Loading...
HomeMy WebLinkAboutWQ0020808_Monitoring - 06-2024_20240716Monitoring Report Submittal Permit Number#* Name of Facility:* Month:* June WQ0020808 3M Pittsboro Plant Report Information Type * NDMR, NDAR-1, NDAR-2, NDMLR Confirmation Email Address: Name of Submitter: * Signature: Date of submittal: Initial Review Year:* 2024 Upload Document* Pittsboro_WQ0020808_NDMR_June2024.pdf 1.5MB PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). DCHRISTMAN@MMM.COM Daniel Christman Reviewer: Wanda.Gerald 7/16/2024 This will be filled in automatically Is the project number correct?* W00020808 Is the monitoring report accepted?* Yes NO Regional Office* Raleigh Reviewer: _anonymous Review Date: 7/25/2024 FORM: NDMR 10-13 NON -DISCHARGE MONITORING REPORT (NDMR) Page t_ of 4 Permit No.: WQ0020808 Facility Name: 3M Pittsboro Plant County: Chatham Month: June Year: 2024 PPI: 001 7 Flow Measuring Point: Influent ❑ Effluent ❑ No flow generated Parameter Monitoring Point: ❑ Influent ❑✓ Effluent ❑ Groundwater Lowering ❑ Surface water Parameter Code - 11 50050 00310 31616 00610 00400 00530 00076 0 aU � 0 O ° F O LL pE V y QZ � H z � c �°- z o 0aCnn Np 00 n 24-hr hrs GPD mg/I #/100ml mg/I su mg/I NTU mg/I mg/I mg/I mg/I 1 863 1.14 2 12:15 0.67 887 7.7 1.21 3 1,268 1.17 4 10:10 0.58 1,625 <2.0 <1.0 <0.020 <2.5 1.27 1.1 85 86.1 7.9 5 1,265 1.31 6 06:35 0.58 1,911 1.42 7 20:15 0.58 1,777 1.27 8 07:55 0.58 1,436 1.08 993 1.17 0.33 592 1.26 0.67 1,453 7.46 1.31 1,080 1.1 U17:1 1.25 1,452 1.16 0.58 1,168 1.07 1.25 0 1.04 1,094 1.17 1 0.58 881 7.39 1.1 181 12:45 1 0.58 0 1.11 191 19:55 1 0.58 0 1.89 20 1,421 1.24 211 15:45 1 0.58 1,298 1.22 22 10:50 0.67 1,166 1.17 23 18: 00 1 1,024 7.4 1.17 24 10:15 0.75 1,288 1.17 251 12:00 0.83 1,580 1.27 26 0945 2 1,149 1.28 271 09:30 0.58 1,352 1.11 281 1,402 2.2 291 1,322 2.31 30 1,018 2.49 31 Average: 1,126 0.00 1.00 0.00 0.00 1.33 1.10 85.00 86.10 7.90 Daily Maximum: 1,911 2.00 1.00 0.02 7.70 2.50 2.49 1.10 85.00 86.10 7.90 Daily Minimum: 0 2.00 1.00 0.02 7.39 2.50 1.04 1.10 85.00 86.10 7.90 Sampling Type: Estimate Grab Grab Grab Grab Grab Recorder Monthly Avg. Limit: 5,900 10 14 4 5 Daily Limit: 15 24 6 6-9 10 10 Sample Frequency: Monthly 4 x Year 4 x Year 4 x Year Weekly 4 x Year Continuous FORM: NDMR 10-13 NON -DISCHARGE MONITORING REPORT (NDMR) Page z of `t Permit No.: W00020808 Facility Name: 3M Pittsboro Plant County: Chatham Month: June Year: 2024 PPI: pp2 Flow Measuring in uent uent o ow generate Parame�er Mo i Oringn ointoun wa er owering ur ace a er Parameter Code — ► WQ01 Q Q E U O c E °' U in O W 24-hr hrs gal/day'? 1 0 2 12:15 0.67 0 3 2828 4 10:10 0.58 1756 i[ 5 1618 " 6 06:35 0.58 1505 7 20:15 0.58 1248 8 07:55 0.58 0 9 0 10 11:10 0.33 2330 11 12:10 0.67 988 12 1375 13 12:50 1.25 1106 14 19:55 0.58 0 15 15:45 1.25 0 16 0 17 17:15 0.58 3535 18 12:45 0.58 896 19 19:55 0.58 1491 20 1176 21 15:45 0.58 998 22 10:50 0.67 0 23 18:00 1 0 24 10:15 0.75 3103 25 12:00 0.83 855 26 09:45 2 11523 271 09:30 0.58 1414 28 1046 29 0 30 0 31 Average: 1,359.70 Daily Maximum: 11,523.00 Daily Minimum: 0.00 Sampling Type: Estimate Monthly Avg. Limit: Daily Limit: Sample Frequency: Monthly FORM: NDMR 10-13 NON -DISCHARGE MONITORING REPORT (NDMR) Page -3 of L— Permit No.: WQ0020808 Facility Name: 3M Pittsboro Plant County: Chatham Month: June Year: 2024 PPI: 003 n pent uent No ow generate Flow Measuring in . Parame er n uen uen roun wa er owering Surface Water Mo i onng oint: Parameter Code ► WQ01 0 m > c E U ~ 0 O r O y V WO W 24-hr hrs gal/day 1 75788 2 75788 3 75788 4 75788 5 75788 6 75788 7 75788 8 75788 9 75788 101 75788 111 75788 12 75788 13 75788 14 75788 15 75788 16 75788 17 75788 18 75788 19 75788 20 75788 21 75788 22 75788 23 75788 24 75788 25 75788 26 75788 27 75788 28 75788 29 75788 30 75788 31 Average: 75,788.00 Daily Maximum: 75,788.00 Daily Minimum: 75,788.00 Sampling Type: Estimate Monthly Avg. Limit: Daily Limit: Sample Frequency: Monthly FORM: NDMR 10-13 NON -DISCHARGE MONITORING REPORT (NDMR) Page 4 of f_ Sampling Person(s) Certified Laboratories Name: Randall Jarrell Name: Wastewater Management, L.L.C. Name: Name: Environmental Canservatior-Laboratories Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Randall Jarrell ❑ Yes El No Permittee: 3M Corporation, Moncure Certification No.: 7937 Signing Official: Blake Arnett Grade: IV Phone Number: 919-210-2500 Signing Officials Title: Plant Manager Has the ORC changed since the previous NDMR? Phone Number: 919-642-4011 Permit Expiration: 6/30/2025 ►<<�� 7 Z . Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617