = 1 Qpipe (cfs) = 39.54 n-Value = 0.012 Qovertop (cfs) = 0.00 Culvert Type = Circular Concrete Veloc Dn (ft/s) = 6.23 Culvert Entrance = Square edge w/headwall (C) Veloc Up (ft/s) = 7.67 Coeff. K,M,c,Y,k = 0.0098, 2, 0.0398, 0.67, 0.5 HGL Dn (ft) = 238.72 HGL Up (ft) = 238.93 Embankment Hw Elev (ft) = 240.15 Top Elevation (ft) = 241.72 Hw/D (ft) = 1.09 Top Width (ft) = 100.00 Flow Regime = Inlet Control Crest Width (ft) = 100.00 Elev(ft) PIPE 3(10-YR) Hw Depth(ft) 242.00 I I I I I I I 5.12 241.00 4.12 24� Inlet control 3.12 239.:G - 2.12 238.00 1.12 237.:.: 0.12 236.00 -0.88 235.00 - 1 -1.88 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 Circular Culvert HGL Embank Reach(ft) Starz Gas Station Ditch #1 Q North American Green ECMDS Version 4.3-Channel Protection Design,Output Form File Specifications Options Help ENGLISH. IUSER I 7/25/2023 06:29AMI HYDRAULIC RESULTS Discharge Peak Flow Velocity(fps) Area(sq.ft) Hydraulic Normal Unreinforced Vegetation(n=0.040) (cfs) Period(hrs). Radius(ft) Depth(ft) 15.4 0.1 2.59 5.95 0.66 1.11 S=0.0085 1 L Bottom J 1 3.0 Width=2.00 ft 3.0 LINER RESULTS Not to Scale Matting Type Vegetation Characteristics Reach _ Stability Analysis Permissible Calculated Safety Factor Remarks Staple Pattern Phase' Class Type Density Shear Stress Shear Stress (psi) (Psi) Straight Unreinforced Vegetation D Bunch 75-95% 3.33 0.59 5.64 STABLE Soil Sandy Loam 0.035 0.045 0.78 UNSTABLE ■North American Green ECMDS Version 4.3-Channel Protection Design;Output Form File Specifications Options Help 'ENGLISH. (QUICK I 7/25/2023 06:29AMI HYDRAULIC RESULTS - Discharge Peak Flow Velocity(fps) Area(sq.ft) Hydraulic Normal 575(n=0.041) (cfs) Period(hrs) Radius(ft) Depth(ft) 15.4 0.1 2.55 6.04 0.66 1.12 S=0.0085 1 L Bottom J 1 3.0 Width=2.00 ft 3.0 LINER RESULTS Not to Scale Matting Type I Vegetation Characteristics Reach Stability Analysis Permissible Calculated Safety Factor Rernark:.:> Staple Pattern ' Phase Class Type Density Shear Stress Shear Stress (Psi) (psi) Straight S75 Unvegetated 1.55 0.60 2.60 STABLE Staple D Ditch #2 El North American Green ECMDS Version 4.3-Channel Protection Design,Output Form - 0 X File Specifications Options Help !ENGLISH. (USER 7/24/2023 09:44AM( HYDRAULIC RESULTS Discharge Peak Flow Velocity(fps) Area[sq.ft) Hydraulic Normal Unreinforced Vegetation(n=0.040) (cfs) Period(hrs) Radius(ft) _ Depth(ft) 135.6 0.3 2.33 15.29 1.07 1.95 S=0.0036 1 L Bottom _II ,..,,,..gc 41th 3.0 Width=2.00 ft 3.0 LINER RESULTS Not to Scale Matting Type Vegetation Characteristics I Reach _StabilityAnalysis Permissible Calculated Safety Factor Remarks Staple Pattern Phase Class Type Density Shear Stress Shear Stress (psf) [psi) Straight Unreinforced Vegetation D Bunch 75.95 a 3.33 0.44 7.61 STABLE Soil Sandy Loam 0.035 0.033 1.05 STABLE Ditch#3 n North American Green ECMDS Version 4.3-Channel Protection Design;Output Form - 0 X File Specifications Options Help ENGLISH. (USER I 7/24/2023 09:46AMI HYDRAULIC RESULTS Discharge Peak Flow Velocity(fps) Area(sq.ft) Hydraulic Normal Unreinforced Vegetation(n=0.040) fay° (cfs) Period(hrs) Radius(ft) Depth(ft) 136.9 0.3 2.53 14.58 1.21 2.25 4C'' S=0.0036 .....