Loading...
HomeMy WebLinkAboutSW3230803_Plansheet - Other_20240620 (4) APPROVED MANUFACTURER'S LIST ♦ ♦ �� // 0 C\ \ / CLUSTER MAIL BOX UNIT; MANUFACTURED BY FLORENCE MANUFACTURING \ \ co \ \ MB16 COMPANY AND DISTRIBUTED BY BOMMER OUTDOOR MAILBOXES, OR APPROVED / ` \ / C0 — — — — _ _ / 2P EQUAL. SEE APPROVED 'CBU' LIST BELOW. MANUFACTURER'S PRODUCT MUST BE ♦ / / CURRENTLY LICENSED BY THE UNITED STATES POSTAL SERVICE READY FOR COMMERCIAL USE WITH 8, 12, OR 16 INDIVIDUAL NUMBERED TENANT � � Pi "In V 4P COMPARTMENTS, TWO PARCEL LOCKERS FOR PACKAGE DELIVERY, ONE MAIL I IN, ` / ` — — — — — SLOT FOR OUT-GOING MAIL WITH A SECURE MASTER DOOR PREPARED FOR 'USPS' master planning . civil engineering POSTAL LOCK SYSTEM FOR SECURE ACCESS. CONSTRUCTED OF HIGH GRADE urban design . landscape architecture ALUMINUM AND STAINLESS STEEL WITH A POWDER COAT FINISH. FINAL COLOR p 24 — CHOICE BY OWNER FROM MANUFACTURER'S STANDARD COLOR LIST. FURNISHED 919 berryhill rd.ste101.charlotte,nc 28208 23 27 / i WITH AN INTEGRAL PEDESTAL SURFACE MOUNTING SYSTEM TO A CONCRETE PAD 704.332.1204 . www.dpr.design / INSTALLED BELOW, COMPLETE INSTALLATION PER MANUFACTURER'S NC Firm License#C-0560 SPECIFICATIONS. LOCATED 'CBU'AND CONCRETE PAD PER DETAIL ON THIS SHEET, SEE PLAN FOR LOCATIONS. CLIENT/OWNER USPS APPROVED MANUFACTURERS OF MILLS VENTURES, LLC.(R. DEAN HARREL) ` CLUSTER BOX UNITS(CBUs)&WALL-MOUNTED CENTRALIZED MAIL RECEPTACLES 5615 POTTER ROAD �I MATHEWS, NORTH CAROLINA 28104 COMPANY ADDRESS CITY STATE ZIP PHONE WEB SITE DESIGN TYPES 704.870.4614SURVEYOR \ I O \ / / I Postal Products Unlimited SOOWOklahomaAve. Milwaukee W 53207-2649 800-229-4500 wwo.mailproduds.com Horizontal EAGLE ENGINEERING W O20 19 I 15 30 /I 1101 Investment Blvd., 2013A VAN BUREN AVE. O / O \ / `\ / / I Web Suite#140 Grapevine TX 95760 800-762-0002 wwvo.budgetmailbox.com Vertical Cases,Horizontal INDIAN TRAIL, NORTH CAROLINA 28079 NOTES:WALL MOUNTED MAILBOXES MUST OF TYPE USPS-STD-4C RECEPTACLES. 704.882.4222 WETLANDS Iz \ / W 14 A i LOWRYS ENVIRONMENTAL&ECOLOGICAL SERVICES I; 'Ao \ 31 1823 QUINN ROAD CHESTER, SOUTH CAROLINA 29706 fl 1 ` / 1&s�0 L\ GEOTECH SUMMIT ENGINEERING 3575 CENTRE CIRCLE DRIVE FORT MILL, SOUTH CAROLINA 29715 704.504.1717 FEMA O USPS > _1 MAP#3710449600J, EFFECTIVE 10/16/2008 L _ _ _ KEY MAP H MBP6 4P CLUSTER MAIL BOX UNIT CLUSTER MAIL BOX UNIT CUB COMMERCIAL CUB COMMERCIAL 35 �' \ MAILBOX UNIT- 16 DOOR MAILBOX UNIT WITH (2) PARCEL UNITS. (4) LARGE PARCEL UNITS. 18"(DEPTH)x 30%"(WIDTH) 18" (DEPTH)x 30%" (WIDTH) 04 36 / \ V / ® / / L 04 O 37 / 2.5'VALLEY GUTTER / � C.O.S. cD \ / \ / 6'PLANTING STRIP \ / CLUSTER MAIL / BOX UNIT,SEE MAIL BOX UNIT \ O 38 / PLAN FOR CONCRETE PAD, 3: / LOCATION SEE DETAIL PROJECT Q 2.0' ° > MCCOY FARM ° 000 wp ° O m p00 a 000 Lu wp0 00 F- W ~ ♦ / 4 41 WESLEY CHAPEL ROAD O I J ` \ 4.0'2.0 WESLEY CHAPEL, NORTH CAROLINA Ul ` / 42 S PUBLIC H/CPER RAMP U d PROJECT NUMBER \ O 0 SIDEWALK PER CITY O O \ C.O.S. 0 STDS. m ui 19076 � @ � \ 43 \ II d DATE r O / NOTE: 05/07/2021 C) ` INSTALL