Loading...
HomeMy WebLinkAboutSW3240305_Plansheet - Cover Sheet_20240604 1 I 2 I 3 I 4 I 5 I 6 0 W W co w of LACKWELDER RETAIL 1OOkV SU STATION ROJECT c� J J Q 0i co N A 5605 BLACKWELDER RD CONCORD NC 28027 > w O U w a � Q 0 CABARRUS COUNTY, NORTH CAROLINA FEBRUARY 2024 > LL Q � 0w w 0- 010 0-U dQ w� �LL NCDEQ STORMWATER REVIEW �2z ui O U_Q z >N lY O Y n Of 0 2 J� w U zQ co 0 z _ coui w� U— tr GENERAL NOTES: aW PROJECT DATA o� wi PROJECT: BLACKWELDER RETAIL 1OOkV SUBSTATION PROJECT � f`. 1 . THE CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND MEASUREMENTS AND ADVISE ENGINEER OR OWNER OF ANY wo Frank Uokc - = DISCREPANCIES, BEFORE PROCEEDING WITH CONSTRUCTION WORK. w _ DEVELOPER: DUKE ENERGY — CAROLINAS WEST _ Park Lu 526 SOUTH CHURCH STREET s! :_-_ " 2. FINISH GRADE ELEVATIONS MAY BE ADJUSTED IN THE FIELD BY THE CONSTRUCTION MANAGER IN COORDINATION WITH THE � U) B CHARLOTTE, NORTH CAROLINA 28202 '4ahkv '` WWFawePark ENGINEER AS REQUIRED TO MEET FIELD CONDITIONS. O p zui Roberta MITI , CONTACT: NUMBER: 401 C23— '`' 3. PRIOR TO COMMENCING ANY DEMOLITION WORK, COORDINATE WITH THE CONSTRUCTION MANAGER AND ALL APPROPRIATE Lu 2 <a CONTACT NUMBER: 401 —323-7990 � Q UTILITY COMPANIES FOR INFORMATION ON ALL UTILITIES TO BE REMOVED, ABANDONED, OR REMAIN IN PLACE. `� z w ui ENGINEER: JACOBS ENGINEERING GROUP INC. 111 CORNING ROAD, SUITE 200 4. CONTRACTOR SHALL TAKE ADEQUATE PRECAUTIONS TO ENSURE THAT ALL UTILITIES, BOTH EXISTING AND INSTALLED, ARE o w w O �� - '� ,y = CARY, NORTH CAROLINA 27518 �� ADEQUATELY PROTECTED THROUGHOUT THE DURATION OF CONSTRUCTION AS NEEDED TO PREVENT ACCIDENTAL DISRUPTIONS 0 z `oU�a OF SERVICE. N Q w Q 919.859.5000 a >. X` o C) CONTACT: JAMIE GOLLINGS <O CONTACT NUMBER: 919.600.1163 k 5. THE CONTRACTOR SHALL VERIFY ALL EQUIPMENT CONCRETE PADS AND FOUNDATIONS WITH APPROVED VENDOR SHOP Z O" DRAWINGS. AS DEEMED NECESSARY THE DIMENSIONS SHALL BE ADJUSTED BASED ON FINAL SHOP DRAWINGS. SUCH Q O O Q $�aekwprR ADJUSTMENTS SHALL BE COORDINATED AND APPROVED BY THE ENGINEER OF RECORD. Z U) 0 a PROPERTY OWNER: HARDISTER NELSON R z_z_ HARDISTER MBE B WF 6. THE DEVELOPER AND/OR CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS PRIOR TO z o CONTACT NUMBER: s �' r- O w SITE N `i� CONSTRUCTION. z o O (n J W Q 7. ALL WORK SHALL BE PERFORMED IN ACCORDANCE TO ALL LOCAL, STATE, AND FEDERAL REGULATIONS. WORK SHALL ALSO `) _ SITE DATA age BE PERFORMED IN ACCORDANCE WITH SITE SPECIFIC OWNER REQUIREMENTS AND OSHA REQUIREMENTS FOR EXECUTING CIA Z zz z ,gy F THE WORK. o N Q— uj PROJECT PIN: 551 8-62-831 6 o 00 w U) 6�8. ALL DISTANCES, ELEVATIONS, AND DIMENSIONS ARE EXPRESSED IN FEET, UNLESS NOTED OTHERWISE. N OD PARCEL ADDRESS: 5605 BLACKWELDER