Loading...
HomeMy WebLinkAboutNC0043532_Application (ATC)_20240415DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT FORM ATC 10-23 SECTION 1: INSTRUCTIONS AND INFORMATION A. The Division of Water Resources will accept this application package for review only if all of the items are provided and the application is complete. Failure to submit all of the required items will result in the application package being returned as incomplete per 15A NCAC 02T .0105(b). B. A check or money order must be submitted in the amount of $1000.00 (except minor modifications) dated within 90 days of application submittal and made payable to North Carolina Department of Environmental Quality (NCDEQ). C. Plans and specifications must be prepared in accordance with 15 NCAC 02H. 0100, 15A NCAC 02T, North Carolina General Statute 133-3, North Carolina General Statute 143-215.11 and Division of Water Resources Minimum Design Criteria for NPDES Wastewater Treatment Facilities. D. The plans and specifications submitted must represent a completed final design that is ready to advertise for bid. E. Any content changes made to this Form ATC 10-23 shall result in the application package being returned. F. The Applicant shall submit ONE ORIGINAL and ONE DIGITAL COPY (CD) of the application, all supporting documentation and attachments. All information must be submitted bound or in a 3-ring binder, with a Section tab for each Section, except the Engineering Plans. G. Check the boxes below to indicate that the information is provided and the requirements are met. H. If attachments are necessary for clarity or due to space limitations, such attachments are considered part of the application package and must be numbered to correspond to the item referenced. I. For any project that requires review under the State Environmental Policy Act (SEPA), an Authorization to Construct cannot be issued prior to the completion of a State Clearinghouse advertisement period for a FONSI, EIS, etc. unless the project qualifies for a Determination of Minor Construction Activity or the funding entity specifies that this requirement does not apply. J. For more information, visit the Division of Water Resources web site at: hltp://portal.ncdenr.orfz/web/wq/swp//ps/npdes. K. In addition to this Authorization to Construct, the Applicant should be aware that other permits may be required from other Sections of the Division of Water Resources (for example: reclaimed water facilities permits; Class A or B biosolids residuals permit). SECTION 2: APPLICANT INFORMATION AND PROJECT DESCRIPTION A. APPLICANT Applicant's name Stanly County Utilities Signature authority's name per 15A NCAC 02T .0106(b) Duane Wingo Signature authority's title Utilities Director Complete mailing address 1000 N. 1 st Street, Suite 12, Albemarle, NC 28001 Telephone number (704) 986-3686 Email address dwingo@stanlycountync.gov B. PROFESSIONAL ENGINEER Professional Engineer's name Carl Scharfe Professional Engineer's title Project Manager/Senior Process Engineer North Carolina Professional Engineer's License No. 040525 Firm name The Wooten Company Firm License number F-0115 Complete mailing address 120 N. Boylan Ave, Raleigh, NC 27603 Telephone number 919-828-0531 Email address cscharfe@thewootencompany.com APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC 10-23) Page 1 DWR Division of Water Resources C. NPDES PERMIT State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT FORM ATC 10-23 NPDES Permit number NCO043532 Current Permitted flow (MGD) — include permit Current — 1.2 MGD, Future Flow Sheet — 2.5 MGD flow phases if applicable D. PROJECT DESCRIPTION Provide a brief description of the project: This project will expand the treatment capacity at the West Stanly WWTP from 1.2 MGD to 2.5 MGD. The project will include: relocation of the existing Headworks to the front of the expanded WWTP; installation of two new 1.5-MGD Equalization (EQ) Tanks and EQ Pump Station; installation of two new 1.25-MGD Aeration Basins; new Caustic Feed System for pH adjustment; installation of a new Polymer Feed System; installation of a new 75-ft diameter Clarifier with its own dedicated RAS/WAS Pump Station; expansion of the capacity of the existing RAS/WAS Pump Station; installation of new Effluent Disc Filters; expansion of the existing Chlorine Contact