HomeMy WebLinkAboutSW6230705_Design Calculations_20240304 (24) SERENTIY 3,4 & 5 SCM 14 Drawdown Time Temporary storage volume= 28,551 cf Orifice#ldiameter= 2.8 in # 1 Area of orifice= 0.0428 sf Orifice Coefficient(Cd) = 0.60 Orifice elevation= 303.00 ft Water elevation= 304.82 ft Driving head(H)= 0.61 ft Discharge(Q)= 0.160508 cfs Drawdown time= 177881 s 49.4 hr 2_1 days