Mr. Michael Barrett
343 Carlton Drive
Chapel Hill,NC 27516
Subject: Compliance Evaluation Inspection
Single Family Wastewater Treatment System
General NPDES Permit NCG550000
Certificate of Coverage NCG550642
Facility: 343 Carlton Drive
Orange County
Dear Mr. Barrett,
On February 28, 2024, Donald Smith and Danny Smith from the Raleigh Regional Office visited
your single-family residence (SFR)wastewater treatment system to evaluate compliance with the
subject General NPDES Permit. The assistance Wynne provided during the inspection was
greatly appreciated.
Our records indicate the treatment system consists of a septic tank sub-surface sand filter, tablet
chlorinator with chlorine contact chamber, and discharge pipe.
General NPDES Permit NCG550000 and Certificate of Coverage (COC)NCG550642 authorize
the discharge of domestic wastewater from your treatment system to receiving waters designated
as Wilson Creek(classified as Water Supply(WS-IV); Nutrient Sensitive Waters (NSW)) in the
Cape Fear River Basin. The authorized discharge is in accordance with the effluent limits and
monitoring requirements established within the General Permit. The items below show what
conditions were noted at your facility:
Findings during the inspection were as follows:
1. Treatment system operation: The wastewater treatment system shall be
maintained at all times to prevent seepage of sewage to the surface of the ground.
Prior to the inspection, you provided pictures and notice of some soil settlement
around the septic tank that was installed by a previous homeowner(Photo 1.).
Please fill in the holes and voids associated with the settlement. Please monitor
your septic tank closely for any irregular settlement or failure of the septic tank.
If tank settlement or other problems occur that affect the proper operation or
failure of your system, you are required to notify the Raleigh Regional Office as
required in NCG550000, Part II (D.)(3)—Anticipated Noncompliance.
North Carolina Department of Environmental Quality I Division of Water Resources
D E Q�� Raleigh Regional Office 13800 Barrett Drive I Raleigh,North Carolina 27609
NORTH cnaoVF 919.791.4200
DepYaanl of EmYaanental Oual�
DocuSign Envelope ID:606567A9-438E-4487-BA15-F58077AE1D34
Mr.Michael Barrett,NCG550642
March 4,2024 Page 2 of 4
2. Pumping the septic tank: You are required to inspect the septic tank at least
yearly to determine if solids must be removed or if other maintenance is
necessary. Septic tanks should be pumped out every five years or when the solids
level is found to be more than 1/3 of the liquid depth in the septic tank
compartment, whichever is greater. A pumping company can check the status
periodically and determine when pumping is required. You provided
documentation showing Septic-R-Us, LLC pumped out the septic tank on
February 2, 2024. The General NPDES Permit requires the permittee to retain
records associated with sewage disposal activities for a period of at least 5 years.
3. Chlorine tablets in the chlorinator: You are reminded that it is required that
chlorine tablets be maintained in the chlorinator to ensure proper disinfection of
the discharged wastewater. Chlorine tablets provide effective disinfection and
prevent/limit harmful bacteria from discharging to the environment. The product
label for these tablets must indicate the tablets are approved for wastewater use
and not for swimming pools. Part 1, Section D (1) of General NPDES Permit
NCG550000 requires the permittee to inspect the tablet chlorinator weekly to
ensure there is an adequate supply of tablets for continuous and proper operation.
Section D (4) requires the permittee to maintain all system components,
including...disinfection units...at all times and in good operating order. The
inspector observed chlorine tablets in the chlorinator. Please continue to ensure
the correct type of tablets are used and maintained in the chlorinator as
required by the General NPDES Permit. With weekly inspections, ensure the
tablets feed to the bottom of the chlorinator tubes. Chlorine tablets can swell
and get stuck in the tube where they do not settle and come in contact with the
wastewater stream.A straight rod can be used to help push the chlorine tablets
down when needed.
4. Analyzing the effluent: Part 1. C.,Effluent Limitations and Monitoring
Requirements,within General Permit NCG550000 requires a permittee to sample
and analyze the effluent leaving his/her treatment system prior to discharge
annually. Parameters to be sampled and analyzed include Flow, BOD
(Biochemical Oxygen Demand), Total Suspended Solids, Fecal Coliform, Total
Residual Chlorine, Total Nitrogen, Ammonia Nitrogen and Total Phosphorous.
Within 30-days of receiving this letter, please let this office know if you have
monitored your effluent discharge within the last 12 months and provide this
office with a copy of the lab results if you have. If you have not monitored your
effluent, then please collect a representative sample of the effluent, have it
analyzed by a certified commercial laboratory and submit the results to this office
no later than April 30, 2024. If, during this time you are unable to collect a
representative sample of the effluent discharge due to insufficient flow from the
discharge pipe, then update this office with that information and continue to
monitor the discharge. If conditions for sampling become favorable, then arrange
to collect a sample. Failure to monitor the effluent discharge as required is a
violation of NPDES General Permit NCG550000.
