Loading...
HomeMy WebLinkAboutRobeson_Well Abandonment_20240514 (4) WELL ABANDONMENT RECORD For Internal Use ONLY: i 1.Well Contractor Information: WELL ABANDONMENT DETAILS I Nathaniel Newman 7a.For Geoprobe/DPT or Closed-Loop!Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GW-30 its eeded. Indicate TOTAL NUMBER of 4630C wells abandoned: P NC Well Contractor Certification Number 7b.Approximate volume of water remaining in well(s): (gal.) CATLIN Engineers and Scientists FOR WATER SUPPLY WELLS ONLY: P Y Com an Name 7c.Type of disinfectant used: 2.Well Construction Permit#: List all applicable srell construction permits(i.e.U1C,County,State,Variance,etc)ijknown 7d.Amount of disinfectant used: 3.Well use(check well use): Water Supply Well: 7e.Sealing materials used(check all that apply): []Agricultural ❑Municipal/Public ❑Neat Cement Grout C Bentonite Chips or Pellets ❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑,Dry Clay ❑Industrial/Commercial El Residential Water Supply(shared) ❑ Concrete Grout ❑ Drill Cuttings ❑Irrigation ❑ Specialty Grout ❑Gravel Non-Water Supply Well: ❑ Bentonite Slurry e Other(explain under 7g) RMonitoring ❑Recovery Injection Well: 7f.For each material selected above,provide amount of materials used: ❑Aquifer Recharge ❑GroundwaterRemediation Bentonite 30lbs ❑Aquifer Storage and Recovery ❑Salinity Barrier ❑Aquifer Test ❑Stor'mwaterDrainage Concrete 25lbs ❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of the abandonment procedure: ❑Geothermal(Closed Loop) l7Tracer ' ❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) All well materials abandoned in place using hydrated bentonite to approximately six inches 4.Date well(s)abandoned:.4/17/2024 - 1'' ,- below land surface. Concrete was useiito brim.,,r,�,. Sa.Well location: remaining opening to grade. r._,L Nic's Properties, Inc. 00-0-0000018540 j Facility/Owner Name Facility ID#(if applicable) 8.Certification: r 11 II M 150 West Martin Luther King Jr. Drive C�1F9)20? Physical Address,City,and Zip Signature of Certified Well Contractor or Well Owner Date Robeson 839549600700 By signing this form, /hereby certify that the wells) was (were) abandoned in County Parcel Identification No.(PIN) accordance tbith 15A NCAC 02C.0100 or 2C.0200 Well Construction Standards and that a copy of This record has been provided to the well owner. 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field,one lar/long is sufficient) 9.Site diagram or additional well details: 34.736059 N -79.350995 W You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELLS)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach hell construction records)ifavailable.For multiple injection or non-watersupply wells ONLY with the same construction.abandonment,you can submit one form. 10a. For All Wells: Submit this form'within 30 days of completion of well 6a.Well ID#: MW-2 abandonment to the following: Division of Water Resources,Information Processing Unit, 6b.Total well depth: 16 (ft) 1617 Mail Service Center,Raleigh,NC 27699-1617 10b.For Injection Wells: in addition;to sending the form to the address in 1Oa 6c.Borehole diameter: 8.25 (in) above, also submit one copy of this foiim within 30 days of completion of well abandonment to the following: l 6d.Water level below ground surface: 4.99 Division of Water Resources,Underground injection Control Program, (ft.) 1636 Mail Service Center,Raleigh,NC 27699-1636 6e.Outer casing length(if known): Unknown (ft) 10c.For Water Supply&Injection Wells: In addition to sending the form to the address(es)above,also submit one copy of this form within 30 days of completion of well abandonment to the county heklth department of the county where 6f.Inner casing/tubing length(if known): 6 abandoned. i 6g.Screen length(if known): 10 I Form GW-30 North Carolina Department of Environmental Quality-Division of Watcr Resources Revised 2-22-2016