- 1L 1 Bottom 2.0 Width=2.00 ft -21 LINER RESULTS Not to Scale Matting Type Vegetation Characteristics 1 Reach Stability Analysis Permissible Calculated Safety Factor Remarks Staple Pattern Phase Class Type Density Shear Stress Shear Stress (psi) (psi) Straight Unreinforced Vegetation . D Bunch 75-95%; 3.33 0.50 6.60 STABLE Soil Sandy Loam 0.035 0.038 0.91 UNSTABLE • 111 North American Green ECMDS Version 4.3-Channel Protection Design,Output Form - ❑ X File Specifications Options Help (ENGLISH. (QUICK i 7/24/2023 09:48AMI HYDRAULIC RESULTS Discharge Peak Flow Velocity(fps) Area(sq.ft) Hydraulic Normal S75(n=0.025) (cfs) Period(hrs) Radius(ft) Depth(ft)_, 36.9 0.3 3.59 10.28 1.01 1.82 S=0.0036 ' 1 L Bottom _I 1 2.0 Width=2.00 ft 2.0 LINER RESULTS Not to Scale Matting Type Vegetation Characteristics Reach Stability Analysis Permissible Calculated Safety Factor Remarks Staple Pattern Phase Class Type Density Shear Stress Shear Stress (psi) (psi) Straight S75 Unvegetated 1.55 0.41 3.79 STABLE Staple D Ditch#4 IllNorth American Green ECMDS Version 4.3-Channel Protection Design,Output Form - 0 X File Specifications Options Help ENGLISH. IUSER I 7/24/2023 09:49AMI HYDRAULIC RESULTS Discharge Peak Flow Velocity(fps) Area(sq.ft) Hydraulic Normal Unreinforced Vegetation(n=0.040) (cfs) _Period(hrs) _ Radius(ft) _ Depth(ft) 31.6 0.5 2.43 12.98 1.14 2.10 , '`,`, S=0.0036 #`' 1 L Bottom J 1 2.0 Width=2.00 ft 2.0 LINER RESULTS Not to Scale Matting Type Vegetation Characteristics Reach Stability Analysis Permissible Calculated Safety Factor Remarks Staple Pattern Phase Class Type Density Shear Stress Shear Stress (psi) (psi) Straight .. Unreinforced Vegetation . D .Bunch 75-95% 3.33 0.47 7.07 STABLE . - Soil Sandy Loam 0.035 0.036 0.98 UNSTABLE IINorth American Green ECMDS Version 4.3-Channel Protection Design;Output Form — 0 X File Specifications Options Help ENGLISH. (QUICK I 17/24/2023 09:49AM1.-- HYDRAULIC RESULTS Discharge Peak Flow Velocity(fps) Area(sq.ft) Hydraulic Normal S75(n=0.027) (cfs) Period(hrs). Radius(ft) Depth(ft) 31.6 0.5 3.29 9.61 0.98 1.75 S=0.0036 1 L Bottom J 1 2.0 Width=2.00 ft 2.0 LINER RESULTS Not to Scale Matting Type Vegetation Characteristics I Reach Stability Analysis Permissible Calculated Safety Factor Remarks Staple Pattern Phase Class Type Density Shear Stress Shear Stress (psf) (psf) Straight S75 i Unvegetated 1.55 0.39 3.95 STABLE Staple D Ditch#5 Q North American Green ECMDS Version 43-Channel Protection Design,Output Form — 