Loading...
HomeMy WebLinkAboutNCG550839_CEI Letter and Report_20240528 DocuSign Envelope ID:5642A50E-1A224174-A220-DCOFD90FOE97 9A7>:y ROY COOPER Governor ELIZABETH S.BISER Secretary RICHAW E.ROGERS,JR. NORTH CAROLINA Director Environmental Quality May 28, 2024 Douglas Satterfield 108 Debra Drive Durham,NC 27704 Subject: Compliance Evaluation Inspection Single Family Wastewater Treatment System General NPDES Permit NCG550000 Certificate of Coverage NCG550839 Facility: 108 Debra Drive Durham County Dear Ms. Satterfield: On May 21, 2024, Donald Smith from the Raleigh Regional Office visited your single-family residence (SFR) wastewater treatment system to evaluate compliance with the subject General NPDES Permit. Your assistance during the inspection was greatly appreciated. Our records indicate the treatment system consists of a septic tank, sub-surface sand filter, tablet chlorinator, and discharge pipe. General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG550839 authorize the discharge of domestic wastewater from your treatment system to receiving waters designated as Panther Creek (classified WS-IV; NSW) in the Neuse River Basin. The authorized discharge is in accordance with the effluent limits and monitoring requirements established within the General Permit. The items below show what conditions were noted at your facility: Findings during the inspection were as follows: 1. Treatment system operation: The wastewater treatment system shall be maintained at all times to prevent seepage of sewage to the surface of the ground. 2. Pumping the septic tank: You are required to inspect the septic tank at least yearly to determine if solids must be removed or if other maintenance is necessary. Septic tanks should be pumped out every five years or when the solids level is found to be more than 1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping company can check the status periodically and determine when pumping is required. During the inspection,you provided documentation showing Scotty's Septic Service pumped out the D North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office 13800 Barren Drive I Raleigh,North Carolina 27609 919.791.4200 DocuSign Envelope ID:5B42A50E-1A22-4174-A220-DCOFD9OF9E97 Mr. Douglas Satterfield,NCG550839 May 28,2024 Page 2 of 3 septic tank in April 2024. The General NPDES Permit requires the permittee to retain records associated with sewage disposal activities for a period of at least 5 years. 3. Chlorine tablets in the chlorinator:You are reminded that it is required that chlorine tablets be maintained in the chlorinator to ensure proper disinfection of the discharged wastewater. Chlorine tablets provide effective disinfection and prevent/limit harmful bacteria from discharging to the environment. The Product label for these tablets must indicate the tablets are approved for wastewater use and not for swimming Pools. Part 1, Section D (1) of General NPDES Permit NCG550000 requires the permittee to inspect the tablet chlorinator weekly to ensure there is an adequate supply of tablets for continuous and proper operation. Section D (4) requires the permittee to maintain all system components, including disinfection units, at all times and in good operating order. The inspector did not observe any chlorine tablets in the chlorinator. Please obtain and ensure the correct type of tablets are used and maintained in the chlorinator as required by the General NPDES Permit 4. Discharge outlet location. The permittee is required to conduct a visual review of the outfall location at least twice each year(one at the time of sampling)to ensure that no visible solids or other obvious evidence of system malfunctioning is observed. Any visible signs of a malfunctioning system shall be documented,and steps taken to correct the problem. The end of discharge pipe was not visible nor accessible the day of the inspection. To comply with the general permit monitoring requirements, you need to be able to sample and analyze the effluent from your SFR system through the discharge pipe. You need to keep the area around the discharge pipe cleared of vegetation, soil, and leaves. Please take the necessary steps to ensure the discharge outlet is visible and accessible. Maintaining the area will allow you to monitor the discharge and to collect effluent samples as required by the subject permit. 5. Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements, within General Permit NCG550000 requires a permittee to sample and analyze the effluent leaving his/her treatment system prior to discharge annually. Parameters to be sampled and analyzed include Flow,BOD(Biochemical Oxygen Demand),Total Suspended Solids,Fecal Coliform, Total Residual Chlorine, Total Nitrogen, Ammonia Nitrogen and Total Phosphorous. Within 30-days of receiving this letter,please let this office know if you have monitored your effluent discharge within the last 12 months and provide this office with a copy of the lab results if you have. If you have not monitored your effluent, then please collect a representative sample of the effluent, have it analyzed by a certified commercial laboratory and submit the results to this office no later than August 30,2024. If,during this time, you are unable to collect a representative sample of the effluent discharge due to insufficient flow from the discharge