Subject: North Carolina Wastewater/Groundwater Laboratory Certification Branch (NC
WW/GW LCB) Maintenance Inspection
Dear Mr. Taylor:
Enclosed is a report for the inspection performed on December 14, 2024 by Tom Halvosa. Where
Finding(s) are cited in this report, a response is required. Within thirty days, please supply this
office with a written item for item description of how these Finding(s) were corrected. Please
describe the steps taken to prevent recurrence and include an implementation date for each
corrective action. If the Finding(s) cited in the enclosed report are not corrected, enforcement
actions may be recommended. For Certification maintenance, your laboratory must continue to
carry out the requirements set forth in 15A NCAC 02H .0800.
A copy of the laboratory’s Certified Parameter List at the time of the audit is attached. This list will
not reflect any changes made during the audit. Copies of the checklists completed during the
inspection may be requested from this office. Thank you for your cooperation during the
inspection. If you have questions or need additional information, please contact me at (984) 220-
5439.
Sincerely,
Beth Swanson
Technical Assistance & Compliance Specialist
Division of Water Resources
Attachment
cc: Todd Crawford, Tom Halvosa, #5572
On-Site Inspection Report
LABORATORY NAME: South Camden Water & Sewer
WATER QUALITY PERMIT #: WQ0029894
ADDRESS: 129 Keeter Barn Rd
South Mills, NC 27976
CERTIFICATE #: 5572
DATE OF INSPECTION: December 14, 2023
TYPE OF INSPECTION: Field Municipal Maintenance
AUDITOR: Tom Halvosa
LOCAL PERSON(S) CONTACTED:
Jovon Taylor, Chuck Jones and Shytazz Barnes
I. INTRODUCTION:
This laboratory was inspected by a representative of the North Carolina Wastewater/Groundwater Laboratory
Certification Branch (NC WW/GW LCB) to verify its compliance with the requirements of 15A NCAC 02H
.0800 for the analysis of compliance monitoring samples.
II. GENERAL COMMENTS:
The facility is neat and well organized and has all the equipment necessary to perform the analyses. Staff
were forthcoming and responded well to suggestions from the auditor.
All required Proficiency Testing (PT) Samples have been analyzed for the 2023 PT Calendar Year and the
graded results were 100% acceptable.
The laboratory did not have Quality Assurance (QA) and/or Standard Operating Procedure (SOP)
document(s) in place for all currently certified parameters. These documents must be submitted for review
as specified in Finding A.
The laboratory is reminded that SOPs are required to be reviewed at least every two years and are
intended to describe procedures exactly as they are to be performed. Use of the word “should” is not
appropriate when describing requirements (e.g., Quality Control (QC) frequency, acceptance criteria, etc.).
Evaluate all SOPs for the proper use of the word “should”.
Contracted analyses are performed by Waypoint Analytical - Greenville (Certification # 10).
The Approved Procedure document for the analysis of the facility’s currently certified Field Parameter was
provided at the time of the inspection.
Page 2
# 5572 South Camden Water & Sewer
III. FINDINGS, REQUIREMENTS, COMMENTS AND RECOMMENDATIONS:
Documentation
A. Finding: The laboratory does not have QA/SOP documents for each certified parameter
method nor a documented plan for PT procedures.
Requirement: Laboratory Procedures. Laboratory procedures shall comply with
Subparagraph (a)(1) of this Rule. A copy of each analytical method or Approved Procedure
and Standard Operating Procedure shall be available to each analyst and available for
review upon request by the State Laboratory. Standard Operating Procedure
documentation shall state the effective date of the document and shall be reviewed every
two years and updated if changes in procedures are made. Each laboratory shall have a
formal process to track and document review dates and any revisions made in all Standard
Operating Procedure documents. Supporting Records shall be maintained as evidence that
these practices are implemented. Ref: 15A NCAC 02H .0805 (g) (4).
Requirement: Laboratories must have a documented plan [this is usually detailed in the
laboratory’s Quality Assurance Manual or may be a separate Standard Operating
Procedure (SOP)] of how they intend to cover the applicable program requirements for
Proficiency Testing per their scope of accreditation. This plan shall cover any commercially
available PT Samples and any inter-laboratory organized studies, as applicable. The plan
must also address the laboratory’s process for submission of PT Sample results and related
Corrective Action Reports (CARs). Ref: Proficiency Testing Requirements, January 1,
2023, Revision 6, Section 3.0.
Comment: An example pH SOP template was provided to the laboratory after the
inspection. The pH SOP must be submitted as part of the inspection report response.
Comment: The laboratory’s PT procedure may be outlined in the parameter method SOP.
The NC WW/GW LCB SOP templates include a section for the PT procedure.