CLUSTER MAIL BOX UNIT WITH THE FRONT FACE/ \ INDIVIDUAL NUMBERED TENANT COMPARTMENTS FACING THE SIDEWALK,TYP. ISSUED FOR CONSTRUCTION DOCUMENTS 0 Q' I I E REVISIONS pCn / \ NO. DATE DESCRIPTION BY 1-CBU LOCATION O \ NO REVISION, ORIGINAL LLI ` I 0 02/09/2022 SUBMISSION JF/JM/HN v� (3 of MB-16 UNIT BOXS AND 1 OF 4-P TO SERVICE 43 \ \ _ REVISION PER 1ST CITY LLI HOMES AND 1 FOR HOA). — 1 08/12/2022 COMMENTS JM/HN N INSTALL CLUSTER MAIL BOX UNITS ON A CONCRETE I REVISION PER 2nd CITY U) PAD LOCATED OUTSIDE THE RIGHT OF WAY. I 2 09/23/2022 COMMENTS JM/HN F \ REVISION PER NCDOT w w 3 07/05/2023 COMMENTS JM/HN REVISION PER NCDOT Ul 4 12/15/23 AND E&SC COMMENTS JM/HN Q SCM 1 &ROADWAY 5 04/04/24 IMPROVEMENT REVISION JM/HN j CLUSTER BOX UNIT(CBU) USPS APPROVED SPECIFICATIONS- CONCRETE PAD REVISON PER NCDEQ a� -CONCRETE PAD SPECIFICATIONS- CL -ANCHORING METHODS- (MULTIPLE UNIT) 6 06/19/24 REVIEW COMMENTS JM/HN U The following documents are the only USPS approved specifications for pouring MIN MIN T 4x 0.50 DIAMETER ANCHOR BOLTS,PER CBU CLUSTER BOX UNIT (CBU) concrete pads for the anchoring of CBU's. 4.00 USE TEMPLATE TO ENSURE ALIGNMENT -ANCHORING METHODS- 41 2.00 (n CONCRETE SPECIFICATIONS FOR SINGLE UNIT CONCRETE PAD BROOM FINISH 3: CBU's must be level and mounted firmly in concrete, using one of the following I CONCRETE SPECIFICATIONS FOR DOUBLE UNIT CONCRETE PAD 24.00 16. 0 methods. Q MIN MAX O G I I + The J-bolts method is the preferred method of installation of CBU's on concrete pads; PROJ. MANAGER: HN ANCHORING METHODS FOR CENTRALIZED BOX UNITS(CBU) however,the J-bolt pattern must be accurate with the CBU pedestal plate.When DRAWN BY: JM using J-bolts, in order to prevent any damage or accidents that could result from the CHECKED BY: HN a CBU'S must be installed approximately one week prior to customer occupancy exposed bolts,consideration should be given as to the time lapse between pouring the concrete and the actual installation. Expansion anchors must be installed in CBU's must not be installed until the local USPS representative has conducted an v I I accordance with the manufacturer's instructions. SEAL Y on-site visit to ensure compliance with the official specifications. Contact the local U acceptabllee LISPS representative to have the pads inspected prior to pouring the concrete. 192.00 The use anchor bolts for the installation of CBU's on concrete pads is also MAX SEE as long as the methods decribed below are followed. NOT 4 (34.00) Lj_ CHAMFER EDGES,IN LANDSCAPE AREAS, a. HIItI KWII(bolt II, 1/2"diameter X 5-1/2"overall length `� CAR�� TOOL EDGES FLUSH WITH ADJOINING Catalog Number:000-453-696, KB II 12-512 `S°S'`°=° T CBU's must be installed facing the correct direction. CBU's installed on concrete pads SURFACES IN PAVED AREAS. Stainless Steel Catalog Number:000-454-744 ` /0% o poured behind the sidewalk should face the sidewalk. CBU's installed on concrete pads I SLOPE SURFACE.25INCH PER FOOT Minimum embedment in concrete must be no less than 3-1/2" 0 located in landscape strips between the curb and the sidewalk should face the sidewalk. 