Loading...
HomeMy WebLinkAboutNC0064246_Wasteload Allocation_19930524NPDES WASTE LOAD ALLOCATION PERMIT NO.: NCO064246 PERMITTEE NAME: Mr. Jerry G. Pace FACILITY NAME: Pace Mobile Home Park Facility Status: Existing Pemut Status: Renewal Major Pipe No.: 001 Design Capacity: Minor `1 0.015 MGD Domestic (% of Flow): Industrial (% of Flow): Comments: 100 % RECEIVING STREAM: an unnamed tributary to Buffaloc Creek Class: C-NSW Sub -Basin: 93- 0:5-04-00 Reference USGS Quad: E 25 NW (please attach) County: Johnston Regional Office: Raleigh Regional Office Previous Exp. Date: 5/31/93 Treatment Plant Class: Classification changes within three miles: No change within three miles Requested by: Charles Lowe Date: 10/27/92 Prepared by: Date: `!,J 4L Reviewed by: ( I fL4,6(4 �UA,9`r'n'1 Daze: �3 3cr, s Modeler I Date Rea # o z Drainage Aiea (mil) o, ty Avg. Streamflow (cfs): n, 71 7Q10 (cfs) D Winter 7Q10 (cfs) 0 Toxicity Limits: IWC % Instream Monitoring: 30Q2 (cfs) a Acute/Chronic Parameters 16,trr�f,4rua- -D.D-,_ a�`i c Ducnviry Upstream y Location AT- tr4= r too' uPSTg4Rw Downstream y LocationA-rL,0asr 3oD`zurAstr4&fv� Effluent Characteristics Summer Winter BOD5 (m ) l NH3-N (mg/1) D.O. (mg/l) 6 6 TSS (1119/1) a F. Col. (/100 ml) �o Zoo pH (SU)— TP Al V I 70je rUoAJi7o12 /conliTOK /✓<o,Vi7oK �•; %•�♦�3 �t60: i ��,• _% 250�'' 300 25 3958 16 ,,A) ,' _,•..'. � Chapel , �•,•.s • t—�._� '� Leee Crossroad Ch ' =: --, 79 —: / �� BM �:. 300 346 349 j i IH IN •t , �� ; _... _,, \ Cem ram. ii 720 it FEE �! _boo : _:, =J!j - -•' a U �' Cc so :i ..=tea.• „q, •` ,,/. - .6 1+ _. � � .._- Wale I' - /�•` �` a• " J' 2� Cem329 tr ' b r` 3391 200 �305 :. J-�r�J +walg• / ^ Arches' 395: BM ' White Oj Ch . ' 1: wallCe ('O f l� �• 333 Willi r Cem i' '33f�J r� • 1 C � " .� • •r•'r l ' 1 .. �' _1 ,g Jp,� / ( 250 �'ljl—/3 ( ,• 395: Facility Name: NPDES No.: Type of Waste: Facility Status: Permit Status: Receiving Stream: Stream Classification: Subbasin: County: Regional Office: Requestor: Date of Request: Topo Quad: FACT SHEET FOR WASTELOAD ALLOCATION Pace Mobile Home Park NCO064246 Domestic - 100% Existing Renewal UT Buffalo Creek C-NSW 030406 Johnston RRO C. Lowe 10/27/92 E25NW Request # ` of n c zt 7174. APR 2 8 1993 J, EH 1 R-RAL RO Stream Characteristic: USGS # Date: Drainage Area (mi2): 0.19 Summer 7Q10 (cfs): 0.0 Winter 7Q10 (cfs): 0.0 Average Flow (cfs): 0.21 30Q2 (cfs): 0.0 IWC (%): 100 Wasteload Allocation Summary (approach taken, correspondence with region, EPA, etc.) This WLA is up for renewal per the Neuse basin plan. An alternatives analysis was submitted 10/92 and TSB recommended that the facility keep its existing limits. The facility has had 3 NH3-N, 1 BOD5, and 7 Fecal coli violations in the past year. No TP limit will be implemented since the facility is < 0.5 MGD. No instream monitoring was required in the previous permit, although it was recommended in WLA. Instream monitoring is recommended with this permit. Special Schedule Requirements and additional comments from Reviewers: Recommended by: of C/(. Date: i1v As Reviewed by InstreamAssessment: Date:),3 �3 Mgional Supervisor: �F Date: Permits & Engineering: Date: RETURN TO TECHNICAL SERVICES BY: MAY n 6 1993 03:01!;" !I t tz V Existing Limits: Wasteflow (MGD): BOD5 (mg/1): NH3N (mg/1): DO (mg/1): TSS (mg/1): Fecal Col. (/100 ml): pH (SU): Residual Chlorine (µg/1): Oil & Grease (mg/1): TP (mg/1): TN (mg/1): Recommended Limits Wasteflow (MGD): BOD5 (mg/1): NH3N (mg/1): DO (mg/1): TSS (mg/1): Fecal Col. (/100 ml): pH (SU): Residual Chlorine (µg/1): Oil & Grease (mg/1): TP (mg/1): TN (mg/1): 2 CONVENTIONAL PARAMETERS Monthly Average Summer Winter 0.015 0.015 9 9 4 4 6 6 30 30 200 200 6-9 6-9 monitor monitor monitor monitor Monthly Average Summer Winter 0.015 0.015 9 9 4 4 6 6 30 30 200 200 6-9 6-9 monitor monitor monitor monitor Limits Changes Due To: Change in 7Q10 data Change in stream classification Relocation of discharge Change in wasteflow Other (onsite toxicity study, interaction, etc.) Instream data New regulations/standards/procedures New facility information gtrly gtrly WQ or EL gtrly qtrly Parameter(s) Affected X_ Parameter(s) are water quality limited. For some parameters, the available load capacity of the immediate receiving water will be consumed. This may affect future water quality based effluent limitations for additional dischargers within this portion of the watershed. •9 No parameters are water quality limited, but this discharge may affect future allocations. l v - 3 INSTREAM MONITORING REQUIREMENTS Upstream Location: at least 100 ft upstream Downstream Location: at least 300 ft downstream Parameters: temperature, D.O., Fecal coli, conductivity Special instream monitoring locations or monitoring fiequencies: MISCELLANEOUS INFORMATION & SPECIAL CONDITIONS Adequacy of Existing Treatment Has the facility demonstrated the ability to meet the proposed new limits with existing treatment facilities? Yes No If no, which parameters cannot be met? Would a "phasing in" of the new limits be appropriate? Yes No If yes, please provide a schedule (and basis for that schedule) with the regional office recommendations: If no, why not? Special Instructions or Conditions Wasteload sent to EPA? (Major) _N (Y or N) (If yes, then attach schematic, toxics spreadsheet, copy of model, or, if not modeled, then old assumptions that were made, and description of how it fits into basinwide plan) Additional Information attached? _N (Y or N) If yes, explain with attachments. _ pJeda6?6 SAW UT &,Ettoc— C- NSW ✓ I R 1 T nn� �/� l ID W'rFT[WC 6V�. T�5 ., 2QLT�ar/�nJrS f�NR4Y5/S y/F5 ,$&li /N 41,Jr 75� PxCo�ir �N D 3 N_�.N)I 80pc V, �T(oNS /A/ r+F )995 lP 4 DIVISION OF ENVIRONMENTAL MANAGEMENT October 19, 1992 TO: Charles Lowe FROM: Jacquelyn M. Nowell THRU: Trevor Clement,— Carla Sanderson xJ SUBJECT: Review of Engineering Alternative Evaluation Report for Pace Mobile Home Park NPDES Permit No. NC0064246 p3o40fe Johnston County 0 The Technical Support Branch has reviewed the subject document and has the following recommendation. The submitted report evaluated several nondischarge alternatives for Pace Mobile Home Park, including connection to the Wendell and Clayton wastewater treatment facilities, a subsurface disposal system, a spray irrigation system, and relocation of the discharge to a positive flow stream. While relocation does seem like a feasible option, the facility would have to pump their effluent almost 3.5 miles. Exercising this option may place eco- nomic hardship on a facility of this size. The facility appears to be operating very well and meeting existing limits with regularity. Pace will have to do some work to come into compliance with the fecal coliform limit of 200/100 ml and also reduce the chlorine levels for instream toxicity. After review of all nondischarge options, Technical Support recommends that Pace Mobile Home Park retain their existing limits of 9 mg/1 BODS, 4 mg/1 NH3-N, and 6 mg/l DO. If there are any questions concerning this recommendation, please contact me. cc: Tim Donnelly Central Files WLA Files