Loading...
HomeMy WebLinkAboutWQ0020808_Monitoring - 05-2024_20240628Monitoring Report Submittal Permit Number#* Name of Facility:* Month: * May WQ0020808 3M Pittsboro Plant Report Information Type * NDMR, NDAR-1, NDAR-2, NDMLR Confirmation Email Address: Name of Submitter: * Signature: Date of submittal: Initial Review Year:* 2024 Upload Document* Pittsboro_WQ0020808_NDMR_May2024.pdf 1.71MB PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). DCHRISTMAN@MMM.COM Daniel Christman Reviewer: Wanda.Gerald 6/28/2024 This will be filled in automatically Is the project number correct?* W00020808 Is the monitoring report accepted?* Yes NO Regional Office* Raleigh Reviewer: _anonymous Review Date: 7/3/2024 DocuSign Envelope ID: 508AOCC4-79DO-4EEO-9EE7-63C8DDE45BDD FORM: NDMR 10-13 NON -DISCHARGE MONITORING REPORT (NDMR) Page I of �t Permit No.: WQ0020808 Facility Name: 3M Pittsboro Plant County: Chatham Month: May Year: 2024 PPI: 001 Flow Measuring Point: Q Influent ❑ Effluent ❑ No flow generated Parameter Monitoring Point: ❑ influent Effluent ❑ Groundwater Lowering ❑ Surface water Parameter Code 0 50050 00310 31616 00610 00400 00530 00076 > 0 Q E U O � E A' ~ cn O o �- p m U!g tL O" U ° o a Z = O v z Z B C Z N B, N O a 24-hr hrs GPD mg/I #/100ml mg/I su mg/I NTU mg/l mg/l mg/I mgll 1 19:05 1.25 1,038 0.991 2 14:55 0.58 907 0.817 3 2,621 * 0.744 4 10:35 0.67 905 0.902 5 2,928 * 0.947 6 17:10 0.75 1,033 8.21 0.904 7 13:45 0.83 1,552 2.153 8 17:50 0.67 2,280 1.194 9 14:40 0.75 2,338 1.347 10 2,285 * 1.447 11 10:50 0.67 1,743 1.759 12 2,381 * 1.743 13 15:30 0.75 887 7.48 1.56 14 11:30 0.67 1,123 1.071 15 11:25 1 1,644 1.036 16 16:10 0.75 0 1.081 17 1,705 * 1.081 18 09:05 0.67 2,013 * 1.056 19 10:45 0.66 2,673 7.42 1.175 20 10:40 0.58 1,188 1.117 21 2,183 * 1.272 22 15:50 0.75 1,651 1.358 23 09:55 1.25 1,963 1.183 24 10:00 0.58 1,805 1.133 25 1,712 * 1.141 26 1,361 * 1.14 27 14:25 0.75 0 7.45 1.109 28 H 1,671 * 1.171 29 15:10 1 1,605 1.057 30 15:10 0.67 1,903 1.053 31 18:00 0.83 1,334 1.161 Average: 1,627 1.19 Daily Maximum: 2,928 8.21 2.15 Daily Minimum: 0 7.42 0.74 Sampling Type: Estimate Grab Grab Grab Grab Grab Recorder Monthly Avg. Limit: 5,900 10 14 4 5 Daily Limit: 15 24 6 6-9 10 10 Sample Frequency: Monthly 4 x Year 4 x Year 4 x Year Weekly 4 x Year Continuous DocuSign Envelope ID: 508AOCC4-79DO-4EEO-9EE7-63C8DDE45BDD FORM: NDMR 10-13 NON -DISCHARGE MONITORING REPORT (NDMR) Page p_ of 4 Permit No.: WQ0020808 Facility Name: 3M Pittsboro Plant I County: Chatham Month: May Flow Measuring Xn i nt Mom bring ?�oi • • ' • Daily Maxim Daily Minimum: Sampling Type: Monthly Avg. Limit: DocuSign Envelope ID: 508AOCC4-79DO-4EEO-9EE7-63C8DDE45BDD FORM: NDMR 10-13 NON -DISCHARGE MONITORING REPORT (NDMR) Page 3 of Facility Name: County: Chatham Month: May 11Flow Measuring�. • • Daily Maximum: DocuSign Envelope ID: 508AOCC4-79DO-4EEO-9EE7-63C8DDE45BDD FORM: NDMR 10-13 NON -DISCHARGE MONITORING REPORT (NDMR) Page 'A of t Sampling Person(s) Name: Randall Jarrell Name Certified Laboratories Name: Wastewater Management, L.L.C. Name: Environmental Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. 3M has identified a data logging issue with the WWTP feed pump flow meter causing influent volume to be overreported in our internal database. The system is logging a baseline flow above zero gpm even when the feed pumps are not operating, which is not possible. 3M believes the issue began with the last annual calibration performed on 5/7/24, which coincides with the start of the higher data transmissions. 3M is currently working with the calibration technician to resolve the issue. 3M is able to provide the flow volumes through alternative methods. The flow meter has an on -site display panel that continues to give accurate readings, and those readings are recorded by our third -party WWTP operator each day the treatment facility is serviced. When the operator is not on site (primarily weekends) there are no direct flow recordings, but 3M can rely on the database records. For this report, the direct display values are used in the total feed flow calculations for days when in -person recordings were taken. For days when no direct recording was taken, 3M has manually calculated the total flow by subtracting the higher baseline flow from the values recorded in our database. The manually calculated values are marked with an asterisk (*) on the NDMR. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Randall Jarrell ❑ Yes 21 No Permittee: 3M Corporation, Moncure Certification No.: 7937 Signing Official: Blake Arnett Grade: IV Phone Number: 919-210-2500 Signing Officials Title: Plant Manager Has the ORC changed since the previous NDMR? Phone Number: 919-642-4011 Permit Expiration: 6/30/2025 DocuSigned,b_y: • aVVkll 6/28/2024 Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617