Basin; expansion of the capacity of the Effluent Pump Station; the repurpose of the existing Aeration Basins and the existing 50-ft diameter Clarifier for sludge digestion and holding; replacement of the existing aerators in the existing Aerobic Digester; construction of a new Process and Maintenance Building; and upgrades to the existing Control/Laboratory Building. A NPDES permit for the expanded flow of 2.5 MGD was issued December 11, 2023. SECTION 3: APPLICATION ITEMS REOUIRED FOR SUBMITTAL FOR ALL PROJECTS A. Cover Letter ® The letter must include a request for the Authorization to Construct; the facility NPDES Number; a brief project description that indicates whether the project is a new facility, facility modification, treatment process modification, or facility expansion; the construction timeline; and a list of all items and attachments included in the application package. ❑ If any of the requirements of 15 NCAC 02H. 0100, 15A NCAC 02T, North Carolina General Statute 133-31 North Carolina General Statute 143-215.1, and Division of Water Resources Minimum Design Criteria for NPDES Wastewater Treatment Facilities are not met by the proposed design, the letter must include an itemized list of the requirements that are not met. ❑ If the project is funded by American Rescue Plan Act (ARPA) funds, please include the ARPA project number in the cover letter and here B. NPDES Permit ® Submit Part I of the Final NPDES permit for this facility that includes Part A (Effluent Limitations and Monitoring Requirements) for the monthly average flow limit that corresponds to the work that is requested for this project. C. Special Order by Consent ❑ If the facility is subject to any Special Orders by Consent (SOC), submit the applicable SOC. ® Not Applicable. D. Finding of No Significant Impact or Record of Decision ® Submit a copy of the Finding of No Significant Impact or Record of Decision for this project. ❑ Provide a brief description of any of the mitigating factors or activities included in the approved Environmental Document that impact any aspect of design of this project, if not specified in the Finding of No Significant Impact or Record of Decision. ❑ Not Applicable. APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC 10-23) Page 2 State of North Carolina DWR Department of Environmental Quality Division of Water Resources Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT FORM ATC 10-23 E. Engineering Plans ® Per 15A NCAC 02T .0504(c)(1), submit one set of detailed plans that have been signed, sealed and dated by a North Carolina Licensed Professional Engineer. ® Per 21 NCAC 56 .1103(a)(6), the name, address and License number of the Licensee's firm shall be included on each sheet of the engineering drawings. ® Plans must be labeled as follows: FINAL DRAWING — FOR REVIEW PURPOSES ONLY — NOT RELEASED FOR CONSTRUCTION. ® 15A NCAC 02H .0124 requires multiple (dual at a minimum) components such as pumps, chemical feed systems, aeration equipment and disinfection equipment. Is this requirement met by the design? ® Yes or ❑ No. If no, provide an explanation: Plans shall include: ® Plans for all applicable disciplines needed for bidding and construction of the proposed project (check as appropriate): ® Civil ❑ Not Applicable ® Process Mechanical ❑ Not Applicable ® Structural ❑ Not Applicable ® Electrical ❑ Not Applicable ® Instrumentation/Controls ❑ Not Applicable ® Architectural ❑ Not Applicable ® Building Mechanical ❑ Not Applicable ® Building Plumbing ❑ Not Applicable ® Plan and profile views and associated details of all modified treatment units including piping, valves, and equipment (pumps, blowers, mixers, diffusers, etc.) ® Are any modifications proposed that impact the hydraulic profile of the treatment facility? ® Yes or ❑ No. If yes, provide a hydraulic profile drawing on one sheet that includes all impacted upstream and downstream units. The profile shall include the top of wall elevations of each impacted treatment unit and the water surface elevations within each impacted treatment unit for two flow conditions: (1) the NPDES permitted flow with all trains in service and (2) the peak hourly flow with one treatment train removed from service. ® Are any modifications proposed that impact the process flow diagram or process flow schematic of the treatment