HomeMy WebLinkAboutNCG550839_CEI Letter and Report_20240528 DocuSign Envelope ID:5642A50E-1A224174-A220-DCOFD90FOE97
9A7>:y
ROY COOPER
Governor
ELIZABETH S.BISER
Secretary
RICHAW E.ROGERS,JR. NORTH CAROLINA
Director Environmental Quality
May 28, 2024
Douglas Satterfield
108 Debra Drive
Durham,NC 27704
Subject: Compliance Evaluation Inspection
Single Family Wastewater Treatment System
General NPDES Permit NCG550000
Certificate of Coverage NCG550839
Facility: 108 Debra Drive
Durham County
Dear Ms. Satterfield:
On May 21, 2024, Donald Smith from the Raleigh Regional Office visited your single-family
residence (SFR) wastewater treatment system to evaluate compliance with the subject General
NPDES Permit. Your assistance during the inspection was greatly appreciated.
Our records indicate the treatment system consists of a septic tank, sub-surface sand filter, tablet
chlorinator, and discharge pipe.
General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG550839 authorize
the discharge of domestic wastewater from your treatment system to receiving waters designated
as Panther Creek (classified WS-IV; NSW) in the Neuse River Basin. The authorized discharge
is in accordance with the effluent limits and monitoring requirements established within the
General Permit. The items below show what conditions were noted at your facility:
Findings during the inspection were as follows:
1. Treatment system operation: The wastewater treatment system shall be maintained at all
times to prevent seepage of sewage to the surface of the ground.
2. Pumping the septic tank: You are required to inspect the septic tank at least yearly to
determine if solids must be removed or if other maintenance is necessary. Septic tanks
should be pumped out every five years or when the solids level is found to be more than 1/3
of the liquid depth in the septic tank compartment, whichever is greater. A pumping
company can check the status periodically and determine when pumping is required. During
the inspection,you provided documentation showing Scotty's Septic Service pumped out the
D North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barren Drive I Raleigh,North Carolina 27609
919.791.4200
DocuSign Envelope ID:5B42A50E-1A22-4174-A220-DCOFD9OF9E97
Mr. Douglas Satterfield,NCG550839
May 28,2024 Page 2 of 3
septic tank in April 2024. The General NPDES Permit requires the permittee to retain
records associated with sewage disposal activities for a period of at least 5 years.
3. Chlorine tablets in the chlorinator:You are reminded that it is required that chlorine tablets
be maintained in the chlorinator to ensure proper disinfection of the discharged
wastewater. Chlorine tablets provide effective disinfection and prevent/limit harmful
bacteria from discharging to the environment. The Product label for these tablets must
indicate the tablets are approved for wastewater use and not for swimming Pools. Part 1,
Section D (1) of General NPDES Permit NCG550000 requires the permittee to inspect the
tablet chlorinator weekly to ensure there is an adequate supply of tablets for continuous and
proper operation. Section D (4) requires the permittee to maintain all system components,
including disinfection units, at all times and in good operating order. The inspector did not
observe any chlorine tablets in the chlorinator. Please obtain and ensure the correct type of
tablets are used and maintained in the chlorinator as required by the General NPDES
Permit
4. Discharge outlet location. The permittee is required to conduct a visual review of the outfall
location at least twice each year(one at the time of sampling)to ensure that no visible solids
or other obvious evidence of system malfunctioning is observed. Any visible signs of a
malfunctioning system shall be documented,and steps taken to correct the problem. The end
of discharge pipe was not visible nor accessible the day of the inspection. To comply with
the general permit monitoring requirements, you need to be able to sample and analyze the
effluent from your SFR system through the discharge pipe. You need to keep the area around
the discharge pipe cleared of vegetation, soil, and leaves. Please take the necessary steps to
ensure the discharge outlet is visible and accessible. Maintaining the area will allow you to
monitor the discharge and to collect effluent samples as required by the subject permit.
5. Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements,
within General Permit NCG550000 requires a permittee to sample and analyze the effluent
leaving his/her treatment system prior to discharge annually. Parameters to be sampled and
analyzed include Flow,BOD(Biochemical Oxygen Demand),Total Suspended Solids,Fecal
Coliform, Total Residual Chlorine, Total Nitrogen, Ammonia Nitrogen and Total
Phosphorous. Within 30-days of receiving this letter,please let this office know if you have
monitored your effluent discharge within the last 12 months and provide this office with a
copy of the lab results if you have. If you have not monitored your effluent, then please
collect a representative sample of the effluent, have it analyzed by a certified commercial
laboratory and submit the results to this office no later than August 30,2024. If,during this
time, you are unable to collect a representative sample of the effluent discharge due to
insufficient flow from the discharge pipe, then update this office with that information and
continue to monitor the discharge and if conditions for sampling become favorable, then
arrange to collect a sample. Failure to monitor the effluent discharge as required is a violation
of NPDES General Permit NCG550000.
DNorth Carolina Department of Environmcntal Quality I Division of Water Resources
EQ5 Raleigh Regional Office 13900 Barrett Drive I Raleigh,North Carolina 27609
a r� —+/ 919 791.4200
DocuSign Envelope ID:5B42A50E-1A224174-A220-DCOFD90F9E97
Mr.Douglas Satterfield,NCG550839
May 28,2024 Page 3 of 3
Division records indicate the required annual fee ($60 per year) for the period ending August 31,
2024,and due September 1,2023,has been paid. There are no overdue fees for the subject COC.
