Loading...
HomeMy WebLinkAboutNC0047279_Authorization to Construct_20001009A. State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director October 9, 2000 Mr. Charles Bradshaw C&J Bradshaw, LLC 6659 Private School Road Oxford, North Carolina 27565 4&10 IFA NCDENR Subject: Authorization to Construct NPDES Permit No. NCO047279 ATC No. 047279ACA Heritage Meadows WWTP Granville County Dear Mr. Bradshaw: The Division of Water Quality's NPDES Unit has reviewed your request for an Authorization to Construct permit for the Heritage Meadows WWTP. The Division finds the proposed improvements to be satisfactory and hereby grants authorization for the following: Installation of 1 module/2 lamp ultraviolet disinfection system, Retention of tablet chlorination as a means of back-up disinfection, and Any other piping, valves, control equipment, and appurtenances. This Authorization to Construct is issued in accordance with NPDES Permit No. NC0047279, issued January 31, 2000, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the terms and conditions of the permit. The Permittee shall notify the Water Quality staff of the Raleigh Regional Office, telephone number (919) 471-4700, at least forty-eight (48) hours prior to operation of the installed facilities, so that an in -place inspection can be made. Notification shall be made during the normal office hours of 8:00 a.m. until 5:00 p.m., Monday through Friday. Engineer's Certification Upon completion of construction and prior to operation of the modified facility, the Permittee shall provide the Division with a certification (copy enclosed) from a professional engineer registered in North Carolina certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct, and the approved plans and specifications. The Certification should be submitted to: NCDENR / DWQ, NPDES Unit, 1617 Mail Service Center, Raleigh, North Carolina 27699-1617. Requirements for Certified Operator Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified water pollution control treatment system operator to be in responsible charge (ORC) of the water pollution control treatment system. The operator must hold a certificate of the type and 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone (919) 733-5083 FAX (919) 733-0719 An Equal Opportunity Affirmative Action Employer Internet: http://h2o.enr.state.ne.ust Heritage Meadows WWTP NPDES Permit No. NCO047279 ATC No. 047279ACA Page 2 grade at least equivalent to or greater than the classification assigned to the water pollution control treatment system by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of Title 15A, Chapter 8G, .0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III, and IV facility at least daily, excluding weekends and holidays, and must properly manage and document daily operation and maintenance of the facility and must comply with all other conditions outlined in Title 15A, Chapter 8G, .0204. Once the facility is classified, the Permittee must submit a letter to the Certification Commission which designates the operator in responsible charge within: (A) Sixty calendar days prior to wastewater being introduced into a new system or (B) within 120 calendar days of the following, (i) after receiving notification of a change in the classification of the system requiring the designation of a new ORC and back-up ORC or (if) a vacancy in the position of ORC or back-up ORC. Additional Requirements The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and is a condition of this Permit. Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all sanctions provided by G. S. 143-215.6 for violation of or failure to act in accordance with the terms and conditions of this Permit. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division of Water Quality in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. The Permittee shall maintain a copy of the approved plans and specifications on file for the life of the facility. One (1) copy of the approved plans and specifications is enclosed for your records. If you have any questions about this Authorization to Construct permit, please contact Susan A. Wilson, at (919) 733-5083, extension 510. Sincerely, W err T. Stevens Enclosures: Project Plans and Specifications (approved) Engineers Certification Form cc: Raleigh Regional Office, Water Quality Technical Assistance and Certification Unit Central Files NPDES Unit Files Mr. James R. Butler, P.E. P.O. Box 627 Morehead City, NC 28557 NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Aia_ NCDENRDIVISION OF WATER QUALITY 63 �- JAMES B. HUNT JR.: GOVERNOR ^J October 27, 2000 BILL. HOLMAN CERTIFIED MAIL SECRETARY RETURN RECEIPT REQUESTED C&J Bradshaw, LLC Mr. Charles Bradshaw CRMANN suwns CHAIRMAN - 6659 Private School Road Oxford, North Carolina 27565 Subject: Classification of Water Pollution Control System Heritage Meadows WWTP Permit No. NCO047279 Granville County Dear Mr. Bradshaw: In accordance with North Carolina General Statute § 90A-37, the Water Pollution Control System Operators Certification Commission is required to classify all water pollution control systems. The classification of Biological Water Pollution Control Treatment Systems, found at 15A NCAC 8G .0302, was adopted by the Commission to classify water pollution control systems. The classification of a facility is determined by permitted flow and biological nutrient reduction limits. The Water Pollution Control System Operators Certification Commission has determined that the subject facility is classified as a Grade 2 Biological Water Pollution Control Treatment System. As required by 15A NCAC 8G .0202 and your permit, you must designate a Grade 2 or higher Operator in Responsible Charge (ORC) and a Back-up Operator with at least a Grade 1 certification of the appropriate type and grade for this system. Please complete and return the enclosed designation form, so we may update our database of any changes at your facility by November 27, 2000. It has been detemrined that the Authorization to Construct that you recently received requires no classification change at this facility. WATER POLLUTION CONTROL SYSTEM OPERATORS CERTIFICATION COMMISSION 1618 MAIL SERVICE CENTER, RALEIOH, NORTH CAROLINA 27699-1618 PHONE 919-733-0026 FAX 919-733-1335 AN EQUAL OPPORTUNITY / AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLED/10% POST -CONSUMER PAPER ,. To: STAFF REPORT AND RECOMMENDATIONS FOR AUTHORIZATION TO CONSTRUCT A UV DISINFECTION SYSTEM AT THE HERITAGE MEADOWS WWTP SOC PRIORITY PROJECT: Yes _ No X If Yes, SOC No.: NPDES Unit Attention: Susan Wilson County: Granville Permit No.: NCO047279 ATC Permit No.: 047279ACA Date: April 5, 2000 PART I -GENERAL INFORMATION 1. Facility Location: 2. 