24.0o ON ALL SIDES FOR DRAINAGE a a SEAL �< U Do not install CBU facing the curb or street-causing the carrier and the customer to MIN BUTYL RUBBER PAD(WITH b. ITW Ramset Redhead Trublot,galvanized, 1/2"diameter X 7"overall length 030523 (D stand in the street to deliver or retrieve mail. METAL PEDESTAL ONLY) CBU PEDESTAL CBU MATCH EXISTING GRADE IN c. Rawl Stud, 1/2"diameter X 5 1/2"overall length,galvanized. CL OUTLINE PAVED AREAS GINS° CBU's should not be installed so close to an intersection or traffic lane that the block 4X.50 DIA Catalog Number:7324 y ANCHOR BOLTS SLOPESURFACE.25INCH PER FOOT Minimum embedment in concrete must be no less than 4" U�� visibility for approaching traffic or could be stuck by a passing motor vehicle1­1 . PER CBU ON ALL SIDES FOR DRAINAGE NG \' 0) 4X 4.50 MIN 4 RODS ON 14.00 CENTERS MAXIMUM, I) 0(0 o0 CBU's should not be located on dead-end streets where there is no safe turnaround for EACH WAY Postal delivery vehicles. OPTIONAL COMPACT GRAVEL OR CLUSTER BOX UNIT (CBU) CRUSHED STONE(OMIT WHERE -CONCRETE PAD REQUIREMENTS- USPS Contact: (n SOLID ROCK OCCURS) SCALE 0 Notify your local USPS representative immediately upon completion of the CBU 8. 0 MAXIMUM FROST DEPTH Ivy Mitchell a) installation so that we can install the arrow lock and secure the unit. x4.00 M -ALL FREE STANDING PADS MUST BE 8" THICK- AS INDICATED 806 W Central Ave. FIRM UNDISTURBED Q 8.00 MIN 11 10- All CBU compartment keys will be distributed by the builder/developer at the time of 30o SOIL O 1 UNIT SINGLE PAD 4'X 4' USPS-SUMMARY Mount Holly, NC 28120 DRAWING WELL-COMPACTED UNITS DOUBLE PAD 4'X 7' Phone: (704) 827-6415 USPS CLUSTER MAILBOX PLAN a) NOTES: 3 UNITS TRIPLE PAD 4'X 10' REQUIRED MAILBOX REQUIRED PARCEL PROVIDED MAILBOX PROVIDED PARCEL ADDITIONAL L for the box address assignments. Each homeowner should receive a copy of the Mode 1 4 UNITS QUAD PAD 4'X 13' CMB# UNIT CAPACITY UNIT CAPACITY UNIT CAPACITY UNIT CAPACITY MAILBOXES/PARCEL UNITS FAX #: (704) 827-1972 of Delivery Agreement at the time of move in. t U 2. REINFORCING STEEL RODS SHALL CONFORM TO ASTM A615,GRADE 60. #1 44 9 48 10 4/1 E-mail: ivy.d.mitchell@usps.gov 1_*1Any deviations from the USPS designated location of the CBU must not occur without 3. ***WHEN PLACING A PARCEL LOCKER AT ANY CBU LOCATION, N first receiving authorization from the local USPS representative. 4. A 3 CBU CONFIGURATION IS DEPICTED.A 2 OR 4 CBU CONFIGURATION MAY BE USED AS INCREASE THE PAD SIZE BY AN ADDITIONAL 4'X 4' *** LONG AS THEY ARE ARRANGED IN GROUPS SUCH THAT THE OVERALL DIMENSION OF THE CONCRETE BASE DOES NOT EXCEED 192 INCHES. N 0 c7 = 1 COPYRIGHT©2020 DPR ASSOCIATES,INC.THE PLAN OR DRAWING AND ANY ACCOMPANYING DOCUMENTS OR CALCULATIONS ARE THE PROPERTY OF DPR ASSOCIATES,INC.AND ARE INTENDED SOLEY FOR THE USE OF THE RECIPIENT NOTED.NO THIRD PARTY USE OR MODIFICATION IS PERMITTED WITHOUT WRITTEN AUTHORIZATION. ORIGINAL SHEET SIZE:24"X 36"