June 27, 2024
Subject:
Compliance Evaluation Inspection
Permit # WQ0020808
Facility: 3M Pitttsborough Plant Domestic
Wastewater and Reclaimed Water System
Chatham County
Mr. Christman,
On January 24, 2024, Jim Westcott from the Raleigh Regional Office visited the 3M Company
Wastewater Treatment and Reclaimed Water Utilization Facility system to evaluate compliance
with the subject permit. The assistance of the ORC, Randall Jarell, Daniel Christman and
Andrew Miller was appreciated at the time of inspection.
The facility is permitted for the operation of a 5,900 gallon per day (GPD) reclaimed water
generation, dedicated utilization, and conjunctive utilization facility consisting of the:
continued operation of a reclaimed water generation systems consisting of a 10,500-gallon flow
equalization tank with two 40 gallon per minute (GPM) transfer pumps; an influent flow meter;
a ZeeWeed®/ZenoGem® wastewater treatment system consisting of a 3,000 gallon aerobic
reactor chamber, a 3,000 gallon anoxic chamber with pH adjustment system, and a filter
chamber with two cassettes of 0.1 micron hollow fiber membranes; a 1,000 gallon sludge
holding tank; two 91 cubic foot per minute (CFM) blowers; two 15 GPM pumps to convey
permeate from the filter chamber to the back -pulse system or the disinfection system; a 100
gallon back -pulse tank to clean the membrane filters with two 30 GPM pumps; a 15 gallon
hypochlorite tank and a % GPM chemical metering pump; an ultraviolet (UV) disinfection
system with two UV units, and two 15 GPM recirculation pumps; a turbidimeter; a 32,000
gallon storage tank with two 6 GPM pumps; an effluent flow meter; and all associated piping,
valves, controls, and appurtenances; the 480 gallon per day (GPD) wastewater treatment and
spray irrigation facility consisting of a 1,250 gallon baffled septic tank with an effluent filter; a
1,000 gallon pump tank; dual 210 square foot (ft2) sand filters; a tablet chlorination system; a
1,578 gallon storage tank; a 2,440 gallon pump tank; 580 linear feet (LF) of %-inch force main;
a 0.23-acre spray irrigation area with five spray heads; and all associated piping, valves,
controls, and appurtenances with no discharge of wastes to surface waters.
NORTH CARCLINAD � �
North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 1 3800 Barrett Drive I Raleigh, North Carolina 27609
919.791.4200
DocuSign Envelope ID: 3D5D4110-21FD-4BB1-8728-D055C127B88B
The permit, which was issued June 27, 2019, is effective through June 30, 2025. Division
records indicate the required annual fee for the period ending April 30, 2025, due May 11,
2024, has been paid.
Findings during the inspection were as follows:
The reclaimed waters generated from the City of Pittsboro Reclaimed water distribution system
including the on -site wastewater treatment system which treats discharge waste from the 3M
building are used in the mill and cooling towers for the manufacturing of granulated materials
applied to roofing shingles.
The system generates an average flow of 1200-1800 GPD.
The receiving water entering the facility from the City of Pittsboro has an in -line turbidity
meter to monitor the process water quality to the 27,000-gallon reclaimed storage tank. Water
quality above 6 NTU will secure the reclaimed water flow and transfer directly to potable
water. A permissive allows for direct transfer through automatic backflow prevention device to
supply potable water to the facility.
The current ORC and backup ORC records were available for review.
Dissolved oxygen and pH meter are calibrated by the ORC daily.
All permit required NDMR were available for review and no discrepancies were noted.
Monthly monitoring reports and annual inspection log from 2002 to the date of inspection
were thorough and complete.
The Operation and Maintenance Plan was recently updated by Arcadis. The plan was detailed
covering all aspects of the facility operations.
Wastewater Preventative Measures (PM) log, water pressure reduction valve certification,
quarterly plant water pressure PM's and manual backflow prevention check valve certification
documentation was available for review from 2016 to the date of inspection.
The Work Order system was developed by SAP and detailed all pertinent required and
emergency maintenance methods and procedures.
All reclaimed water piping was appropriately labeled and color coded.
Eurofin conducts all permit required lab analysis.
Atlantic Environmental conducts influent magmeter flow meter calibrations. The previous field
calculation date was 8/22/23.
The Ultra -violet Disinfection system consists of two banks each containing 4 modules each
and cleaned annually.
The membranes are removed and cleaned annually and soaked in a citric acid and
hypochlorite solution for 24 hours to remove particulate buildup.
The control skid has 32 in line alarms for process monitoring.
ID �`y� North Carolina Department of Environmental Quality I Division of Water Resources
r/ 512 North Salisbury Street 1 1611 Mail Service Center I Raleigh, North Carolina 27699-1611
NORTH CAROLINA 919.707.9000
onparhnem of EmironmanW 9uallly
DocuSign Envelope ID: 3D5D4110-21FD-4BB1-8728-D055C127B88B
A 25% Sodium Hydroxide is delivered for alkalinity adjustment.
Residuals from the system are transferred to the Pittsboro Wastewater Treatment Facility for
processing by Forever Clean. Residuals were last removed from the system 8/ 15/23 for a total
of 9,000 gallons.
An on -site backup portable generator is available in the event of loss of commercial power and
has a direct tie-in for line power in the event of a power loss.
The control skid has an integrated auto dialer alarm monitoring system for emergency call out
response.
Please continue to periodically inspect and evaluate the wastewater spray irrigation system
components are properly maintained and operating as designed. Maintain all associated
operational records onsite for a period of five years as required by the subject permit.
If you have questions or comments about this inspection or the requirements to take corrective
action (if applicable), then please contact Jim Westcott at james.westcott(a)ncdenr.gov or 919-
791-4247.
Sincerely,
E
DocuSigned b/yj:�U� [1 t�
372DCBCB61EE4A8...
Michael Hall, Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Cc: Laserfiche