RD Pharrs Will 4 z U)Lu Q w w CONCORD, NORTH CAROLINA 28027 9. ALL MEASUREMENTS ARE HORIZONTAL GROUND DISTANCES IN U.S. SURVEY FEET. `n b'� Z o DEED BOOK/PAGE: DB 4688 PG 0168 ,n o� PLAT BOOK/PAGE: BM N/A PG N/A Q;w < LU O Q 10. CONTRACTOR SHALL SUBMIT ALL MATERIALS, INSPECTIONS REPORTS, TESTING REPORTS, ETC. TO THE ENGINEER FOR 0 C) 0Y 0Y O PARCEL SIZE............................9.64 AC P"a'"''"I REVIEW. oo_ Z Q F_z =ra P z w C) �ofLL O CD U uwo TOTAL DISTURBED AREA 9.13 AC (8.98 AC PARCEL SIZE AND 0.15 AC IN NCDOT R/W) 1 1 . RESTORE ANY EXISTING SITE IMPROVEMENTS INCIDENTALLY DAMAGED DURING CONSTRUCTION. o °'E_ U D z O X Q Q O' C) TOTAL EXISTING IMPERVIOUS AREA: 0 AC rp 12. THE DESIGN PROFESSIONAL WHOSE SEAL APPEARS ON THESE DRAWINGS IS THE CIVIL ENGINEER OF RECORD. NO OTHER w V)LL�� _ o TOTAL PROPOSED IMPERVIOUS AREA 1 .76 AC (76,525 SF) PARTY MAY REVISE, ALTER, OR DELETE THESE CONSTRUCTION DOCUMENTS WITHOUT WRITTEN PERMISSION OF JACOBS OR � ww (� =Q TOTAL IMPERVIOUS AREA 1 .76 AC (18% BUA) THE ENGINEER OF RECORD. FOR THE PURPOSES OF THESE CONSTRUCTION DOCUMENTS THE ENGINEER OF RECORD AND �00 uj~ U LU ~ { ��oz� wLu Z JACOBS SHALL BE CONSIDERED THE SAME ENTITY. a N O w Q ow w ZONING: LI 13. JACOBS IS NOT RESPONSIBLE FOR CONSTRUCTION SEQUENCES, METHODS, OR TECHNIQUES IN CONNECTION WITH it z 0')z z `y Y � Q Z C SITE DATUM: NAD 83 / NAVD-88 SITE LOCATION PLAN - VICINITY MAP CONSTRUCTION. THE ENGINEER OF RECORD WILL NOT BE HELD RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO J�J J p = 2E FEMA PANEL 3710551800K (DATED 1 1/1 6/2018) CONFORM TO THE CONSTRUCTION DOCUMENTS, SHOULD ANY NON—CONFORMITIES OCCUR. z 0 rn 0 0 pLoU o ZONE 'X' NOT TO SCALE �C C)C) 0 14. THIS MAP DOES NOT REPRESENT A BOUNDARY SURVEY. PROPERTIES SHOWN HEREON ARE SUBJECT TO EASEMENTS AND O w RESTRICTIONS OF RECORD THAT WOULD BE REVEALED BY A THOROUGH TITLE SEARCH. THIS PLAT SHOULD NOT BE RELIED U o LATITUDE 35°20'20.2"N —1 o�� ui U) LONGITUDE 80`37'17.1"W UPON AS A COMPLETE RECORD OF ALL EASEMENTS THAT MAY AFFECT THESE PROPERTIES. —O O o �z�zz w RIVER BASIN YADKIN—PEE DEE CIVIL DRAWING LIST w O C-01 COVER a z C-02 EXISTING CONDITIONS & DEMOLITION PLAN O C-03 SITE & LANDSCAPING PLAN < w C-04 INITIAL EROSION CONTROL PLAN m LLJ C-05 FINAL EROSION CONTROL PLAN U' C-06 EROSION CONTROL DETAILS o 0 C-07 EROSION CONTROL DETAILS r LLJ C-08 EROSION CONTROL DETAILS Lu C-09 EROSION CONTROL DETAILS O C-10 EROSION CONTROL DETAILS Lu U w p C-11 EROSION CONTROL NOTES w LUM-1 LAND USE MAP Y U Q J m D AS NOTED VERIFY SCALE BAR IS ONE INCH ON ORIGINAL DRAWING. 0 V DATE FEBRUARY2024 PROJ D3717400 DWG C-01 SHEET 1 of 11 FILENAME: Cover Sheet.dwg PLOT DATE: 2/27/2024 PLOT TIME: 11:16:14 AM