Loading...
HomeMy WebLinkAboutNC0064378_Authorization to Construct_19980615State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary A. Preston Howard, Jr., P.E., Director June 15, 1998 Mr. Carl Daniel, Vice President Carolina Water Service, Inc. of North Carolina P.O. Drawer 240908 Charlotte, North Carolina 28224 Dear Mr. Daniel: ATT•�' NCDENR Subject: NPDES Permit Certification Permit No. NCO064378 Project No. ACB064378 Willowbrook Subdivision Wake County On October 16, 1996, the Division of Water Quality issued an authorization to construct for NPDES Permit No. NCO064378 to Carolina Water Service. A requirement of the permit is that upon completion of construction and prior to operation of this permitted facility a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, the Authorization to Construct and the approved plans and specifications. This certification was received by the Division April 6, 1998. The original is hereby being returned to you for your records. Please maintain it along with the copy of the approved plans and specifications for the life of the facility. If you have any questions concerning this permit, please contact me at telephone number (919) 733-5083, extension 518. Sincerely, ary L. Cabe NPDES Unit Attachment cc: Central Files NPDES Unit Raleigh Regional Office / Water Quality Section Technical Assistance and Certification Unit P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-0719 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper ENGINEER'S CERTIFICATION OF COMPLETION (FOR CONSTRUCTION OF TREATMENT FACILITY UPGRADES) I. RICHARD W. DIMASSIMO , as a duly registered Professional Engineer in the State of North Carolina, as having observed the construction of the project, WILLOWBROOK SUBDIVISION WWTP, CLAYTON. NC, NPDES Permit No. NCO064378 hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the facility upgrades were observed to be built within substantial compliance and intent of the approved plans and specifications. Signature Registration No.21973 Date The Division of Water Quality hereby arkno-wledges receipr ind acceptance of this Engineors -i fication 17161,04e TRIANGLE PO. Box 41087 Raleigh, NC 27629 ENVIRONMENTAL 919-828-3150 800-849-5115 INC. Fox 919-828-1977 April 2, 1998 Ms. Mary Cabe NCDWQ Permits and Engineering Unit Post Office Box 29535 Raleigh, North Carolina 27626-0535 ozgz�?4 CR_ OR p01'vT SOURCE BRANCH Subject: Willowbrook Subdivision WWTP, NCO064378 Clayton, North Carolina Dear Ms. Cabe: Please find enclosed the Engineer's Certification of Completion for the above -referenced facility. If you have any questions, please call Rich DiMassimo or Stan Taylor at 828- 3150. Respectfully, TRIANGLE ENVIRONMENTAL, INC. r Richard W. DiMassimo, P.E. Proj ect Engineer /ra Enclosure xc: Mr. Mike Marvel Mr. Joel Clarke, Carolina Water Service State of North Carolina Department of Environment, , Health and Natural Resources 0 Division of Water Quality James B. Hunt, Jr., Governor Ilk ��► Jonathan B. Howes, Secretary ID FEE N R A. Preston Howard, Jr., P.E., Director Mr. Carl Daniels, Vice President October 16, 1996 Carolina Water Service, Inc. of North Carolina Post Office Box 240705 Charlotte, North Carolina 28224 Subject: Permit No. NCO064378 Authorization to Construct Willowbrook W WTF Improvements Wake County Dear Mr. Daniels: A letter of request for an Authorization to Construct (ATC) was received June 21, 1996 by the Division and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction and installation of the proposed modifications to the existing wastewater treatment system and all necessary appurtenances with discharge of treated water from outfall 001 into an unnamed tributary to the Beddingfield Creek in the Neuse River Basin. Specifically, this ATC allows: • the construction of a dual hopper 162 square foot rectangular clarifier with air-lift type sludge recycle. • the construction of a 1,399 gallon chlorine contact tank. • the relocation of the existing tablet chlorinator. • the construction of a 875 gallon post aeration tank with tablet dechlorinator and fine bubble diffusers. • the installation of fine bubble diffusers to replace existing coarse bubble diffusers in the aeration basin. • the abandonment of the existing chlorine contact tank and post aeration tank. • the installation of additional piping, valves, and control equipment. This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No. NCO064378 issued September 1, 1993 and shall be subject to revocation unless the water treatment facilities are constructed in accordance with the conditions and limitations specified above, and in Permit No. NC0064378. Any sludge generated from this treatment facility must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the North Carolina Division of Environmental Management. In the event that the facility fails to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement water treatment or disposal facilities. The Raleigh Regional Office, telephone number 919/571-4700, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an in -place inspection can be made. Such notification to the regional supervisor Jhall tip made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-0719 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper NCO {}64;78 . 