0 X File Specifications Options Help ENGLISH. FUSER I 7/24/2023 09:SOAMI HYDRAULIC RESULTS • Discharge Peak Flow Velocity(fps) Area(sq.ft) Hydraulic Normal Unreinforced Vegetation(n=0.040) • (cfs) Period(hrs) Radius(ft) . Depth(ft) 32.8 0.5 2.46 13.35 1.16 2.13 S=0.0036 • 1 L Bottom _I 1 2.0 Width=2.00 ft 2.0 • LINER RESULTS Not to Scale Matting Type Vegetation Characteristics Reach Stability Analysis Permissible Calculated Safety Factor Remarks Staple Pattern Phase Class Type Density Shear Stress Shear Stress (psf) [psf] Straight Unreinforced Vegetation D Bunch 75.95% 3.33 0.48 6.96 STABLE Soil Sandy Loam J 0.035 0.036 0 96 UNSTABLE IIINorth American Green ECMDS Version 4.3-Channel Protection Design,Output Form — 0 X File Specifications Options Help ENGLISH. !QUICK ) 7/24/2023 09:50AMI HYDRAULIC RESULTS Discharge Peak Flow 'Velocity(fps) Area(sq.ft) Hydraulic Normal S75(n=0.026) [cis) Period[hrs] Radius(ft) Depth(ft) 32.8 0.5 3.36 9.77 0.99 1.77 S=0.0036 1 L Bottom _I 1 2.0 Width=2.00 ft 2.0 LINER RESULTS Not to Scale Matting Type Vegetation Characteristics Reach Stability Analysis Permissible Calculated Safety Factor Remarks Staple Pattern Phase Class Type Density Shear Stress Shear Stress (psf) (psf) Straight S75 Unvegetated 1.55 0.40 3.91 STABLE Staple D n North American Green ECMDS Version 4.3-Channel Protection Design,Output Form — ❑ X File Specifications Options Help ENGLISH. 'USER I 7/24/2023 10:39AMI HYDRAULIC RESULTS Discharge Peak Flow Velocity(fps) Area(sq.ft) Hydraulic Normal Rock Riprap(n=0 078) (cis) Period(hrs). Radius(ft) Depth(ft) 132.8 0.5 1.49 22.06 1.49 2.86 S=0.0036 1 L Bottom _1 1 2.0 Width=2.00 ft 2.0 LINER RESULTS Not to Scale Matting Type Vegetation Characteristics Reach Stability Analysis Permissible Calculated Safety Factor Remarks Staple Pattern ' Phase Class Type Density Shear Stress Shear Stress: (psf) (psf) Straight Rock Riprap Unvegetated 3.33 0.64 5.19 STABLE 10in 4D Site Solutions, Inc. DITCH CALCULATIONS NOTE:sheet only set up to handle Tc from 5 min to 30 min A. Flow velocity<2.0 fps when discharging to wetlands B. Flow velocity<4.5 fps all other cases** C. Channel slope<5.0%for curb outlet swales 1754-Starz Gas Station Rainfall Intensity Storm Event 5-min 10-min 15-min 30-min 10-yr 7.88 6.31 5.32 3.86 25-yr 8.88 7.07 5.98 4.43 50-yr 9.56 7.61 6.43 4.84 100-yr 10.20 8.13 6.85 5.25 Tc Drainage Impervious Grassed Storm Rainfall Ditch No. C Kerby Kirpich Intensity Q(cfs) Area(ac) Area(ac) Area(ac) Event(yr) Total Tc Tc Used (in/hr) L(ft) n s Tov L(ft) S Tit, 1 2.44 1.88 0.56 0.80 n/a 560.0 0.006 7.30 7.30 5 10-yr 7.88 15.39 2 12.27 5.67 6.61 0.60 n/a 1630.0 0.005 18.58 18.58 20 10-yr 4.83 35.60 3 12.71 5.86 6.84 0.60 n/a 1880.0 0.005 20.74 20.74 20 10-yr 4.83 36.85 4 14.88 5.72 9.15 0.55 n/a 3190.0 0.005 29.92 29.92 30 10-yr 3.86 31.58 5 15.44 5.94 