facility? Yes or ❑ No. If yes, provide the process flow diagram or process flow schematic showing all modified flow paths including aeration, recycle/return, wasting, and chemical feed, with the location of all monitoring and control instruments noted. F. ® Engineering Specifications ® Per 15A NCAC 02T .0504(c)(2), submit one set of specifications that have been signed, sealed and dated by a North Carolina Licensed Professional Engineer. ® Specifications must be labeled as follows: FINAL SPECIFICATIONS — FOR REVIEW PURPOSES ONLY — NOT RELEASED FOR CONSTRUCTION. Specifications shall include: ® Specifications for all applicable disciplines needed for bidding and construction of the proposed project (check as appropriate): ® Civil ❑ Not Applicable ® Process Mechanical ❑ Not Applicable ® Structural ❑ Not Applicable ® Electrical ❑ Not Applicable ® Instrumentation/Controls ❑ Not Applicable ® Architectural ❑ Not Applicable APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC 10-23) Page 3 DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT FORM ATC 10-23 ® Building Mechanical ❑ Not Applicable ® Building Plumbing ❑ Not Applicable ® Detailed specifications for all treatment units and processes including piping, valves, equipment (pumps, blowers, mixers, diffusers, etc.), and instrumentation. ® Means of ensuring quality and integrity of the finished product including leakage testing requirements for structures and pipelines, and performance testing requirements for equipment. ® Bid Form for publicly bid projects. G. Construction Sequence Plan ® Construction Sequence Plan such that construction activities will not result in overflows or bypasses to waters of the State. The Plan must not imply that the Contractor is responsible for operation of treatment facilities. List the location of the Construction Sequence Plan as in the Engineering Plans or in the Engineering Specifications or in both: Section 01 12 00, Summary of Work Paragraph 1.03. H. Engineering Calculations ® Per 15A NCAC 02T .0504(c)(3), submit one set of engineering calculations that have been signed, sealed and dated by a North Carolina Licensed Professional En ig neer; the seal, signature and date shall be placed on the cover sheet of the calculations. For new or expanding facilities and for treatment process modifications that are included in Section 4.C, the calculations shall include at a minimum: ® Demonstration of how peak hour design flow was determined with a justification of the selected peaking factor. ® Influent pollutant loading demonstrating how the design influent characteristics in Section 4.13.2 of this form were determined. ® Pollutant loading for each treatment unit demonstrating how the design effluent concentrations in Section 4.13.2 of this form were determined. ® Hydraulic loading for each treatment unit. ® Sizing criteria for each treatment unit and associated equipment (blowers, mixers, pumps, etc.) ® Total dynamic head (TDH) calculations and system curve analysis for each pump specified that is included in Section 4.C.6. ® Buoyancy calculations for all below grade structures. ® Supporting documentation that the specified auxiliary power source is capable of powering all essential treatment units. I. Permits ® Provide the following information for each permit and/or certification required for this project: Permit/Certification Not Applicable Date Submitted Date Approved Permit/ Certification Number If Not Issued Provide Status and Expected Issuance Date Dam Safety x Soil Erosion and Sediment Control 2/20/24 6/21/24 USCOE / Section 404 Permit x Water Quality Certification (401) x USCOE / Section 10 x Stormwater Management Plan x CAMA x NCDOT Encroachment Agreement x Railroad Encroachment Agreement x Other: NPDES Permit Modification 8/14/23 12/11/23 NCO043532 APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC 10-23) Page 4 State of North Carolina DWR Department of Environmental Quality Division of Water Resources Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT FORM ATC 10-23 J. Residuals Management Plan ® For all new facilities, expanding facilities, or modifications that result in a change to sludge production and/or sludge processes, provide a Residuals Management Plan meeting the requirements of 15A NCAC 02T .0504(i) and .0508; the Plan must include: ® A detailed explanation