D E Q�� North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive I Raleigh,North Carolina 27609
NORTH CAROUNA _
Depwbnwd„F r��,�wla�,\ /./ 919.791.4200
DocuSign Envelope ID:606567A9-438E-4487-BA15-F58077AE1D34
Mr.Michael Barrett,NCG550642
March 4,2024 Page 3 of 4
5. Discharge outlet location. The permittee is required to conduct a visual review
of the outfall location at least twice each year (one at the time of sampling) to
ensure that no visible solids or other obvious evidence of system malfunctioning
is observed. Any visible signs of a malfunctioning system shall be documented,
and steps taken to correct the problem. The discharge pipe was visible and
accessible the day of the inspection. Please continue to ensure the outlet is
always visible/maintained and cleared of vegetation, soil, and leaves.
Part II Section B.14 of General Permit NCG550000 requires the permittee to "pay the annual
administering and compliance monitoring fee within thirty days after being billed by the
Division." Division records indicate the required annual fee ($60 per year) for the period ending
September 30, 2024, and due November 3, 2023, has been paid. There are no overdue fees for
the subject COC.
Please continue to periodically inspect the wastewater treatment system to ensure the treatment
components are always maintained and in good operating order. You are also reminded to
maintain all monitoring data and associated maintenance records onsite for a minimum of
three years and available for inspection.
Please submit a written response to this office by April 30, 2024 indicating the actions you will
take or have taken to comply with or resolve the issue noted in item 4 above.
If you have questions or comments about this inspection or the requirements to take corrective
action(if applicable), then please contact Donald Smith at 919-791-4234
Sincerely,
DocuSigned by:
Uiun t,SS f,
B2916E6AB32144F...
Vanessa E. Manuel, Assistant Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources,NCDEQ
Attachment(s): EPA Water Compliance Inspection Report
Cc: Laserfiche
D E Q�� North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive I Raleigh,North Carolina 27609
NORTH CAROUNA _
Depwbnwd„F r m- 919.791.4200
DocuSign Envelope ID:606567A9-438E-4487-BA15-F58077AE1D34
Mr. Michael Barrett,NCG550642
March 4, 2024 Page 4 of 4
<< M t
* Z
r
i 7` ,t•
i •
�.
'i ♦ f j•� r I r
•�,�'"fir:�' :.�..
Photo 1.Soil settlement at septic tank
D E Q�� North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive I Raleigh,North Carolina 27609
NORTH CAROUNA _
Depwbnmd„F r��,�wla�,\ /./ 919.791.4200
DocuSign Envelope ID:606567A9-438E-4487-BA15-F58077AE1D34
United States Environmental Protection Agency Form Approved.
EPA Washington,D.C.20460 OMB No.2040-0057
Water Compliance Inspection Report Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 2 u 3 I NCG550642 111 121 24/02/28 I17 18[C]I 19 I G I 20U
21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved-------------------
67 70 J 71 Ity 72 L-J 73 1 74 79 I I I I 80
Section B: Facility Data
Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date
POTW name and NPDES Dermit Number) 09:55AM 24/02/28 22/07/28
343 Carlton Drive
343 Carlton Dr Exit Time/Date Permit Expiration Date
Chapel Hill NC 27516 10:10AM 24/02/28 25/10/31
Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data
Name,Address of Responsible Official/Title/Phone and Fax Number
Contacted
Michael Barrett,343 Carlton Dr Chapel Hill NC 27516//336-340-6676/
Yes
Section C:Areas Evaluated During Inspection (Check only those areas evaluated)
Permit 0 Records/Reports 0 Facility Site Review 0 Effluent/Receiving Wate
Section D: Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Donald Smith Docusigned by: DWR/RRO WQ/919-791-4234/ 02/28/2024
E
ati.l�o� C
512ED5247FA847A...
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
DocuSigned by: 3/4/2024
ViUn t,SS -e. M.A,,,lkd
62916E6AB32144F_.
EPA Form 3560-3(Rev 9-94)Previous editions are obsolete.
Page#
DocuSign Envelope ID:606567A9-438E-4487-BA15-F58077AE1D34
NPDES yr/mo/day Inspection Type 1
31 NCG550642 I11 12I 24/02/28 11 7 18 i c i
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Permitee notified inspector of some soil settling around new septic tank installation perfromed by
previous owner. Septic tank pumping receipt- cleraning February 2, 2024. No effluent sampling
record received for sampling within last year.
Page# 2
DocuSign Envelope ID:606567A9-438E-4487-BA15-F58077AE1D34
Permit: NCG550642 Owner-Facility: 343 Carlton Drive
Inspection Date: 02/28/2024 Inspection Type: Compliance Evaluation
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑
application?
Is the facility as described in the permit? 0 ❑ ❑ ❑
#Are there any special conditions for the permit? ■ ❑ ❑ ❑
Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑
Is the inspector granted access to all areas for inspection? ❑ ❑ ❑
Comment:
Page# 3