Loading...
HomeMy WebLinkAboutNCC241779_Site Plan or Location Map_20240610 NOTES: I 1. SEE DWG C1 FOR SURVEY AND DATUM INFORMATION. O (� ROP9lBR2p021 2. NO INFORMATION IN OBTAINEDTS ON FROM: FLOODPLAIN y F NI ' NBN R\OGE �b z Rp FEMA FIRM MAP:3720171800J 02� a / o EFFECTIVE DATE 5/2/2006 7 �� ♦ sa \\ 3 SITEO STOCKPILE MAY USE MATERIAL MEETING COMMON FROM EXISTING y, FILL / \ REQUIREMENTS AS FILL MATERIAL WHERE SELECT O FILL IS NOT REQUIRED. 00 I- MAINTENANCEx w 1 Zm II1 BUILDING \ C. • PROPERTY LINE,TYP. x __ PARCEL AREA:110.48 AC \ N Ir L_— SOLIDS /"]ry �I 'I�' HANDLING �, . 1 oI SMITH POND ■ p c • u.'L g'!!..``g- (EXSTORMWATER O ON �="gl //____ DETENTION) . O , •\ +� FLocc TION AND OVERFLOW WEIRS MODIFICATIONS ,•rF '�� POWER G SEDIMENTATIONS BASINS SEE DETAIL 1/DC7 1� BACKWASH r GENERATION CLARIFIERS ■ • 'FACILITY Z ___—.—_._ - ��.i--- REA 3 MAIN PLANT ENTRANCE 111 / / FUEL STORAGE .• ILI, _ t__1� •� ...I \ / (I FACILITY ^7 7( \ . a,a41, '' ��� + ��; • /// UV FACILITY I� • rZ _ -- r/ i / / PUMP STATION A 1 ` ��= —r — �'.�--I _ ` X X— RECYCLE e'.�f{/� STORMWATER OUTFALL r 00 F�Ill O�` � �? + X__ / e • :��605 PUMP STATION(,,(I IIygII II / -` AREA 1••F Og��..,._ p "�. 12MG CLEARWELL ��ulu II �� �:.� III u,u l r iu uu uu .. ` I 5MG CLEARWELL AREA 2 / I� / LIMITSOF J DISTURBANCE,x J_ �� D . TYP \ I C - '/ /// I EXISTING J o X ` `-� / G/ STOCKPILE 1' t \\ (SEE NOTE 3) 1 r I I Li f y I (( � ___Q-_ 1 WEST \\ STORAGETORAGE MAINTENANCE —M. TERMINAL \\ / \ LAGOON BLDG _ RESERVOIR U -----1 \)N' ,-..(/ i \ _\ H 7t '41 \\,... \ .,._._., ,/,..---..--__x_ - .Y, —.-- —.,(••— --X— —7 i/..._.. I \� --_/ q....''..-- CITY OF RALEIGH-PLANS AUTHORIZED FOR CONSTRUCTION p -- — i I // / / v-- Y x- --ar_ 1 Plans for the d use have been reviewed for I compliance with applicable codes.This limited review,and t'•�-- -- Y -- — propose genera p pp O authorization for construction is not to be considered to represent total compliance with all legal requirements for Et development and construction.The property owner,design Consultants,and contactors are each responsible for H re _compliance with all applicable City,State and Federal laws.This specific authorization below is not a permit,nor shall it be Z 1 a • -�y _x construed to permit any violation of City,State or Federal Law.All Construction must be in accordance with all Local,State, O and Federal Rules and Regulations.This approval of this electronic document is only valid if the document has not been U LIMITS OF DISTURBANCE:6.5 AC I PLAN modified and the dig.'signature below is valid: E ce SCALE: 1"= 150' 150 75 0 150' 0 S U SCALE:1"=150' City of Raleigh Development Approval 0 § PROJECT B.PICKETT CITY OF RALEIGH DATE: AUGUST 2023 , m a DESIGNER: HAZENNO.: 32475-003 DESIGNEDBV: C.WILSONi-ia_zei'i NORTH CAROLINA SITE — OVERALL ZDRAWN BY' A.MARCHCIVIL CONTRACT NO.: 01 DRAWING CHECKED M.SANTOWASSO E.M. JOHNSON WATER TREATMENT PLANT OVERALL SITE PLAN NUMBER: a,a HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD,SUITE 500 Ci <f IF THIS BAR DOES NOT 0 1/2" 1" J Q F 1 CONFORMED SET 08/2023 JBP MEASURE("THEN DRAWING RALEIGH,NORTH CAROLINA 27607 GENERATOR IMPROVEMENTS—PHASE 2 LL REV ISSUED FOR DATE BY IS NOT TO FULL SCALE Inii= LICENSE NO.:C-0381 C2 I z 2 U-