Loading...
HomeMy WebLinkAboutNCC240675_Site Plan or Location Map_20240308 PROPERTY INFORMATION: PARCEL ID NUMBER:6863-37-3119.000 $ O p 6863-36-2771.0000 ZONING:GI-L,GI O tt Z N p�DEMOLITION GENERAL NOTES KEY NOTES ACREAGE:15.07 AC > RI UNION CROSS ROAD j z 1. ALL UTILITIES OR STRUCTURES NOT DESIGNATED FOR REMOVAL OR MODIFICATION ARE TO REMAIN .0 NEW TEMPORARY CONSTRUCTION ENTRANCE/EXIT. PROPERTY OWNER/DEVELOPER: E JO AND BE PROTECTED.ALL UTILITIES OR STRUCTURES DESIGNATED FOR MODIFICATION SHALL BE STORE MASTER FUNDING XXIII.LLC Li' 0 D PROTECTED BY THE CONTRACTOR DURING CONSTRUCTION. OB NEW TEMPORARY SEDIMENT FENCE.REMOVE PAVEMENT INITIALLY ONLY AS 8377 EAST HARTFORD DRIVE,SUITE 100 I C U) Q REQUIRED TO INSTALL SEDIMENT FENCE. SCOTTSDALE,AZ 85255 O — 0 U Eo 2. THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES IS APPROXIMATE.THE CONTRACTOR CONTACT:SAM WINTERS SITE Z D H SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL ILLUSTRATED UNDERGROUND UTILITIES AND I( NEW TEMPORARY SILT FENCE OUTLET. PHONE:(336)785-0848 ' Op9 C 7 K PROPOSED UTILITY CROSSINGS.THE CONTRACTOR SHALL EXERCISE REASONABLE EFFORTS TO EMAIL:swinters0lyndonsteel.com O4- (� K Z M m PROTECT ANY UNKNOWN UNDERGROUND UTILITIES.NOTIFY ENGINEER IMMEDIATELY IF ANY D NEW TEMPORARY ON-SITE CONCRETE WASHOUT STRUCTURE WITH LINER. �ggP ELEMENTS ARE DISCOVERED THAT WOULD NECESSITATE DESIGN REVISIONS. PROVIDE CLEARLY MARKED SIGNAGE NOTING DEVICE LOCATION. ENGINEER: O '9 N E LT, C N ALLIED DESIGN,INC. '� W a.Q^- N 3. CONDUCT DEMOLITION OPERATIONS TO PREVENT INJURY TO PEOPLE AND DAMAGE TO ADJACENT O NEW TEMPORARY WIRE AND STONE DROP INLET FILTER.CONVERT TO SILT CONTACT STEVE CAUSEY Z W N N N BUILDINGS AND FACILITIES TO REMAIN.ENSURE SAFE PASSAGE OF PEOPLE AROUND DEMOLITION SACK ONCE FINISHED GRADE IS ESTABLISHED. 4720 KESTER MILL ROAD -0 CD L Z C2 m AREA.PROTECT EXISTING SITE IMPROVEMENTS,APPURTENANCES AND LANDSCAPING TO REMAIN. PHONE,WINSTON-SALEM,N.C.27103 Z W 0 0 OEXISTING STRUCTURE TO REMAIN.PROVIDE CONCRETE COVER OVER PHONE:(336)765-2377 W Y I- y 4. USE WATER MIST,TEMPORARY ENCLOSURES AND OTHER SUITABLE METHODS TO LIMIT THE SPREAD EXISTING STRUCTURE.VERIFY WITH STRUCTURAL ENGINEER THAT EXISTING EMAIL:scausey@alliedengsurv.com VICINITY MAP : g G Z o OF DUST AND DIRT.COMPLY WITH GOVERNING ENVIRONMENTAL PROTECTION REGULATIONS.DO INLET IS STRUCTURALLY SOUND AND THAT NEW STRUCTURE,FOOTINGS,OR x NOT CREATE HAZARDOUS OR OBJECTIONABLE CONDITIONS,SUCH AS ICE,FLOODING AND COLUMNS WILL NOT BE AFFECTED BY THE STRUCTURE. NOT TO SCALE v S d LL c POLLUTION,WHEN USING WATER.REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE ON ADJACENT SURFACES AND AREAS. I I EXISTING PAVEMENT TO BE REMOVED.SAW CUT EXISTING PAVEMENT TO -"•(`ylyA` PROVIDE STRAIGHT AND UNIFORM LINE FOR REMOVAL. 5. CONTRACTOR SHALL REMOVE AND LEGALLY DISPOSE OF DEMOLISHED ITEMS AND MATERIALS PROMPTLY.ON-SITE STORAGE OR SALE OF REMOVED ITEMS IS PROHIBITED.ON-SITE BURNING OF p 4 EXISTING CONCRETE TO BE REMOVED.SAW CUT EXISTING CONCRETE TO DEMOLISHED MATERIALS WILL NOT BE ALLOWED. 6® -4 PROVIDE STRAIGHT AND UNIFORM LINE FOR REMOVAL. 