as to how the generated residuals (including trash, sediment and grit) will be collected, handled, processed, stored, treated, and disposed. ® An evaluation of the treatment facility's residuals storage requirements based upon the maximum anticipated residuals production rate and ability to remove residuals. ® A permit for residuals utilization or a written commitment to the Applicant from a Permittee of a Department approved residuals disposal/utilization program that has adequate permitted capacity to accept the residuals or has submitted a residuals/utilization program application. ® If oil, grease, grit or screenings removal and collection is a designated unit process, a detailed explanation as to how the oil/grease will be collected, handled, processed, stored and disposed. ❑ Not Applicable. SECTION 4: PROJECT INFORMATION A. WASTEWATER TREATMENT PLANT FLOW INFORMATION — COMPLETE FOR NEW OR EXPANDING FACILITIES 1. Provide the following flow information: Plant Flows Existing Plant Design 1.200 MGD Current NPDES Permit Limit 1.200 MGD Current Annual Average (past 12 months) 0.620 MGD For Past 12 Months: Start Date: 01/23 End Date: 12/23 For Past 24 Months: Start Date: 01/22 End Date: 12/23 Maximum Month 0.831 MGD 0.831 MGD Maximum Day 2.708 MGD 2.708 MGD Peak Hour 4.320 MGD 4.320 MGD APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC 10-23) Page 5 DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT FORM ATC 10-23 B. WASTEWATER TREATMENT FACILITY DESIGN INFORMATION — COMPLETE FOR NEW OR EXPANDING FACILITIES AND FOR TREATMENT PROCESS MODIFICATIONS 1. Have all of the requirements of 15 NCAC 02H. 0100, 15A NCAC 02T, North Carolina General Statute 133-3, North Carolina General Statute 143-215.11 and Division of Water Resources Minimum Design Criteria for NPDES Wastewater Treatment Facilities been met by the proposed design and specifications? ® Yes or ❑ No. If no, provide justification as to why the requirements are not met, consistent with 15A NCAC 02T .0105(n): 2. Provide the design influent and effluent characteristics that are used as the basis for the project design, and the NPDES permit limits for the following parameters: Project Basis of Design Influent Design Influent Design Influent Concentration Concentration Load - Current (Must be (Must be Annual supported by supported by Design Effluent Average (past Engineering Engineering Concentration and/or NPDES Permit Limits 12 months) if Calculations Calculations Load (monthly average) Parameter Available Section 3.11 Section 3.11 Ammonia Nitrogen 1.0 mg/L Summer 1.8 mg/L Summer (NH3-N) N/A mg/L 26 mg/L 550 lb/day 1.0 mg/L Winter 1.8 mg/L Winter Biochemical 5.0 mg/L Summer 5.0 mg/L Summer Oxygen Demand 197 mg/L 230 mg/L 4,800 lb/day (BOD5) 5.0 mg/L Winter 5.0 mg/L Winter Fecal Coliform N/A per 100 mL 200 per 100 mL Nitrate + Nitrite Nitrogen (NO3-N + N/A mg/L N/A mg/L NO2-N Total Kjeldahl N/A mg/L Nitrogen N/A mg/L N/A mg/L Total Nitrogen N/A lb/year N/A lb/year N/A mg/L N/A mg/L Total Phosphorus N/A mg/L N/A mg/L N/A lb/day N/A lb/year N/A lb/year Total Suspended Solids (TSS) 198 mg/L 230 mg/L 4,8001b/day 5.0 mg/L 30.0 mg/L 3. Based on the "Project Basis of Design" parameters listed above, will the proposed design allow the treatment facility to meet the NPDES Permit Limits listed above? ® Yes or ❑ No. If no, describe how and why the Permit Limits will not be met APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC 10-23) Page 6 State of North Carolina DWR Department of Environmental Quality Division of Water Resources Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT FORM ATC 10-23 4. Per 15A NCAC 02T .0505(i), by-pass and overflow lines are prohibited. Is this condition met by the design? ® Yes or ❑ No If no, describe the treatment units bypassed, why this is necessary, and where the bypass discharges: 5. Per 15A NCAC 02T .0505(k), multiple pumps shall be provided wherever pumps are used. Is this condition met by the design? ® Yes or ❑ No. If no, provide an explanation: 6. Per 15A NCAC 02T .0505(1), power reliability shall be provided consisting of automatically activated standby power supply onsite capable of powering all essential treatment units under design conditions, or dual power supply shall be provided per 15A NCAC 02H. 0124(2)(a). Is this condition met by the design? ® Yes or ❑ No. If no, provide (as an attachment to this Application) written approval from the Director that the facility: ➢ Has a private water supply that automatically shuts off during power failures and does not contain elevated water storage tanks, and ➢ Has sufficient storage capacity that no potential for overflow exists, and ➢ Can tolerate septic wastewater due to prolonged detention. 