Loading...
HomeMy WebLinkAboutWQ0032548_Compliance Evaluation Inspection_20221215ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Mr. Jeff Brink and Ms. Tracy Legeza 8528 Waxhaw Creek Road Waxhaw, North Carolina 28173 Dear Mr. Brink and Ms. Legeza: NORTH CAROLINA Environmental Quality December 15, 2022 by Email Subject: Non -Discharge Permit Follow-up Inspection Wastewater Surface Irrigation System Permit #WQ0032548 Union County Mooresville Regional Office (MRO) staff conducted a follow-up inspection, on December 13t", 2022, to confirm the recirculation tank pump(s), UV system and driplines were repaired as noted in the May 2022, inspection, and Notice of Violation. The MRO would like to thank Ms. Legeza and TCW Wastewater staff for their time during the two October site visits and final December 2022 inspection, confirming additional repairs for the UV System and driplines and return of critical systems to compliance. The current owners are in the process of selling this home. A permit renewal application for ownership change is attached for convenience to pass along to the new owners. They may contact Maria Schutte by email maria.schutteCcDncdenr.gov or phone (704-235-2184) for further assistance. Sincerely, Docu Signed by: � 44W H P44,f 1. F161FB69A2D84A3... Andrew H. Pitner, P.G., Assistant Regional Supervisor Mooresville Regional Office Water Quality Regional Operations Section Division of Water Resources, NCDEQ Attachment(s): WQ0032548 Follow-up Inspection Report — December 2022 Ownership Change and Permit Renewal form(s) CC: Brandon Long, TCW Wastewater (Email) Union County Environmental Health (Email) North Carolina Department of Environmental Quality I Division of Water Resources D E Q Mooresville Regional Office 1 601 East Center Avenue, Suite 301 1 Mooresville, NC 28115 NORTH CAROLINA 704.663.1699 Compliance Inspection Report Permit: WQ0032548 Effective: 07/22/22 Expiration: 01/31/29 Owner : Jeffrey E Brink SOC: Effective: Expiration: Facility: 8528 Waxhaw Creek Rd. SFR County: Union 8528 Waxhaw Creek Rd Region: Mooresville Waxhaw NC 28173 Contact Person: Jeffrey E Brink Title: Phone: Directions to Facility: From exit 61 on 1-485 travel south on Hwy 521 approx. 20 miles, continue past the intersection with SC Hwy 5, turn left onto E N Corner Rd, turn left onto Tirzah Church Rd, turn left onto Waxhaw Creek Road, turn left at unpaved drive #8528 go 0.5 miles. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 12/13/2022 Entry Time 10:40AM Exit Time: 02:15PM Primary Inspector: Maria Schutte Phone: 704-663-1699 Secondary Inspector(s): Reason for Inspection: Follow-up Inspection Type: Compliance Evaluation Permit Inspection Type: Single -Family Residence Wastewater Irrigation Facility Status: Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions Permit Status Septic Tank Sand Filter/Treatment Pods Disinfection UV Pump Tank Drip or Irrigation General (See attachment summary) Page 1 of 5 Permit: WQ0032548 Owner - Facility: Jeffrey E Brink Inspection Date: 12/13/2022 Inspection Type: Compliance Evaluation Reason for Visit: Follow-up Inspection Summary: Mooresville Regional Office (MRO) staff conducted a follow-up inspection, on December 13th, 2022, to confirm the recirculation tank pump(s), UV system and driplines were repaired as noted in the May 2022, inspection, and Notice of Violation. The MRO would like to thank Ms. Legeza and TCW Wastewater staff for their time during the two October site visits and final December 2022 inspection, confirming additional repairs for the UV System and driplines and return of critical systems to compliance. The current owners are in the process of selling this home. A permit renewal application for ownership change is attached for convenience to pass along to the new owners. They may contact Maria Schutte by email maria.schutte@ncdenr.gov or phone (704-235-2184) for further assistance. Page 2 of 5 Permit: WQ0032548 Owner - Facility: Jeffrey E Brink Inspection Date: 12/13/2022 Inspection Type: Compliance Evaluation Reason for Visit: Follow-up Permit Status Yes No NA NE # Is the current resident in the home the Permittee? 0 ❑ ❑ ❑ # If not, does the resident rent from the Permittee? ❑ ❑ 0 ❑ Change of Ownership form needed? (Mail the form with the inspection letter) 0 ❑ ❑ ❑ # Is there an inspection and maintenance agreement with a contractor? ❑ ❑ 0 ❑ If YES, who is the contractor (include contact info)? Historically this system was maintained by Water Management (Sid Gaskins 828-244-9765 or Sid@watermanementnc.net) and TCW Wastewater (Brandon Long 704-351-4049 or Brandon@tcwwastewater.com) was used for recent repairs. Comment: The home is under contract for sale. MRO staff will need to follow-up with the next owners to ensure they received a copy of the Change of Ownership Form sent to present owner with this report. Septic Tank Yes No NA NE *** The septic tank and filters should be checked annually and pumped/cleaned as needed.' Is all wastewater from the home connected to the septic tank? ❑ ❑ ❑ # Does the permittee/resident know where the septic tank is located? ❑ ❑ ❑ Has the septic tank been pumped in the last 5 years? ❑ 0 ❑ ❑ If YES, describe if known and proof (include date pumped): For past several years occupancy by various owners has resulted in only two adults utilizing the system. During this inspection sludge judge showed 13" of sludge volume in 1 st compartment of the septic tank vs. 4' total volume and did not indicate the need for pumping. Some floating scum was also noted. Percentage of sludge to total volume ratio was less throughout the rest of the system. # Does the septic tank have an EFFLUENT FILTER or SANITARY T? ❑ ❑ ❑ If FILTER, when was the filter cleaned and by who? 12/13/2022 by contractor. Comment: Both filters, at septic tank and recirculating pump tank, were pulled and rinsed off into the septic tanks' 1 st compartment. Sand Filter/Treatment Pods Yes No NA NE *** Accessible sand filter surfaces shall be raked/leveled every 6 months and vegetative growth shall be removed manually. *** # Is system something other than a sand filter? 