Loading...
HomeMy WebLinkAboutSW6240107_O&M Agreement/Plan_20240205 Operation & Maintenance Agreement Project Name: Raeford South 115kV Build New Substation Project Location: 1600 Oakdale Gin Rd., Raeford, NC Cover Page Maintenance records shall be kept on the following SCM(s). This maintenance record shall be kept in a log in a known set location. Any deficient SCM elements noted in the inspection will be corrected, repaired, or replaced immediately. These deficiencies can affect the integrity of structures, safety of the public, and the pollutant removal efficiency of the SCM(s). The SCM(s)on this project include (check all that apply&corresponding O&M sheets will be added automatically): Infiltration Basin Quantity: 0 Location(s): Infiltration Trench Quantity: 0 Location(s): Bioretention Cell Quantity: 0 Location(s): Wet Pond Quantity: 0 Location(s): Stormwater Wetland Quantity: 0 Location(s): Permeable Pavement Quantity: 0 Location(s): Sand Filter Quantity: 0 Location(s): Rainwater Harvesting Quantity: 0 Location(s): Green Roof Quantity: 0 Location(s): Level Spreader- Filter Strip Quantity: 0 Location(s): Proprietary System Quantity: 0 Location(s): Treatment Swale Quantity: 0 Location(s): Dry Pond Quantity: 0 Location(s): Disconnected Impervious Surface Present: No Location(s): User Defined SCM Present: No Location(s): Low Density Present: Yes Type: Dispersed flow only CLICK TO UPDATE O&M MANUAL I acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed for each SCM above, and attached O&M tables. I agree to notify NCDEQ of any problems with the system or prior to any changes to the system or responsible party. Responsible Party: Alan Lewis Title &Organization: Manager, Transmission Engineering, Duke Energy Progress, LLC Street address: 410 South Wilmington Street City, state, zip: Raleigh, NC 27601 Phone number(s): (919) 546-7451 Email: alan.lewis@duke-energy.com Signature: Date: 0 I-o 3 —aaa I, 6 i n d� Car' otl n - 6;t c k e/S , a Notary Public for the State of �Cppt r t� (�2VLli<zee County of W a-��t✓ , do hereby certify that K l ee rt fie,W personally appeared before me this G J day of cz-v' a-w 1 9Q Z N and acknowledge the due execution of the Operations and Maintenance Agreement . Witness my hand and official seal, �i ��Gi- bD r- "C - k ; de-e Is CINDY CORDOVA-NICKELS /AIM NOTARY PUBLIC Fn�r / WAKE COUNTY NC My Commission Expires L.) Z� Seal My commission expires ) ) Z R 20 2-8/ STORM-EZ 12/19/2023 Version 1.5 O&M Agreement Page 1 of 1 Low Density Maintenance Requirements Important maintenance procedures: The drainage area to the vegetated conveyance or vegetated receiving area will be carefully managed to reduce the sediment load to the vegetated conveyance or After the initial fertilization to establish the grass in the vegetated conveyance or the vegetated receiving area, fertilizer will not be applied to the vegetated receiving The vegetated conveyance or vegetated receiving area will be inspected quarterly. Records of operation and maintenance will be kept in a known set location and will be available upon request. ection activities shall be performed as follows. Any problems that are found shall be repaired immedial SCM element: Potential problem: How to remediate the problem: Vegetation is too short Maintain gra-end vegetation such that the swale or Vegetation vegetated area does not erode during the peak flow or too long. from the 10-year storm I iaNvuCunsi' Remove the trash/debris. Vegetated receiving Areas of bare soil Regrade the soil if necessary to remove the gully, and areas and/or erosive gullies then re-sod (or plant with other appropriate species) formed. and water until established. Provide lime and a one- have time fertilizer application. Clogging has Clean out the outlet device. Dispose of the sediment occurred. off-site. The outlet device (if applicable) The outlet device is damaged Repair or replace the outlet device. Erosion or other signs Repair the damage and improve the flow dissipation of damage have occurred at the outlet. structure. The receiving water Discharges from the site are causing erosion or Contact the local NCDEQ Regional Office. sedimentation in the receiving water.