9.50 0.55 n/a 3630.0 0.005 34.41 34.41 30 10-yr 3.86 32.77 printed: 1/17/2024 5:44 PM Page 1 of 1 4D Site Solutions, Inc. PIPE CALCULATIONS NOTE:sheet only set up to handle Tc from 5 min to 30 min A. Cross-pipes to use 25-yr storm inensity 1754-Starz Gas Station Rainfall Intensity Storm Event 5Win 15-min 10-yr 7.88 6.31 5.32 3.86 25-yr 8.88 7.07 5.98 4.43 50-yr 9.56 7.61 6.43 4.84 100-yr 10.20 8.13 6.85 5.25 Tc Drainage Storm Rainfall Pipe No. C Kerby Kirpich Intensity Q(cfs) Area(ac) Event(yr) Total Tc Tc Used (in/hr) L(ft) n s Toy L(ft) S Tch 1 2.43 0.80 n/a 590.0 0.008 6.98 6.98 5 10-yr 7.88 15.35 2 12.71 0.60 n/a 1880.0 0.005 20.74 20.74 20 10-yr 4.83 36.85 3 14.88 0.55 n/a 3190.0 0.005 29.92 29.92 30 10-yr 3.86 31.58 printed: 1/17/2024 5:45 PM Page 1 of 1 OUTLET PROTECTION DATE DESIGN PHASE DESIGN 09-14-21 PRELIM / / PROJECT NAME PROJECT NO CONSTR / X / Starz Gas Station 1754 REVISION / / LOCATION BY RECORD / / Hoke County, North Carolina CJP OTHER / / CHECKED BY (SPECIFY) CSB Storm Outlet Structure FES No.= FES 34 Q1o/Qfull = 0.31 Pipe Dia= 15 in V/Vfull = 0.87 Q10= 1.44 cfs V= 3.2 fps Qfull = 4.57 cfs Vfull = 3.72 fps From Fig. 8.06.b.1: Zone = 2 From Fig. 8.06.b.2: D5o = 8 in DMAX = 12 in !.Ii:i;PStItIi; Riprap Class = B Apron Thickness = 18 in . Apron Length 7.5 ft • Apron Width @ Outlet = 3.75 ft • Apron Width @ End = 8.8 ft Length Storm Outlet Structure FES No.= FES 32 Qio/Qfull = 0.46 Pipe Dia= 15 in V/Vfull = 0.97 Q10= 2.14 cfs V= 3.7 fps Qfull = 4.70 cfs Vfull = 3.82 fps From Fig. 8.06.b.1: Zone = 2 From Fig. 8.06.b.2: D5o = 8 in DMAX = 12 in Riprap Class = B s Apron Thickness = 18 in z Apron Length = 7.5 ft Apron Width @ Outlet = 3.75 ft Apron Width @ End = 8.8 ft Length 1754 Storm System.xlsx LATEST REVISION: 1/17/2024 5:44 PM PAGE 1 OF 5 OUTLET PROTECTION DATE DESIGN PHASE DESIGN 09-14-21 PRELIM / / PROJECT NAME PROJECT NO CONSTR / X / Starz Gas Station 1754 REVISION / / LOCATION BY RECORD / / Hoke County, North Carolina CJP OTHER / / CHECKED BY (SPECIFY) CSB Storm Outlet Structure FES No.= FES 33 Q1o/Qfull = 0.70 Pipe Dia= 15 in V/Vfull = 1.08 Q10= 3.28 cfs V= 4.1 fps Qfull = 4.70 cfs Vfull = 3.82 fps From Fig. 8.06.b.1: Zone = 2 From Fig. 8.06.b.2: D5o = 8 in DMAX = 12 in Riprap Class = B s Apron Thickness = 18 in z Apron Length = 7.5 ft Apron Width @ Outlet = 3.75 ft Apron Width @ End = 8.8 ft L Length 1 Storm Outlet Structure FES No.= FES 35 Q1o/Qfull = 0.74 Pipe Dia= 15 in V/Vfull = 1.09 Q10= 3.38 cfs V= 4.1 fps Qfull = 4.57 cfs Vfull = 3.72 fps From Fig. 8.06.b.1: Zone = 2 From Fig. 8.06.b.2: D5o = 8 in DMAX = 12 in •�•�•••••••••• Riprap Class = B IttIIIIiJJJIII s Apron Thickness = 18 in Apron Length 7.5 ft Apron Width @ Outlet = 3.75 ft Apron Width @ End = 8.8 ft Length 1754 Storm System.xlsx LATEST REVISION: 1/17/2024 5:44 PM PAGE 2 OF 5 OUTLET PROTECTION DATE DESIGN PHASE DESIGN 09-14-21 PRELIM / / PROJECT NAME PROJECT NO CONSTR / X / Starz Gas Station 1754 REVISION / / LOCATION BY RECORD / / Hoke County, North Carolina CJP OTHER / / CHECKED BY (SPECIFY) CSB Storm Outlet Structure FES No.