0 ❑ ❑ ❑ # If YES, what kind? (examples - Peat, Textile or brand name - Advantex, etc.) Textile # Does the permittee know where the sandfilter is located? 0 ❑ ❑ ❑ Does the sandfilter require maintenance? ❑ ❑ On If maintenace is required, explain: This system historically appears to have more bio-growth than MRO staff has observed in other Single Family Residence systems. Watch for bridging (build-up) between textile gaps - a couple were removed by the technician during this site visit and may have been related to insect activity. Distribution caps appear to need rinsing approximately every 6 months, with routine maintenance. Comment: As stated above. Page 3 of 5 Permit: WQ0032548 Owner - Facility: Jeffrey E Brink Inspection Date: 12/13/2022 Inspection Type: Compliance Evaluation Reason for Visit: Follow-up Disinfection UV Yes No NA NE *** UV unit shall be checked weekly. Lamps/sleeves should be cleaned/replaced as needed to ensure proper disinfection. *** Is UV working? ❑ ❑ ❑ Has the UV Unit been serviced and bulbs cleaned? 0 ❑ ❑ ❑ # Who completes the weekly check for the UV? ( Non -Discharge) Owner - Discuss with technician or manufacture for safe weekly check of UV. Comment: The entire UV disinfection unit was replaced during this inspection. TCW technician noted at the second October site visit that the UV system was not operable, the replacement unit was received on 12/9/2022 and installed on 12/13/2022. MRO staff recommends the owner(s) discuss with their technician or system manufacturer for safe weeklv check of UV. For eve safetv - do not view bulb. Pump Tank Yes No NA NE *** All pump and alarm sytems shall be inspected monthly. (Non -Discharge) *** Is the pump working? 0 ❑ ❑ ❑ Is the audible and visual high water alarm operational? 0 ❑ ❑ ❑ # Does the permittee know how to check the pump & high water alarm? ❑ 0 ❑ ❑ # Last functional test: October 26, 2022 Comment: Per phone communications with the owner(s) after the May 2022 inspection, a new pump also failed and reduced power was determined to be the reason for pump and high-water alarm issues. MRO staff received follow-up email on August 1 st, 2022, stating an electrician completed power repairs on Friday, July 29th, 2022, but drip -line repairs were still needed. Visual and audible alarms were viewed at the Oct 26th. 2022. site visit and durina the December 13th, 2022, site visit TCW staff tested all electrical communication between the pump tank floats and the control box. Technicians from both contract companies (TCW and Water Management) stated there is a programmed delay for the high-water float to trigger the alarms. Most systems today also have installed telemetry or an auto -dialer system to call/text the owner and/or contractor when a high-water float is triggered. Neither is required but recommended and is at the discretion of the new owner. Drip or Irrigation *** Irrigation sysetm shall be inspected monthly to ensure system is free of leaks and equipment is operating as designed. *** # Type of system (DRIP or IRRIGATION): # If IRRIGATION, number of sprinkler heads: Are buffers and setbacks adequate? Is the site free of ponding and runoff? Does the application equipment appear to be working properly? Is there a minimum two wire fence surrounding the entire irrigation area? Yes No NA NE Drip NA ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page 4 of 5 Permit: WQ0032548 Owner - Facility: Jeffrey E Brink Inspection Date: 12/13/2022 Inspection Type: Compliance Evaluation Reason for Visit: Follow-up Comment: This facility has a reduced setback waiver to a property line for the drip field. TCW staff repaired several line breaks in all zones of the drip field during the October 26 & 27, 2022, site visits. After installation of the UV unit, the remaining dripline repairs were made on December 13th, 2022. At the time of inspection, MRO staff did not observe additional drip line breaks. Routine field maintenance, including mowing, reseeding and appropriate soil replacement for holes / depressions are the responsibility of the permittee and typically are not services provided by wastewater system contractors. General Yes No NA NE # Are the treatment units locked and/or secured? 0 ❑ ❑ ❑ # Has resident had any sewage problems? ❑ ❑ ❑ If YES, explain: No know sewage problems. Current owner called contractor when they thought repairs were needed. Does the system match the permit description? ❑ ❑ ❑ If NO, explain: Is the system compliant? ❑ ❑ ❑ Is the system failing? (If yes, take pictures if possible) ❑ ❑ ❑ If system is failing, describe any exposures to people/animals or environmental risks. The system is aging, and repairs are to be anticipated. Comment: Large, heavy clumps of grass, root balls make it difficult to see all drip lines. Upon completion of sale, new owners are encouraged to contact MRO staff with any questions or concerns. Page 5 of 5