HomeMy WebLinkAboutSW6240103_Supplement-EZ Form_20240425 SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1 Project Name Leander Lee Preserve Subdivision
( 2 ;Project Area(ac)
56
3 Coastal Wetland Area(ac) 0
4 i Surface Water Area(ac) 0 16
f5 Is this project High or Low Density? Low $
( 6 *Does this project use an off site SCM? NO.. ... .._..._ _ 1i
COMPLIANCE WITH 02H 1003(4) ;
. , .. mow,.
1 7 Width of vegetated setbacks provided(feet) 30
8 Will the vegetated setback remain vegetated? Yes 3
9 ,If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A j
1 10 Is streambank stabilization proposed on this project? No j
NUMBER AND TYPE OF SCMs
0 11 Infiltration System
l 12 Bioretention Cell
13 Wet Pond
14 Stormwater Wetland
15 Permeable Pavement
16 ::Sand Filter 1
17 Rainwater Harvesting(RWH) i
18 Green Roof
19 :Level Spreader-Filter Strip(LS-FS) 1
1 20 Disconnected Impervious Surface(DIS)
21 Treatment Swale
22 ;Dry Pond
p
23 StormFilter
24 Silva Cell
25 ,Bayfilter
(
26 Filterra
FORMS LOADED
DESIGNER CERTIFICATION-- _ --o— �—
i 27 :,Name and Title: C. Scott Brown, PE E
I y
28 Organization: 4D Site Solutions, Inc.
29 ;Street address: 409 Chicago Drive-Ste 112
30 City,State,Zip: Fayetteville, NC 28306 3
31 'Phone number(s): 910-426-6777 t
+ 32 ;Email sbrown(4dsitesolutions.com 1
Certification Statement:
I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the
information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,specifications,
operation and maintenance agreements and other supporting information are consistent with the information provided here.
Designer
-CN Rp ' (:\ n
GFE� �
Ip• �2 ' \ r V�
• LA _ Signature of esigner
L •
027452 • -
'',,,Seal,,```` 04 , Date t ,
DRAINAGE AREAS
1 rls this a high density project? No
2 f If so, number of drainage areas/SCMs 0
3_ Does this project have low density areas? Yes
4 I If so,number of low density drainage areas 1
1.
Is all/part of this project subject to previous rule
t. 5 :versions? No
FORMS IOADED
!DRAINAGE AREA INFORMATION Entire Site LD 1
4 !Type of SCM Low Density Low Density
5 !Total drainage area(sq ft) 4 068z.504 4 068 504
6 IOnsite drainage area(sq ft) 4 068,504 4 068 504
7 Offsite drainage area(sq ft) 0 t 0
8 !Total BUA in project(sq ft) tI 974284 sf 974284 sf
BUA on subdivided lots(subject to New
rtg)(sgft1 725200 sf _.. 725200 sf __ I
9 ?permtten
I New BUA not on subdivided lots(subject to
1 10 I permittin_gl(sf) 249084 sf 249084 sf
11 Offsite BUA(sq ft) sf
12 (Breakdown of new BUA not on subdivided lots:It
t Parking(sq ft)
I Sidewalk(sq ft) 4
j_ Roof(sq_ft)
r _
Roadway(sq ft) 249084 sf 249084 sf
!, -Future(sq ft).