= PO 37 Q1o/Qfull = 0.22 Pipe Dia= 8 in V/Vfull = 0.78 Q10= 0.45 cfs V= 4.6 fps Qfull = 2.04 cfs Vfull = 5.84 fps From Fig. 8.06.b.1: Zone = 1 From Fig. 8.06.b.2: D5o = 4 in DMAX = 6 in Riprap Class = A s Apron Thickness = 9 in z Apron Length = 2.7 ft Apron Width @ Outlet = 2 ft Apron Width @ End = 3.3 ft L Length 1 Storm Outlet Structure FES No.= FES 36 Q1o/Qfull = 0.07 Pipe Dia= 15 in V/Vfull = 0.52 Q10= 0.53 cfs V= 3.2 fps Qfull = 7.65 cfs Vfull = 6.22 fps From Fig. 8.06.b.1: Zone = 2 From Fig. 8.06.b.2: D5o = 8 in DMAX = 12 in •�•�•••••••••• Riprap Class = B •••••••••••••• s Apron Thickness = 18 in �•�•�•�•�•�•�• '8 Apron Length 7.5 ft ..�.�...:1:1:1 3 Apron Width @ Outlet = 3.75 ft •• •• ••• Apron Width @ End = 8.8 ft Length 1754 Storm System.xlsx LATEST REVISION: 1/17/2024 5:44 PM PAGE 3 OF 5 OUTLET PROTECTION DATE DESIGN PHASE DESIGN 09-14-21 PRELIM / / PROJECT NAME PROJECT NO CONSTR / X / Starz Gas Station 1754 REVISION / X / LOCATION BY RECORD / X / Hoke County, North Carolina CJP OTHER / X / CHECKED BY (SPECIFY) C_SB _ Storm Outlet Structure FES No.= FES 14 Q1o/Qfull = 0.19 Pipe Dia= 15 in V/Vfull = 0.75 Qio= 0.88 cfs V= 2.8 fps Qfull = 4.57 cfs Vfull = 3.72 fps From Fig. 8.06.b.1: Zone = 2 From Fig. 8.06.b.2: D5o = 8 in DMAX = 12 in Riprap Class = B s Apron Thickness = 18 in z Apron Length = 7.5 ft Apron Width @ Outlet = 3.75 ft Apron Width @ End = 8.8 ft L Length Storm Outlet Structure FES No.= PIPE 2 OUT Q1o/Qfull = 1.24 Pipe Dia= 30 in VNfull = MAX Q10= 36.85 cfs V= #VALUE! fps Qfull = 29.63 cfs Vfull = 6.03 fps From Fig. 8.06.b.1: Zone = 3 From Fig. 8.06.b.2: D5o = 10 in DMAX = 15 in •:••••••••••••• Riprap Class = 1 •••••••••••••• s Apron Thickness = 22.5 in �•�•�•�•�•�•�• '8 Apron Length 20.0 ft ..�.�...:1:1:1 3 Apron Width @ Outlet = 7.5 ft •• •• ••• Apron Width @ End = 22.5 ft Length 1754 Storm System.xlsx LATEST REVISION: 1/17/2024 5:44 PM PAGE 4 OF 5 OUTLET PROTECTION DATE DESIGN PHASE DESIGN 09-14-21 PRELIM / / PROJECT NAME PROJECT NO CONSTR / X / Starz Gas Station 1754 REVISION / X / LOCATION BY RECORD / X / Hoke County, North Carolina CJP OTHER / X / CHECKED BY (SPECIFY) CSB Storm Outlet Structure FES No.= PIPE 3 OUT Q1o/Qfull = 0.86 Pipe Dia= 36 in V/Vfull = 1.12 Q10= 39.54 cfs V= 7.3 fps Qfull = 45.90 cfs Vfull = 6.48 fps From Fig. 8.06.b.1: Zone = 3 From Fig. 8.06.b.2: D5o = 10 in DMAX = 15 in gorgorgorgq Riprap Class = 1 i••••••••••••••4* Apron Thickness = 22.5 in I 3 Apron Length = 24.0 ft Apron Width @ Outlet = 9 ft Apron Width @ End = 27.0 ft Length 1754 Storm System.xlsx LATEST REVISION: 1/17/2024 5:44 PM PAGE 5 OF 5