The wastewater treatment system should be periodically inspected to ensure the treatment
components are always maintained and in good operating order. You are also reminded to
maintain all monitoring data and associated maintenance records onsite for a minimum of three
years and available for inspection.
Within 30-days receipt of this letter,please submit a written response to this office indicating
the actions you will take or have taken to comply with or resolve the issues noted items#3 above.
If you have questions or comments about this inspection or the requirements to take corrective
action (if applicable), then please contact Donald Smith at 919-791-4234 or
donald.smith@deq.nc.gov.
Sincerely,
Cavas�ooeuabned W.
sx
-6• �1 Alti lAt�,
62916EeQM44F
Vanessa E. ManueI,Assistant Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources,NCDEQ
Attachment(s):EPA Water Compliance Inspection Report
Cc: Laserfiche
D North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barren Drive I Raleigh,North Carolina 27609
919.791.4200
DocuSign Envelope ID 5B42A50E-1A22-4174-A220-DCOFD90FOE97
United States Environmental Protection Agency Form Approved.
EPA Washington.D.C.20460 OMB No.2040-0057
Water Compliance Inspection Report Approval expires 8-31-98
Section A:National Data System Coding(i.e., PCS)
Transaction Code NPDES yrlmolday Inspection Type Inspector Fac Type
1 1ti l 2 15 1 3 1 NCG550839 111 121 24/05/21 j
17 18 I C I 19 I c I 201 I
21111111111111111111111111111111111111111111 r6
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 OA --------—----------Reserved-----------------
67 70LJ 71 liI 72 I � 73 I 74 71 I I I 1 I 1 80
Section B: Facility Data
Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Dale Permit Effective Date
POTW name and NPDES permit Numbed
01:55PM 24105r21 21111l22
108 Debra Drive
108 Debra Dr Exit Time/Date Permit Expiration Date
Durham NC 27704 02:16PM 24105I21 25/10/31
Name(s)of Onsite Representative(s)lTitles(s)/Phone and Fax Number(s) Other Facility Data
l/1
Name,Address of Responsible Official/Title/Phone and Fax Number
Douglas Satterfield,108 Debra Dr Durham NC 27704//919-956-57811 Contacted
Yes
Section C:Areas Evaluated During Inspection(Check only those areas evaluated)
Permit E Operations&Maintenar
Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s)and Signature(s)of Inspector(s) Agency/OfficeiPhone and Fax Numbers Date
Donald Smith �Dowsignedby: DWR/RRO WOi919 791-42341 5/28/2024 S+n:Xl�
512ED3247FA8d7A
Signature of Management 0 A Review r Agency/OfficerPhone and Fax Numbers Date
FDocuSlgne by:
/aun t SSa f. M.atA,u' 5/29/2024
EPA Form 3560-3(Rev 9-94)Previous ed,tions are obsolete.
Page# 1
DocuSign Envelope ID:5B42A50E-lA22-4174-A220-DCOFD90F9E97
NPDES yr/mo/day Inspection Type 1
31 NCG550839�11 1 24/05/21 17 18 L� �
Section D: Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
No chlorine tablest installed in chlorinator. Outlet pipe could not be located.
Page# 2
DocuSign Envelope ID 5B42A50E-1A22-4174-A220-DCOFD9OF9E97
Permit: NCG550839 Owner-Facility: 108 Debra Drive
Inspection Date: 05/21/2024 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? M ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ M ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑
application?
Is the facility as described in the permit? M ❑ ❑ ❑
#Are there any special conditions for the permit? ❑ 0 ❑ ❑
Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑
Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑
Comment: Standard general permit conditions
Septic Tank Yes No NA NE
(If pumps are used) Is an audible and visual alarm operational? ❑ ❑ 0 ❑
Is septic tank pumped on a schedule? ■ ❑ ❑ ❑
Are pumps or syphons operating properly? ❑ ❑ ■ ❑
Are high and low water alarms operating properly? ❑ ❑ ■ ❑
Comment:
Sand Filters (Low rate) Yes No NA NE
(if pumps are used) Is an audible and visible alarm Present and operational? ❑ ❑ ■ ❑
Is the distribution box level and watertight? ❑ ❑ ❑
Is sand filter free of ponding? M ❑ ❑ ❑
Is the sand filter effluent re-circulated at a valid ratio? ❑ ❑ M ❑
# Is the sand filter surface free of algae or excessive vegetation? M ❑ ❑ ❑
# Is the sand filter effluent re-circulated at a valid ratio? (Approximately 3 to 1) ❑ ❑ M ❑
Comment:
Disinfection-Tablet Yes No NA NE
Are tablet chlorinators operational? ❑ 0 ❑ ❑
Are the tablets the proper size and type? ❑ M ❑ ❑
Number of tubes in use? 1
Page# 3
DocuSign Envelope ID:5842A50E-1A22-4174-A220-DCOFD90F9E97
Permit: NCG550839 Owner-Facility: 108 Debra Drive
Inspection Date: 05/21/2024 Inspection Type: Compliance Evaluation
Disinfection-Tablet Yes No NA NE
Is the level of chlorine residual acceptable? ❑ 0 ❑ ❑
Is the contact chamber free of growth, or sludge buildup? N ❑ ❑ ❑
Is there chlorine residual prior to de-chlorination? ❑ ❑ ❑
Comment: No chlorination tablets installed in chlorinator
Page# 4