Loading...
HomeMy WebLinkAboutSW5221001_Supplement-EZ Form_20240326 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Umstead State Park Campground Improvements 2 Project Area ac 150.4 3 Coastal Wetland Area ac 0 4 Surface Water Area ac 1.8 5 Is this project High or Low Density? Low 6 1 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided feet 50 8 Will the vegetated setback remain vegetated? Yes 9 Ilf BUA is proposed in the setback,does it meet NCAC 02H.1003 4 c-d? N/A 10 1 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration S stem 0 12 Bioretention Cell 0 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Spreader-Filter Strip LS-FS 0 20 Disconnected Impervious Surface(DIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 lBayfilter 0 26 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: John F.Watson 28 Or anization: Finch and Associates 29 Street address: 309 N.Boylan Ave 30 City,State,Zip: Raleigh,NC 27603 31 1 Phone numbers : 919-833-1212 32 Email: jwatson@finch-associates.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision,that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete,and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer C Ar1� SEAL •: /signature of Designer = 039760 Jo Nc i r� ��•o� 17 F VV ati5 t 1% ``��` 3/26/2024 Seal Date DRAINAGE AREAS 1 Is this a high density project? No 2 If so, number of drainage areas/SCMs 0 3 Does this project have low density areas? Yes 4 If so, number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION is Entire Site LD 1 4 Type of SCM none none 5 Total drainage area (sq ft 6,549,600 6,549,600 6 Onsite drainage area (sq ft) 6,549,600 6,549,600 7 Offsite drainage area (sq ft 0 0 8 Total BUA in project (sq ft 188800 sf 188800 sf New BUA on subdivided lots (subject to permitting) 9 (sq ft sf sf New BUA not on subdivided lots (subject to 10 ermittin sf 71700 sf 71700 sf 11 Offsite BUA (sq ft sf sf 12 Breakdown of new BUA not on subdivided lots: 0 0 - Parking (sq ft 37400 sf 37400 sf - Sidewalk (sq ft 4300 sf 4300 sf - R of (sq ft 3000 sf 3000 sf - Roadway s ft 8600 sf 8600 sf - Future (sq ft sf sf - Other, please specify in the comment box below (sq ft 18400 sf 18400 sf New infiltrating permeable pavement on subdivided 13 lots (sq ft sf sf New infiltrating permeable pavement not on 14 subdivided lots (sq ft sf sf Existing BUA that will remain (not subject to 15permitting) s ft 117100 sf 117100 sf 16 Existing BUA that is already permitted (sq ft sf sf 17 Existing BUA that will be removed (sq ft 63600 sf 63600 sf 18 Percent BUA 3% 3% 19 Design storm inches NA NA 20 1 Design volume of SCM cu ft NA NA 21 lCalculation method for design volume NA NA ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): BUA not categorized under item #12 above consists of surface components for septic system and hardscape campsite areas for picnic tables and tent setup. LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1 003(2)(c)? Yes 4 Side slopes of the vegetated conveyances(H:V) 3 sf 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 2.5 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s)(%) NA 8 Bottom width of curb outlet swale(s)(feet) NA 9 Maximum side slope of curb outlet swale(s)(H:V) NA 10 Minimum length of curb outlet swale(s)(feet) NA 11 Are treatment swales used instead of curb outlet swales? No 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 JAre variations to rule.1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: 4.Side slope of Vegetated conveyances:3:1 13.Flow velocities in vegetated conveyances are not sufficient to require rip-rap dissi ators. Drainage Pervious Swale BUA Q Slope Va„o„, Va�„a, Flow depth # Area (ac) area C (cfs) (/) (fps) (fps) (ft) ac ac 1 0.74 0.27 0.47 0.40 2.10 0.70 4.00 1.40 0.73 2 0.94 0.32 0.62 0.40 2.70 3.00 4.00 2.50 0.75 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30