7. Per 15A NCAC 02T .0505(o), a minimum of 30 days of residual storage shall be provided. Is this condition met by the design? ® Yes or ❑ No. If no, explain the alternative design criteria proposed for this project in accordance 15A NCAC 02T .105(n): 8. Per 15A NCAC 02T .0505(a), the public shall be prohibited from access to the wastewater treatment facilities. Explain how the design complies with this requirement: Fencingis s in place around the existing plant. New fencing will be installed around the expanded plant. 9. Is the treatment facility located within the 100-year flood plain? ❑ Yes or ® No. If yes, describe how the facility is protected from the 100-year flood: C. WASTEWATER TREATMENT UNIT AND MECHANICAL EQUIPMENT INFORMATION — COMPLETE FOR NEW OR EXPANDING FACILITIES AND FOR MODIFIED TREATMENT UNITS PRELIMINARY AND PRIMARY TREATMENT (i.e.. Dhvsical removal operations and flow eaualization): No. of Plan Sheet Specification Calculations Treatment Unit Units Type Size per Unit Reference Reference Provided. (Yes or No Manual Bar Screen MGD at peak hourly flow Mechanical Bar MGD at peak hourly flow Screen Grit Removal MGD at peak hourly flow Flow Equalization 2 1,500,000 gallons M-250 to 4651 13 Yes M-254 Primary Clarifier Circular ft diameter; ft side water depth Primary Clarifier Rectangular square feet; ft side water depth Other APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC 10-23) Page 7 State of North Carolina DWR Department of Environmental Quality Division of Water Resources Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT FORM ATC 10-23 2. SECONDARY TREATMENT (BIOLOGICAL REACTORS AND CLARIFIERS) (i.e., biological and chemical processes to remove or anics and nutrients No. of Plan Sheet Specification Calculations Treatment Unit Units Type Size per Unit Reference Reference Provided. (Yes or No Other: Selector 1 Rectangular box 25,000 gallons M-220 46 41 23 Yes Tank Aerobic Zones/ 2 Aeration Tanks (swing 1300 ,,000 gallons M-300 to — Yes Tanks tank + aeration M-305 Secondary 1 Circular 463,000 gallons M-401 to 46 43 21 Yes Clarifier M-403 TERTIARY TREATMENT Plan Sheet Specification Calculations Treatment Unit FNof Type Size per Unit Provided. ts Reference Reference (Yes or No) Tertiary Filter 2 Package unit with 810 square feet M-500 to 46 61 43 No Rotary Disc Filters M-501 4. DISINFECTION Calculations No. of Plan Sheet Specification Treatment Unit Type Size per Unit Provided. Units Reference Reference Yes or No 23,632 of additional gallons of M-600 to Chlorination 1 Chlorine Gas — Yes contact tank/unit M-601 5. RESIDUALS TREATMENT No. of Plan Sheet Specification Calculations Treatment Unit Units Type Size per Unit Reference Reference Provided. (Yes or No) Aerobic Digesters 2 & 3 (Converted Aeration 2 Trapezoidal 600,000 gallons M-800 to 4651 13 Yes M-804 Basins Aerobic Digester 4 1 Circular 206,000 gallons M-820 to 4651 13 Yes Converted 50-ft Clarifier)M-821 6. PUMP SYSTEMS (include influent, intermediate, effluent, major recycles, waste sludge, thickened waste sludge and plant drain DumDS) Capacity Location No. of Purpose Type of each Plan Sheet Specification Pumps um Reference Reference GPM TDH Headworks 1 Pump grease from 3-HP Seepex 25 gpm65.8 ft M-200 to M- 46 21 33 m headworks to duster ro ressive-cavi 201 Equalization (EQ) 2 Divert flow into the Submersible 2,500 43 ft M-253 to M- 3332 11 Pump Station aboveground EQ tanks constant speed gpm 254 APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FOMR ATC 10-23) Page 8 State of North Carolina DWR Department of Environmental Quality Division of Water Resources Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT FORM ATC 10-23 Capacity Location No. of Purpose Type of each Plan Sheet Specification Pumps um Reference Reference GPM TDH New RAS Pump 3 RAS pumps for the new Suction lift, variable 1,085 34 ft M-404 46 07 83 Station 75-ft secondary clarifier seed 9pm New RAS Pump I WAS pump for the new Suction