Loading...
HomeMy WebLinkAboutGuilford_Well Abandonment_20240429 (2) WELL ABANDONMENT RECORD For Internal Use ONLY: This form can be used for single or multiple wells 1.Well Contractor Information: WELL ABANDONMENT DETAILS Lawrence D. Oppef 7a.Number of wells being abandoned: 1 Well Contractor Name(or well owner personally abandoning well on his/her property) For multiple injection or non-water supply wells ONLY with the same 3322-A construciionlabandonmem,you can submit one form. NC Well Contractor Certification Number 7b.Approximate volume of water;remaining in well(s): 0 (gal.) Regional Probing Services FOR WATER SUPPLY WELLS ONLY: Company Name 7c.Type of disinfectant used: 2.Well Construction Permit#: List all applicable well construction permits(i.e.County,State,Variance,etc.)if known 7d.Amount of disinfectant used I 3.Well use(check well use): Water Supply Well: 7e.Sealing materials used(check all that apply): ❑Agricultural ❑MunicipaUPublic ❑Neat Cement Grout 0 Bentonite Chips or Pellets ❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑ Dry Clay ❑Industrial/Commercial ❑Residential Water Supply(shared) ❑ Concrete Grout ❑ Drill Cuttings, ❑Irri ation ❑ Specialty Grout ❑Gravel Non-Water Supply Well: ❑ Bentonite Slurry ❑Other(explain under 7g) OMonitoring ❑Recovery Injection Well: 7E For each material selected above,provide amount of materials used: ❑Aquifer Recharge ❑Groundwater Remediation bentonite chips: 1.6 Ibs/ft(561bs) ❑Aquifer Storage and Recovery []Salinity Barrier ❑Aquifer Test ❑Stormwater Drainage ❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of the abandonment procedure: ❑Geothermal(Closed Loop) []Tracer Filled/hydrated from bottom-up. Capped with concrete. ❑Geothermal(Heating/Cooling Return) ❑Other(explain under 7g) - H 4.Date well 3/25/2024s)abandoned: 0xZZ Sa.Well location: APR 2 7r7r Guilford College Family Fare BP#271 Facility/Owner Name Facility ID# ifa livable 8•Certification:/% 628 Guilford College Road, Greensboro Lawrence OpDpDe 3/28/2024 Physical Address,City,and Zip Signature of Certified Well Contractor or Well Owner Date Guilford By signing this form, I hereby certify that the well(s)was (were) abandoned in County Parcel Identification No.(PIN) accordance with 15A NCAC 02C.0100 or 2C.0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (ifwell field,one lat/long is sufficient) 9.Site diagram or additional well details: 36.063796 79.907281 You may use the back of this page to provide additional well site details or well N W abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach well construction record(s)if available. For multiple injection or non-rater supply wells ONLY with the same consiructionlahandonment,you can submit oneform. 10a. For All Wells: Submit this form within 30 days of completion of well 6a.Well ID#• MW-1 abandonment to the following: Division of Water Quality,Information Processing Unit, 1617 Mail Service C,enter,Raleigh,NC 27699-1617 6b.Total well depth: 35 (ft.) 10b.For Infection Wells: In addition to sending the form to the address in 10a well I.D.=2.0 above,also submit one copy of this form within 30 days of completion of well 6c.Borehole diameter: (in.) abandonment to the following: 23 Division of Water Quality,Underground Injection Control Program, 6d.Water level below ground surface: (ft) 1636 Mail Service Center,Raleigh,NC 27699-1636 loc. For Water Supply&Injection Wells: In addition to sending the form to 6e.Outer casing length(if known): (ft.) the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 6f.Inner casing(tubing length(if known): 15 (ft.) 6g.Screen length(if known): 20 (ft.) Form GW-30 North Carolina Department of Environment and Natural Resources—Division of Water Quality Revised March 2013