pipe, then update this office with that information and continue to monitor the discharge and if conditions for sampling become favorable, then arrange to collect a sample. Failure to monitor the effluent discharge as required is a violation of NPDES General Permit NCG550000. DNorth Carolina Department of Environmcntal Quality I Division of Water Resources EQ5 Raleigh Regional Office 13900 Barrett Drive I Raleigh,North Carolina 27609 a r� —+/ 919 791.4200 DocuSign Envelope ID:5B42A50E-1A224174-A220-DCOFD90F9E97 Mr.Douglas Satterfield,NCG550839 May 28,2024 Page 3 of 3 Division records indicate the required annual fee ($60 per year) for the period ending August 31, 2024,and due September 1,2023,has been paid. There are no overdue fees for the subject COC. The wastewater treatment system should be periodically inspected to ensure the treatment components are always maintained and in good operating order. You are also reminded to maintain all monitoring data and associated maintenance records onsite for a minimum of three years and available for inspection. Within 30-days receipt of this letter,please submit a written response to this office indicating the actions you will take or have taken to comply with or resolve the issues noted items#3 above. If you have questions or comments about this inspection or the requirements to take corrective action (if applicable), then please contact Donald Smith at 919-791-4234 or donald.smith@deq.nc.gov. Sincerely, Cavas�ooeuabned W. sx -6• �1 Alti lAt�, 62916EeQM44F Vanessa E. ManueI,Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources,NCDEQ Attachment(s):EPA Water Compliance Inspection Report Cc: Laserfiche D North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office 13800 Barren Drive I Raleigh,North Carolina 27609 919.791.4200 DocuSign Envelope ID 5B42A50E-1A22-4174-A220-DCOFD90FOE97 United States Environmental Protection Agency Form Approved. EPA Washington.D.C.20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A:National Data System Coding(i.e., PCS) Transaction Code NPDES yrlmolday Inspection Type Inspector Fac Type 1 1ti l 2 15 1 3 1 NCG550839 111 121 24/05/21 j 17 18 I C I 19 I c I 201 I 21111111111111111111111111111111111111111111 r6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 OA --------—----------Reserved----------------- 67 70LJ 71 liI 72 I � 73 I 74 71 I I I 1 I 1 80 Section B: Facility Data Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Dale Permit Effective Date POTW name and NPDES permit Numbed 01:55PM 24105r21 21111l22 108 Debra Drive 108 Debra Dr Exit Time/Date Permit Expiration Date Durham NC 27704 02:16PM 24105I21 25/10/31 Name(s)of Onsite Representative(s)lTitles(s)/Phone and Fax Number(s) Other Facility Data l/1 Name,Address of Responsible Official/Title/Phone and Fax Number Douglas Satterfield,108 Debra Dr Durham NC 27704//919-956-57811 Contacted Yes Section C:Areas Evaluated During Inspection(Check only those areas evaluated) Permit E Operations&Maintenar Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/OfficeiPhone and Fax Numbers Date Donald Smith �Dowsignedby: DWR/RRO WOi919 791-42341 5/28/2024 S+n:Xl� 512ED3247FA8d7A Signature of Management 0 A Review r Agency/OfficerPhone and Fax Numbers Date FDocuSlgne by: /aun t SSa f. M.atA,u' 5/29/2024 EPA Form 3560-3(Rev 9-94)Previous ed,tions are obsolete. Page# 1 DocuSign Envelope ID:5B42A50E-lA22-4174-A220-DCOFD90F9E97 NPDES yr/mo/day Inspection Type 1 31 NCG550839�11 1 24/05/21 17 18 L� � Section D: Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) No chlorine tablest installed in chlorinator. Outlet pipe could not be located. Page# 2 DocuSign Envelope ID 5B42A50E-1A22-4174-A220-DCOFD9OF9E97 Permit: NCG550839 Owner-Facility: 108 Debra Drive Inspection Date: 05/21/2024 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? M ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ M ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑ application? Is the facility as described in the permit? M ❑ ❑ ❑ #Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: Standard general permit conditions Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? ❑ ❑ 0 ❑ Is septic tank pumped on a schedule? ■ ❑ ❑ ❑ Are pumps or syphons operating properly? ❑ ❑ ■ ❑ Are high and low water alarms operating properly? ❑ ❑ ■ ❑ Comment: Sand Filters (Low rate) Yes No NA NE (if pumps are used) Is an audible and visible alarm Present and operational? ❑ ❑ ■ ❑ Is the distribution box level and watertight? ❑ ❑ ❑ Is sand filter free of ponding? M ❑ ❑ ❑ Is the sand filter effluent re-circulated at a valid ratio? ❑ ❑ M ❑ # Is the sand filter surface free of algae or excessive vegetation? M ❑ ❑ ❑ # Is the sand filter effluent re-circulated at a valid ratio? (Approximately 3 to 1) ❑ ❑ M ❑ Comment: Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? ❑ 0 ❑ ❑ Are the tablets the proper size and type? ❑ M ❑ ❑ Number of tubes in use? 1 Page# 3 DocuSign Envelope ID:5842A50E-1A22-4174-A220-DCOFD90F9E97 Permit: NCG550839 Owner-Facility: 108 Debra Drive Inspection Date: 05/21/2024 Inspection Type: Compliance Evaluation Disinfection-Tablet Yes No NA NE Is the level of chlorine residual acceptable? ❑ 0 ❑ ❑ Is the contact chamber free of growth, or sludge buildup? N ❑ ❑ ❑ Is there chlorine residual prior to de-chlorination? ❑ ❑ ❑ Comment: No chlorination tablets installed in chlorinator Page# 4