B. Finding: The laboratory benchsheet is lacking required documentation: the method or
Standard Operating Procedure reference and the quality control assessments.
Requirement: All laboratories shall use printable laboratory benchsheets. Certified Data shall
be traceable to the associated sample analyses and shall consist of: The method or Standard
Operating Procedure and the quality control assessments. Each item shall be recorded each
time samples are analyzed. Analyses shall conform to methodologies found in Subparagraph
(a)(1) of this Rule. Ref: 15A NCAC 02H .0805 (g) (2) (A) and (O).
Comment: The benchsheet lacks the method description (SM 4500 H+ B-2011) and the
acceptance criterion of the check buffer (± 0.1 S.U.). The laboratory was provided with an
example pH benchsheet at the time of inspection.
C. Finding: The laboratory is not documenting all traceability information for purchased
materials, reagents and standards.
Requirement: 15A NCAC 02H .0805 (a) (7) (K) and (g) (7) requires laboratories to have a
documented system of traceability for the purchase, preparation, and use of all chemicals,
reagents, standards, and consumables. That system must include documentation of the
following information: Date received, Date Opened (in use), Vendor, Lot Number, and
Expiration Date (where specified). A system (e.g., traceable identifiers) must be in place that
links standard/reagent preparation information to analytical batches in which the solutions are
Page 3
# 5572 South Camden Water & Sewer
used. Documentation of solution preparation must include the analyst’s initials, date of
preparation, the volume or weight of standard(s) used, the solvent and final volume of the
solution. This information as well as the vendor and/or manufacturer, lot number, and
expiration date must be retained for primary standards, chemicals, reagents, and materials
used for a period of five years. Consumable materials such as pH buffers, lots of pre-made
standards and/or media, solids and bacteria filters, etc. are included in this requirement. Ref:
NC WW/GW LCB Traceability Documentation Requirements for Chemicals, Reagents,
Standards and Consumables Policy (03/27/2020).
Comment: The laboratory was provided with an example receipt log for purchased materials,
reagents and standards at the time of the inspection.
Comment: Dates received and opened were written on the pH buffer bottles, as required.
While this can provide a traceability link to analyses while the chemicals are still in use, that
link is lost once the bottles are discarded.
D. Finding: The laboratory is lacking a documented training program.
Requirement: Each laboratory shall develop and implement a documented training program
that includes the following: that staff have the education, training, experience, or demonstrated
skills needed to generate quality control results within method-specified limits and that meet
the requirements of these Rules; that staff have read the laboratory quality assurance manual
or applicable Standard Operating Procedures; that staff have obtained acceptable results on
Proficiency Testing Samples pursuant to Rule .0803(1) of this Section or other demonstrations
of proficiency (e.g., side-by-side comparison with a trained analyst, acceptable results on a
single-blind performance evaluation sample, an initial demonstration of capability study
prescribed by the reference method). Ref: 15A NCAC 02H .0805 (g) (5).
Comment: The laboratory’s training program may be outlined in the parameter SOP. The NC
WW/GW LCB SOP templates include an Employee Training section.
Comment: The laboratory was provided with an example of training documentation after the
inspection.
pH - Standard Methods, 4500 H+ B-2011 (Aqueous)
Recommendation: The laboratory currently records pH compliance sample results to one decimal
place on their benchsheet. It is recommended that the laboratory measure and document sample
results on the benchsheet to two decimal places. The result must continue to be rounded and
reported to 0.1 S.U. on the non-Discharge Monitoring Report (nDMR).
IV. CONCLUSIONS:
Correcting the above-cited Findings and implementing the Recommendation will help this laboratory to
produce quality data and meet Certification requirements. The inspector would like to thank the staff for
their assistance during the inspection and data review process. Please respond to all Findings and
include supporting documentation, implementation dates and steps taken to prevent recurrence
for each corrective action.
Report prepared by: Tom Halvosa Date: January 2, 2024
Report reviewed by: Jill Puff Date: January 4, 2024
Certificate Number:5572
Effective Date:1/1/2023
Expiration Date:12/31/2023
Lab Name:South Camden Water & Sewer
Address:129 Keeter Barn Rd
South Mills, NC 27976
North Carolina Wastewater/Groundwater Laboratory Certification
Certified Parameters Listing
Date of Last Amendment:12/6/2023
The above named laboratory, having duly met the requirements of 15A NCAC 2H.0800, is hereby certified for the measurement of the parameters listed below.
CERTIFIED PARAMETERS
INORGANIC
pH
SM 4500 H+B-2011 (Aqueous)
This certification requires maintance of an acceptable quality assurance program, use of approved methodology, and satisfactory performance on evaluation samples. Laboratories are subject to civil penalties and/or decertification for infractions
as set forth in 15A NCAC 2H.0807.