1 Other, please specify in the comment box i.
;below(sq ft) t t
;New infiltrating permeable pavement on f ^; t
1 13 ;subdivided lots(sq ft) ;
t
New infiltrating permeable pavement not on
r
1 14 subdivided lots(sq ft) t a
z Existing BUA that will remain(not subject to t lt, I
1.15 ;permitting)(sq ft) t
at
i 16 !Existing BUA that is already permitted(sq ft)
17 !Existing BUA that will be removed(sq ft)
18 I Percent BUA 24% 24%
- (
19 1Design storm(inches)
20 Design volume of SCM(cu ft) f
i21 !Calculation method for design volume
P
lease use this spTION
ADDITIONAL INFORMATION
ace to provide any additional information about the w
22 !drainage area(s):
i,
t
P
i
LOW DENSITY
DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003
1 Is project below density thresholds set forth in the applicable stormwater rule? Yes
2 Does project maximize dispersed flow and minimize channelization of flow? Yes
i 3 ,Has the use of piping been minimized per.1003(2)(c)? Yes r
4 Side slopes of the vegetated conveyances(H:V) 3
5 Maximum velocity in the vegetated conveyances during the 10-year storm? 4.43 �
6 ,Are curb outlet swales proposed? No t
a
7 Maximum longitudinal slope of curb outlet swale(s)(%) N/A I
8 Bottom width of curb outlet swale(s)(feet) N/A 1
9 Maximum side slope of curb outlet swale(s)(H:V) N/A
10 Minimum length of curb outlet swale(s)(feet) N/A
11 Are treatment swales used instead of curb outlet swales?
12 Is stormwater released at the edge of the setback as dispersed flow? N/A t
13 Have stormwater outlets been designed to prevent downslope erosion? Yes a,
14 Are variations to rule.1003 proposed? No
ADDITIONAL INFORMATION- -w .u-� .�.,., ,,,� . �.,..,�,�..,� ..
15 Please use this space to provide any additional information about this low density project:
►
Swale Drainage . BUA i Pervious
Area : Q Slope V,,,,,,, V,:,„„ Flow depth
# act (ac) fact area . o WO (%) Ifps) (fps) (ft)
1 0.72 0.17 0.56 0.45 2.54 2.35 5.00 2.26 0.53
2 0.99 0.15 0.84 0.40 3.09 0.90 5.00 1.37 0.78
3 1.47 0.23 1.24 0.40 4.60 1.58 5.00 2.21 0.75
4 2.32 0.54 1.78 0.45 6.53 1.65 5.00 2.56 0.84
5 5.35 0.82 4.53 0.40 11.30 0.53 5.00 1.59 1.46
__.6 8.18 1.26 6.92 0.40 15.68 2.50 5.00 4.43 1.01
7 8.69 1.34 7.35 0.40 16.66 0.57 5.00 1.89 1.41
8 0.23 , 0.05 0.18 0.45 0.81 2.53 5.00 1.58 0.34
9 0.15 0.06 0.09 0.55 0.65 0.55 5.00 0.60 0.52
10 2.08 0.48 1.60 0.45 5.85 1.00 5.00 1.79 0.76
11 0.11 0.04 0.07 0.55 0.47 0.75 5.00 0.64 0.42
12 0.18 . - 0.07 0.11 0.55 0.77 0.75 5.00 0.76 0.50
13 4.09 0.94 ' 3.15 0.45 9.72 i 0.90 5.00 2.03 0.97
14 1.51 0.58 0.93 0.55 4.39 1.95 5.00 2.46 0.69
15 1.16 0.18 0.98 0.40 3.63 1.79 5.00 2.18 0.67
16 1.14 0.18 0.96 0.40 3.57 1.79 5.00 2.17 0.66
17 1.61 0.25 1.36 0.40 5.04 0.75 5.00 1.47 0.99
18 0.30 0.15 0.18 0.55 1.29 1.48 5.00 1.36 0.48
19 1.19 0.46 0.73 0.55 3.46 0.53 5.00 1.05 0.97
20 0.77 0.30 0.47 0.55 2.65 1.65 5.00 1.87 0.61
21 0.41 0.16 0.25 0.55 1.76 1.58 5.00 1.58 0.53
23
24 2.68 0.62 2.06 0.45 7.54 3.50 5.00 4.00 0.53
25 1.98 0.61 1 37 0.50 6.19 3.04 5.00 3.59 0.68
26 1.55 0.24 1.31 0.40 4.85 1.24 5.00 I 1.95 0.83
27 .
28 _._._.
29
30