3. 4. 5. Q Mailing Address: Heritage Meadows WWTP 6659 Private School Road Oxford, NC 27565 same as above Report Prepared by: Timothy D. Baldwin p L P d a' r__ Ili APR 1 2 2C-J0 1 DENR - WATER OU.U_ITl' POINT SOURCE !?RANCH Date of most recent NPDES Staff Report (attach copy): August 6,1999 Changes since previous action on NPDES Permit: None (re -issued on 1/31/00) Discharge Point(s), list for all discharge points: Latitude: 36° 22' 57" Longitude: 78° 39' 33" Attach a USGS map extract and indicate treatment facility site and discharge point on map. U.S.G.S. Quad No.: B24NW U.S.G.S. Quad Name: Satterwhite Treatment plant classification (attach completed rating sheet): Grade II Biological WPCS Non -Discharge Staff Report Page 1 PROVIDE ADDITIONAL INFORMATION FOR PARTS I, II, AND III ONLY IF IT IS NOT PROVIDED IN ATTACHED STAFF REPORT 7. Date of Site Visit: 8. Persons Contacted and Telephone Number: 9. Directions to Site: 10. Site size and expansion area consistent with application? Yes: No: If No, explain: 11. Topography (relationship to flood plain included): 12. Location of nearest dwelling: 13. Receiving stream or affected surface waters: a. Classification: b. River Basin and Subbasin No.: C. Describe receiving stream features and pertinent downstream uses: PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of Wastewater to be permitted: b. What is the current permitted capacity of the Waste Water Treatment facility? C. Actual treatment capacity of the current facility (current design capacity)? d. Date(s) and construction activities allowed by previous Authorization to Construct issued in the previous two years: e. Please provide a description of existing or substantially constructed wastewater treatment facilities: f. Please provide a description of proposed wastewater treatment facilities: Replacement of the existing chlorine disinfection system with a UV disinfection unit. Non -Discharge Staff Report Page 2 g. Possible toxic impacts to surface waters: The UV system should remove the possible toxic impact of chlorine. h. Pretreatment Program (POTWs only): in development: approved: should be required: not needed: 2. Residuals handling and utilization/disposal scheme: a. If residuals are being land applied, please specify DWQ permit no.: Residual Contractor: Telephone No.: b. Residuals stabilization: PSRP: PFRP: Other: C. Landfill: d. Other disposal/utilization scheme (Specify): 3. SIC Code(s): 4. Wastewater Code(s) of actual wastewater, not particular facilities i.e.., non -contact cooling water discharge from a metal plating company would be 14, not 56. Include more than one code if applicable: 5. Main Treatment Unit Code: PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved (municipals only)? No 2. Special monitoring or limitations (including toxicity) requests: 3. Important SOC, JOC or Compliance Schedule dates: (Please indicate) Date Submission of Plans and Specifications Begin Construction Complete Construction Non -Discharge Staff Report Page 3 4. Alternative Analysis Evaluation: Has the facility evaluated all of the non -discharge options available? Please provide regional perspective for each option evaluated. Spray Irrigation: Connection to Regional Sewer System: Subsurface: Other disposal options: 5. Other Special Items: PART IV - EVALUATION AND RECOMMENDATIONS The Raleigh Regional Office has reviewed the current submittal package requesting Authorization to Construct (ATC) a UV disinfection system onto the Heritage Meadows WWTP facility. Our staff has reviewed our files of the above referenced site, as well as the plans and specifications submitted, in order to make the following comments and recommendations for the request. 1) The RRO recommends that consideration be given to maintaining a chlorine tablet disinfection system as a backup rather than require that a spare UV unit be kept on site. A spare UV unit can be easily damaged (exposure to elements, mishandling, etc.) during the several years that it may be stored on site as a backup, and therefore may not even be operational if needed. However, a tablet chlorinator backup is virtually damage -proof, and will operate properly whenever needed. 2) The plan sheet is very vague as to what exactly is being provided. The specifications state that the level will be controlled by an effluent weir, however, the plans only show a weir on the inlet end of the UV module channel. There is a box with a circle shown on the effluent end of the UV module channel. This box and circle are not described, and their function is unclear. In addition, there are two large "vaults?" that are provided on each end of the UV module. The function of these "vaults", as well as the angled line on the top of them (hinged opening lid?) is not clearly described. The engineer should be required to provide more accurate plans for review. Non -Discharge Staff Report Page 4 i1 With the above comments taken into consideration, the RRO recommends that the subject project be awarded an ATC as requested, pending NPDES Permitting Unit satisfaction of all requirements. Signature 2), -.4 preparer Water Quality Regional Supervisor Permit No. NC0047279 ATC No. 047279ACA File: h:latc-sr\ac47279a.sr Non -Discharge Staff Report Page 5 Y/'/-/o 0 16