0 o eration of this permitted facility, a certi alled�n Upon completion of construction engineer prior ifying that the permitted facility aasrovedeen 'plans and must be received from a professional eng S Permit, this Authorization to Construct and Box 29535, Raleigh, NC accordance with the NPDE Engineering Unit, Lions. Mail the Certification to the Permits and Eng g specifications. proved plans and specifications shall be maintained on file by the Permittee for the A copy of the ap life of the facility. contained in this Authorization to Construct may Carolina ect the Failure to abide by the requirements coition d Water Quality in accordance with No Permittee to an enforcement action by the D General Statute 143-215.6A to 143 2 the Permittee from complying The issuance of this Authorization to Construct does not prealube imposed by other government with any and all statutes, rules, regulations, or ordinances whichmay agencies (local, state, and federal) which have jurisdiction. u. If you have any g forwarded to yo 1 set of approved plans and specifications is being One t Steven D. Pellei, telephone number 919/733-5083 O {) lease contact questions or need additional information, p extension 516. Sincerely, Jolee"A. Preston Howard, Jr., cc: Central Files Raleigh Regional Office, Water Quality Mr. Richard DiMassimo Triangle Environmental, Inc. P.O. Box CO27629 87 Raleigh, Training and Certification Unit NPDES Files AUTHORIZATION TO CONSTRUCT NPDES PERMIT REPORT AND RECOM MMATIONS Octobert 3, 1996 Project No.: ACA064378 SOC PRIORITY PROJECT: No To: Steve Pellei, Water Quality Permits and Engineering From: Randy Jones, Raleigh Regional Office County: Make Permit No: NCO064378 PART I - GENERAL INFORMATION RECEIVED 1. Facility Name and Current Address: OCT 141996 Carolina Water Service, Inc. of N. C. VM!E4 QUALITY FILES Post Office Box 240705 Charlotte, N. C. 28224 Willowbrook Subdivision WWTF 2. Date of most recent NPDES Staff Report (attach copy): 2/2/93, copy attached 3. Changes since previous action on NPDES Permit: Not aware of any changes. 4. Verify Discharge Point(s) on plans with current NPDES Permit. List for all discharge points: The discharge point is not identified on the plans. The latitudes and longitudes expressed below are as identified on the 2/2/931 NPDES staff report. Latitude: 35* 41' 08" Longitude: 78° 30' 01" Attach a USGS map extract and indicate treatment facility site and discharge point on map: A copy of the previously submitted map is attached to the 2/2/931 staff report. 1 U.S.G.S. Quad No.: E24NE U.S.G.S. Quad Name: Garner 5. Treatment plant classification (attach completed ratings sheet): Class II; Rating Sheet attached PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. Existing treatment facility a. What is the current permitted capacity of the facility? 0.03 and 0.06 MGD b. Date(s) and construction activities allowed by previous Authorizations to Construct issued in the previous two (2) years: None. C. What is the actual treatment capacity of the current facility (design volume)? 0.03 MGD d. Please provide a description of existing or substantially constructed wastewater treatment facilities: The existing 30,000 GPD treatment facilities consist of aeration, a 10 clarifier within the existing aeration basin, a sludge digester (accordingto plans), chlorinator and contact tans )� a tablet post aeration tank, and cascade aerator to discharge. 2. Please provide a description of proposed wastewater treatment facilities: The proposed modification is to construct a new dual hopper 162 square foot rectangular clarifier, a new tablet chlorinator and 1399 gallon contact tank, a new 875 gallon post aeration tank with tablet dechlorinator, and new fine bubble diffusers to replace the existing coarse bubble diffusers. 3. Residuals handling and utilization/disposal scheme: Sludge digester with land application of residuals. a. If residuals are being land applied, please specify DEM permit no.: WQ0000506 Residual Contractor: Wallace Woodall b. Residuals stabilization: PSRP RECEIVED OCT 1 41996 2 WATER QUALITY FILES 1 C. Landfill: N/A 4. d. Other disposal/utilization scheme (Specify): N/A Important SOC, JOC or Compliance Schedule dates: N/A III. EVALUATION AND RECOMMENDATIONS The RRO has reviewed the plans/specifications and engineering report that has been submitted to the Division for the modification of the Willowbrook Subdivision WWTF. • The proposal is to construct a new rectangular clairifer, chlorinator and contact tank, post aeration tank with tablet dechlorinator, and to replace all of the coarse bubble diffused air piping with fine bubble diffused air piping. These modifications should help the facility to meet the limits currently specified in the permit. P&E may wish to include some language in the A to C regarding the draft Neuse Plan and possible future requirements. The RRO did not receive a copy of the letter from the permit holder requesting the A to C, but assumes that one was submitted. Upon satisfactory resolution of any concerns of Water Quality Permits and Engineering, the RRO has no objections to the issuance of the requested A to C. 110 Signature Preparer Wat &44 ity Regiona file: ACA64378.SR Supervisor 3 Date 61130 c Date 4Cj 1 Q t996 VgTER QUALITY FILES 05/05/96 21:21 CAROLINA WATER 4 919 733 0719 NO.674 1701 CAROLINA WATER RERVICE, INOn of NORTH CAROLINA UMMMOF Ulf DUI n[ MEIFMCC S701 Woalpark D� s708 P.G. ix OWatte, NO 28224 Teleftm. (704) 585-7890 FAX: (704) 525.8174 Mr. Steven Pallei N.C. Dept. of ERN.R. Division of Environmental Management - WQ P.O. Box 29535 Raleigh NC 27626 Ermner Elk, NO Chertette, NO Morehead City, NO Whiwdne PifflLsl No Re: Willowbrook WVV'TP modification plans - permit #ACA064378 NPDES NCO064378 Dear Mr. Pellei, 5/6/96 Thank you for your time during our phone conversation this morning. Tho abova referenced plans, currently in your office for review, were submitted prematurely and we would like the plans returned to the design engineer, Mr. Ray S. Taylor of Triangle Environmental Inc. at your earliest Convenience. I will FAX a copy of this letter to Mr. Taylor who will come to your office to personally pick up the application package so that you will not have to go through the trouble of mailing the material. We will review the plans and make some changes, at which time we will resubmit with the. proper application signed by us for your department's review and approval. Thank you for your time and attention and cooperation in this matter. incorcly, M actin ashua Regional Manager cc: Carl Daniel Joel Clarke Ray S. Taylor - Triangle Environmental Inc. 7041898-5011 704S26.7M 910/040-9010 "100% Re.Ayc'ed Papar