lift, variable 625 21 ft M-404 46 07 83 Station 75-ft secondary clarifier seed 9pm Pumping backwash from 197 112 M-500 to M- Disc Filters 2 the filters to the plant Backwash pump 501 46 61 43 headworks gpm psi New Effluent I Pump WWTP effluent to Vertical Turbine, variaVFDpeed 1,500 267 ft M-700 to M- 43 24 10 Pump Station the Rocky River gpm 701 New Effluent Non -Potable Water Pump, Vertical Turbine, 100 M-700 to M- Pump Station 1 supplies water to the plant variable speed gpm 482 ft 701 43 24 10 reuse waters stem Transfer sludge from the Submersible, Sludge Transfer 2 existing digester to the variable speed 625 73 ft M-810 to M- 3332 12 Pump Station converted digesters / (VFD) gpm 811 sludge h Iding basins Aerobic Digester: Sludge loadout, pumps Submersible 500 M-802 to M- Converted 2 digested sludge to sludge constant speed gpm 37 ft 803 3332 12 Aeration Basins loadingstand Return clarifier scum, New Drain Pump 2 digester decant, and Submersible 1,000 90 ft C-300 3332 11 Station building/structure drains gpm to the new selector tank Feed caustic to aeration Caustic Feed basin influent splitter box M-350 to M- System 2 and to effluent pump Metering pumps 60 gph 134 ft 351 4633 10 station wet well PH/alkalinity control Polymer Feed Feed polymer to the M and System 1 aeration tank effluent Metering pump 2.2 gph 150 ft - 46 33 33 (settlingaid)M353 APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FOMR ATC 10-23) Page 9 State of North Carolina DWR Department of Environmental Quality Division of Water Resources Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT FORM ATC 10-23 7. MIXERS No. of Power of Plan Sheet Specification Location purpose Type each Mixer i Reference Reference Mix together the influent Selector Tank 1 and RAS flow before Submersible 3 M-220 46 41 23 they entering the Areation Tanks If swing tank is not being Swing Tanks 2 aerated, the mixers will Submersible 15 M-301 46 41 23 (Aeration Tanks) mix the contents of the tank anoxic conditions Aerobic Digester 1 Mix and aerate the Floating (Existing Digester) 2 contents the aerobic Aerator 20 M-821 46 51 13 digester g Aerobic Digester 1 1 Mix the contents of the Floating Mixer 5 M-821 46 51 15 (ExistingDigester) aerobic digester Aerobic Digesters 2 Mix the contents of the M-801 to M- & 3 (Converted 2 converted aerobic Floating Mixer 10 802 4651 15 Aeration Basins) digesters Aerobic Digester 4 Mix and aerate the Floating M-820 to M- (Converted 50-ft 1 contents of the converted Aerator 40 821 4651 13 Clarifier) aerobic digester APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FOMR ATC 10-23) Page 10 DWR Division of Water Resources 8. BLOWERS State of North Carolina Department of Environmental Quality Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT FORM ATC 10-23 No. of Capacity of Plan Sheet Specification Location Blowers Purpose Type each Blower Reference Reference Rotary Screw, Aeration Tanks 3 Aerate the aeration Positive 2,400 M-300 to M- 43 1133 tanks Displacement 303 Blowers with VFDs 9. ODOR CONTROL Location No. of Units Purpose Type Plan Sheet Reference Specification Reference N/A N/A N/A N/A N/A N/A D. SETBACKS — COMPLETE FOR NEW WASTEWATER TREATMENT STRUCTURES 1. The minimum distance for each setback parameter to the wastewater treatment/storage units per 15A NCAC 02T .0506(b) are as follows: Minimum Distance Is Minimum Distance Required from Nearest Requirement met by the Setback Parameter Treatment/Storage Design. If "No", identify Unit Setback Waivers in Item D.2 Below Any habitable residence or place of assembly under separate 100 ft ® Yes ❑ No ownership or not to be maintained as part of the project site Any private or public water supply source 100 ft ® Yes ❑ No Surface waters (streams — intermittent and perennial, perennial 50 ft ® Yes ❑ No waterbodies, and wetlands Any well with exception of monitoring wells 100 ft ® Yes ❑ No Any property line 50 ft ® Yes ❑ No 2. Have any setback waivers been obtained per 15A NCAC 02T .0506(d)? ❑ Yes or ® No. If yes, have these waivers been written, notarized and signed by all parties involved and recorded with the County Register of Deeds? ❑ Yes or ❑ No. If no, provide an explanation: APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC 10-23) Page 10 State of North Carolina DWR 1� Department of Environmental Quality Division of Water