8. SALVAGEABLE FILL MATERIALS FROM SITE DEMOLITION DETERMINED ACCEPTABLE BY AN I,: 'i EXISTING GRAVEL TO BE REMOVED. FIRM LICENSE C-1891 INDEPENDENT SOILS TESTING LABORATORY MAY BE UTILIZED FOR FILL MATERIAL WHERE APPROPRIATE. -EXISTING PAVEMENT TO REMAIN AND TO BE PROTECTED. i e� T. NO SIGNAGE SHALL BE REMOVED TEMPORARILY OR PERMANENTLY FROM THE NCDOT RIGHT-OF-WAY. ,,°.( 3eN CARO���', SIGNAGE SHALL BE PROTECTED DURING ALL CONSTRUCTION ACTIVITIES.ANY SIGNS DAMAGE DURING CONSTRUCTION SHALL BE REPAIR OR REPLACED AT CONTRACTORS EXPENSE. :.. ..0 ' 9 8. ALL EXISTING TREES NOT DESIGNATED FOR REMOVAL SHALL REMAIN AND BE PROTECTED DURING EXACT LIMITS OF ASPHALT,CONCRETE AND _ EAL 1�—2: ALL CONSTRUCTION ACTIVITIES.CONTRACTOR SHALL PROVIDE TREE PROTECTION FENCING TO GRAVEL DEMOLTION AND REMOVAL LIMITS TO 197OJ.n V': PROTECT EXISTING ROOT SYSTEM AND CANOPY BY SETTING FENCING BACK ONE FOOT RADIUS FOR EACH INCH OF DIAMETER OF TREE. BE DETERMINED IN THE FIELD BASED ON FINAL `'. I" GRADES AND STORM DRAINAGE INSTALLATION. =y`rl�%INEF�`'k,.`� 9. ALL POWER POLES,GUY WIRES AND OVERHEAD LINES NOT DESIGNATED FOR REMOVAL SHALL ''r'•G'M CpuS',. REMAIN AND BE PROTECTED DURING ALL CONSTRUCTION ACTIVITIES. \ �\BUILDING ASPHALT \ BUILDING j //////// \ Z / F_4•MAPLE / WHEEC STOPS // //// JI . O \SIGN o ( GRA✓EL I PARKING o \\LT ,rESL D 7 B I 'MAPLE �� I \ A� O Q IY /4 SPACES1 NAD '�+ J ct C.) 4. / /////// PARK/NO „ ,. (1 \ - i \ W W �_ J �93A, I = / , TREE SAVE I— CI,.., W co K �‘ 1 \ \ AREA-3,098 SF (n H K Z A� \ �� Z I- U ASPHALT v� - \ v 0 0 o z w N iipaiiitim. , . Z ASPHALT PAVEMENT \f ,\ Z 9 \) — -4 111.1111111...k ,A\\ \ CANOPY yam' / ✓ X ) T\`O 0 1 ,\,,, \ l GNA✓EL AREA I 1 RlM 9J23 ✓ / R/M 932.6\\ I \ /NV9154 / 3D'RCP A _ o < `" 3 a Cm l ) �'ii 9 F •• i _ \\�1, /I `S \ DRAINAGE AREA 38990 SF-"I I f �� ���DRABJAGE AREA=1B,2105Ft ,1 Cl OR JUNCTION BOX N \ R/M9320 Z Y V ` ) AREA TREE SA O SF Z Y iw�;` 296 = o /' 1111 1 ._ a o 0 �,1111114►11�11 _ - YEL AREA � i�� •\ � \\ �11 \r 11111111111'=1111111111111 ASP,�LT ♦11 ♦1111111111/111111111111 \ \\ ASPHALT �� G '.. ° I RAI¢E �; 11 ♦11♦ 11 ♦1 ��_ ° m �111111�►1101111�—A► •, 111111j1� • w ; .. ✓ I �� 11:1i1111�11�i1� o,d�EL iQ. '' ,\ \ N a 1 BUILDING / \ \ /� Og `v� 2000 o° o / ACCESSORY I - �I 11 - `BJS<S . y// `'�' b °o°o°°°oo• Q / BUILDING �/ I \ O -o�oo 0000°0 0 0 �o°000•o• w CONCRETE PAD XFMR II 1- W(/EEL 3,TOPS GRAVEZ AREA J . ` - e °° 0000°o ,,, / �" � (TYPICAL) (A SPACES)/ - 'V ASPHALT o oo 00000 $00000 //////////////// 11 1/ / / T/7 U E L 9r7'177/////`TT777///- / GRAVEL \` `...`'�..—o°0.°.-- 00000•3\ N 1 1 I ► ♦' °0000 °o°o°L°000 0000\ Q o II II ro / \ °\ \° o L °o°oo.0 %o4:0.\ \ 0 11 a \ \0000 op° �d Z o II II / I GRA L °oo d°o°o 0 0 0°:°°°. Q °a�o°000°� \ III II / AI I \\ \V i �•bi' OII \\ EXISTING CONDITIONS, 1 I BUILDING / GRA✓EL // 7 I \ I I / \ II I \ STAGE 1 EROSION WS/FC EROSION CONTR ICE I I / \ I 1 // \�SPHALT PLANS APPROVED FOR N UCTION II 11 \\ I I / \ CONTROL AND This plan complies with Ch er ,Se n 4-Erosion Control DEMOLITION PLAN of the Winston-Sale rs ounty fied Development Ordinance. A printe of the p pproved plans must SHEET be kept on the const on si e of ce when installing GRAPHIC SCALE required erosion con m ur ct, ` C 1 . 1 ( IN FEST) matthewo /09/2024 10:22:09 AM 1 inch= SD ft.