Resources Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT FORM ATC 10-23 SECTION 5: APPLICATION CERTIFICATION BY PROFESSIONAL ENGINEER Professional Engineer's Certification per 15A NCAC 02T .0105: I, Carl W. Scharfe, attest that this application package for an Authorization to Construct (Typed Name of Professional Engineer) for the Wastewater Treatment Plant Phase II Expansion (Facility and Project Name) was prepared under my direct supervisory control and to the best of my knowledge is accurate, complete and consistent with the information supplied in the engineering plans, specifications, calculations, and all other supporting documentation for this project. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with all applicable regulations and statutes, 15 NCAC 02H. 0100, 15A NCAC 02T, North Carolina General Statute 133-3, North Carolina General Statute 143-215.1, and Division of Water Resources Minimum Design Criteria for NPDES Wastewater Treatment Facilities, and this Authorization to Construct Permit Application, except as provided for and explained in Section 4.13.1 of this Application. I understand that the Division of Water Resources' issuance of the Authorization to Construct Permit may be based solely upon this Certification and that the Division may waive the technical review of the plans, specifications, calculations and other supporting documentation provided in this application package. I further understand that the application package may be subject to a future audit by the Division. Although certain portions of this submittal package may have been prepared, signed and sealed by other professionals licensed in North Carolina, inclusion of these materials under my signature and seal signifies that I have reviewed the materials and have determined that the materials are consistent with the project design. I understand that in accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal with written signature placed over or adjacent to the seal and dated: \���t11111I/� CARO�`�� ?:o SEA 040 5 +� II SC`� �, ``�\t�C���lf���i 'FEss�o � S Z'; 9 9l :a SEAL r- . 0. 052 r �6,C APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC 10-23) Page 1 I State of North Carolina DWR Department of Environmental Quality Division of Water Resources Division of Water Resources APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT FORM ATC 10-23 SECTION 6: APPLICATION CERTIFICATION BY APPLICANT Applicant's Certification per 15A NCAC 02T .0106(b): I, Duane Wingo, Utilities Director, attest that this application package for an Authorization to Construct (Typed Name of Signature Authority and Title) for the Wastewater Treatment Plant Phase II Expansion (Facility and Project Name) has been reviewed by me and is accurate and complete to the best of my knowledge. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. I further certify that in accordance with 15A NCAC 02T .0120(b), the Applicant or any affiliate has not been convicted of environmental crimes, has not abandoned a wastewater facility without proper closure, does not have an outstanding civil penalty where all appeals have been abandoned or exhausted, are compliant with any active compliance schedule, and does not have any overdue annual fees. I understand that the Division of Water Resources' issuance of the Authorization to Construct Permit may be based solely upon acceptance of the Licensed Professional Engineer's Certification contained in Section 5, and that the Division may waive the technical review of the plans, specifications, calculations and other supporting documentation provided in this application package. I further understand that the application package may be subject to a future audit. I understand that in accordance with General Statutes 143-215.6A and 143-215.613 any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. / Signature: l/ll�� . /V / �� Date: 0 Z T 0,,2 L% THE COMPLETED APPLICATION AND SUPPORTING INFORMATION SHALL BE SUBMITTED TO: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER RESOURCES/NPDES By U.S. Postal Service By Courier/Special Delivery: 1617 MAIL SERVICE CENTER 512 N. SALISBURY STREET, 9TH FLOOR RALEIGH, NORTH CAROLINA 27699-1617 RALEIGH, NORTH CAROLINA 27604 TELEPHONE NUMBER: (919) 807-6396 APPLICATION FOR AUTHORIZATION TO CONSTRUCT PERMIT (FORM ATC 10-23) Page 12